Dynamic stabilization of the optical resonances of single nitrogen-vacancy centers in diamond
Authors:
V. M. Acosta,
C. Santori,
A. Faraon,
Z. Huang,
K. -M. C. Fu,
A. Stacey,
D. A. Simpson,
S. Tomljenovic-Hanic,
K. Ganesan,
A. D. Greentree,
S. Prawer,
R. G. Beausoleil
Abstract:
We report electrical tuning by the Stark effect of the excited-state structure of single nitrogen-vacancy (NV) centers located less than ~100 nm from the diamond surface. The zero-phonon line (ZPL) emission frequency is controllably varied over a range of 300 GHz. Using high-resolution emission spectroscopy, we observe electrical tuning of the strengths of both cycling and spin-altering transition…
▽ More
We report electrical tuning by the Stark effect of the excited-state structure of single nitrogen-vacancy (NV) centers located less than ~100 nm from the diamond surface. The zero-phonon line (ZPL) emission frequency is controllably varied over a range of 300 GHz. Using high-resolution emission spectroscopy, we observe electrical tuning of the strengths of both cycling and spin-altering transitions. Under resonant excitation, we apply dynamic feedback to stabilize the ZPL frequency. The transition is locked over several minutes and drifts of the peak position on timescales greater than ~100 ms are reduced to a fraction of the single-scan linewidth, with standard deviation as low as 16 MHz (obtained for an NV in bulk, ultra-pure diamond). These techniques should improve the entanglement success probability in quantum communications protocols.
△ Less
Submitted 3 April, 2012; v1 submitted 22 December, 2011;
originally announced December 2011.
-
Low-temperature tapered-fiber probing of diamond NV ensembles coupled to GaP microcavities
Authors:
K. -M. C. Fu,
P. E. Barclay,
C. Santori,
A. Faraon,
R. G. Beausoleil
Abstract:
In this work we present a platform for testing the device performance of a cavity-emitter system, using an ensemble of emitters and a tapered optical fiber. This method provides high-contrast spectra of the cavity modes, selective detection of emitters coupled to the cavity, and an estimate of the device performance in the single- emitter case. Using nitrogen-vacancy (NV) centers in diamond and a…
▽ More
In this work we present a platform for testing the device performance of a cavity-emitter system, using an ensemble of emitters and a tapered optical fiber. This method provides high-contrast spectra of the cavity modes, selective detection of emitters coupled to the cavity, and an estimate of the device performance in the single- emitter case. Using nitrogen-vacancy (NV) centers in diamond and a GaP optical microcavity, we are able to tune the cavity onto the NV resonance at 10 K, couple the cavity-coupled emission to a tapered fiber, and measure the fiber-coupled NV spontaneous emission decay. Theoretically we show that the fiber-coupled average Purcell factor is 2-3 times greater than that of free-space collection; although due to ensemble averaging it is still a factor of 3 less than the Purcell factor of a single, ideally placed center.
△ Less
Submitted 25 February, 2011;
originally announced February 2011.
-
High nitrogen-vacancy density diamonds for magnetometry applications
Authors:
V. M. Acosta,
E. Bauch,
M. P. Ledbetter,
C. Santori,
K. -M. C. Fu,
P. E. Barclay,
R. G. Beausoleil,
H. Linget,
J. F. Roch,
F. Treussart,
S. Chemerisov,
W. Gawlik,
D. Budker
Abstract:
Nitrogen-vacancy (NV) centers in millimeter-scale diamond samples were produced by irradiation and subsequent annealing under varied conditions. The optical and spin relaxation properties of these samples were characterized using confocal microscopy, visible and infrared absorption, and optically detected magnetic resonance. The sample with the highest NV- concentration, approximately 16 ppm = 2…
▽ More
Nitrogen-vacancy (NV) centers in millimeter-scale diamond samples were produced by irradiation and subsequent annealing under varied conditions. The optical and spin relaxation properties of these samples were characterized using confocal microscopy, visible and infrared absorption, and optically detected magnetic resonance. The sample with the highest NV- concentration, approximately 16 ppm = 2.8 x 10^{18} cm^{-3}, was prepared with no observable traces of neutrally-charged vacancy defects. The effective transverse spin relaxation time for this sample was T2* = 118(48) ns, predominately limited by residual paramagnetic nitrogen which was determined to have a concentration of 52(7) ppm. Under ideal conditions, the shot-noise limited sensitivity is projected to be ~150 fT/\sqrt{Hz} for a 100 micron-scale magnetometer based on this sample. Other samples with NV- concentrations from .007 to 12 ppm and effective relaxation times ranging from 27 to 291 ns were prepared and characterized.
△ Less
Submitted 31 July, 2009; v1 submitted 19 March, 2009;
originally announced March 2009.
-
Coupling of nitrogen-vacancy centers in diamond to a GaP waveguide
Authors:
K. -M. C. Fu,
C. Santori,
P. E. Barclay,
I. Aharonovich,
S. Prawer,
N. Meyer,
A. M. Holm,
R. G. Beausoleil
Abstract:
The optical coupling of guided modes in a GaP waveguide to nitrogen-vacancy (NV) centers in diamond is demonstrated. The electric field penetration into diamond and the loss of the guided mode are measured. The results indicate that the GaP-diamond system could be useful for realizing coupled microcavity-NV devices for quantum information processing in diamond.
The optical coupling of guided modes in a GaP waveguide to nitrogen-vacancy (NV) centers in diamond is demonstrated. The electric field penetration into diamond and the loss of the guided mode are measured. The results indicate that the GaP-diamond system could be useful for realizing coupled microcavity-NV devices for quantum information processing in diamond.
△ Less
Submitted 3 November, 2008;
originally announced November 2008.