-
Ensemble inversion for brain tumor growth models with mass effect
Authors:
Shashank Subramanian,
Klaudius Scheufele,
Naveen Himthani,
Christos Davatzikos,
George Biros
Abstract:
We propose a method for extracting physics-based biomarkers from a single multiparametric Magnetic Resonance Imaging (mpMRI) scan bearing a glioma tumor. We account for mass effect, the deformation of brain parenchyma due to the growing tumor, which on its own is an important radiographic feature but its automatic quantification remains an open problem. In particular, we calibrate a partial differ…
▽ More
We propose a method for extracting physics-based biomarkers from a single multiparametric Magnetic Resonance Imaging (mpMRI) scan bearing a glioma tumor. We account for mass effect, the deformation of brain parenchyma due to the growing tumor, which on its own is an important radiographic feature but its automatic quantification remains an open problem. In particular, we calibrate a partial differential equation (PDE) tumor growth model that captures mass effect, parameterized by a single scalar parameter, tumor proliferation, migration, while localizing the tumor initiation site. The single-scan calibration problem is severely ill-posed because the precancerous, healthy, brain anatomy is unknown. To address the ill-posedness, we introduce an ensemble inversion scheme that uses a number of normal subject brain templates as proxies for the healthy precancer subject anatomy. We verify our solver on a synthetic dataset and perform a retrospective analysis on a clinical dataset of 216 glioblastoma (GBM) patients. We analyze the reconstructions using our calibrated biophysical model and demonstrate that our solver provides both global and local quantitative measures of tumor biophysics and mass effect. We further highlight the improved performance in model calibration through the inclusion of mass effect in tumor growth models -- including mass effect in the model leads to 10% increase in average dice coefficients for patients with significant mass effect. We further evaluate our model by introducing novel biophysics-based features and using them for survival analysis. Our preliminary analysis suggests that including such features can improve patient stratification and survival prediction.
△ Less
Submitted 10 June, 2021;
originally announced June 2021.
-
Calibration of Biophysical Models for tau-Protein Spreading in Alzheimer's Disease from PET-MRI
Authors:
Klaudius Scheufele,
Shashank Subramanian,
George Biros
Abstract:
Aggregates of misfolded tau proteins (or just 'tau' for brevity) play a crucial role in the progression of Alzheimer's disease (AD) as they correlate with cell death and accelerated tissue atrophy. Longitudinal positron emission tomography (PET) scans can be used quantify the extend of abnormal tau spread. Such PET-based image biomarkers are a promising technology for AD diagnosis and prognosis. H…
▽ More
Aggregates of misfolded tau proteins (or just 'tau' for brevity) play a crucial role in the progression of Alzheimer's disease (AD) as they correlate with cell death and accelerated tissue atrophy. Longitudinal positron emission tomography (PET) scans can be used quantify the extend of abnormal tau spread. Such PET-based image biomarkers are a promising technology for AD diagnosis and prognosis. Here, we propose to calibrate an organ-scale biophysical mathematical model using longitudinal PET scans to extract characteristic growth patterns and spreading of tau. The biophysical model is a reaction-advection-diffusion partial differential equation (PDE) with only two scalar unknown parameters, one representing the spreading (the diffusion part of the PDE) and the other one the growth of tau (the reaction part of the PDE). The advection term captures tissue atrophy and is obtained from diffeomorphic registration of longitudinal magnetic resonance imaging (MRI) scans. We describe the method, present a numerical scheme for the calibration of the growth and spreading parameters, perform a sensitivity study using synthetic data, and we perform a preliminary evaluation on clinical scans from the ADNI dataset. We study whether such model calibration is possible and investigate the sensitivity of such calibration to the time between consecutive scans and the presence of atrophy. Our findings show that despite using only two calibration parameters, the model can reconstruct clinical scans quite accurately. We discovered that small time intervals between scans and the presence of background noise create difficulties. Our reconstructed model fits the data well, yet the study on clinical data also reveals shortcomings of the simplistic model. Interestingly, the parameters show significant variability across patients, an indication that these parameters could be useful biomarkers.
△ Less
Submitted 5 December, 2020; v1 submitted 2 July, 2020;
originally announced July 2020.
-
Multiatlas Calibration of Biophysical Brain Tumor Growth Models with Mass Effect
Authors:
Shashank Subramanian,
Klaudius Scheufele,
Naveen Himthani,
George Biros
Abstract:
We present a 3D fully-automatic method for the calibration of partial differential equation (PDE) models of glioblastoma (GBM) growth with mass effect, the deformation of brain tissue due to the tumor. We quantify the mass effect, tumor proliferation, tumor migration, and the localized tumor initial condition from a single multiparameteric Magnetic Resonance Imaging (mpMRI) patient scan. The PDE i…
▽ More
We present a 3D fully-automatic method for the calibration of partial differential equation (PDE) models of glioblastoma (GBM) growth with mass effect, the deformation of brain tissue due to the tumor. We quantify the mass effect, tumor proliferation, tumor migration, and the localized tumor initial condition from a single multiparameteric Magnetic Resonance Imaging (mpMRI) patient scan. The PDE is a reaction-advection-diffusion partial differential equation coupled with linear elasticity equations to capture mass effect. The single-scan calibration model is notoriously difficult because the precancerous (healthy) brain anatomy is unknown. To solve this inherently ill-posed and ill-conditioned optimization problem, we introduce a novel inversion scheme that uses multiple brain atlases as proxies for the healthy precancer patient brain resulting in robust and reliable parameter estimation. We apply our method on both synthetic and clinical datasets representative of the heterogeneous spatial landscape typically observed in glioblastomas to demonstrate the validity and performance of our methods. In the synthetic data, we report calibration errors (due to the ill-posedness and our solution scheme) in the 10\%-20\% range. In the clinical data, we report good quantitative agreement with the observed tumor and qualitative agreement with the mass effect (for which we do not have a ground truth). Our method uses a minimal set of parameters and provides both global and local quantitative measures of tumor infiltration and mass effect.
△ Less
Submitted 17 June, 2020;
originally announced June 2020.
-
Automatic MRI-Driven Model Calibration for Advanced Brain Tumor Progression Analysis
Authors:
Klaudius Scheufele,
Shashank Subramanian,
George Biros
Abstract:
Our objective is the calibration of mathematical tumor growth models from a single multiparametric scan. The target problem is the analysis of preoperative Glioblastoma (GBM) scans. To this end, we present a fully automatic tumor-growth calibration methodology that integrates a single-species reaction-diffusion partial differential equation (PDE) model for tumor progression with multiparametric Ma…
▽ More
Our objective is the calibration of mathematical tumor growth models from a single multiparametric scan. The target problem is the analysis of preoperative Glioblastoma (GBM) scans. To this end, we present a fully automatic tumor-growth calibration methodology that integrates a single-species reaction-diffusion partial differential equation (PDE) model for tumor progression with multiparametric Magnetic Resonance Imaging (mpMRI) scans to robustly extract patient specific biomarkers i.e., estimates for (i) the tumor cell proliferation rate, (ii) the tumor cell migration rate, and (iii) the original, localized site(s) of tumor initiation. Our method is based on a sparse reconstruction algorithm for the tumor initial location (TIL). This problem is particularly challenging due to nonlinearity, ill-posedeness, and ill conditioning. We propose a coarse-to-fine multi-resolution continuation scheme with parameter decomposition to stabilize the inversion. We demonstrate robustness and practicality of our method by applying the proposed method to clinical data of 206 GBM patients. We analyze the extracted biomarkers and relate tumor origin with patient overall survival by map** the former into a common atlas space. We present preliminary results that suggest improved accuracy for prediction of patient overall survival when a set of imaging features is augmented with estimated biophysical parameters. All extracted features, tumor initial positions, and biophysical growth parameters are made publicly available for further analysis. To our knowledge, this is the first fully automatic scheme that can handle multifocal tumors and can localize the TIL to a few millimeters.
△ Less
Submitted 24 January, 2020;
originally announced January 2020.
-
Image-Driven Biophysical Tumor Growth Model Calibration
Authors:
Klaudius Scheufele,
Shashank Subramanian,
Andreas Mang,
George Biros,
Miriam Mehl
Abstract:
We present a novel formulation for the calibration of a biophysical tumor growth model from a single-time snapshot, MRI scan of a glioblastoma patient. Tumor growth models are typically nonlinear parabolic partial differential equations (PDEs). Thus, we have to generate a second snapshot to be able to extract significant information from a single patient snapshot. We create this two-snapshot scena…
▽ More
We present a novel formulation for the calibration of a biophysical tumor growth model from a single-time snapshot, MRI scan of a glioblastoma patient. Tumor growth models are typically nonlinear parabolic partial differential equations (PDEs). Thus, we have to generate a second snapshot to be able to extract significant information from a single patient snapshot. We create this two-snapshot scenario as follows. We use an atlas (an average of several scans of healthy individuals) as a substitute for an earlier, pretumor, MRI scan of the patient. Then, using the patient scan and the atlas, we combine image-registration algorithms and parameter estimation algorithms to achieve a better estimate of the healthy patient scan and the tumor growth parameters that are consistent with the data. Our scheme is based on our recent work (Scheufele et al, "Biophysically constrained diffeomorphic image registration, Tumor growth, Atlas registration, Adjoint-based methods, Parallel algorithms", CMAME, 2018), but apply a different and novel scheme where the tumor growth simulation in contrast to the previous work is executed in the patient brain domain and not in the atlas domain yielding more meaningful patient-specific results. As a basis, we use a PDE-constrained optimization framework. We derive a modified Picard-iteration-type solution strategy in which we alternate between registration and tumor parameter estimation in a new way. In addition, we consider an $\ell_1$ sparsity constraint on the initial condition for the tumor and integrate it with the new joint inversion scheme. We solve the subproblems with a reduced-space, inexact Gauss-Newton-Krylov/quasi-Newton methods. We present results using real brain data with synthetic tumor data that show that the new scheme reconstructs the tumor parameters in a more accurate and reliable way compared to our earlier scheme.
△ Less
Submitted 16 July, 2019;
originally announced July 2019.
-
Where did the tumor start? An inverse solver with sparse localization for tumor growth models
Authors:
Shashank Subramanian,
Klaudius Scheufele,
Miriam Mehl,
George Biros
Abstract:
We present a numerical scheme for solving an inverse problem for parameter estimation in tumor growth models for glioblastomas, a form of aggressive primary brain tumor. The growth model is a reaction-diffusion partial differential equation (PDE) for the tumor concentration. We use a PDE-constrained optimization formulation for the inverse problem. The unknown parameters are the reaction coefficie…
▽ More
We present a numerical scheme for solving an inverse problem for parameter estimation in tumor growth models for glioblastomas, a form of aggressive primary brain tumor. The growth model is a reaction-diffusion partial differential equation (PDE) for the tumor concentration. We use a PDE-constrained optimization formulation for the inverse problem. The unknown parameters are the reaction coefficient (proliferation), the diffusion coefficient (infiltration), and the initial condition field for the tumor PDE. Segmentation of Magnetic Resonance Imaging (MRI) scans from a single time snapshot drive the inverse problem where segmented tumor regions serve as partial observations of the tumor concentration. The precise time relative to tumor initiation is unknown, which poses an additional difficulty for inversion. We perform a frozen-coefficient spectral analysis and show that the inverse problem is severely ill-posed. We introduce a biophysically motivated regularization on the tumor initial condition. In particular, we assume that the tumor starts at a few locations (enforced with a sparsity constraint) and that the initial condition magnitude in the maximum norm equals one. We solve the resulting optimization problem using an inexact quasi-Newton method combined with a compressive sampling algorithm for the sparsity constraint. Our implementation uses PETSc and AccFFT libraries. We conduct numerical experiments on synthetic and clinical images to highlight the improved performance of our solver over an existing solver that uses a two-norm regularization for the calibration parameters. The existing solver is unable to localize the initial condition. Our new solver can localize the initial condition and recover infiltration and proliferation. In clinical datasets (for which the ground truth is unknown), our solver results in qualitatively different solutions compared to the existing solver.
△ Less
Submitted 15 July, 2019;
originally announced July 2019.
-
Coupling Brain-Tumor Biophysical Models and Diffeomorphic Image Registration
Authors:
Klaudius Scheufele,
Andreas Mang,
Amir Gholami,
Christos Davatzikos,
George Biros,
Miriam Mehl
Abstract:
We present the SIBIA (Scalable Integrated Biophysics-based Image Analysis) framework for joint image registration and biophysical inversion and we apply it to analyse MR images of glioblastomas (primary brain tumors). In particular, we consider the following problem. Given the segmentation of a normal brain MRI and the segmentation of a cancer patient MRI, we wish to determine tumor growth paramet…
▽ More
We present the SIBIA (Scalable Integrated Biophysics-based Image Analysis) framework for joint image registration and biophysical inversion and we apply it to analyse MR images of glioblastomas (primary brain tumors). In particular, we consider the following problem. Given the segmentation of a normal brain MRI and the segmentation of a cancer patient MRI, we wish to determine tumor growth parameters and a registration map so that if we "grow a tumor" (using our tumor model) in the normal segmented image and then register it to the patient segmented image, then the registration mismatch is as small as possible. We call this "the coupled problem" because it two-way couples the biophysical inversion and registration problems. In the image registration step we solve a large-deformation diffeomorphic registration problem parameterized by an Eulerian velocity field. In the biophysical inversion step we estimate parameters in a reaction-diffusion tumor growth model that is formulated as a partial differential equation.
In this paper, our contributions are the introduction of a PDE-constrained optimization formulation of the coupled problem, the derivation of the optimality conditions, and the derivation of a Picard iterative scheme for the solution of the coupled problem. In addition, we perform several tests to experimentally assess the performance of our method on synthetic and clinical datasets. We demonstrate the convergence of the SIBIA optimization solver in different usage scenarios. We demonstrate that we can accurately solve the coupled problem in three dimensions ($256^3$ resolution) in a few minutes using 11 dual-x86 nodes. Also, we demonstrate that, with our coupled approach, we can successfully register normal MRI to tumor-bearing MRI while obtaining Dice coefficients that match those achieved when registering of normal-to-normal MRI.
△ Less
Submitted 2 March, 2018; v1 submitted 15 October, 2017;
originally announced October 2017.