-
First Flight Performance of the Micro-X Microcalorimeter X-Ray Sounding Rocket
Authors:
Joseph S. Adams,
Robert Baker,
Simon R. Bandler,
Noemie Bastidon,
Daniel Castro,
Meredith E. Danowksi,
William B. Doriese,
Megan E. Eckart,
Enectali Figueroa-Feliciano,
Joshua Fuhrman,
David C. Goldfinger,
Sarah N. T. Heine,
Gene Hilton,
Antonia J. F. Hubbard,
Daniel Jardin,
Richard L. Kelley,
Caroline A. Kilbourne,
Steven W. Leman,
Renee E. Manzagol-Harwood,
Dan McCammon,
Philip H. H. Oakley,
Takashi Okajima,
Frederick Scott Porter,
Carl D. Reintsema,
John Rutherford
, et al. (6 additional authors not shown)
Abstract:
The flight of the Micro-X sounding rocket on July 22, 2018 marked the first operation of Transition-Edge Sensors and their SQUID readouts in space. The instrument combines the microcalorimeter array with an imaging mirror to take high-resolution spectra from extended X-ray sources. The first flight target was the Cassiopeia~A Supernova Remnant. While a rocket pointing malfunction led to no time on…
▽ More
The flight of the Micro-X sounding rocket on July 22, 2018 marked the first operation of Transition-Edge Sensors and their SQUID readouts in space. The instrument combines the microcalorimeter array with an imaging mirror to take high-resolution spectra from extended X-ray sources. The first flight target was the Cassiopeia~A Supernova Remnant. While a rocket pointing malfunction led to no time on-target, data from the flight was used to evaluate the performance of the instrument and demonstrate the flight viability of the payload. The instrument successfully achieved a stable cryogenic environment, executed all flight operations, and observed X-rays from the on-board calibration source. The flight environment did not significantly affect the performance of the detectors compared to ground operation. The flight provided an invaluable test of the impact of external magnetic fields and the instrument configuration on detector performance. This flight provides a milestone in the flight readiness of these detector and readout technologies, both of which have been selected for future X-ray observatories.
△ Less
Submitted 22 December, 2022;
originally announced December 2022.
-
Radioactivity induced dark count rate for single near-infrared photon detection with a tungsten transition edge sensor at 80 mK
Authors:
N. Bastidon,
D. Horns
Abstract:
The intrinsic background count rate of tungsten superconducting transition-edge sensors (TES) is low, and the calorimeters using these sensors can resolve the energy of single photons. These facts make the sensors particularly interesting for the background-limited searches of new processes and particles. In this contribution, the intrinsic background of a tungsten TES has been investigated. After…
▽ More
The intrinsic background count rate of tungsten superconducting transition-edge sensors (TES) is low, and the calorimeters using these sensors can resolve the energy of single photons. These facts make the sensors particularly interesting for the background-limited searches of new processes and particles. In this contribution, the intrinsic background of a tungsten TES has been investigated. After excluding other sources (e.g., cosmic muons, thermal background) relevant for the observed background rate of $10^{-4}$~s$^{-1}$ for the detection of photons with a wave length of 1064 nm, we investigate the impact of natural radioactivity. Dedicated measurements using gamma-emitters mounted outside the cryostat have been used to estimate the sensitivity of the TES setup for ionizing radiation. We have found that indeed an increased background can be observed in the presence of the radioactive sources. After selecting events which populate our signal region tuned for single photon detection at near-infrared, roughly 0.5% of the events produced by gamma-rays appear indistinguishable from those due to single photons with 1064~nm wave length. This ratio is consistent with that observed for the residual background detected with the TES at a rate of $10^{-4}$~s$^{-1}$. From this, we conclude that the bulk of the observed background count-rate in the signal region can be explained by natural radioactivity.
△ Less
Submitted 29 June, 2022;
originally announced June 2022.
-
Micro-X Sounding Rocket Payload Re-flight Progress
Authors:
J. S. Adams,
S. R. Bandler,
N. Bastidon,
M. E. Eckart,
E. Figueroa-Feliciano,
J. Fuhrman,
D. C. Goldfinger,
A. J. F. Hubbard,
D. Jardin,
R. L. Kelley,
C. A. Kilbourne,
R. E. Manzagol-Harwood,
D. McCammon,
T. Okajima,
F. S. Porter,
C. D. Reintsema,
S. J. Smith
Abstract:
Micro-X is an X-ray sounding rocket payload that had its first flight on July 22, 2018. The goals of the first flight were to operate a transition edge sensor (TES) X-ray microcalorimeter array in space and take a high-resolution spectrum of the Cassiopeia A supernova remnant. The first flight was considered a partial success. The array and its time-division multiplexing readout system were succes…
▽ More
Micro-X is an X-ray sounding rocket payload that had its first flight on July 22, 2018. The goals of the first flight were to operate a transition edge sensor (TES) X-ray microcalorimeter array in space and take a high-resolution spectrum of the Cassiopeia A supernova remnant. The first flight was considered a partial success. The array and its time-division multiplexing readout system were successfully operated in space, but due to a failure in the attitude control system, no time on-target was acquired. A re-flight has been scheduled for summer 2022. Since the first flight, modifications have been made to the detector systems to improve noise and reduce the susceptibility to magnetic fields. The three-stage SQUID circuit, NIST MUX06a, has been replaced by a two-stage SQUID circuit, NIST MUX18b. The initial laboratory results for the new detector system will be presented in this paper.
△ Less
Submitted 12 November, 2021;
originally announced November 2021.
-
Modeling a Three-Stage SQUID System in Space with the First Micro-X Sounding Rocket Flight
Authors:
J. S. Adams,
S. R. Bandler,
N. Bastidon,
M. E. Eckart,
E. Figueroa-Feliciano,
J. Fuhrman,
D. C. Goldfinger,
A. J. F. Hubbard,
D. Jardin,
R. L. Kelley,
C. A. Kilbourne,
R. E. Manzagol-Harwood,
D. McCammon,
T. Okajima,
F. S. Porter,
C. D. Reintsema,
S. J. Smith
Abstract:
The Micro-X sounding rocket is a NASA funded X-ray telescope payload that completed its first flight on July 22, 2018. This event marked the first operation of Transition Edge Sensors (TESs) and their SQUID-based multiplexing readout system in space. Unfortunately, due to an ACS pointing failure, the rocket was spinning during its five minute observation period and no scientific data was collected…
▽ More
The Micro-X sounding rocket is a NASA funded X-ray telescope payload that completed its first flight on July 22, 2018. This event marked the first operation of Transition Edge Sensors (TESs) and their SQUID-based multiplexing readout system in space. Unfortunately, due to an ACS pointing failure, the rocket was spinning during its five minute observation period and no scientific data was collected. However, data collected from the internal calibration source marked a partial success for the payload and offers a unique opportunity to study the response of TESs and SQUIDs in space. Of particular interest is the magnetic field response of the NIST MUX06a SQUID readout system to tumbling through Earth's magnetic field. We present a model to explain the baseline response of the SQUIDs, which lead to a subset of pixels failing to "lock" for the full observational period. Future flights of the Micro-X rocket will include the NIST MUX18b SQUID system with dramatically reduced magnetic susceptibility.
△ Less
Submitted 11 November, 2021;
originally announced November 2021.
-
First operation of Transition-Edge Sensors in space with the Micro-X sounding rocket
Authors:
J. S. Adams,
R. Baker,
S. R. Bandler,
N. Bastidon,
M. E. Danowski,
W. B. Doriese,
M. E. Eckart,
E. Figueroa-Feliciano,
J. Fuhrman,
D. C. Goldfinger,
S. N. T. Heine,
G. C. Hilton,
A. J. F. Hubbard,
D. Jardin,
R. L. Kelley,
C. A. Kilbourne,
R. E. Manzagol-Harwood,
D. McCammon,
T. Okajima,
F. S. Porter,
C. D. Reintsema,
P. Serlemitsos,
S. J. Smith,
P. Wikus
Abstract:
With its first flight in 2018, Micro-X became the first program to fly Transition-Edge Sensors and their SQUID readouts in space. The science goal was a high-resolution, spatially resolved X-ray spectrum of the Cassiopeia A Supernova Remnant. While a rocket pointing error led to no time on target, the data was used to demonstrate the flight performance of the instrument. The detectors observed X-r…
▽ More
With its first flight in 2018, Micro-X became the first program to fly Transition-Edge Sensors and their SQUID readouts in space. The science goal was a high-resolution, spatially resolved X-ray spectrum of the Cassiopeia A Supernova Remnant. While a rocket pointing error led to no time on target, the data was used to demonstrate the flight performance of the instrument. The detectors observed X-rays from the on-board calibration source, but a susceptibility to external magnetic fields limited their livetime. Accounting for this, no change was observed in detector response between ground operation and flight operation. This paper provides an overview of the first flight performance and focuses on the upgrades made in preparation for reflight. The largest changes have been upgrading the SQUIDs to mitigate magnetic susceptibility, synchronizing the clocks on the digital electronics to minimize beat frequencies, and replacing the mounts between the cryostat and the rocket skin to improve mechanical integrity. As the first flight performance was consistent with performance on the ground, reaching the instrument goals in the laboratory is considered a strong predictor of future flight performance.
△ Less
Submitted 3 March, 2021;
originally announced March 2021.
-
First Operation of TES Microcalorimeters in Space with the Micro-X Sounding Rocket
Authors:
J. S. Adams,
R. Baker,
S. R. Bandler,
N. Bastidon,
M. E. Danowski,
W. B. Doriese,
M. E. Eckart,
E. Figueroa-Feliciano,
D. C. Goldfinger,
S. N. T. Heine,
G. C. Hilton,
A. J. F. Hubbard,
R. L. Kelley,
C. A. Kilbourne,
R. E. Manzagol-Harwood,
D. McCammon,
T. Okajima,
F. S. Porter,
C. D. Reintsema,
P. Serlemitsos,
S. J. Smith,
J. N. Ullom,
P. Wikus
Abstract:
Micro-X is a sounding rocket-borne instrument that uses a microcalorimeter array to perform high-resolution X-ray spectroscopy. This instrument flew for the first time on July 22nd, 2018 from the White Sands Missile Range, USA. This flight marks the first successful operation of a Transition-Edge Sensor array and its time division multiplexing read-out system in space. This launch was dedicated to…
▽ More
Micro-X is a sounding rocket-borne instrument that uses a microcalorimeter array to perform high-resolution X-ray spectroscopy. This instrument flew for the first time on July 22nd, 2018 from the White Sands Missile Range, USA. This flight marks the first successful operation of a Transition-Edge Sensor array and its time division multiplexing read-out system in space. This launch was dedicated to the observation of the supernova remnant Cassiopeia A. A failure in the attitude control system prevented the rocket from pointing and led to no time on target. The on-board calibration source provided X-rays in flight, and it is used to compare detector performance during pre-flight integration, flight, and after the successful post-flight recovery. This calibration data demonstrates the capabilities of the detector in a space environment as well as its potential for future flights.
△ Less
Submitted 5 January, 2020; v1 submitted 26 August, 2019;
originally announced August 2019.
-
Micro-X Sounding Rocket: Transitioning from First Flight to a Dark Matter Configuration
Authors:
J. S. Adams,
A. J. Anderson,
R. Baker,
S. R. Bandler,
N. Bastidon,
D. Castro,
M. E. Danowski,
W. B. Doriese,
M. E. Eckart,
E. Figueroa-Feliciano,
D. C. Goldfinger,
S. N. T. Heine,
G. C. Hilton,
A. J. F. Hubbard,
R. L. Kelley,
C. A. Kilbourne,
R. E. Manzagol-Harwood,
D. McCammon,
T. Okajima,
F. S. Porter,
C. D. Reintsema,
P. Serlemitsos,
S. J. Smith,
P. Wikus
Abstract:
The Micro-X sounding rocket flew for the first time on July 22, 2018, becoming the first program to fly Transition-Edge Sensors and multiplexing SQUID readout electronics in space. While a rocket pointing failure led to no time on-target, the success of the flight systems was demonstrated. The successful flight operation of the instrument puts the program in a position to modify the payload for in…
▽ More
The Micro-X sounding rocket flew for the first time on July 22, 2018, becoming the first program to fly Transition-Edge Sensors and multiplexing SQUID readout electronics in space. While a rocket pointing failure led to no time on-target, the success of the flight systems was demonstrated. The successful flight operation of the instrument puts the program in a position to modify the payload for indirect galactic dark matter searches. The payload modifications are motivated by the science requirements of this observation. Micro-X can achieve world-leading sensitivity in the keV regime with a single flight. Dark matter sensitivity projections have been updated to include recent observations and the expected sensitivity of Micro-X to these observed fluxes. If a signal is seen (as seen in the X-ray satellites), Micro-X can differentiate an atomic line from a dark matter signature.
△ Less
Submitted 30 January, 2020; v1 submitted 22 August, 2019;
originally announced August 2019.
-
US Cosmic Visions: New Ideas in Dark Matter 2017: Community Report
Authors:
Marco Battaglieri,
Alberto Belloni,
Aaron Chou,
Priscilla Cushman,
Bertrand Echenard,
Rouven Essig,
Juan Estrada,
Jonathan L. Feng,
Brenna Flaugher,
Patrick J. Fox,
Peter Graham,
Carter Hall,
Roni Harnik,
JoAnne Hewett,
Joseph Incandela,
Eder Izaguirre,
Daniel McKinsey,
Matthew Pyle,
Natalie Roe,
Gray Rybka,
Pierre Sikivie,
Tim M. P. Tait,
Natalia Toro,
Richard Van De Water,
Neal Weiner
, et al. (226 additional authors not shown)
Abstract:
This white paper summarizes the workshop "U.S. Cosmic Visions: New Ideas in Dark Matter" held at University of Maryland on March 23-25, 2017.
This white paper summarizes the workshop "U.S. Cosmic Visions: New Ideas in Dark Matter" held at University of Maryland on March 23-25, 2017.
△ Less
Submitted 14 July, 2017;
originally announced July 2017.
-
Any Light Particle Search II - Status Overview
Authors:
Noemie Bastidon
Abstract:
The Any Light Particle Search II (ALPS II) experiment (DESY, Hamburg) searches for photon oscillations into Weakly Interacting Sub-eV Particles (WISPs). This second generation of the ALPS light-shining-through-a-wall (LSW) experiment approaches the finalization of the preparation phase before ALPS IIa (search for hidden photons). In the last years, efforts have been put for the setting up of two o…
▽ More
The Any Light Particle Search II (ALPS II) experiment (DESY, Hamburg) searches for photon oscillations into Weakly Interacting Sub-eV Particles (WISPs). This second generation of the ALPS light-shining-through-a-wall (LSW) experiment approaches the finalization of the preparation phase before ALPS IIa (search for hidden photons). In the last years, efforts have been put for the setting up of two optical cavities as well as characterization of a single-photon Transition-Edge Sensor (TES) detector. In the following, we put some emphasis on the detector development. In parallel, the setting up of ALPS IIc (search for axion-like particles), including the unbending of 20 HERA dipoles, has been pursued. The latest progress in these tasks will be discussed.
△ Less
Submitted 7 September, 2015;
originally announced September 2015.
-
Characterization of a Transition-Edge Sensor for the ALPS II Experiment
Authors:
Noemie Bastidon,
Dieter Horns,
Axel Lindner
Abstract:
The ALPS II experiment, Any Light Particle Search II at DESY in Hamburg, will look for light (m< 10-4 eV) new fundamental bosons (e.g., axion-like particles, hidden photons and other WISPs) in the next years by the mean of a light-shining-through-the-wall setup. The ALPS II photosensor is a Transition-Edge Sensor (TES) optimized for lambda = 1064 nm photons. The detector is routinely operated at 8…
▽ More
The ALPS II experiment, Any Light Particle Search II at DESY in Hamburg, will look for light (m< 10-4 eV) new fundamental bosons (e.g., axion-like particles, hidden photons and other WISPs) in the next years by the mean of a light-shining-through-the-wall setup. The ALPS II photosensor is a Transition-Edge Sensor (TES) optimized for lambda = 1064 nm photons. The detector is routinely operated at 80 mK, allowing single infrared photon detections as well as non-dispersive spectroscopy with very low background rates. The demonstrated quantum efficiency for such TES is up to 95% at lambda =1064 nm. For 1064 nm photons, the measured background rate is < 10-2 sec-1 and the intrinsic dark count rate in a dark environment was found to be of 1,0.10-4 sec-1. Latest characterization results are discussed.
△ Less
Submitted 7 September, 2015;
originally announced September 2015.
-
Characterization, 1064 nm photon signals and background events of a tungsten TES detector for the ALPS experiment
Authors:
Jan Dreyling-Eschweiler,
Noemie Bastidon,
Babette Döbrich,
Dieter Horns,
Friederike Januschek,
Axel Lindner
Abstract:
The high efficiency, low-background, and single-photon detection with transition-edge sensors (TES) is making this type of detector attractive in widely different types of application. In this paper, we present first characterizations of a TES to be used in the Any Light Particle Search (ALPS) experiment searching for new fundamental ultra-light particles. Firstly, we describe the setup and the ma…
▽ More
The high efficiency, low-background, and single-photon detection with transition-edge sensors (TES) is making this type of detector attractive in widely different types of application. In this paper, we present first characterizations of a TES to be used in the Any Light Particle Search (ALPS) experiment searching for new fundamental ultra-light particles. Firstly, we describe the setup and the main components of the ALPS TES detector (TES, millikelvin-cryostat and SQUID read-out) and their performances. Secondly, we explain a dedicated analysis method for single-photon spectroscopy and rejection of non-photon background. Finally, we report on results from extensive background measurements. Considering an event-selection, optimized for a wavelength of $1064~{\rm nm}$, we achieved a background suppression of $\sim 10^{-3}$ with a $\sim 50~\%$ efficiency for photons passing the selection. The resulting overall efficiency was $23~\%$ with a dark count rate of $8.6 \cdot 10^{-3}~{\rm s}^{-1}$. We observed that pile-up events of thermal photons are the main background component.
△ Less
Submitted 27 February, 2015;
originally announced February 2015.