License: arXiv.org perpetual non-exclusive license
arXiv:2403.02587v1 [nucl-ex] 05 Mar 2024

[a]Debaditya Biswas

Future measurements of TCS at JLab Hall C

   Marie Boër
Abstract

Generalized parton Distributions (GPDs) are important functions to understand the three dimensional structure of the nucleon. Deeply Virtual Compton Scattering is one of the reaction accessing GPDs, and has been measured for the past similar-to\sim20 years. However, to move forward, we need to look for other reactions, such as Timelike Compton Scattering (TCS), its "time-reversal" equivalent. Indeed, accessing GPDs from both DVCS and TCS independently will allow us, for instance, to study their universality. Any assesment on GPD’s universality would be a milestone in our field. In this article we discuss our preliminary studies on the feasibility of measuring unpolarized and beam polarized cross sections and beam spin asymmetry for TCS in the dilepton photoproduction reaction. For that purpose, we use a polarized photon beam and an unpolarized target at JLab Hall C. We will discuss our Geant4 simulations, with a dedicated detector setup along with the use of the SBS magnet for separating outgoing e+superscript𝑒e^{+}italic_e start_POSTSUPERSCRIPT + end_POSTSUPERSCRIPT, esuperscript𝑒e^{-}italic_e start_POSTSUPERSCRIPT - end_POSTSUPERSCRIPT pairs.

1 Introduction

This article discuss our preliminary studies for measuring Timelike Compton Scattering (TCS, displayed Fig 1) at Jefferson Lab Hall C, off an unpolarized Liquid Hydrogen target and a circularly polarized high intensity photon beam. Measuring TCS cross sections and beam spin asymmetries with an unpolarized target, is very important to constrain the Generalized Parton Distribution (GPDs) [1, 2] . GPDs are sensitive to the longitudinal momentum versus transverse position structure of partons (quarks and gluons) in the nucleon [3]. They can’t be accessed directly from experiments: we are actually measuring functions of GPDs, called Compton Form Factors (CFFs). There are several GPDs corresponding to different possible relative orientations of the helicity of particles involved in the reaction [4]. In our case, the observables we aim to measure are most sensitive to the GPD "H", the one which is insensitive to the quark and to the nucleon’s helicities. GPD H is currently well constrained from DVCS measurements, and this is why we would like to obtain similar measurements from TCS, for a comparison, and for universality studies. Furthermore, GPDs are real functions, but CFFs that we are measuring are complex functions: from DVCS measurements, we better constrain the imaginary part of the CFFs. Our equivalent measurement with TCS is sensitive to both real and imaginary parts, and thus will bring more constraints on the real part of the amplitudes in a multi-channel CFF extraction approach. We refer to articles [5, 6] for the phenomenology of TCS off the proton and projections of observables.

Refer to caption
Figure 1: Time Like Compton Scattering (leading order and leading twist, CC not represented).

TCS is measured in the reaction γPe+eP𝛾𝑃superscript𝑒superscript𝑒superscript𝑃\gamma P\to e^{+}e^{-}P^{\prime}italic_γ italic_P → italic_e start_POSTSUPERSCRIPT + end_POSTSUPERSCRIPT italic_e start_POSTSUPERSCRIPT - end_POSTSUPERSCRIPT italic_P start_POSTSUPERSCRIPT ′ end_POSTSUPERSCRIPT, where P is a nucleon (a proton here) and e is a lepton (an electron here). It interferes with another process, called Bethe-Heitler (BH) where the lepton pair is produced by a splitting of the incoming photon in the nucleon’s field. BH is insensitive to the GPDs. It is parametrized by Form Factors. What we want to measure ("observables") is cross sections (σ𝜎\sigmaitalic_σ) and beam spin asymmetries (AUsubscript𝐴direct-productabsent𝑈A_{\odot U}italic_A start_POSTSUBSCRIPT ⊙ italic_U end_POSTSUBSCRIPT is mostly sensitive to the interference term in the TCS+BH amplitude). The beam spin asymmetry is defined as:

AU=σ+σσ++σ,subscript𝐴direct-productabsent𝑈superscript𝜎superscript𝜎superscript𝜎superscript𝜎A_{\odot U}=\frac{\sigma^{+}-\sigma^{-}}{\sigma^{+}+\sigma^{-}},italic_A start_POSTSUBSCRIPT ⊙ italic_U end_POSTSUBSCRIPT = divide start_ARG italic_σ start_POSTSUPERSCRIPT + end_POSTSUPERSCRIPT - italic_σ start_POSTSUPERSCRIPT - end_POSTSUPERSCRIPT end_ARG start_ARG italic_σ start_POSTSUPERSCRIPT + end_POSTSUPERSCRIPT + italic_σ start_POSTSUPERSCRIPT - end_POSTSUPERSCRIPT end_ARG , (1)

where direct-product\odot represents the beam polarization and U𝑈Uitalic_U represents the unpolarized target. +++, -- represents the right and left circularly polarized beam respectively. σ𝜎\sigmaitalic_σ is defined as the five differential polarized cross section, which reads

σ±d5σdQ2dtd(cosθ)dϕdEγ,superscript𝜎plus-or-minussuperscript𝑑5𝜎𝑑superscript𝑄2𝑑𝑡𝑑𝑐𝑜𝑠𝜃𝑑italic-ϕ𝑑subscript𝐸𝛾\sigma^{\pm}\equiv\frac{d^{5}\sigma}{dQ^{\prime 2}\ dt\ d(cos\theta)\ d\phi\ % dE_{\gamma}},italic_σ start_POSTSUPERSCRIPT ± end_POSTSUPERSCRIPT ≡ divide start_ARG italic_d start_POSTSUPERSCRIPT 5 end_POSTSUPERSCRIPT italic_σ end_ARG start_ARG italic_d italic_Q start_POSTSUPERSCRIPT ′ 2 end_POSTSUPERSCRIPT italic_d italic_t italic_d ( italic_c italic_o italic_s italic_θ ) italic_d italic_ϕ italic_d italic_E start_POSTSUBSCRIPT italic_γ end_POSTSUBSCRIPT end_ARG , (2)

where Q2superscript𝑄2Q^{\prime 2}italic_Q start_POSTSUPERSCRIPT ′ 2 end_POSTSUPERSCRIPT is the virtuality of the outgoing photon, t𝑡titalic_t is the squared momentum transfer (Mandelstam variable), θ𝜃\thetaitalic_θ and ϕitalic-ϕ\phiitalic_ϕ are the polar and azimuthal angles for the scattered electron in the virtual photon’s rest frame, relative to the proton-incoming photon’s frame. Eγsubscript𝐸𝛾E_{\gamma}italic_E start_POSTSUBSCRIPT italic_γ end_POSTSUBSCRIPT is the incoming beam energy.

In this paper, we will focus on our experimental setup for the measurement of unpolarized and beam polarized TCS+BH cross sections at JLab Hall C. Our setup is strongly inspired by a similar one, proposed to measure TCS+BH transverse target spin asymmetries off an ammonia target [7].

2 Experimental Setup

Refer to caption
Figure 2: The GEANT4 simulations for the experimental setup for an unpolarized TCS experiment. Q1, Q2, Q3 and Q4 designate four quadrants consisting of the same set of detectors. Each of the four quadrants consists of three layers of GEMs, 3 layers of hodoscopes and an electromagnetic calorimeter. The unpolarized liquid hydrogen target is inside the scattering chamber (on the left). The SBS magnet is shown in between the "quadrants" and the scattering chamber.

To measure unpolarized TCS cross sections at JLab Hall C, we need a dedicated experimental setup. A lot of studies were done for the equivalent polarized TCS case [7], therefore we are replicating part of that setup. Fig 2 shows our Geant4 simulations. The Compact Photon Source (CPS) [8] will be used to generate a high intensity (1012γ/secsimilar-toabsentsuperscript1012𝛾𝑠𝑒𝑐\sim 10^{12}\gamma/sec∼ 10 start_POSTSUPERSCRIPT 12 end_POSTSUPERSCRIPT italic_γ / italic_s italic_e italic_c circularly polarized photon beam. We are using a 15cm15𝑐𝑚15~{}cm15 italic_c italic_m long liquid hydrogen target, kept inside a scattering chamber. The outgoing particles are an electron, a positron and a recoil proton. To separate the outgoing esuperscript𝑒e^{-}italic_e start_POSTSUPERSCRIPT - end_POSTSUPERSCRIPT and e+superscript𝑒e^{+}italic_e start_POSTSUPERSCRIPT + end_POSTSUPERSCRIPT, we placed a magnet in front of the scattering chamber. Q1, Q2, Q3 and Q4 (in Fig. 2) designate four identical "quadrants": each of the four quadrants consists of three layers of GEMs, hodoscopes and electromagnetic calorimeter. For further details about the base setup, see [7]. The electromagnetic calorimeters in each quadrant correspond to 1/2similar-toabsent12\sim 1/2∼ 1 / 2 of the surface currently available from the Neutral Particle Spectrometer (NPS) [9], currently used in a DVCS experiment at JLab.

Refer to caption
Figure 3: The CPS cut-out side view. Deflected electrons strike a copper absorber, surrounded by a W-Cu insert inside the magnet yoke. The outer rectangular region in this view is the tungsten-powder shield.

2.1 Compact Photon Source (CPS)

The experiment will take advantage of the already approved Compact Photon Source (CPS) for the experiment E12-17-008 [10, 8], to get a pure circularly polarized photon beam. The conceptual design of the CPS is shown in Fig 3. The CPS can generate photons with a flux of 1.5×1012s11.5superscript1012superscript𝑠11.5\times 10^{12}~{}s^{-1}1.5 × 10 start_POSTSUPERSCRIPT 12 end_POSTSUPERSCRIPT italic_s start_POSTSUPERSCRIPT - 1 end_POSTSUPERSCRIPT with a 2.5μA2.5𝜇𝐴2.5~{}\mu A2.5 italic_μ italic_A electron beam, for photon energies >>>5 GeV. The expected spot size of the photon off the target is 1mmsimilar-toabsent1𝑚𝑚\sim 1~{}mm∼ 1 italic_m italic_m, at 2m2𝑚2~{}m2 italic_m distance of the CPS radiator. For more design details and working principle of CPS, we refer to [12].

Refer to caption
Figure 4: The Geant4 design of the 15cm15𝑐𝑚15~{}cm15 italic_c italic_m long liquid hydrogen, target placed inside the scattering chamber.

2.2 Target

For this experiment, an unpolarized liquid hydrigen target is needed. A 15cm long liquid hydrogen target of Hall C is used in this study. The liquid hydrogen is kept in a 15cm15𝑐𝑚15~{}cm15 italic_c italic_m long aluminum can, and can be seen in the middle of the scattering chamber, in Fig 4. More details about the target geometry can be found in [11]. The target is placed inside the scattering chamber, made of 2 inches thick aluminum wall. The horizontal angular range of the scattering window is from 3.2deg3.2degree3.2\deg3.2 roman_deg to 77.0deg77.0degree77.0~{}\deg77.0 roman_deg on the High Momentum Spectrometer (HMS, one of the "standard" Hall C detector equipment) side, and from 3.2deg3.2degree3.2\deg3.2 roman_deg to 47.0deg47.0degree47.0~{}\deg47.0 roman_deg on the Super High Momentum Spectrometer (SHMS, one of the "standard" Hall C detector equipment) side. The thickness of the aluminum for the scattering window is 0.02inches0.02𝑖𝑛𝑐𝑒𝑠0.02~{}inches0.02 italic_i italic_n italic_c italic_h italic_e italic_s.

Refer to caption
Figure 5: GEANT4 simulation for SBS magnet geometry.

2.3 Magnet

A simple magnet geometry is simulated in Geant4 and placed between the scattering chamber and the detector stack 5. The field strength is 2.4T-m2.4𝑇-𝑚2.4~{}T\text{-}m2.4 italic_T - italic_m along the x axis (red arrow in Fig 2), with 1.2m1.2𝑚1.2~{}m1.2 italic_m long pole as shown in Fig 5. What we eventually want will be to move the Super Big Bite Spectrometer (SBS) magnet from Jlab Hall A into the Hall C, after their experiments. Therefore, we is designed our magnet according to the SBS magnet geometry. We are looking into the possibility of reusing magnets from other experiments as well, to help in cutting the cost of our experiment.

2.4 GEMs

For the reconstruction of the vertex parameters from the track coordinates at the detectors, tracker is needed for the experiment. For this purpose, we put 3 layers of GEMs in our simulations. The GEMs are very useful for the reconstruction of transverse tracks with certainty up to 100μm100𝜇𝑚100~{}\mu m100 italic_μ italic_m. The general knowledge about GEMs assures (compared to other methods of tracking) reliable track reconstruction in the background rates, which we expect to be relatively high (up to 106Hz/mmsuperscript106𝐻𝑧𝑚𝑚10^{6}Hz/mm10 start_POSTSUPERSCRIPT 6 end_POSTSUPERSCRIPT italic_H italic_z / italic_m italic_m in this experiment). We found that only 2 layers of the GEMs could be enough for the determination of the positions and directions of the tracks, but we decided to put three layers to ensure it’s performance in the high background rates and a better particle identification (see studies in [7]).

2.5 Hodoscopes

The detection of recoil protons requires is essential in this experiment, because we are using an untagged photon beam from CPS, therefore are missing it’s energy. Indeed, the scattered electron from the primary CEBAF beam is dumped into the CPS magnet. Our secondary photon beam ranges from 5.5similar-toabsent5.5\sim 5.5∼ 5.5 to 11similar-toabsent11\sim 11∼ 11 GeV. We know it’s direction (very low scattering angle), but not it’s exact energy. This is why, for an exclusive measurement such as TCS, we need to detect absolutely all the outgoing particles. The detection of the protons requires fly’s-eye array of scintillators in each of the detector quadrants. The scintillators will be placed just before the NPS calorimeters, and the light sensors need to be coupled at the rear side of the scintillators. Our preliminary results show an optimal size for the scintillators at 2×2×5cm3225𝑐superscript𝑚32\times 2\times 5~{}cm^{3}2 × 2 × 5 italic_c italic_m start_POSTSUPERSCRIPT 3 end_POSTSUPERSCRIPT for the transverse polarized case. We need to modify this size for our unpolarized TCS experiment, since the magnetic field is different. The proton identifications will require the dE/dX𝑑𝐸𝑑𝑋{dE}/{dX}italic_d italic_E / italic_d italic_X signal from the hodoscopes. The hodoscopes will also be used for the trigger system (from either the lepton pair solely, or all 3 scattered particles). For this experiment, the general idea of the trigger will follow the already proposed polarized TCS experiments. Details on the polarized case we are refering to are in [7].

2.6 Electromagnetic calorimeters

To determine the kinematic variables Qsuperscript𝑄Q^{\prime}italic_Q start_POSTSUPERSCRIPT ′ end_POSTSUPERSCRIPT, ξ𝜉\xiitalic_ξ, and t𝑡titalic_t, we need to measure the coordinates and the energy of the di-lepton (e+superscript𝑒e^{+}italic_e start_POSTSUPERSCRIPT + end_POSTSUPERSCRIPT, esuperscript𝑒e^{-}italic_e start_POSTSUPERSCRIPT - end_POSTSUPERSCRIPT) pair. We are using a highly segmented lead-tungstate calorimeter. As shown in the Fig 2, each of the four detector quadrants has a calorimeter at the end. We plan to use the existing Neutral Particle Spectrometer (NPS) calorimeter (having enough crystals to prepare 2 of our "quadrants"). Our TCS experiment relies on doubling the surface of the NPS, i.e. the total number of crystals. In the polarized TCS [7] experimental setup, for each quadrant we have 23×23232323\times 2323 × 23 matrix of PbWO4 crystal blocks. Each block has 2.05×2.05cm22.052.05𝑐superscript𝑚22.05\times 2.05~{}cm^{2}2.05 × 2.05 italic_c italic_m start_POSTSUPERSCRIPT 2 end_POSTSUPERSCRIPT geometrical cross-sections.

Refer to caption
Figure 6: Simple one calorimeter plane unpolarized TCS setup for the preliminary studies.

3 Results

At this stage of our studies, we decided to study a simple one plane "calorimetric setup", and check the SBS magnet performances, as shown Fig 6. Here we removed all the detectors that were displayed Fig 2, except for one single plane of calorimeter. The calorimeter plane is placed at the 90deg90degree90~{}\deg90 roman_deg with Z𝑍Zitalic_Z axis (parallel to x-y𝑥-𝑦x\text{-}yitalic_x - italic_y plane), and facing the beam direction. The distance between the center of the target to the face of the calorimeter is 350cmsimilar-toabsent350𝑐𝑚\sim 350~{}cm∼ 350 italic_c italic_m.

Refer to caption
(a) TCS weighted events for the for electrons, projected at the face of the calorimeter in Fig:6. No magnetic field is used in the SBS magnet bore. The black box in the middle shows projected opening of the magnetic bore at the calorimeter face. Same is expected for the positrons. Figures are produced by Vardan Tadevosyan.
Refer to caption
(b) TCS weighted events for the for protons, projected at the face of the calorimeter in Fig:6. No magnetic field is used in the SBS magnet bore. The black box in the middle shows projected opening of the magnetic bore at the calorimeter face. Figures are produced by Vardan Tadevosyan.
Figure 7: Projected electron and the proton events at the face of the calorimeter (no magnetic field) in Fig 6.

Without any magnetic field, the TCS weighted electron and proton events are projected at the face of the calorimeter. It is evident from Fig 6(a) that most of the electrons are well within the magnetic bore (black box), i.e. withing ±50cmplus-or-minus50𝑐𝑚\pm 50~{}cm± 50 italic_c italic_m in x𝑥xitalic_x direction around the center of the calorimeter. So, the chance of SBS iron core blocking the electrons is quite low. As positrons are produced in pair production along with the electrons, we can expect the same positional distributions for the them at the face of the calorimeter.

After applying the magnetic field in the magnet, the electrons and positrons are separated and illuminated the different y𝑦yitalic_y positions on the calorimeter as shown in the Fig 7(a) and Fig 7(b). As expected there is no separation between the two particles in x𝑥xitalic_x direction. Electrons populated the region between column 60 and column 80 of the scintillator segmentation, and the positrons populated the region between column 10 and 35. This clearly shows that our magnetic field simulation is acceptable, and with this setup the electrons and the positrons can be separated in space for particle identification.

As shown in the Fig 6(b), even without the magnetic field the protons are not as concentrated in space as the electrons. In the x𝑥xitalic_x direction the spread of the proton (without the magnetic field) is as big as 400cm400𝑐𝑚-400~{}cm- 400 italic_c italic_m to +400cm400𝑐𝑚+400~{}cm+ 400 italic_c italic_m around the center of the calorimeter plane. Here we didn’t show the spread of the protons with the magnetic field in the magnetic bore.

Refer to caption
(a) TCS weighted events for the for electrons, projected at the face of the calorimeter in Fig:6. 2.4T-m2.4𝑇-𝑚2.4\ T\text{-}~{}m2.4 italic_T - italic_m magnetic field is used in the SBS magnet bore. The black box in the middle shows projected opening of the magnetic bore at the calorimeter face.
Refer to caption
(b) TCS weighted events for the for protons, projected at the face of the calorimeter in Fig:6. 2.4T-m2.4𝑇-𝑚2.4\ T\text{-}~{}m2.4 italic_T - italic_m magnetic field is used in the SBS magnet bore. The black box in the middle shows projected opening of the magnetic bore at the calorimeter face.
Figure 8: Projected electron and the proton events at the face of the calorimeter (with magnetic field) in Fig: 6.

4 Future Work

The work discussed in this paper is still progressing. In the next stage, we aim at getting realistic signal and background rates. We will check if the current opening of the magnetic bore is big enough to detect a sufficient number of protons to conduct our experiment in reasonable amount of time. Furthermore, as we are following the basic detector detector geometry of the polarized TCS experiment, we are working together with the proponents of the "polarized case" to the detector design and calculate the full background (physics + experimental) contributions.

5 Summary

We presented our setup to measure unpolarized and beam polarized (circularly) cross sections for the TCS+BH reactions at Hall C in Jefferson Lab. Our work is still ongoing, but our simulatoions already show that the SBS magnet can be used as a part of the PID process in the di-lepton spectrometer we are proposing. The basic design concept of the experimental setup is very similar to the polarized TCS experiment (already proposed), except the unpolarized target, circularly polarized beam and the SBS magnet added to the setup. We are currently working on optimizing the detectors and the full background simulations. Our goal is to submit a new proposal to the JLab Program Advisor Committee in 2024.

References

  • [1] D. Müller, D. Robaschick, B. Geyer, F.M. Dittes, J. Hořejši, Fortschr. Phys. 42, 101 (1994).
  • [2] X. -D. Ji, Phys. Rev. D 55, 7114 (1997)
  • [3] M. Diehl, Phys. Rep. 388, 41 (2003).
  • [4] M. Guidal, H. Moutarde and M. Vanderhaeghen, Rept. Prog. Phys. 76, 066202 (2013)
  • [5] E. R. Berger, M. Diehl and B. Pire, EPJC 23 (2002) 675-689
  • [6] M. Boër, M. Guidal and M. Vanderhaeghen, Eur. Phys. J. A 51 (2015) no.8, 103
  • [7] Boer, M., Tadevosyan, V., et.al., “Proposal for the PAC 50: Timelike Compton Scattering Off a Transversely Polarized Proton," https://www.jlab.org/exp_prog/proposals/22/C12-18-005.pdf, 2022.
  • [8] D. Day et al., Nucl.Instrum.Meth.A 957 (2020) 163429
  • [9] Tanja Horn et al. 2015 J. Phys.: Conf. Ser. 587 012048
  • [10] Hamilton,G.D., Day,D., Keller, D., Niculescu, G., Wojtsekhowski, B., Zhang, J., “Polarization Observables in Wide-Angle Compton Scattering at large s𝑠sitalic_s, t𝑡titalic_t, and u𝑢uitalic_u," https://www.jlab.org/exp_prog/proposals/17/PR12-17-008.pdf, May 2017.
  • [11] Woods, S., and Hall C users and staffs, “2019 Version: Jefferson Lab Hall C Standard Equipment Manual," https://hallcweb.jlab.org/safety-docs/current/Standard-Equipment-Manual.pdf, 2019.
  • [12] Chudakov, E., Day, D., Degtiarenko, P., Ent, R., Hamilton, D.J., Horn, T., Keller, D., Keppel, C., Niculescu, G., Reid, P., Strakovsky, I., Wojtsekhowski, B., Zhang, J., “Documentation of the Conceptual Design of a Compact Photon Source (CPS)," https://wiki.jlab.org/cuawiki/images/1/1c/CPS_document-rev4.1.pdf.