Skip to main content

Showing 1–7 of 7 results for author: Clark, G A

Searching in archive q-bio. Search in all archives.
.
  1. arXiv:2003.03626  [pdf

    q-bio.NC cs.RO

    Discrimination Among Multiple Cutaneous and Proprioceptive Hand Percepts Evoked by Nerve Stimulation with Utah Slanted Electrode Arrays in Human Amputees

    Authors: David M. Page, Suzanne M. Wendelken, Tyler S. Davis, David T. Kluger, Douglas T. Hutchinson, Jacob A. George, Gregory A. Clark

    Abstract: Objective: This paper aims to demonstrate functional discriminability among restored hand sensations with different locations, qualities, and intensities that are evoked by microelectrode stimulation of residual afferent fibers in human amputees. Methods: We implanted a Utah Slanted Electrode Array (USEA) in the median and ulnar residual arm nerves of three transradial amputees and delivered stimu… ▽ More

    Submitted 7 March, 2020; originally announced March 2020.

    Comments: 19 pages

  2. arXiv:2003.00070  [pdf

    cs.RO cs.CV q-bio.NC

    Inexpensive surface electromyography sleeve with consistent electrode placement enables dexterous and stable prosthetic control through deep learning

    Authors: Jacob A. George, Anna Neibling, Michael D. Paskett, Gregory A. Clark

    Abstract: The dexterity of conventional myoelectric prostheses is limited in part by the small datasets used to train the control algorithms. Variations in surface electrode positioning make it difficult to collect consistent data and to estimate motor intent reliably over time. To address these challenges, we developed an inexpensive, easy-to-don sleeve that can record robust and repeatable surface electro… ▽ More

    Submitted 28 February, 2020; originally announced March 2020.

    Comments: MEC2020

  3. arXiv:2001.08808  [pdf

    q-bio.NC cs.RO

    Intensity Discriminability of Electrocutaneous and Intraneural Stimulation Pulse Frequency in Intact Individuals and Amputees

    Authors: Jacob A. George, Mark R. Brinton, Paul C. Colgan, Garrison K. Colvin, Sliman J. Bensmaia, Gregory A. Clark

    Abstract: Electrical stimulation of residual nerves can be used to provide amputees with intuitive sensory feedback. An important aspect of this artificial sensory feedback is the ability to convey the magnitude of tactile stimuli. Using classical psychophysical methods, we quantified the just-noticeable differences for electrocutaneous stimulation pulse frequency in both intact participants and one transra… ▽ More

    Submitted 23 January, 2020; originally announced January 2020.

    Comments: IEEE EMBC 2020

  4. arXiv:2001.08807  [pdf

    cs.RO q-bio.NC

    Bilaterally Mirrored Movements Improve the Accuracy and Precision of Training Data for Supervised Learning of Neural or Myoelectric Prosthetic Control

    Authors: Jacob A. George, Troy N. Tully, Paul C. Colgan, Gregory A. Clark

    Abstract: Intuitive control of prostheses relies on training algorithms to correlate biological recordings to motor intent. The quality of the training dataset is critical to run-time performance, but it is difficult to label hand kinematics accurately after the hand has been amputated. We quantified the accuracy and precision of labeling hand kinematics for two different approaches: 1) assuming a participa… ▽ More

    Submitted 23 January, 2020; originally announced January 2020.

    Comments: IEEE EMBC 2020

  5. arXiv:2001.08805  [pdf

    cs.RO q-bio.NC

    Inexpensive and Portable System for Dexterous High-Density Myoelectric Control of Multiarticulate Prostheses

    Authors: Jacob A. George, Sridharan Radhakrishnan, Mark R. Brinton, Gregory A. Clark

    Abstract: Multiarticulate bionic arms are now capable of mimicking the endogenous movements of the human hand. 3D-printing has reduced the cost of prosthetic hands themselves, but there is currently no low-cost alternative to dexterous electromyographic (EMG) control systems. To address this need, we developed an inexpensive (~$675) and portable EMG control system by integrating low-cost microcontrollers wi… ▽ More

    Submitted 23 January, 2020; originally announced January 2020.

    Comments: IEEE EMBC 2020

  6. A Modular Transradial Bypass Socket for Surface Myoelectric Prosthetic Control in Non-Amputees

    Authors: Michael D. Paskett, Nathaniel R. Olsen, Jacob A. George, David T. Kluger, Mark R. Brinton, Tyler S. Davis, Christopher C. Duncan, Gregory A. Clark

    Abstract: Bypass sockets allow researchers to perform tests of prosthetic systems from the prosthetic user's perspective. We designed a modular upper-limb bypass socket with 3D-printed components that can be easily modified for use with a variety of terminal devices. Our bypass socket preserves access to forearm musculature and the hand, which are necessary for surface electromyography and to provide substi… ▽ More

    Submitted 26 September, 2019; v1 submitted 6 September, 2019; originally announced September 2019.

    Comments: 8 pages, 5 figures

    Journal ref: IEEE Trans. Neural Syst. Rehabil. Eng. (2019)

  7. arXiv:1908.10522  [pdf

    q-bio.NC cs.RO

    Intuitive Neuromyoelectric Control of a Dexterous Bionic Arm Using a Modified Kalman Filter

    Authors: Jacob A. George, Tyler S. Davis, Mark R. Brinton, Gregory A. Clark

    Abstract: Background: Multi-articulate prostheses are capable of performing dexterous hand movements. However, clinically available control strategies fail to provide users with intuitive, independent and proportional control over multiple degrees of freedom (DOFs) in real-time. New Method: We detail the use of a modified Kalman filter (MKF) to provide intuitive, independent and proportional control over si… ▽ More

    Submitted 10 October, 2019; v1 submitted 27 August, 2019; originally announced August 2019.

    Comments: 10 figures. Accepted in J. Neurosci. Methods (2019)