-
The CIPM list "Recommended values of standard frequencies": 2021 update
Authors:
H S Margolis,
G Panfilo,
G Petit,
C Oates,
T Ido,
S Bize
Abstract:
This paper gives a detailed account of the analysis underpinning the 2021 update to the list of standard reference frequency values recommended by the International Committee for Weights and Measures (CIPM). This update focused on a subset of atomic transitions that are secondary representations of the second (SRS) or considered as potential SRS. As in previous updates in 2015 and 2017, methods fo…
▽ More
This paper gives a detailed account of the analysis underpinning the 2021 update to the list of standard reference frequency values recommended by the International Committee for Weights and Measures (CIPM). This update focused on a subset of atomic transitions that are secondary representations of the second (SRS) or considered as potential SRS. As in previous updates in 2015 and 2017, methods for analysing over-determined data sets were applied to make optimum use of the worldwide body of published clock comparison data. To ensure that these methods were robust, three independent calculations were performed using two different algorithms. The 2021 update differed from previous updates in taking detailed account of correlations among the input data, a step shown to be important in deriving unbiased frequency values and avoiding underestimation of their uncertainties. It also differed in the procedures used to assess input data and to assign uncertainties to the recommended frequency values, with previous practice being adapted to produce a fully consistent output data set consisting of frequency ratio values as well as absolute frequencies. These changes are significant in the context of an anticipated redefinition of the second in terms of an optical transition or transitions, since optical frequency ratio measurements will be critical for verifying the international consistency of optical clocks prior to the redefinition. In the meantime, the reduced uncertainties for optical SRS resulting from this analysis significantly increases the weight that secondary frequency standards based on these transitions can have in the steering of International Atomic Time (TAI).
△ Less
Submitted 25 January, 2024;
originally announced January 2024.
-
Roadmap towards the redefinition of the second
Authors:
N. Dimarcq,
M. Gertsvolf,
G. Mileti,
S. Bize,
C. W. Oates,
E. Peik,
D. Calonico,
T. Ido,
P. Tavella,
F. Meynadier,
G. Petit,
G. Panfilo,
J. Bartholomew,
P. Defraigne,
E. A. Donley,
P. O. Hedekvist,
I. Sesia,
M. Wouters,
P. Dube,
F. Fang,
F. Levi,
J. Lodewyck,
H. S. Margolis,
D. Newell,
S. Slyusarev
, et al. (12 additional authors not shown)
Abstract:
This paper outlines the roadmap towards the redefinition of the second, which was recently updated by the CCTF Task Force created by the CCTF in 2020. The main achievements and the open challenges related to the status of the optical frequency standards, their contribution to time scales and UTC, the possibility of their comparison and the knowledge of the Earth's gravitational potential at the ne…
▽ More
This paper outlines the roadmap towards the redefinition of the second, which was recently updated by the CCTF Task Force created by the CCTF in 2020. The main achievements and the open challenges related to the status of the optical frequency standards, their contribution to time scales and UTC, the possibility of their comparison and the knowledge of the Earth's gravitational potential at the necessary level of uncertainty are discussed. In addition, the mandatory criteria to be achieved before redefinition and their current fulfilment level, together with the redefinition options based on a single or on a set of transitions are described.
△ Less
Submitted 26 July, 2023;
originally announced July 2023.
-
Frequency ratio of an $^{115}$In$^+$ ion clock and a $^{87}$Sr optical lattice clock
Authors:
Nozomi Ohtsubo,
Ying Li,
Nils Nemitz,
Hidekazu Hachisu,
Kensuke Matsubara,
Tetsuya Ido,
Kazuhiro Hayasaka
Abstract:
We report on the first frequency ratio measurement of an $^{115}$In+ single ion clock and a $^{87}$Sr optical lattice clock. A hydrogen maser serves as a reference oscillator to measure the ratio by independent optical combs. Over more than 90 000 seconds of measurement time, the frequency ratio $f_{\rm{In^+}}/f_{\rm{Sr}}$ is determined to be 2.952 748 749 874 863 4(21) with relative uncertainty o…
▽ More
We report on the first frequency ratio measurement of an $^{115}$In+ single ion clock and a $^{87}$Sr optical lattice clock. A hydrogen maser serves as a reference oscillator to measure the ratio by independent optical combs. Over more than 90 000 seconds of measurement time, the frequency ratio $f_{\rm{In^+}}/f_{\rm{Sr}}$ is determined to be 2.952 748 749 874 863 4(21) with relative uncertainty of $7.0 \times 10^{-16}$. The measurement creates a new connection in the network of frequency ratios of optical clocks.
△ Less
Submitted 30 October, 2020; v1 submitted 14 August, 2020;
originally announced August 2020.
-
Absolute frequency of $^{87}\mathrm{Sr}$ at $1.8 \times 10^{-16}$ uncertainty by reference to remote Primary Frequency Standards
Authors:
Nils Nemitz,
Tadahiro Gotoh,
Fumimaru Nakagawa,
Hiroyuki Ito,
Yuko Hanado,
Tetsuya Ido,
Hidekazu Hachisu
Abstract:
The optical lattice clock NICT-Sr1 regularly reports calibration measurements of the international timescale TAI. By comparing measurement results to the reports of eight Primary Frequency Standards, we find the absolute frequency of the $^{87}\mathrm{Sr}$ clock transition to be f(Sr)=$429\,228\,004\,229\,873.082(76)$, with a fractional uncertainty of less than 1.8x10$^{-16}$ approaching the syste…
▽ More
The optical lattice clock NICT-Sr1 regularly reports calibration measurements of the international timescale TAI. By comparing measurement results to the reports of eight Primary Frequency Standards, we find the absolute frequency of the $^{87}\mathrm{Sr}$ clock transition to be f(Sr)=$429\,228\,004\,229\,873.082(76)$, with a fractional uncertainty of less than 1.8x10$^{-16}$ approaching the systematic limits of the best realization of SI second. Our result is consistent with other recent measurements and further supported by the loop closure over the absolute frequencies of $^{87}\mathrm{Sr}$, $^{171}\mathrm{Yb}$ and direct optical measurements of their ratio.
△ Less
Submitted 3 August, 2020;
originally announced August 2020.
-
First observation with global network of optical atomic clocks aimed for a dark matter detection
Authors:
P. Wcisło,
P. Ablewski,
K. Beloy,
S. Bilicki,
M. Bober,
R. Brown,
R. Fasano,
R. Ciuryło,
H. Hachisu,
T. Ido,
J. Lodewyck,
A. Ludlow,
W. McGrew,
P. Morzyński,
D. Nicolodi,
M. Schioppo,
M. Sekido,
R. Le Targat,
P. Wolf,
X. Zhang,
B. Zjawin,
M. Zawada
Abstract:
We report on the first earth-scale quantum sensor network based on optical atomic clocks aimed at dark matter (DM) detection. Exploiting differences in the susceptibilities to the fine-structure constant of essential parts of an optical atomic clock, i.e. the cold atoms and the optical reference cavity, we can perform sensitive searches for dark matter signatures without the need of real-time comp…
▽ More
We report on the first earth-scale quantum sensor network based on optical atomic clocks aimed at dark matter (DM) detection. Exploiting differences in the susceptibilities to the fine-structure constant of essential parts of an optical atomic clock, i.e. the cold atoms and the optical reference cavity, we can perform sensitive searches for dark matter signatures without the need of real-time comparisons of the clocks. We report a two orders of magnitude improvement in constraints on transient variations of the fine-structure constant, which considerably improves the detection limit for the standard model (SM) - DM coupling. We use Yb and Sr optical atomic clocks at four laboratories on three continents to search for both topological defect (TD) and massive scalar field candidates. No signal consistent with a dark-matter coupling is identified, leading to significantly improved constraints on the DM-SM couplings.
△ Less
Submitted 12 June, 2018;
originally announced June 2018.
-
Months-long real-time generation of a time scale based on an optical clock
Authors:
Hidekazu Hachisu,
Fumimaru Nakagawa,
Yuko Hanado,
Tetsuya Ido
Abstract:
Time scales consistently provide precise time stamps and time intervals by combining atomic frequency standards with a reliable local oscillator. Optical frequency standards, however, have not been applied to the generation of time scales, although they provide superb accuracy and stability these days. Here, by steering an oscillator frequency based on the intermittent operation of a $^{87}$Sr opt…
▽ More
Time scales consistently provide precise time stamps and time intervals by combining atomic frequency standards with a reliable local oscillator. Optical frequency standards, however, have not been applied to the generation of time scales, although they provide superb accuracy and stability these days. Here, by steering an oscillator frequency based on the intermittent operation of a $^{87}$Sr optical lattice clock, we realized an "optically steered" time scale TA(Sr) that was continuously generated for half a year. The resultant time scale was as stable as International Atomic Time (TAI) with its accuracy at the $10^{-16}$ level. We also compared the time scale with TT(BIPM16). TT(BIPM) is computed in deferred time each January based on a weighted average of the evaluations of the frequency of TAI using primary and secondary frequency standards. The variation of the time difference TA(Sr) $-$ TT(BIPM16) was 0.79 ns after 5 months, suggesting the compatibility of using optical clocks for time scale generation. The steady signal also demonstrated the capability to evaluate one-month mean scale intervals of TAI over all six months with comparable uncertainties to those of primary frequency standards (PFSs).
△ Less
Submitted 9 March, 2018;
originally announced March 2018.
-
Advanced Satellite-based Frequency Transfer at the 10^{-16} Level
Authors:
M. Fujieda,
S-H. Yang,
T. Gotoh,
S-W. Hwang,
H. Hachisu,
H. Kim,
Y. K. Lee,
R. Tabuchi,
T. Ido,
W-K. Lee,
M-S. Heo,
C. Y. Park,
D-H. Yu,
G. Petit
Abstract:
Advanced satellite-based frequency transfers by TWCP and IPPP have been performed between NICT and KRISS. We confirm that the disagreement between them is less than 1x10^{-16} at an averaging time of several days. Additionally, an intercontinental frequency ratio measurement of Sr and Yb optical lattice clocks was directly performed by TWCP. We achieved an uncertainty at the mid-10^{-16} level aft…
▽ More
Advanced satellite-based frequency transfers by TWCP and IPPP have been performed between NICT and KRISS. We confirm that the disagreement between them is less than 1x10^{-16} at an averaging time of several days. Additionally, an intercontinental frequency ratio measurement of Sr and Yb optical lattice clocks was directly performed by TWCP. We achieved an uncertainty at the mid-10^{-16} level after a total measurement time of 12 hours. The frequency ratio was consistent with the recently reported values within the uncertainty.
△ Less
Submitted 6 October, 2017;
originally announced October 2017.
-
SI-traceable measurement of an optical frequency at low $10^{-16}$ level without a local primary standard
Authors:
Hidekazu Hachisu,
Gérard Petit,
Fumimaru Nakagawa,
Yuko Hanado,
Tetsuya Ido
Abstract:
SI-traceable measurements of optical frequencies using International Atomic Time (TAI) do not require a local primary frequency reference, but suffer from an uncertainty in tracing to the SI second. For the measurement of the $^{87}$Sr lattice clock transition, we have reduced this uncertainty to low $10^{-16}$ level by averaging three sets of ten-day intermittent measurements, in which we operate…
▽ More
SI-traceable measurements of optical frequencies using International Atomic Time (TAI) do not require a local primary frequency reference, but suffer from an uncertainty in tracing to the SI second. For the measurement of the $^{87}$Sr lattice clock transition, we have reduced this uncertainty to low $10^{-16}$ level by averaging three sets of ten-day intermittent measurements, in which we operated the lattice clock for $10^4$ s on each day. Moreover, a combined oscillator of two hydrogen masers was employed as a local flywheel oscillator (LFO) in order to mitigate the impact of sporadic excursion of LFO frequency. The resultant absolute frequency with fractional uncertainty of $4.3\times10^{-16}$ agrees with other measurements based on local state-of-the-art cesium fountains.
△ Less
Submitted 4 April, 2017;
originally announced April 2017.
-
Frequency measurement of the clock transition of an indium ion sympathetically-cooled in a linear trap
Authors:
Nozomi Ohtsubo,
Ying Li,
Kensuke Matsubara,
Tetsuya Ido,
Kazuhiro Hayasaka
Abstract:
We report frequency measurement of the clock transition in an 115In+ ion sympathetically-cooled with Ca+ ions in a linear rf trap. The Ca+ ions are used as a probe of the external electromagnetic field and as the coolant for preparing the cold In+. The frequency is determined to be 1 267 402 452 901 049.9 (6.9) Hz by averaging 36 measurements using an optical frequency comb referenced to the frequ…
▽ More
We report frequency measurement of the clock transition in an 115In+ ion sympathetically-cooled with Ca+ ions in a linear rf trap. The Ca+ ions are used as a probe of the external electromagnetic field and as the coolant for preparing the cold In+. The frequency is determined to be 1 267 402 452 901 049.9 (6.9) Hz by averaging 36 measurements using an optical frequency comb referenced to the frequency standards located in the same site.
△ Less
Submitted 2 May, 2017; v1 submitted 8 March, 2017;
originally announced March 2017.
-
Absolute frequency measurement with uncertainty below $1\times 10^{-15}$ using International Atomic Time
Authors:
Hidekazu Hachisu,
Gérard Petit,
Tetsuya Ido
Abstract:
The absolute frequency of the $^{87}{\rm Sr}$ clock transition measured in 2015 was reevaluated using an improved frequency link to the SI second. The scale interval of International Atomic Time (TAI) that we used as the reference was calibrated for an evaluation interval of five days instead of the conventional interval of one month which is regularly employed in Circular T. The calibration on a…
▽ More
The absolute frequency of the $^{87}{\rm Sr}$ clock transition measured in 2015 was reevaluated using an improved frequency link to the SI second. The scale interval of International Atomic Time (TAI) that we used as the reference was calibrated for an evaluation interval of five days instead of the conventional interval of one month which is regularly employed in Circular T. The calibration on a five-day basis removed the uncertainty in assimilating the TAI scale of the five-day mean to that of the one-month mean. The reevaluation resulted in the total uncertainty of $10^{-16}$ level for the first time without local cesium fountains. Since there are presumably no correlations among systematic shifts of cesium fountains worldwide, the measurement is not limited by the systematic uncertainty of a specific primary frequency standard.
△ Less
Submitted 26 November, 2016;
originally announced November 2016.
-
Intermittent optical frequency measurements to reduce the dead time uncertainty of frequency link
Authors:
Hidekazu Hachisu,
Tetsuya Ido
Abstract:
The absolute frequency of the $^{87}{\rm Sr}$ lattice clock transition was evaluated with an uncertainty of $1.1\times 10^{-15}$ using a frequency link to the international atomic time (TAI). The frequency uncertainty of a hydrogen maser used as a transfer oscillator was reduced by homogeneously distributed intermittent measurement over a five-day grid of TAI. Three sets of four or five days measu…
▽ More
The absolute frequency of the $^{87}{\rm Sr}$ lattice clock transition was evaluated with an uncertainty of $1.1\times 10^{-15}$ using a frequency link to the international atomic time (TAI). The frequency uncertainty of a hydrogen maser used as a transfer oscillator was reduced by homogeneously distributed intermittent measurement over a five-day grid of TAI. Three sets of four or five days measurements as well as systematic uncertainty of the clock at $8.6\times 10^{-17}$ have resulted in an absolute frequency of $^{87}{\rm Sr}\ {}^1S_0 - {}^3P_0$ clock transition to be 429 228 004 229 872.85 (47) Hz.
△ Less
Submitted 24 August, 2015;
originally announced August 2015.
-
Generation of vacuum ultraviolet radiation by intracavity high-harmonic generation toward state detection of single trapped ions
Authors:
Kentaro Wakui,
Kazuhiro Hayasaka,
Tetsuya Ido
Abstract:
VUV radiation around 159 nm is obtained toward direct excitation of a single trapped $^{115}$In$^{+}$ ion. An efficient fluoride-based VUV output-coupler is employed for intracavity high-harmonic generation of a Ti:S oscillator. Using this coupler, where we measured its reflectance to be about 90%, an average power reaching $6.4\,μ$W is coupled out from a modest fundamental power of 650 mW. When a…
▽ More
VUV radiation around 159 nm is obtained toward direct excitation of a single trapped $^{115}$In$^{+}$ ion. An efficient fluoride-based VUV output-coupler is employed for intracavity high-harmonic generation of a Ti:S oscillator. Using this coupler, where we measured its reflectance to be about 90%, an average power reaching $6.4\,μ$W is coupled out from a modest fundamental power of 650 mW. When a single comb component out of $1.9\times10^{5}$ teeth is resonant to the atomic transition, hundreds of fluorescence photons per second will be detectable under a realistic condition.
△ Less
Submitted 22 August, 2014; v1 submitted 21 June, 2014;
originally announced June 2014.
-
Direct comparison of optical lattice clocks with an intercontinental baseline of 9 000 km
Authors:
H. Hachisu,
M. Fujieda,
S. Nagano,
T. Gotoh,
A. Nogami,
T. Ido,
St. Falke,
N. Huntemann,
C. Grebing,
B. Lipphardt,
Ch. Lisdat,
D. Piester
Abstract:
We have demonstrated a direct frequency comparison between two $^{87}{\rm Sr}$ lattice clocks operated in intercontinentally separated laboratories in real time. Two-way satellite time and frequency transfer technique based on the carrier phase was employed for a direct comparison with a baseline of 9 000 km between Japan and Germany. A clock comparison was achieved for 83 640 s resulting in a fra…
▽ More
We have demonstrated a direct frequency comparison between two $^{87}{\rm Sr}$ lattice clocks operated in intercontinentally separated laboratories in real time. Two-way satellite time and frequency transfer technique based on the carrier phase was employed for a direct comparison with a baseline of 9 000 km between Japan and Germany. A clock comparison was achieved for 83 640 s resulting in a fractional difference of $(1.1\pm1.6) \times 10^{-15}$, where the statistical part is the biggest contribution to the uncertainty. This measurement directly confirms the agreement of the two optical clocks on an intercontinental scale.
△ Less
Submitted 12 July, 2014; v1 submitted 25 March, 2014;
originally announced March 2014.
-
Direct comparison of a Ca+ single ion clock against a Sr optical lattice clock
Authors:
Kensuke Matsubara,
Hidekazu Hachisu,
Ying Li,
Shigeo Nagano,
Clayton Locke,
Asahiko Nogami,
Masatoshi Kajita,
Kazuhiro Hayasaka,
Tetsuya Ido,
Mizuhiko Hosokawa
Abstract:
Optical frequency comparison of the 40Ca+ clock transition ν_{Ca} (2S1/2-2D5/2, 729nm) against the 87Sr optical lattice clock transition ν_{Sr}(1S0-3P0, 698nm) has resulted in a frequency ratio ν_{Ca} / ν_{Sr} = 0.957 631 202 358 049 9(2 3). The rapid nature of optical comparison allowed the statistical uncertainty of frequency ratio ν_{Ca} / ν_{Sr} to reach 1x10-15 in only 1000s and yielded a val…
▽ More
Optical frequency comparison of the 40Ca+ clock transition ν_{Ca} (2S1/2-2D5/2, 729nm) against the 87Sr optical lattice clock transition ν_{Sr}(1S0-3P0, 698nm) has resulted in a frequency ratio ν_{Ca} / ν_{Sr} = 0.957 631 202 358 049 9(2 3). The rapid nature of optical comparison allowed the statistical uncertainty of frequency ratio ν_{Ca} / ν_{Sr} to reach 1x10-15 in only 1000s and yielded a value consistent with that calculated from separate absolute frequency measurements of ν_{Ca} using the International Atomic Time (TAI) link. The total uncertainty of the frequency ratio using optical comparison (free from microwave link uncertainties) is smaller than that obtained using absolute frequency measurement, demonstrating the advantage of optical frequency evaluation. We report the absolute frequency of ^{40}Ca+ with a systematic uncertainty 14 times smaller than our previous measurement [1].
△ Less
Submitted 22 August, 2012;
originally announced August 2012.
-
Stability Transfer between Two Clock Lasers Operating at Different Wavelengths for Absolute Frequency Measurement of Clock Transition in 87Sr
Authors:
A. Yamaguchi,
N. Shiga,
S. Nagano,
Y. Li,
H. Ishijima,
H. Hachisu,
M. Kumagai,
T. Ido
Abstract:
We demonstrated transferring the stability of one highly stable clock laser operating at 729 nm to another less stable laser operating at 698 nm. The two different wavelengths were bridged using an optical frequency comb. The improved stability of the clock laser at 698 nm enabled us to evaluate the systematic frequency shifts of the Sr optical lattice clock with shorter averaging time. We determi…
▽ More
We demonstrated transferring the stability of one highly stable clock laser operating at 729 nm to another less stable laser operating at 698 nm. The two different wavelengths were bridged using an optical frequency comb. The improved stability of the clock laser at 698 nm enabled us to evaluate the systematic frequency shifts of the Sr optical lattice clock with shorter averaging time. We determined the absolute frequency of the clock transition 1S0 - 3P0 in 87Sr to be 429 228 004 229 873.9 (1.4) Hz referenced to the SI second on the geoid via International Atomic Time (TAI).
△ Less
Submitted 16 January, 2012;
originally announced January 2012.
-
All-optical link for direct comparison of distant optical clocks
Authors:
Miho Fujieda,
Motohiro Kumagai,
Shigeo Nagano,
Atsushi Yamaguchi,
Hidekazu Hachisu,
Tetsuya Ido
Abstract:
We developed an all-optical link system for making remote comparisons of two distant ultra-stable optical clocks. An optical carrier transfer system based on a fiber interferometer was employed to compensate the phase noise accumulated during the propagation through a fiber link. Transfer stabilities of $2\times10^{-15}$ at 1 second and $4\times10^{-18}$ at 1000 seconds were achieved in a 90-km li…
▽ More
We developed an all-optical link system for making remote comparisons of two distant ultra-stable optical clocks. An optical carrier transfer system based on a fiber interferometer was employed to compensate the phase noise accumulated during the propagation through a fiber link. Transfer stabilities of $2\times10^{-15}$ at 1 second and $4\times10^{-18}$ at 1000 seconds were achieved in a 90-km link. An active polarization control system was additionally introduced to maintain the transmitted light in an adequate polarization, and consequently, a stable and reliable comparison was accomplished. The instabilities of the all-optical link system, including those of the erbium doped fiber amplifiers (EDFAs) which are free from phase-noise compensation, were below $2\times10^{-15}$ at 1 second and $7\times10^{-17}$ at 1000 seconds. The system was available for the direct comparison of two distant $^{87}$Sr lattice clocks via an urban fiber link of 60 km. This technique will be essential for the measuring the reproducibility of optical frequency standards.
△ Less
Submitted 13 August, 2011;
originally announced August 2011.
-
Direct Comparison of Distant Optical Lattice Clocks at the $10^{-16}$ Uncertainty
Authors:
Atsushi Yamaguchi,
Miho Fujieda,
Motohiro Kumagai,
Hidekazu Hachisu,
Shigeo Nagano,
Ying Li,
Tetsuya Ido,
Tetsushi Takano,
Masao Takamoto,
Hidetoshi Katori
Abstract:
Fiber-based remote comparison of $^{87}$Sr lattice clocks in 24 km distant laboratories is demonstrated. The instability of the comparison reaches $5\times10^{-16}$ over an averaging time of 1000 s, which is two orders of magnitude shorter than that of conventional satellite links and is limited by the instabilities of the optical clocks. By correcting the systematic shifts that are predominated b…
▽ More
Fiber-based remote comparison of $^{87}$Sr lattice clocks in 24 km distant laboratories is demonstrated. The instability of the comparison reaches $5\times10^{-16}$ over an averaging time of 1000 s, which is two orders of magnitude shorter than that of conventional satellite links and is limited by the instabilities of the optical clocks. By correcting the systematic shifts that are predominated by the differential gravitational redshift, the residual fractional difference is found to be $(1.0\pm7.3)\times10^{-16}$, confirming the coincidence between the two clocks. The accurate and speedy comparison of distant optical clocks paves the way for a future optical redefinition of the second.
△ Less
Submitted 13 August, 2011;
originally announced August 2011.
-
Buffer gas induced collision shift for the $^{88}$Sr $\bf{^1S_0-^3P_1}$ clock transition
Authors:
Nobuyasu Shiga,
Ying Li,
Hiroyuki Ito,
Shigeo Nagano,
Tetsuya Ido,
Katarzyna Bielska,
Ryszard S. Trawiński,
Roman Ciuryło
Abstract:
Precision saturation spectroscopy of the $^{88}{\rm Sr} ^1S_0-^3P_1$ is performed in a vapor cell filled with various rare gas including He, Ne, Ar, and Xe. By continuously calibrating the absolute frequency of the probe laser, buffer gas induced collision shifts of $\sim $kHz are detected with gas pressure of 1-20 mTorr. Helium gave the largest fractional shift of…
▽ More
Precision saturation spectroscopy of the $^{88}{\rm Sr} ^1S_0-^3P_1$ is performed in a vapor cell filled with various rare gas including He, Ne, Ar, and Xe. By continuously calibrating the absolute frequency of the probe laser, buffer gas induced collision shifts of $\sim $kHz are detected with gas pressure of 1-20 mTorr. Helium gave the largest fractional shift of $1.6 \times 10^{-9} {\rm Torr}^{-1}$. Comparing with a simple impact calculation and a Doppler-limited experiment of Holtgrave and Wolf [Phys. Rev. A {\bf 72}, 012711 (2005)], our results show larger broadening and smaller shifting coefficient, indicating effective atomic loss due to velocity changing collisions. The applicability of the result to the $^1S_0-^3P_0$ optical lattice clock transition is also discussed.
△ Less
Submitted 5 July, 2009;
originally announced July 2009.
-
$^{87}$Sr lattice clock with inaccuracy below 10$^{-15}$
Authors:
Martin M. Boyd,
Andrew D. Ludlow,
Sebastian Blatt,
Seth M. Foreman,
Tetsuya Ido,
Tanya Zelevinsky,
Jun Ye
Abstract:
Aided by ultra-high resolution spectroscopy, the overall systematic uncertainty of the $^{1}S_{0}$-$^{3}P_{0}$ clock resonance for lattice-confined $^{87}$Sr has been characterized to $9\times10^{-16}$. This uncertainty is at a level similar to the Cs-fountain primary standard, while the potential stability for the lattice clocks exceeds that of Cs. The absolute frequency of the clock transition…
▽ More
Aided by ultra-high resolution spectroscopy, the overall systematic uncertainty of the $^{1}S_{0}$-$^{3}P_{0}$ clock resonance for lattice-confined $^{87}$Sr has been characterized to $9\times10^{-16}$. This uncertainty is at a level similar to the Cs-fountain primary standard, while the potential stability for the lattice clocks exceeds that of Cs. The absolute frequency of the clock transition has been measured to be 429,228,004,229,874.0(1.1) Hz, where the $2.5\times10^{-15}$ fractional uncertainty represents the most accurate measurement of a neutral-atom-based optical transition frequency to date.
△ Less
Submitted 7 November, 2006;
originally announced November 2006.
-
Optical atomic coherence at the one-second time scale
Authors:
Martin M. Boyd,
Tanya Zelevinsky,
Andrew D. Ludlow,
Seth M. Foreman,
Sebastian Blatt,
Tetsuya Ido,
Jun Ye
Abstract:
Highest resolution laser spectroscopy has generally been limited to single trapped ion systems due to rapid decoherence which plagues neutral atom ensembles. Here, precision spectroscopy of ultracold neutral atoms confined in a trap** potential shows superior optical coherence without any deleterious effects from motional degrees of freedom, revealing optical resonance linewidths at the hertz…
▽ More
Highest resolution laser spectroscopy has generally been limited to single trapped ion systems due to rapid decoherence which plagues neutral atom ensembles. Here, precision spectroscopy of ultracold neutral atoms confined in a trap** potential shows superior optical coherence without any deleterious effects from motional degrees of freedom, revealing optical resonance linewidths at the hertz level with an excellent signal to noise ratio. The resonance quality factor of 2.4 x 10^{14} is the highest ever recovered in any form of coherent spectroscopy. The spectral resolution permits direct observation of the breaking of nuclear spin degeneracy for the 1S0 and 3P0 optical clock states of 87Sr under a small magnetic bias field. This optical NMR-like approach allows an accurate measurement of the differential Lande g-factor between the two states. The optical atomic coherence demonstrated for collective excitation of a large number of atoms will have a strong impact on quantum measurement and precision frequency metrology.
△ Less
Submitted 12 October, 2006;
originally announced October 2006.
-
Narrow Line Photoassociation in an Optical Lattice
Authors:
T. Zelevinsky,
M. M. Boyd,
A. D. Ludlow,
T. Ido,
J. Ye,
R. Ciurylo,
P. Naidon,
P. S. Julienne
Abstract:
With ultracold $^{88}$Sr in a 1D magic wavelength optical lattice, we performed narrow line photoassociation spectroscopy near the $^1$S$_0 - ^3$P$_1$ intercombination transition. Nine least-bound vibrational molecular levels associated with the long-range $0_u$ and $1_u$ potential energy surfaces were measured and identified. A simple theoretical model accurately describes the level positions a…
▽ More
With ultracold $^{88}$Sr in a 1D magic wavelength optical lattice, we performed narrow line photoassociation spectroscopy near the $^1$S$_0 - ^3$P$_1$ intercombination transition. Nine least-bound vibrational molecular levels associated with the long-range $0_u$ and $1_u$ potential energy surfaces were measured and identified. A simple theoretical model accurately describes the level positions and treats the effects of the lattice confinement on the line shapes. The measured resonance strengths show that optical tuning of the ground state scattering length should be possible without significant atom loss.
△ Less
Submitted 20 February, 2006;
originally announced February 2006.
-
Systematic study of the $^{87}$Sr clock transition in an optical lattice
Authors:
Andrew D. Ludlow,
Martin M. Boyd,
T. Zelevinsky,
Seth M. Foreman,
Sebastian Blatt,
Mark Notcutt,
Tetsuya Ido,
Jun Ye
Abstract:
With ultracold $^{87}$Sr confined in a magic wavelength optical lattice, we present the most precise study (2.8 Hz statistical uncertainty) to-date of the $^1S_0$ - $^3P_0$ optical clock transition with a detailed analysis of systematic shifts (20 Hz uncertainty) in the absolute frequency measurement of 429 228 004 229 867 Hz. The high resolution permits an investigation of the optical lattice m…
▽ More
With ultracold $^{87}$Sr confined in a magic wavelength optical lattice, we present the most precise study (2.8 Hz statistical uncertainty) to-date of the $^1S_0$ - $^3P_0$ optical clock transition with a detailed analysis of systematic shifts (20 Hz uncertainty) in the absolute frequency measurement of 429 228 004 229 867 Hz. The high resolution permits an investigation of the optical lattice motional sideband structure. The local oscillator for this optical atomic clock is a stable diode laser with its Hz-level linewidth characterized across the optical spectrum using a femtosecond frequency comb.
△ Less
Submitted 5 August, 2005;
originally announced August 2005.
-
A high-accuracy optical clock via three-level coherence in neutral bosonic $^{88}$Sr
Authors:
Robin Santra,
Ennio Arimondo,
Tetsuya Ido,
Chris H. Greene,
Jun Ye
Abstract:
An optical atomic clock scheme is developed that utilizes two lasers to establish coherent coupling between the $5s^2 \phantom{}^1S_0$ ground state of $^{88}$Sr and the first excited state, $5s5p \phantom{}^3P_0$. The coupling is mediated by the broad $5s5p \phantom{}^1P_1$ state, exploiting the phenomenon of electromagnetically induced transparency. The effective linewidth of the clock transiti…
▽ More
An optical atomic clock scheme is developed that utilizes two lasers to establish coherent coupling between the $5s^2 \phantom{}^1S_0$ ground state of $^{88}$Sr and the first excited state, $5s5p \phantom{}^3P_0$. The coupling is mediated by the broad $5s5p \phantom{}^1P_1$ state, exploiting the phenomenon of electromagnetically induced transparency. The effective linewidth of the clock transition can be chosen at will by adjusting the laser intensity. By trap** the $^{88}$Sr atoms in an optical lattice, long interaction times with the two lasers are ensured; Doppler and recoil effects are eliminated. Based on a careful analysis of systematic errors, a clock accuracy of better than $2\times 10^{-17}$ is expected.
△ Less
Submitted 20 November, 2004;
originally announced November 2004.
-
Precision spectroscopy and density-dependent frequency shifts in ultracold Sr
Authors:
Tetsuya Ido,
Thomas H. Loftus,
Martin M. Boyd,
Andrew D. Ludlow,
Kevin W. Holman,
Jun Ye
Abstract:
By varying the density of an ultracold $^{88}$Sr sample from $10^9$ cm$^{-3}$ to $> 10^{12}$ cm$^{-3}$, we make the first definitive measurement of the density-related frequency shift and linewidth broadening of the $^1S_0$ - $^3P_1$ optical clock transition in an alkaline earth system. In addition, we report the most accurate measurement to date of the $^{88}$Sr $^1S_0 - ^3P_1$ optical clock tr…
▽ More
By varying the density of an ultracold $^{88}$Sr sample from $10^9$ cm$^{-3}$ to $> 10^{12}$ cm$^{-3}$, we make the first definitive measurement of the density-related frequency shift and linewidth broadening of the $^1S_0$ - $^3P_1$ optical clock transition in an alkaline earth system. In addition, we report the most accurate measurement to date of the $^{88}$Sr $^1S_0 - ^3P_1$ optical clock transition frequency. Including a detailed analysis of systematic errors, the frequency is ($434 829 121 312 334 \pm 20_{stat} \pm 33_{sys}$) Hz.
△ Less
Submitted 21 January, 2005; v1 submitted 15 October, 2004;
originally announced October 2004.
-
Narrow Line Cooling and Momentum-Space Crystals
Authors:
Thomas H. Loftus,
Tetsuya Ido,
Martin M. Boyd,
Andrew D. Ludlow,
Jun Ye
Abstract:
Narrow line laser cooling is advancing the frontier for experiments ranging from studies of fundamental atomic physics to high precision optical frequency standards. In this paper, we present an extensive description of the systems and techniques necessary to realize 689 nm 1S0 - 3P1 narrow line cooling of atomic 88Sr. Narrow line cooling and trap** dynamics are also studied in detail. By cont…
▽ More
Narrow line laser cooling is advancing the frontier for experiments ranging from studies of fundamental atomic physics to high precision optical frequency standards. In this paper, we present an extensive description of the systems and techniques necessary to realize 689 nm 1S0 - 3P1 narrow line cooling of atomic 88Sr. Narrow line cooling and trap** dynamics are also studied in detail. By controlling the relative size of the power broadened transition linewidth and the single-photon recoil frequency shift, we show that it is possible to continuously bridge the gap between semiclassical and quantum mechanical cooling. Novel semiclassical cooling process, some of which are intimately linked to gravity, are also explored. Moreover, for laser frequencies tuned above the atomic resonance, we demonstrate momentum-space crystals containing up to 26 well defined lattice points. Gravitationally assisted cooling is also achieved with blue-detuned light. Theoretically, we find the blue detuned dynamics are universal to Doppler limited systems. This paper offers the most comprehensive study of narrow line laser cooling to date.
△ Less
Submitted 2 July, 2004;
originally announced July 2004.
-
Narrow Line Cooling: Finite Photon Recoil Dynamics
Authors:
Thomas H. Loftus,
Tetsuya Ido,
Andrew D. Ludlow,
Martin M. Boyd,
Jun Ye
Abstract:
We present an extensive study of the unique thermal and mechanical dynamics for narrow-line cooling on the 1S0 - 3P1 88Sr transition. For negative detuning, trap dynamics reveal a transition from the semiclassical regime to the photon-recoil-dominated quantum regime, yielding an absolute minima in the equilibrium temperature below the single-photon recoil limit. For positive detuning, the cloud…
▽ More
We present an extensive study of the unique thermal and mechanical dynamics for narrow-line cooling on the 1S0 - 3P1 88Sr transition. For negative detuning, trap dynamics reveal a transition from the semiclassical regime to the photon-recoil-dominated quantum regime, yielding an absolute minima in the equilibrium temperature below the single-photon recoil limit. For positive detuning, the cloud divides into discrete momentum packets whose alignment mimics lattice points on a face-centered-cubic crystal. This novel behavior arises from velocity selection and "positive feedback" acceleration due to a finite number of photon recoils. Cooling is achieved with blue-detuned light around a velocity where gravity balances the radiative force.
△ Less
Submitted 9 July, 2004; v1 submitted 12 January, 2004;
originally announced January 2004.
-
Recoil-free spectroscopy of neutral Sr atoms in the Lamb-Dicke regime
Authors:
Tetsuya Ido,
Hidetoshi Katori
Abstract:
We have demonstrated a recoil-free spectroscopy on the ${}^1S_0-{}^3P_1$ transition of strontium atoms confined in a one-dimensional optical lattice. By investigating the wavelength and polarization dependence of the ac Stark shift acting on the ${}^1S_0$ and ${}^3P_1(m_J=0)$ states, we determined the {\it magic wavelength} where the Stark shifts for both states coincide. The Lamb-Dicke confinem…
▽ More
We have demonstrated a recoil-free spectroscopy on the ${}^1S_0-{}^3P_1$ transition of strontium atoms confined in a one-dimensional optical lattice. By investigating the wavelength and polarization dependence of the ac Stark shift acting on the ${}^1S_0$ and ${}^3P_1(m_J=0)$ states, we determined the {\it magic wavelength} where the Stark shifts for both states coincide. The Lamb-Dicke confinement provided by this Stark-free optical lattice enabled the measurement of the atomic spectrum free from Doppler as well as recoil shifts.
△ Less
Submitted 8 March, 2003;
originally announced March 2003.
-
Anomalous Hall Effect and Magnetoresistance of SrFe1-xCoxO3-d
Authors:
Takahiko Ido,
Yukio Yasui,
Masatoshi Sato
Abstract:
Transport and magnetic studies on polycrystalline samples of SrFe1-xCoxO3-d have been carried out to investigate the relationship between the magnetic structure and the anomalous Hall resistivity rH. The hysteretic behavior of the magnetization observed in the measurements with varying temperature T up and then down after zero field cooling indicates that the system has the reentrant spin-glass…
▽ More
Transport and magnetic studies on polycrystalline samples of SrFe1-xCoxO3-d have been carried out to investigate the relationship between the magnetic structure and the anomalous Hall resistivity rH. The hysteretic behavior of the magnetization observed in the measurements with varying temperature T up and then down after zero field cooling indicates that the system has the reentrant spin-glass phase, which is supported by the increasing width of the magnetic reflections observed by neutron diffraction with decreasing T below the Curie temperature TC. Detailed analyses of the observed Hall resistivity rH indicate that the anomalous Hall coefficient exhibits unusual behavior in the reentrant spin-glass phase. The magnetic field (H)- and T-dependence of the magnetoresistance of the present system can be understood by a spin dependent tunneling model.
△ Less
Submitted 21 February, 2003;
originally announced February 2003.