Time-efficient, high-resolution 3T whole-brain relaxometry using Cartesian 3D MR-STAT with CSF suppression
Authors:
Hongyan Liu,
Edwin Versteeg,
Miha Fuderer,
Oscar van der Heide,
Martin B. Schilder,
Cornelis A. T. van den Berg,
Alessandro Sbrizzi
Abstract:
Purpose: Current 3D Magnetic Resonance Spin TomogrAphy in Time-domain (MR-STAT) protocols use transient-state, gradient-spoiled gradient-echo sequences that are prone to cerebrospinal fluid (CSF) pulsation artifacts when applied to the brain. This study aims at develo** a 3D MR-STAT protocol for whole-brain relaxometry that overcomes the challenges posed by CSF-induced ghosting artifacts. Method…
▽ More
Purpose: Current 3D Magnetic Resonance Spin TomogrAphy in Time-domain (MR-STAT) protocols use transient-state, gradient-spoiled gradient-echo sequences that are prone to cerebrospinal fluid (CSF) pulsation artifacts when applied to the brain. This study aims at develo** a 3D MR-STAT protocol for whole-brain relaxometry that overcomes the challenges posed by CSF-induced ghosting artifacts. Method: We optimized the flip-angle train within the Cartesian 3D MR-STAT framework to achieve two objectives: (1) minimization of the noise level in the reconstructed quantitative maps, and (2) reduction of the CSF-to-white-matter signal ratio to suppress CSF signal and the associated pulsation artifacts. The optimized new sequence was tested on a gel/water-phantom to evaluate the accuracy of the quantitative maps, and on healthy volunteers to explore the effectiveness of the CSF artifact suppression and robustness of the new protocol. Results: A new optimized sequence with both high parameter encoding capability and low CSF intensity was proposed and initially validated in the gel/water-phantom experiment. From in-vivo experiments with five volunteers, the proposed CSF-suppressed sequence shows no CSF ghosting artifacts and overall greatly improved image quality for all quantitative maps compared to the baseline sequence. Statistical analysis indicated low inter-subject and inter-scan variability for quantitative parameters in gray matter and white matter (1.6%-2.4% for T1 and 2.0%-4.6% for T2), demonstrating the robustness of the new sequence. Conclusion: We presented a new 3D MR-STAT sequence with CSF suppression that effectively eliminates CSF pulsation artifacts. The new sequence ensures consistently high-quality, 1mm^3 whole-brain relaxometry within a rapid 5.5-minute scan time.
△ Less
Submitted 22 March, 2024;
originally announced March 2024.
-
Time-Resolved Reconstruction of Motion, Force, and Stiffness using Spectro-Dynamic MRI
Authors:
Max H. C. van Riel,
Tristan van Leeuwen,
Cornelis A. T. van den Berg,
Alessandro Sbrizzi
Abstract:
Measuring the dynamics and mechanical properties of muscles and joints is important to understand the (patho)physiology of muscles. However, acquiring dynamic time-resolved MRI data is challenging. We have previously developed Spectro-Dynamic MRI which allows the characterization of dynamical systems at a high spatial and temporal resolution directly from k-space data. This work presents an extend…
▽ More
Measuring the dynamics and mechanical properties of muscles and joints is important to understand the (patho)physiology of muscles. However, acquiring dynamic time-resolved MRI data is challenging. We have previously developed Spectro-Dynamic MRI which allows the characterization of dynamical systems at a high spatial and temporal resolution directly from k-space data. This work presents an extended Spectro-Dynamic MRI framework that reconstructs 1) time-resolved MR images, 2) time-resolved motion fields, 3) dynamical parameters, and 4) an activation force, at a temporal resolution of 11 ms. An iterative algorithm solves a minimization problem containing four terms: a motion model relating the motion to the fully-sampled k-space data, a dynamical model describing the expected type of dynamics, a data consistency term describing the undersampling pattern, and finally a regularization term for the activation force. We acquired MRI data using a dynamic motion phantom programmed to move like an actively driven linear elastic system, from which all dynamic variables could be accurately reconstructed, regardless of the sampling pattern. The proposed method performed better than a two-step approach, where time-resolved images were first reconstructed from the undersampled data without any information about the motion, followed by a motion estimation step.
△ Less
Submitted 11 October, 2023;
originally announced October 2023.
-
Real-time myocardial landmark tracking for MRI-guided cardiac radio-ablation using Gaussian Processes
Authors:
Niek R. F. Huttinga,
Osman Akdag,
Martin F. Fast,
Joost Verhoeff,
Firdaus A. A. Mohamed Hoesein,
Cornelis A. T. van den Berg,
Alessandro Sbrizzi,
Stefano Mandija
Abstract:
The high speed of cardiorespiratory motion introduces a unique challenge for cardiac stereotactic radio-ablation (STAR) treatments with the MR-linac. Such treatments require tracking myocardial landmarks with a maximum latency of 100 ms, which includes the acquisition of the required data. The aim of this study is to present a new method that allows to track myocardial landmarks from few readouts…
▽ More
The high speed of cardiorespiratory motion introduces a unique challenge for cardiac stereotactic radio-ablation (STAR) treatments with the MR-linac. Such treatments require tracking myocardial landmarks with a maximum latency of 100 ms, which includes the acquisition of the required data. The aim of this study is to present a new method that allows to track myocardial landmarks from few readouts of MRI data, thereby achieving a latency sufficient for STAR treatments. We present a tracking framework that requires only few readouts of k-space data as input, which can be acquired at least an order of magnitude faster than MR-images. Combined with the real-time tracking speed of a probabilistic machine learning framework called Gaussian Processes, this allows to track myocardial landmarks with a sufficiently low latency for cardiac STAR guidance, including both the acquisition of required data, and the tracking inference. The framework is demonstrated in 2D on a motion phantom, and in vivo on volunteers and a ventricular tachycardia (arrhythmia) patient. Moreover, the feasibility of an extension to 3D was demonstrated by in silico 3D experiments with a digital motion phantom. The framework was compared with template matching - a reference, image-based, method - and linear regression methods. Results indicate an order of magnitude lower total latency (<10 ms) for the proposed framework in comparison with alternative methods. The root-mean-square-distances and mean end-point-distance with the reference tracking method was less than 0.8 mm for all experiments, showing excellent (sub-voxel) agreement. The high accuracy in combination with a total latency of less than 10 ms - including data acquisition and processing - make the proposed method a suitable candidate for tracking during STAR treatments.
△ Less
Submitted 19 June, 2023;
originally announced June 2023.
-
Acceleration Strategies for MR-STAT: Achieving High-Resolution Reconstructions on a Desktop PC within 3 minutes
Authors:
Hongyan Liu,
Oscar van der Heide,
Stefano Mandija,
Cornelis A. T. van den Berg,
Alessandro Sbrizzi
Abstract:
MR-STAT is an emerging quantitative magnetic resonance imaging technique which aims at obtaining multi-parametric tissue parameter maps from single short scans. It describes the relationship between the spatial-domain tissue parameters and the time-domain measured signal by using a comprehensive, volumetric forward model. The MR-STAT reconstruction solves a large-scale nonlinear problem, thus is v…
▽ More
MR-STAT is an emerging quantitative magnetic resonance imaging technique which aims at obtaining multi-parametric tissue parameter maps from single short scans. It describes the relationship between the spatial-domain tissue parameters and the time-domain measured signal by using a comprehensive, volumetric forward model. The MR-STAT reconstruction solves a large-scale nonlinear problem, thus is very computationally challenging. In previous work, MR-STAT reconstruction using Cartesian readout data was accelerated by approximating the Hessian matrix with sparse, banded blocks, and can be done on high performance CPU clusters with tens of minutes. In the current work, we propose an accelerated Cartesian MR-STAT algorithm incorporating two different strategies: firstly, a neural network is trained as a fast surrogate to learn the magnetization signal not only in the full time-domain but also in the compressed lowrank domain; secondly, based on the surrogate model, the Cartesian MR-STAT problem is re-formulated and split into smaller sub-problems by the alternating direction method of multipliers. The proposed method substantially reduces the computational requirements for runtime and memory. Simulated and in-vivo balanced MR-STAT experiments show similar reconstruction results using the proposed algorithm compared to the previous sparse Hessian method, and the reconstruction times are at least 40 times shorter. Incorporating sensitivity encoding and regularization terms is straightforward, and allows for better image quality with a negligible increase in reconstruction time. The proposed algorithm could reconstruct both balanced and gradient-spoiled in-vivo data within 3 minutes on a desktop PC, and could thereby facilitate the translation of MR-STAT in clinical settings.
△ Less
Submitted 4 May, 2022;
originally announced May 2022.
-
Free-breathing motion compensated 4D (3D+respiration) T2-weighted turbo spin-echo MRI for body imaging
Authors:
T. Bruijnen,
T. Schake,
O. Akdag,
C. V. M. Bruel,
J. J. W. Lagendijk,
C. A. T. van den Berg,
R. H. N. Tijssen
Abstract:
Purpose: To develop and evaluate a free-breathing respiratory motion compensated 4D (3D+respiration) $T_2$-weighted turbo spin echo sequence with application to radiology and MR-guided radiotherapy.
Methods: k-space data are continuously acquired using a rewound Cartesian acquisition with spiral profile ordering (rCASPR) to provide matching contrast to the conventional linear phase encode orderi…
▽ More
Purpose: To develop and evaluate a free-breathing respiratory motion compensated 4D (3D+respiration) $T_2$-weighted turbo spin echo sequence with application to radiology and MR-guided radiotherapy.
Methods: k-space data are continuously acquired using a rewound Cartesian acquisition with spiral profile ordering (rCASPR) to provide matching contrast to the conventional linear phase encode ordering and to sort data into multiple respiratory phases. Low-resolution respiratory-correlated 4D images were reconstructed with compressed sensing and used to estimate non-rigid deformation vector fields, which were subsequently used for a motion compensated image reconstruction. rCASPR sampling was compared to linear and CASPR sampling in terms of point-spread-function (PSF) and image contrast with in silico, phantom and in vivo experiments. Reconstruction parameters for low-resolution 4D-MRI (spatial resolution and temporal regularization) were determined using a grid search. The proposed motion compensated rCASPR was evaluated in eight healthy volunteers and compared to free-breathing scans with linear sampling. Image quality was compared based on visual inspection and quantitatively by means of the gradient entropy.
Results: rCASPR provided a superior PSF (similar in ky and narrower in kz) and showed no considerable differences in images contrast compared to linear sampling. The optimal 4D-MRI reconstruction parameters were spatial resolution=$4.5 mm^3$ and $λ_t=10^{-4}$. The groupwise average gradient entropy was 22.31 for linear, 22.20 for rCASPR, 22.14 for soft-gated rCASPR and 22.02 for motion compensated rCASPR.
Conclusion: The proposed motion compensated rCASPR enables high quality free-breathing T2-TSE with minimal changes in image contrast and scan time. The proposed method therefore enables direct transfer of clinically used 3D TSE sequences to free-breathing.
△ Less
Submitted 7 February, 2022;
originally announced February 2022.
-
Real-time non-rigid 3D respiratory motion estimation for MR-guided radiotherapy using MR-MOTUS
Authors:
Niek R. F. Huttinga,
Tom Bruijnen,
Cornelis A. T. van den Berg,
Alessandro Sbrizzi
Abstract:
The MR-Linac is a combination of an MR-scanner and radiotherapy linear accelerator (Linac) which holds the promise to increase the precision of radiotherapy treatments with MR-guided radiotherapy by monitoring motion during radiotherapy with MRI, and adjusting the radiotherapy plan accordingly. Optimal MR-guidance for respiratory motion during radiotherapy requires MR-based 3D motion estimation wi…
▽ More
The MR-Linac is a combination of an MR-scanner and radiotherapy linear accelerator (Linac) which holds the promise to increase the precision of radiotherapy treatments with MR-guided radiotherapy by monitoring motion during radiotherapy with MRI, and adjusting the radiotherapy plan accordingly. Optimal MR-guidance for respiratory motion during radiotherapy requires MR-based 3D motion estimation with a latency of 200-500 ms. Currently this is still challenging since typical methods rely on MR-images, and are therefore limited by the 3D MR-imaging latency. In this work, we present a method to perform non-rigid 3D respiratory motion estimation with 170 ms latency, including both acquisition and reconstruction. The proposed method called real-time low-rank MR-MOTUS reconstructs motion-fields directly from k-space data, and leverages an explicit low-rank decomposition of motion-fields to split the large scale 3D+t motion-field reconstruction problem posed in our previous work into two parts: (I) a medium-scale offline preparation phase and (II) a small-scale online inference phase which exploits the results of the offline phase for real-time computations. The method was validated on free-breathing data of five volunteers, acquired with a 1.5T Elekta Unity MR-Linac. Results show that the reconstructed 3D motion-field are anatomically plausible, highly correlated with a self-navigation motion surrogate (R = 0.975 +/- 0.0110), and can be reconstructed with a total latency of 170 ms that is sufficient for real-time MR-guided abdominal radiotherapy.
△ Less
Submitted 14 September, 2021; v1 submitted 16 April, 2021;
originally announced April 2021.
-
Fast and Accurate Modeling of Transient-State Gradient-Spoiled Sequences by Recurrent Neural Networks
Authors:
Hongyan Liu,
Oscar van der Heide,
Cornelis A. T. van den Berg,
Alessandro Sbrizzi
Abstract:
Fast and accurate modeling of MR signal responses are typically required for various quantitative MRI applications, such as MR Fingerprinting and MR-STAT. This work uses a new EPG-Bloch model for accurate simulation of transient-state gradient-spoiled MR sequences, and proposes a Recurrent Neural Network (RNN) as a fast surrogate of the EPG-Bloch model for computing large-scale MR signals and deri…
▽ More
Fast and accurate modeling of MR signal responses are typically required for various quantitative MRI applications, such as MR Fingerprinting and MR-STAT. This work uses a new EPG-Bloch model for accurate simulation of transient-state gradient-spoiled MR sequences, and proposes a Recurrent Neural Network (RNN) as a fast surrogate of the EPG-Bloch model for computing large-scale MR signals and derivatives. The computational efficiency of the RNN model is demonstrated by comparing with other existing models, showing one to three orders of acceleration comparing to the latest GPU-accelerated open-source EPG package. By using numerical and in-vivo brain data, two use cases, namely MRF dictionary generation and optimal experimental design, are also provided. Results show that the RNN surrogate model can be efficiently used for computing large-scale dictionaries of transient-states signals and derivatives within tens of seconds, resulting in several orders of magnitude acceleration with respect to state-of-the-art implementations. The practical application of transient-states quantitative techniques can therefore be substantially facilitated.
△ Less
Submitted 21 August, 2020; v1 submitted 17 August, 2020;
originally announced August 2020.
-
Non-rigid 3D motion estimation at high temporal resolution from prospectively undersampled k-space data using low-rank MR-MOTUS
Authors:
Niek R. F. Huttinga,
Tom Bruijnen,
Cornelis A. T. van den Berg,
Alessandro Sbrizzi
Abstract:
With the recent introduction of the MR-LINAC, an MR-scanner combined with a radiotherapy LINAC, MR-based motion estimation has become of increasing interest to (retrospectively) characterize tumor and organs-at-risk motion during radiotherapy. To this extent, we introduce low-rank MR-MOTUS, a framework to retrospectively reconstruct time-resolved non-rigid 3D+t motion-fields from a single low-reso…
▽ More
With the recent introduction of the MR-LINAC, an MR-scanner combined with a radiotherapy LINAC, MR-based motion estimation has become of increasing interest to (retrospectively) characterize tumor and organs-at-risk motion during radiotherapy. To this extent, we introduce low-rank MR-MOTUS, a framework to retrospectively reconstruct time-resolved non-rigid 3D+t motion-fields from a single low-resolution reference image and prospectively undersampled k-space data acquired during motion. Low-rank MR-MOTUS exploits spatio-temporal correlations in internal body motion with a low-rank motion model, and inverts a signal model that relates motion-fields directly to a reference image and k-space data. The low-rank model reduces the degrees-of-freedom, memory consumption and reconstruction times by assuming a factorization of space-time motion-fields in spatial and temporal components. Low-rank MR-MOTUS was employed to estimate motion in 2D/3D abdominothoracic scans and 3D head scans. Data were acquired using golden-ratio radial readouts. Reconstructed 2D and 3D respiratory motion-fields were respectively validated against time-resolved and respiratory-resolved image reconstructions, and the head motion against static image reconstructions from fully-sampled data acquired right before and right after the motion. Results show that 2D+t respiratory motion can be estimated retrospectively at 40.8 motion-fields-per-second, 3D+t respiratory motion at 7.6 motion-fields-per-second and 3D+t head-neck motion at 9.3 motion-fields-per-second. The validations show good consistency with image reconstructions. The proposed framework can estimate time-resolved non-rigid 3D motion-fields, which allows to characterize drifts and intra and inter-cycle patterns in breathing motion during radiotherapy, and could form the basis for real-time MR-guided radiotherapy.
△ Less
Submitted 1 July, 2020;
originally announced July 2020.
-
Combining Deep Learning and 3D Contrast Source Inversion in MR-based Electrical Properties Tomography
Authors:
Reijer L. Leijsen,
Cornelis A. T. van den Berg,
Andrew G. Webb,
Rob F. Remis,
Stefano Mandija
Abstract:
Magnetic resonance-electrical properties tomography (MR-EPT) is a technique used to estimate the conductivity and permittivity of tissues from MR measurements of the transmit magnetic field. Different reconstruction methods are available, however all these methods present several limitations which hamper the clinical applicability. Standard Helmholtz based MR-EPT methods are severely affected by n…
▽ More
Magnetic resonance-electrical properties tomography (MR-EPT) is a technique used to estimate the conductivity and permittivity of tissues from MR measurements of the transmit magnetic field. Different reconstruction methods are available, however all these methods present several limitations which hamper the clinical applicability. Standard Helmholtz based MR-EPT methods are severely affected by noise. Iterative reconstruction methods such as contrast source inversion-EPT (CSI-EPT) are typically time consuming and are dependent on their initialization. Deep learning (DL) based methods require a large amount of training data before sufficient generalization can be achieved. Here, we investigate the benefits achievable using a hybrid approach, i.e. using MR-EPT or DL-EPT as initialization guesses for standard 3D CSI-EPT. Using realistic electromagnetic simulations at 3 T and 7 T, the accuracy and precision of hybrid CSI reconstructions are compared to standard 3D CSI-EPT reconstructions. Our results indicate that a hybrid method consisting of an initial DL-EPT reconstruction followed by a 3D CSI-EPT reconstruction would be beneficial. DL-EPT combined with standard 3D CSI-EPT exploits the power of data driven DL-based EPT reconstructions while the subsequent CSI-EPT facilitates a better generalization by providing data consistency.
△ Less
Submitted 13 August, 2019;
originally announced August 2019.
-
Deep learning brain conductivity map** using a patch-based 3D U-net
Authors:
Nils Hampe,
Ulrich Katscher,
Cornelis A. T. van den Berg,
Khin Khin Tha,
Stefano Mandija
Abstract:
Purpose: To investigate deep learning electrical properties tomography (EPT) for application on different simulated and in-vivo datasets including pathologies for obtaining quantitative brain conductivity maps. Methods: 3D patch-based convolutional neural networks were trained to predict conductivity maps from B1 transceive phase data. To compare the performance of DLEPT networks on different data…
▽ More
Purpose: To investigate deep learning electrical properties tomography (EPT) for application on different simulated and in-vivo datasets including pathologies for obtaining quantitative brain conductivity maps. Methods: 3D patch-based convolutional neural networks were trained to predict conductivity maps from B1 transceive phase data. To compare the performance of DLEPT networks on different datasets, three datasets were used throughout this work, one from simulations and two from in-vivo measurements from healthy volunteers and cancer patients, respectively. At first, networks trained on simulations are tested on all datasets with different levels of homogeneous Gaussian noise introduced in training and testing. Secondly, to investigate potential robustness towards systematical differences between simulated and measured phase maps, in-vivo data with conductivity labels from conventional EPT is used for training. Results: High quality of reconstructions from networks trained on simulations with and without noise confirms the potential of deep learning for EPT. However, artifact encumbered results in this work uncover challenges in application of DLEPT to in-vivo data. Training DLEPT networks on conductivity labels from conventional EPT improves quality of results. This is argued to be caused by robustness to artifacts from image acquisition. Conclusions: Networks trained on simulations with added homogeneous Gaussian noise yield reconstruction artifacts when applied to in-vivo data. Training with realistic phase data and conductivity labels from conventional EPT allows for severely reducing these artifacts.
△ Less
Submitted 12 August, 2019;
originally announced August 2019.
-
Opening a new window on MR-based Electrical Properties Tomography with deep learning
Authors:
Stefano Mandija,
Ettore F. Meliadò,
Niek R. F. Huttinga,
Peter R. Luijten,
Cornelis A. T. van den Berg
Abstract:
Electrical properties (EPs) of tissues, conductivity and permittivity, are modulated by the ionic and water content, which change in presence of pathologies. Information on tissues EPs can be used e.g. as an endogenous biomarker in oncology. MR-Electrical Properties Tomography (MR-EPT) aims to reconstruct tissue EPs by solving an electromagnetic inverse problem relating MR measurements of the tran…
▽ More
Electrical properties (EPs) of tissues, conductivity and permittivity, are modulated by the ionic and water content, which change in presence of pathologies. Information on tissues EPs can be used e.g. as an endogenous biomarker in oncology. MR-Electrical Properties Tomography (MR-EPT) aims to reconstruct tissue EPs by solving an electromagnetic inverse problem relating MR measurements of the transmit radiofrequency RF field to the EPs. However, MR-EPT reconstructions highly suffer from noise in the RF field maps, which limits the clinical applicability. Instead of employing electromagnetic models posing strict requirements on the measured quantities, we propose a data driven approach where the inverse transformation is learned by means of a neural network. Supervised training of a conditional generative adversarial neural network was performed using simulated realistic RF field maps and realistic human head dielectric models. Deep learning EPT (DL-EPT) reconstructions are presented for in-silica MR data and MR measurements at 3 Tesla on phantoms and human brains. DL-EPT shows high quality EP maps, demonstrating good accuracy and greatly improved precision compared to conventional MR-EPT. Moreover, DL-EPT allows permittivity reconstructions at 3 Tesla, which is not possible with state-of-art MR-EPT techniques. The supervised learning-based approach leverages the strength of tailored electromagnetic simulations, allowing inclusion of a priori information (e.g. coil setup) and circumvention of inaccessible MR electromagnetic quantities. Since DL-EPT is highly noise-robust, the requirements for MRI data acquisitions can be relaxed, allowing faster acquisitions and higher resolutions. We believe that DL-EPT greatly improves the quality and applicability of EPT opening a new window for an endogenous biomarker in MRI diagnostics that reflects differences in ionic tissue content.
△ Less
Submitted 19 August, 2019; v1 submitted 30 March, 2018;
originally announced April 2018.