-
Verifying Multipartite Entangled GHZ States via Multiple Quantum Coherences
Authors:
Ken X. Wei,
Isaac Lauer,
Srikanth Srinivasan,
Neereja Sundaresan,
Douglas T. McClure,
David Toyli,
David C. McKay,
Jay M. Gambetta,
Sarah Sheldon
Abstract:
The ability to generate and verify multipartite entanglement is an important benchmark for near-term quantum devices devices. We develop a scalable entanglement metric based on multiple quantum coherences, and demonstrate experimentally on a 20-qubit superconducting device - the IBM Q System One. We report a state fidelity of 0.5165$\pm$0.0036 for an 18-qubit GHZ state, indicating multipartite ent…
▽ More
The ability to generate and verify multipartite entanglement is an important benchmark for near-term quantum devices devices. We develop a scalable entanglement metric based on multiple quantum coherences, and demonstrate experimentally on a 20-qubit superconducting device - the IBM Q System One. We report a state fidelity of 0.5165$\pm$0.0036 for an 18-qubit GHZ state, indicating multipartite entanglement across all 18 qubits. Our entanglement metric is robust to noise and only requires measuring the population in the ground state; it can be readily applied to other quantum devices to verify multipartite entanglement.
△ Less
Submitted 14 May, 2019;
originally announced May 2019.
-
High-efficiency measurement of an artificial atom embedded in a parametric amplifier
Authors:
A. Eddins,
J. M. Kreikebaum,
D. M. Toyli,
E. M. Levenson-Falk,
A. Dove,
W. P. Livingston,
B. A. Levitan,
L. C. G. Govia,
A. A. Clerk,
I. Siddiqi
Abstract:
A crucial limit to measurement efficiencies of superconducting circuits comes from losses involved when coupling to an external quantum amplifier. Here, we realize a device circumventing this problem by directly embedding a two-level artificial atom, comprised of a transmon qubit, within a flux-pumped Josephson parametric amplifier. Surprisingly, this configuration is able to enhance dispersive me…
▽ More
A crucial limit to measurement efficiencies of superconducting circuits comes from losses involved when coupling to an external quantum amplifier. Here, we realize a device circumventing this problem by directly embedding a two-level artificial atom, comprised of a transmon qubit, within a flux-pumped Josephson parametric amplifier. Surprisingly, this configuration is able to enhance dispersive measurement without exposing the qubit to appreciable excess backaction. This is accomplished by engineering the circuit to permit high-power operation that reduces information loss to unmonitored channels associated with the amplification and squeezing of quantum noise. By mitigating the effects of off-chip losses downstream, the on-chip gain of this device produces end-to-end measurement efficiencies of up to 80 percent. Our theoretical model accurately describes the observed interplay of gain and measurement backaction, and delineates the parameter space for future improvement. The device is compatible with standard fabrication and measurement techniques, and thus provides a route for definitive investigations of fundamental quantum effects and quantum control protocols.
△ Less
Submitted 13 June, 2018;
originally announced June 2018.
-
Stroboscopic qubit measurement with squeezed illumination
Authors:
Andrew Eddins,
Sydney Schreppler,
David M. Toyli,
Leigh S. Martin,
Shay Hacohen-Gourgy,
Luke C. G. Govia,
Hugo Ribeiro,
Aashish A. Clerk,
Irfan Siddiqi
Abstract:
Microwave squeezing represents the ultimate sensitivity frontier for superconducting qubit measurement. However, observation of enhancement has remained elusive, in part because integration with conventional dispersive readout pollutes the signal channel with antisqueezed vacuum. Here we induce a stroboscopic light-matter coupling with superior squeezing compatibility, and observe an increase in t…
▽ More
Microwave squeezing represents the ultimate sensitivity frontier for superconducting qubit measurement. However, observation of enhancement has remained elusive, in part because integration with conventional dispersive readout pollutes the signal channel with antisqueezed vacuum. Here we induce a stroboscopic light-matter coupling with superior squeezing compatibility, and observe an increase in the room-temperature signal-to-noise ratio of 24%. Squeezing the orthogonal phase controls measurement backaction, slowing dephasing by a factor of 1.8. This protocol enables the practical use of microwave squeezing for qubit state measurement.
△ Less
Submitted 4 August, 2017;
originally announced August 2017.
-
Effect of higher-order nonlinearities on amplification and squeezing in Josephson parametric amplifiers
Authors:
Samuel Boutin,
David M. Toyli,
Aditya V. Venkatramani,
Andrew W. Eddins,
Irfan Siddiqi,
Alexandre Blais
Abstract:
Single-mode Josephson junction-based parametric amplifiers are often modeled as perfect amplifiers and squeezers. We show that, in practice, the gain, quantum efficiency, and output field squeezing of these devices are limited by usually neglected higher-order corrections to the idealized model. To arrive at this result, we derive the leading corrections to the lumped-element Josephson parametric…
▽ More
Single-mode Josephson junction-based parametric amplifiers are often modeled as perfect amplifiers and squeezers. We show that, in practice, the gain, quantum efficiency, and output field squeezing of these devices are limited by usually neglected higher-order corrections to the idealized model. To arrive at this result, we derive the leading corrections to the lumped-element Josephson parametric amplifier of three common pum** schemes: monochromatic current pump, bichromatic current pump, and monochromatic flux pump. We show that the leading correction for the last two schemes is a single Kerr-type quartic term, while the first scheme contains additional cubic terms. In all cases, we find that the corrections are detrimental to squeezing. In addition, we show that the Kerr correction leads to a strongly phase-dependent reduction of the quantum efficiency of a phase-sensitive measurement. Finally, we quantify the departure from ideal Gaussian character of the filtered output field from numerical calculation of third and fourth order cumulants. Our results show that, while a Gaussian output field is expected for an ideal Josephson parametric amplifier, higher-order corrections lead to non-Gaussian effects which increase with both gain and nonlinearity strength. This theoretical study is complemented by experimental characterization of the output field of a flux-driven Josephson parametric amplifier. In addition to a measurement of the squeezing level of the filtered output field, the Husimi Q-function of the output field is imaged by the use of a deconvolution technique and compared to numerical results. This work establishes nonlinear corrections to the standard degenerate parametric amplifier model as an important contribution to Josephson parametric amplifier's squeezing and noise performance.
△ Less
Submitted 17 November, 2017; v1 submitted 31 July, 2017;
originally announced August 2017.
-
Resonance fluorescence from an artificial atom in squeezed vacuum
Authors:
D. M. Toyli,
A. W. Eddins,
S. Boutin,
S. Puri,
D. Hover,
V. Bolkhovsky,
W. D. Oliver,
A. Blais,
I. Siddiqi
Abstract:
We present an experimental realization of resonance fluorescence in squeezed vacuum. We strongly couple microwave-frequency squeezed light to a superconducting artificial atom and detect the resulting fluorescence with high resolution enabled by a broadband traveling-wave parametric amplifier. We investigate the fluorescence spectra in the weak and strong driving regimes, observing up to 3.1 dB of…
▽ More
We present an experimental realization of resonance fluorescence in squeezed vacuum. We strongly couple microwave-frequency squeezed light to a superconducting artificial atom and detect the resulting fluorescence with high resolution enabled by a broadband traveling-wave parametric amplifier. We investigate the fluorescence spectra in the weak and strong driving regimes, observing up to 3.1 dB of reduction of the fluorescence linewidth below the ordinary vacuum level and a dramatic dependence of the Mollow triplet spectrum on the relative phase of the driving and squeezed vacuum fields. Our results are in excellent agreement with predictions for spectra produced by a two-level atom in squeezed vacuum [Phys. Rev. Lett. \textbf{58}, 2539-2542 (1987)], demonstrating that resonance fluorescence offers a resource-efficient means to characterize squeezing in cryogenic environments.
△ Less
Submitted 15 July, 2016; v1 submitted 9 February, 2016;
originally announced February 2016.
-
Fluorescence thermometry enhanced by the quantum coherence of single spins in diamond
Authors:
David M. Toyli,
Charles F. de las Casas,
David J. Christle,
Viatcheslav V. Dobrovitski,
David D. Awschalom
Abstract:
We demonstrate fluorescence thermometry techniques with sensitivities approaching 10 mK Hz^(-1/2) based on the spin-dependent photoluminescence of nitrogen vacancy (NV) centers in diamond. These techniques use dynamical decoupling protocols to convert thermally induced shifts in the NV center's spin resonance frequencies into large changes in its fluorescence. By mitigating interactions with nearb…
▽ More
We demonstrate fluorescence thermometry techniques with sensitivities approaching 10 mK Hz^(-1/2) based on the spin-dependent photoluminescence of nitrogen vacancy (NV) centers in diamond. These techniques use dynamical decoupling protocols to convert thermally induced shifts in the NV center's spin resonance frequencies into large changes in its fluorescence. By mitigating interactions with nearby nuclear spins and facilitating selective thermal measurements, these protocols enhance the spin coherence times accessible for thermometry by 45x, corresponding to a 7x improvement in the NV center's temperature sensitivity. Moreover, we demonstrate these techniques can be applied over a broad temperature range and in both finite and near-zero magnetic field environments. This versatility suggests that the quantum coherence of single spins could be practically leveraged for sensitive thermometry in a wide variety of biological and microscale systems.
△ Less
Submitted 8 May, 2013; v1 submitted 26 March, 2013;
originally announced March 2013.
-
Engineering shallow spins in diamond with nitrogen delta-do**
Authors:
Kenichi Ohno,
F. Joseph Heremans,
Lee C. Bassett,
Bryan A. Myers,
David M. Toyli,
Ania C. Bleszynski Jayich,
Christopher J. Palmstrom,
David D. Awschalom
Abstract:
We demonstrate nanometer-precision depth control of nitrogen-vacancy (NV) center creation near the surface of synthetic diamond using an in situ nitrogen delta-do** technique during plasma-enhanced chemical vapor deposition. Despite their proximity to the surface, doped NV centers with depths (d) ranging from 5 - 100 nm display long spin coherence times, T2 > 100 \mus at d = 5 nm and T2 > 600 \m…
▽ More
We demonstrate nanometer-precision depth control of nitrogen-vacancy (NV) center creation near the surface of synthetic diamond using an in situ nitrogen delta-do** technique during plasma-enhanced chemical vapor deposition. Despite their proximity to the surface, doped NV centers with depths (d) ranging from 5 - 100 nm display long spin coherence times, T2 > 100 \mus at d = 5 nm and T2 > 600 \mus at d \geq 50 nm. The consistently long spin coherence observed in such shallow NV centers enables applications such as atomic-scale external spin sensing and hybrid quantum architectures.
△ Less
Submitted 11 July, 2012;
originally announced July 2012.
-
Decoherence-protected quantum gates for a hybrid solid-state spin register
Authors:
T. van der Sar,
Z. H. Wang,
M. S. Blok,
H. Bernien,
T. H. Taminiau,
D. M. Toyli,
D. A. Lidar,
D. D. Awschalom,
R. Hanson,
V. V. Dobrovitski
Abstract:
Protecting the dynamics of coupled quantum systems from decoherence by the environment is a key challenge for solid-state quantum information processing. An idle qubit can be efficiently insulated from the outside world via dynamical decoupling, as has recently been demonstrated for individual solid-state qubits. However, protection of qubit coherence during a multi-qubit gate poses a non-trivial…
▽ More
Protecting the dynamics of coupled quantum systems from decoherence by the environment is a key challenge for solid-state quantum information processing. An idle qubit can be efficiently insulated from the outside world via dynamical decoupling, as has recently been demonstrated for individual solid-state qubits. However, protection of qubit coherence during a multi-qubit gate poses a non-trivial problem: in general the decoupling disrupts the inter-qubit dynamics, and hence conflicts with gate operation. This problem is particularly salient for hybrid systems, wherein different types of qubits evolve and decohere at vastly different rates. Here we present the integration of dynamical decoupling into quantum gates for a paradigmatic hybrid system, the electron-nuclear spin register. Our design harnesses the internal resonance in the coupled-spin system to resolve the conflict between gate operation and decoupling. We experimentally demonstrate these gates on a two-qubit register in diamond operating at room temperature. Quantum tomography reveals that the qubits involved in the gate operation are protected as accurately as idle qubits. We further illustrate the power of our design by executing Grover's quantum search algorithm, achieving fidelities above 90% even though the execution time exceeds the electron spin dephasing time by two orders of magnitude. Our results directly enable decoherence-protected interface gates between different types of promising solid-state qubits. Ultimately, quantum gates with integrated decoupling may enable reaching the accuracy threshold for fault-tolerant quantum information processing with solid-state devices.
△ Less
Submitted 20 February, 2012;
originally announced February 2012.
-
Measurement and Control of Single Nitrogen-Vacancy Center Spins above 600 K
Authors:
D. M. Toyli,
D. J. Christle,
A. Alkauskas,
B. B. Buckley,
C. G. Van de Walle,
D. D. Awschalom
Abstract:
We study the spin and orbital dynamics of single nitrogen-vacancy (NV) centers in diamond between room temperature and 700 K. We find that the ability to optically address and coherently control single spins above room temperature is limited by nonradiative processes that quench the NV center's fluorescence-based spin readout between 550 and 700 K. Combined with electronic structure calculations,…
▽ More
We study the spin and orbital dynamics of single nitrogen-vacancy (NV) centers in diamond between room temperature and 700 K. We find that the ability to optically address and coherently control single spins above room temperature is limited by nonradiative processes that quench the NV center's fluorescence-based spin readout between 550 and 700 K. Combined with electronic structure calculations, our measurements indicate that the energy difference between the 3E and 1A1 electronic states is approximately 0.8 eV. We also demonstrate that the inhomogeneous spin lifetime (T2*) is temperature independent up to at least 625 K, suggesting that single NV centers could be applied as nanoscale thermometers over a broad temperature range.
△ Less
Submitted 16 July, 2012; v1 submitted 20 January, 2012;
originally announced January 2012.
-
Chip-scale nanofabrication of single spins and spin arrays in diamond
Authors:
David M. Toyli,
Christoph D. Weis,
Gregory D. Fuchs,
Thomas Schenkel,
David D. Awschalom
Abstract:
We demonstrate a technique to nanofabricate nitrogen vacancy (NV) centers in diamond based on broad-beam nitrogen implantation through apertures in electron beam lithography resist. This method enables high-throughput nanofabrication of single NV centers on sub-100 nm length scales. Secondary ion mass spectroscopy (SIMS) measurements facilitate depth profiling of the implanted nitrogen to provide…
▽ More
We demonstrate a technique to nanofabricate nitrogen vacancy (NV) centers in diamond based on broad-beam nitrogen implantation through apertures in electron beam lithography resist. This method enables high-throughput nanofabrication of single NV centers on sub-100 nm length scales. Secondary ion mass spectroscopy (SIMS) measurements facilitate depth profiling of the implanted nitrogen to provide three-dimensional characterization of the NV center spatial distribution. Measurements of NV center coherence with on-chip coplanar waveguides suggest a pathway for incorporating this scalable nanofabrication technique in future quantum applications.
△ Less
Submitted 2 July, 2010; v1 submitted 1 July, 2010;
originally announced July 2010.