-
Squeezing for Broadband Multidimensional Variational Measurement
Authors:
Aleksandr A. Movsisian,
Sergey P. Vyatchanin
Abstract:
Broadband multidimensional variational measurement allows to overcome Standard Quantum Limit (SQL) of a classical mechanical force detection, resulting from quantum back action, which perturbs evolution of a mechanical oscillator. In this optomechanic scheme detection of a resonant signal force acting on a linear mechanical oscillator coupled to a system with three optical modes with separation ne…
▽ More
Broadband multidimensional variational measurement allows to overcome Standard Quantum Limit (SQL) of a classical mechanical force detection, resulting from quantum back action, which perturbs evolution of a mechanical oscillator. In this optomechanic scheme detection of a resonant signal force acting on a linear mechanical oscillator coupled to a system with three optical modes with separation nearly equal to the mechanical frequency. The measurement is performed by optical pum** of the central optical mode and measuring the light esca** the two other modes. Detection of optimal quadrature components of the optical modes and post processing result in the back action exclusion in a broad frequency band and surpassing SQL. We show that optical losses inside cavity restrict back action exclusion due to loss noise. We also analyze how two-photon (nondegenerate) and conventional (degenerate) squeezing improve sensitivity with account optical losses, considering mainly internal squeezing.
△ Less
Submitted 6 October, 2023;
originally announced October 2023.
-
Enhanced optomechanical interaction in the unbalanced interferometer
Authors:
Alexandr Karpenko,
Mikhail Korobko,
Sergey P. Vyatchanin
Abstract:
Quantum optomechanical systems enable the study of fundamental questions on quantum nature of massive objects. For that a strong coupling between light and mechanical motion is required, which presents a challenge for massive objects. In particular large interferometric sensors with low frequency oscillators are difficult to bring into quantum regime. Here we propose a modification of the Michelso…
▽ More
Quantum optomechanical systems enable the study of fundamental questions on quantum nature of massive objects. For that a strong coupling between light and mechanical motion is required, which presents a challenge for massive objects. In particular large interferometric sensors with low frequency oscillators are difficult to bring into quantum regime. Here we propose a modification of the Michelson-Sagnac interferometer, which allows to boost the optomechanical coupling strength. This is done by unbalancing the central beam-splitter of the interferometer, allowing to balance two types of optomechanical coupling present in the system: dissipative and dispersive. We analyse two different configurations, when the optomechanical cavity is formed by the mirror for the laser pump field (power-recycling), and by the mirror for the signal field (signal-recycling). We show that the imbalance of the beam splitter allows to dramatically increase the optical cooling of the test mass motion. We also formulate the conditions for observing quantum radiation-pressure noise and ponderomotive squeezing. Our configuration can serve as the basis for more complex modifications of the interferometer that would utilize the enhanced coupling strength. This will allow to efficiently reach quantum state of large test masses, opening the way to studying fundamental aspects of quantum mechanics and experimental search for quantum gravity.
△ Less
Submitted 11 May, 2023;
originally announced May 2023.
-
Broadband Coherent Multidimensional Variational Measurement
Authors:
Sergey P. Vyatchanin,
Albert I. Nazmiev,
Andrey B. Matsko
Abstract:
Standard Quantum Limit (SQL) of a classical mechanical force detection results from quantum back action perturbing evolution of a mechanical system. In this paper we show that usage of a multidimensional optical transducer may enable a broadband quantum back action evading measurement. We study a corresponding technique for measurement of a resonant signal force acting on a linear mechanical oscil…
▽ More
Standard Quantum Limit (SQL) of a classical mechanical force detection results from quantum back action perturbing evolution of a mechanical system. In this paper we show that usage of a multidimensional optical transducer may enable a broadband quantum back action evading measurement. We study a corresponding technique for measurement of a resonant signal force acting on a linear mechanical oscillator coupled to an optical system with three optical modes with separation nearly equal to the mechanical frequency. The measurement is performed by optical pum** of the central optical mode and measuring the light esca** the two other modes. By detecting optimal quadrature components of the optical modes and post-processing the measurement results we are able to exclude the back action in a broad frequency band and characterize the force with sensitivity better than SQL. We discuss how proposed scheme relates to multidimensional system containing quantum-mechanics-free subsystems (QMFS) which can evade the SQL using idea of so called "negative mass".
△ Less
Submitted 7 May, 2022;
originally announced May 2022.
-
Combination of dissipative and dispersive coupling in the cavity optomechanical systems
Authors:
Alexandr Karpenko,
Sergey P. Vyatchanin
Abstract:
An analysis is given for the Fabry-Perot cavity having a combination of dissipative and dispersive optomechanical coupling. It is established that the combined coupling leads to optical rigidity. At the same time, this rigidity appears in systems with the combined coupling on the resonant pump, which is not typical for pure dispersive and dissipative couplings. A proposal is made to use this syste…
▽ More
An analysis is given for the Fabry-Perot cavity having a combination of dissipative and dispersive optomechanical coupling. It is established that the combined coupling leads to optical rigidity. At the same time, this rigidity appears in systems with the combined coupling on the resonant pump, which is not typical for pure dispersive and dissipative couplings. A proposal is made to use this system to detect small signal forces with better sensitivity than SQL. It is also demonstrated that this optomechanical system can create ponderomotive squeezing with controllable parameters over a wider range than ponderomotive squeezing using dispersive coupling.
△ Less
Submitted 24 January, 2022;
originally announced January 2022.
-
Broadband Dichromatic Variational Measurement
Authors:
Sergey P. Vyatchanin,
Albert I. Nazmiev,
Andrey B. Matsko
Abstract:
Standard Quantum Limit (SQL) of a classical mechanical force detection results from quantum back action im**ed by the meter on a probe mechanical transducer perturbed by the force of interest. In this paper we introduce a technique of continuous \vy{broadband} back action avoiding measurements for the case of a resonant signal force acting on a linear mechanical oscillator supporting one of mirr…
▽ More
Standard Quantum Limit (SQL) of a classical mechanical force detection results from quantum back action im**ed by the meter on a probe mechanical transducer perturbed by the force of interest. In this paper we introduce a technique of continuous \vy{broadband} back action avoiding measurements for the case of a resonant signal force acting on a linear mechanical oscillator supporting one of mirrors of an optical Michelson-Sagnac Interferometer (MSI). The interferometer with the movable mirror is an opto-mechanical transducer able to support polychromatic probe field. The method involves a dichromatic optical probe resonant with the MSI modes and having frequency separation equal to the mechanical frequency. We show that analyzing each of the harmonics of the probe reflected from the mechanical system separately and postprocessing the measurement results allows excluding the back action in a broad frequency band and measuring the force with sensitivity better than SQL.
△ Less
Submitted 6 May, 2021;
originally announced May 2021.
-
Broadband Back Action Cancellation in a Dichromatic Variational Measurement
Authors:
Sergey P. Vyatchanin,
Andrey B. Matsko
Abstract:
Quantum back action imposes fundamental sensitivity limits to the majority of quantum measurements. The effect results from the unavoidable contamination of the measured parameter with the quantum noise of a meter. Back action evading measurements take advantage of the quantum correlations introduced by the system under study to the meter and allow overcoming the fundamental limitations. The measu…
▽ More
Quantum back action imposes fundamental sensitivity limits to the majority of quantum measurements. The effect results from the unavoidable contamination of the measured parameter with the quantum noise of a meter. Back action evading measurements take advantage of the quantum correlations introduced by the system under study to the meter and allow overcoming the fundamental limitations. The measurements are frequently restricted in their bandwidth due to a finite response time of the system components. Here we show that probing a mechanical oscillator with a dichromatic field with frequencies separated by the oscillator frequency enables independent detection and complete subtraction of the measurement noise associated with the quantum back action.
△ Less
Submitted 6 May, 2021;
originally announced May 2021.
-
Stable Optical Rigidity Based on Dissipative Coupling
Authors:
Albert Nazmiev,
Sergey P. Vyatchanin
Abstract:
We show that the stable optical rigidity can be obtained in a Fabry-Perot cavity with dissipative optomechanical coupling and with detuned pump, corresponding conditions are formulated. An optical detection of a weak classical mechanical force with usage of this rigidity is analyzed. The sensitivity of small force measurement can be better than the standard quantum limit (SQL).
We show that the stable optical rigidity can be obtained in a Fabry-Perot cavity with dissipative optomechanical coupling and with detuned pump, corresponding conditions are formulated. An optical detection of a weak classical mechanical force with usage of this rigidity is analyzed. The sensitivity of small force measurement can be better than the standard quantum limit (SQL).
△ Less
Submitted 23 September, 2018;
originally announced September 2018.
-
Gyroscope as quantum angular speed meter
Authors:
Andrey B. Matsko,
Sergey P. Vyatchanin
Abstract:
We found that the measurement sensitivity of an optical integrating gyroscope is fundamentally limited due to ponderomotive action of the light leading to the standard quantum limit of the rotation angle detection. The uncorrelated quantum fluctuations of power of clockwise and counterclockwise electromagnetic waves result in optical power-dependent uncertainty of the angular gyroscope position. W…
▽ More
We found that the measurement sensitivity of an optical integrating gyroscope is fundamentally limited due to ponderomotive action of the light leading to the standard quantum limit of the rotation angle detection. The uncorrelated quantum fluctuations of power of clockwise and counterclockwise electromagnetic waves result in optical power-dependent uncertainty of the angular gyroscope position. We also show that, on the other hand, a quantum back action evading measurement of angular momentum of a gyroscope becomes feasible if proper measurement strategy is selected. The angle is perturbed in this case. This observation hints on fundamental inequivalency of integrating and rate gyroscopes.
△ Less
Submitted 19 June, 2018;
originally announced June 2018.
-
Electromagnetic Continuum Induced Nonlinearity
Authors:
Andrey B. Matsko,
Sergey P. Vyatchanin
Abstract:
A nonrelativistic Hamiltonian describing interaction between a mechanical degree of freedom and radiation pressure is commonly used as an ultimate tool for studying system behavior in opto-mechanics. This Hamiltonian is derived from the equation of motion of a mechanical degree of freedom and the optical wave equation with time-varying boundary conditions. We show that this approach is deficient f…
▽ More
A nonrelativistic Hamiltonian describing interaction between a mechanical degree of freedom and radiation pressure is commonly used as an ultimate tool for studying system behavior in opto-mechanics. This Hamiltonian is derived from the equation of motion of a mechanical degree of freedom and the optical wave equation with time-varying boundary conditions. We show that this approach is deficient for studying higher order nonlinear effects in an open resonant opto-mechanical system. Opto-mechanical interaction induces a large mechanical nonlinearity resulting from a strong dependence of the power of the light confined in the optical cavity on the mechanical degrees of freedom of the cavity due to coupling with electromagnetic continuum. This dissipative nonlinearity cannot be inferred from the standard Hamiltonian formalism.
△ Less
Submitted 22 April, 2018;
originally announced April 2018.
-
On sensitivity limitations of a dichromatic optical detection of a classical mechanical force
Authors:
Sergey P. Vyatchanin,
Andrey B. Matsko
Abstract:
We apply the strategy of the back action evading measurement of a quadrature component of mechanical motion of a test mass to detection of a classical force acting on the mass (Science, 209, (1980) 547) and study both classical and quantum limitations of the technique. We are considering a resonant displacement transducer interrogated with a dichromatic optical pump as a model system in this study…
▽ More
We apply the strategy of the back action evading measurement of a quadrature component of mechanical motion of a test mass to detection of a classical force acting on the mass (Science, 209, (1980) 547) and study both classical and quantum limitations of the technique. We are considering a resonant displacement transducer interrogated with a dichromatic optical pump as a model system in this study. The transducer is represented by a Fabry Perot cavity with a totally reflecting movable end mirror the resonant force of interest acts upon. The cavity is pumped with two coherent optical carriers equally detuned from one of the cavity resonances. We show that the quantum back action cannot be completely excluded from the measurement result due to the dynamic instability of the opto-mechanical system that either limits the allowable power of the optical pump or calls for introducing an asymmetry to the pump configuration destroying the quantum nondemolition nature of the measurement.
△ Less
Submitted 21 December, 2017;
originally announced December 2017.
-
Back action cancellation in resolved sideband regime
Authors:
Alena A. Demchenko,
Sergey P. Vyatchanin
Abstract:
We consider the simple model of measurement of mechanical oscillator position via Fabry-Pero cavity pumped by detuned laser (end mirror of cavity is mass of oscillator) in resolved sideband regime when laser is detuned from cavity's frequency by frequency of mechanical oscillator $\pmω_m$ and relaxation rate $γ$ of cavity is small: $γ\ll ω_m$. We demonstrate fluctuation back action cancellation in…
▽ More
We consider the simple model of measurement of mechanical oscillator position via Fabry-Pero cavity pumped by detuned laser (end mirror of cavity is mass of oscillator) in resolved sideband regime when laser is detuned from cavity's frequency by frequency of mechanical oscillator $\pmω_m$ and relaxation rate $γ$ of cavity is small: $γ\ll ω_m$. We demonstrate fluctuation back action cancellation in reflected wave. However, it does not allow to circumvent Standard Quantum Limit, the reason of it is the dynamic back action.
△ Less
Submitted 18 March, 2013;
originally announced March 2013.
-
Squeezing of optomechanical modes in detuned Fabry-Perot interferometer
Authors:
Andrey A. Rakhubovsky,
Sergey P. Vyatchanin
Abstract:
We carry out analysis of optomechanical system formed by moveable mirror of Fabry-Perot cavity pumped by detuned laser. Optical spring arising from detuned pump creates in the system several eigen modes which could be treated as high-Q oscillators. Modulation of laser power results in parametric modulation of oscillators spring constants thus allowing to squeeze noise in quadratures of the modes.…
▽ More
We carry out analysis of optomechanical system formed by moveable mirror of Fabry-Perot cavity pumped by detuned laser. Optical spring arising from detuned pump creates in the system several eigen modes which could be treated as high-Q oscillators. Modulation of laser power results in parametric modulation of oscillators spring constants thus allowing to squeeze noise in quadratures of the modes. Evidence of the squeezing could be found in the light reflected from the cavity.
△ Less
Submitted 14 September, 2013; v1 submitted 12 December, 2012;
originally announced December 2012.
-
Reduction of coating thermal noise by using an etalon
Authors:
Kentaro Somiya,
Daniel Heinert,
Alexey G. Gurkovsky,
Stefan Hild,
Ronny Nawrodt,
Sergey P. Vyatchanin
Abstract:
Reduction of coating thermal noise is a key issue in precise measurements with an optical interferometer. A good example of such a measurement device is a gravitational-wave detector, where each mirror is coated by a few tens of quarter-wavelength dielectric layers to achieve high reflectivity while the thermal-noise level increases with the number of layers. One way to realize the reduction of co…
▽ More
Reduction of coating thermal noise is a key issue in precise measurements with an optical interferometer. A good example of such a measurement device is a gravitational-wave detector, where each mirror is coated by a few tens of quarter-wavelength dielectric layers to achieve high reflectivity while the thermal-noise level increases with the number of layers. One way to realize the reduction of coating thermal noise, recently proposed by Khalili, is the mechanical separation of the first few layers from the rest so that a major part of the fluctuations contributes only little to the phase shift of the reflected light. Using an etalon, a Fabry-Perot optical resonator of a monolithic cavity, with a few coating layers on the front and significantly more on the back surface is a way to realize such a system without too much complexity, and in this paper we perform a thermal-noise analysis of an etalon using the Fluctuation-dissipation theorem with probes on both sides of a finite-size cylindrical mirror.
△ Less
Submitted 28 January, 2011;
originally announced January 2011.
-
The noise in gravitational-wave detectors and other classical-force measurements is not influenced by test-mass quantization
Authors:
Vladimir B. Braginsky,
Mikhail L. Gorodetsky,
Farid Ya. Khalili,
Andrey B. Matsko,
Kip S. Thorne,
Sergey P. Vyatchanin
Abstract:
It is shown that photon shot noise and radiation-pressure back-action noise are the sole forms of quantum noise in interferometric gravitational wave detectors that operate near or below the standard quantum limit, if one filters the interferometer output appropriately. No additional noise arises from the test masses' initial quantum state or from reduction of the test-mass state due to measurem…
▽ More
It is shown that photon shot noise and radiation-pressure back-action noise are the sole forms of quantum noise in interferometric gravitational wave detectors that operate near or below the standard quantum limit, if one filters the interferometer output appropriately. No additional noise arises from the test masses' initial quantum state or from reduction of the test-mass state due to measurement of the interferometer output or from the uncertainty principle associated with the test-mass state. Two features of interferometers are central to these conclusions: (i) The interferometer output (the photon number flux N(t) entering the final photodetector) commutes with itself at different times in the Heisenberg Picture, [N(t), N(t')] = 0, and thus can be regarded as classical. (ii) This number flux is linear in the test-mass initial position and momentum operators x_o and p_o, and those operators influence the measured photon flux N(t) in manners that can easily be removed by filtering -- e.g., in most interferometers, by discarding data near the test masses' 1 Hz swinging freqency. The test-mass operators x_o and p_o contained in the unfiltered output N(t) make a nonzero contribution to the commutator [N(t), N(t')]. That contribution is cancelled by a nonzero commutation of the photon shot noise and radiation-pressure noise, which also are contained in N(t). This cancellation of commutators is responsible for the fact that it is possible to derive an interferometer's standard quantum limit from test-mass considerations, and independently from photon-noise considerations. These conclusions are true for a far wider class of measurements than just gravitational-wave interferometers. To elucidate them, this paper presents a series of idealized thought experiments that are free from the complexities of real measuring systems.
△ Less
Submitted 1 December, 2002; v1 submitted 2 September, 2001;
originally announced September 2001.
-
Conversion of conventional gravitational-wave interferometers into QND interferometers by modifying their input and/or output optics
Authors:
H. J. Kimble,
Yuri Levin,
Andrey B. Matsko,
Kip S. Thorne,
Sergey P. Vyatchanin
Abstract:
The LIGO-II gravitational-wave interferometers (ca. 2006--2008) are designed to have sensitivities at about the standard quantum limit (SQL) near 100 Hz. This paper describes and analyzes possible designs for subsequent, LIGO-III interferometers that can beat the SQL. These designs are identical to a conventional broad-band interferometer (without signal recycling), except for new input and/or o…
▽ More
The LIGO-II gravitational-wave interferometers (ca. 2006--2008) are designed to have sensitivities at about the standard quantum limit (SQL) near 100 Hz. This paper describes and analyzes possible designs for subsequent, LIGO-III interferometers that can beat the SQL. These designs are identical to a conventional broad-band interferometer (without signal recycling), except for new input and/or output optics. Three designs are analyzed: (i) a "squeezed-input interferometer" (conceived by Unruh based on earlier work of Caves) in which squeezed vacuum with frequency-dependent (FD) squeeze angle is injected into the interferometer's dark port; (ii) a "variational-output" interferometer (conceived in a different form by Vyatchanin, Matsko and Zubova), in which homodyne detection with FD homodyne phase is performed on the output light; and (iii) a "squeezed-variational interferometer" with squeezed input and FD-homodyne output. It is shown that the FD squeezed-input light can be produced by sending ordinary squeezed light through two successive Fabry-Perot filter cavities before injection into the interferometer, and FD-homodyne detection can be achieved by sending the output light through two filter cavities before ordinary homodyne detection. With anticipated technology and with laser powers comparable to that planned for LIGO-II, these interferometers can beat the amplitude SQL by factors in the range from 3 to 5, corresponding to event rate increases between ~30 and ~100 over the rate for a SQL-limited interferometer.
△ Less
Submitted 3 September, 2001; v1 submitted 11 August, 2000;
originally announced August 2000.