-
Femtosecond spin-state switching dynamics of spin-crossover molecules condensed in thin films
Authors:
Lea Kämmerer,
Gérald Kämmerer,
Manuel Gruber,
Jan Grunwald,
Tobias Lojewski,
Laurent Mercadier,
Loïc Le Guyader,
Robert Carley,
Cammille Carinan,
Natalia Gerasimova,
David Hickin,
Benjamin E. Van Kuiken,
Giuseppe Mercurio,
Martin Teichmann,
Senthil Kumar Kuppusamy,
Andreas Scherz,
Mario Ruben,
Klaus Sokolowski-Tinten,
Andrea Eschenlohr,
Katharina Ollefs,
Carolin Schmitz-Antoniak,
Felix Tuczek,
Peter Kratzer,
Uwe Bovensiepen,
Heiko Wende
Abstract:
The photoinduced switching of Fe(II)-based spin-crossover complexes from singlet to quintet takes place at ultrafast time scales. This a priori spin-forbidden transition triggered numerous time-resolved experiments of solvated samples to elucidate the mechanism at play. The involved intermediate states remain uncertain. We apply ultrafast x-ray spectroscopy in molecular films as a method sensitive…
▽ More
The photoinduced switching of Fe(II)-based spin-crossover complexes from singlet to quintet takes place at ultrafast time scales. This a priori spin-forbidden transition triggered numerous time-resolved experiments of solvated samples to elucidate the mechanism at play. The involved intermediate states remain uncertain. We apply ultrafast x-ray spectroscopy in molecular films as a method sensitive to spin, electronic, and nuclear degrees of freedom. Combining the progress in molecule synthesis and film growth with the opportunities at x-ray free-electron lasers, we analyze the transient evolution of the Fe L3 fine structure at room temperature. Our measurements and calculations indicate the involvement of an Fe triplet intermediate state. The high-spin state saturates at half of the available molecules, limited by molecule-molecule interaction within the film.
△ Less
Submitted 3 December, 2023;
originally announced December 2023.
-
Photon shot-noise limited transient absorption soft X-ray spectroscopy at the European XFEL
Authors:
Loïc Le Guyader,
Andrea Eschenlohr,
Martin Beye,
William Schlotter,
Florian Döring,
Cammille Carinan,
David Hickin,
Naman Agarwal,
Christine Boeglin,
Uwe Bovensiepen,
Jens Buck,
Robert Carley,
Andrea Castoldi,
Alessandro D'Elia,
Jan-Torben Delitz,
Wajid Ehsan,
Robin Engel,
Florian Erdinger,
Hans Fangohr,
Peter Fischer,
Carlo Fiorini,
Alexander Föhlisch,
Luca Gelisio,
Michael Gensch,
Natalia Gerasimova
, et al. (39 additional authors not shown)
Abstract:
Femtosecond transient soft X-ray Absorption Spectroscopy (XAS) is a very promising technique that can be employed at X-ray Free Electron Lasers (FELs) to investigate out-of-equilibrium dynamics for material and energy research. Here we present a dedicated setup for soft X-rays available at the Spectroscopy & Coherent Scattering (SCS) instrument at the European X-ray Free Electron Laser (EuXFEL). I…
▽ More
Femtosecond transient soft X-ray Absorption Spectroscopy (XAS) is a very promising technique that can be employed at X-ray Free Electron Lasers (FELs) to investigate out-of-equilibrium dynamics for material and energy research. Here we present a dedicated setup for soft X-rays available at the Spectroscopy & Coherent Scattering (SCS) instrument at the European X-ray Free Electron Laser (EuXFEL). It consists of a beam-splitting off-axis zone plate (BOZ) used in transmission to create three copies of the incoming beam, which are used to measure the transmitted intensity through the excited and unexcited sample, as well as to monitor the incoming intensity. Since these three intensity signals are detected shot-by-shot and simultaneously, this setup allows normalized shot-by-shot analysis of the transmission. For photon detection, the DSSC imaging detector, which is capable of recording up to 800 images at 4.5 MHz frame rate during the FEL burst, is employed and allows approaching the photon shot-noise limit. We review the setup and its capabilities, as well as the online and offline analysis tools provided to users.
△ Less
Submitted 4 January, 2023; v1 submitted 8 November, 2022;
originally announced November 2022.
-
Monochromatic operation of the SASE3 soft X-ray beamline at European XFEL
Authors:
N. Gerasimova,
D. La Civita,
L. Samoylova,
M. Vannoni,
R. Villanueva,
D. Hickin,
R. Carley,
R. Gort,
B. Van Kuiken,
P. Miedema,
L. Le Guyarder,
L. Mercadier,
G. Mercurio,
J. Schlappa,
M. Teichman,
A. Yaroslavtsev,
H. Sinn,
A. Scherz
Abstract:
The SASE3 soft X-ray beamline at the European XFEL has been designed and built to provide experiments with pink or monochromatic beam in the photon energy range 250 eV - 3000 eV. Here, we focus on the monochromatic operation of the SASE3 beamline and report on design and performance of the SASE3 grating monochromator. The unique capability of an FEL source to produce short femtosecond pulses of hi…
▽ More
The SASE3 soft X-ray beamline at the European XFEL has been designed and built to provide experiments with pink or monochromatic beam in the photon energy range 250 eV - 3000 eV. Here, we focus on the monochromatic operation of the SASE3 beamline and report on design and performance of the SASE3 grating monochromator. The unique capability of an FEL source to produce short femtosecond pulses of high degree of coherence challenges the monochromator design by a demand to control both photon energy and temporal resolution. The aim to transport close to transform-limited pulses poses very high demands on the optics quality, in particular on the grating. The current realization of the SASE3 monochromator is discussed in comparison with optimal design performance. Presently, the monochromator operates with two gratings: the low-resolution grating is optimized for time-resolved experiments and allows for moderate resolving power of about 2000 - 5000 along with pulse stretching of few to few tens of femtoseconds RMS, and the high-resolution grating reaches resolving power of 10000 at a cost of larger pulse stretching.
△ Less
Submitted 17 June, 2022;
originally announced June 2022.
-
Megahertz-rate Ultrafast X-ray Scattering and Holographic Imaging at the European XFEL
Authors:
Nanna Zhou Hagström,
Michael Schneider,
Nico Kerber,
Alexander Yaroslavtsev,
Erick Burgos Parra,
Marijan Beg,
Martin Lang,
Christian M. Günther,
Boris Seng,
Fabian Kammerbauer,
Horia Popescu,
Matteo Pancaldi,
Kumar Neeraj,
Debanjan Polley,
Rahul Jangid,
Stjepan B. Hrkac,
Sheena K. K. Patel,
Sergei Ovcharenko,
Diego Turenne,
Dmitriy Ksenzov,
Christine Boeglin,
Igor Pronin,
Marina Baidakova,
Clemens von Korff Schmising,
Martin Borchert
, et al. (75 additional authors not shown)
Abstract:
The advent of X-ray free-electron lasers (XFELs) has revolutionized fundamental science, from atomic to condensed matter physics, from chemistry to biology, giving researchers access to X-rays with unprecedented brightness, coherence, and pulse duration. All XFEL facilities built until recently provided X-ray pulses at a relatively low repetition rate, with limited data statistics. Here, we presen…
▽ More
The advent of X-ray free-electron lasers (XFELs) has revolutionized fundamental science, from atomic to condensed matter physics, from chemistry to biology, giving researchers access to X-rays with unprecedented brightness, coherence, and pulse duration. All XFEL facilities built until recently provided X-ray pulses at a relatively low repetition rate, with limited data statistics. Here, we present the results from the first megahertz repetition rate X-ray scattering experiments at the Spectroscopy and Coherent Scattering (SCS) instrument of the European XFEL. We illustrate the experimental capabilities that the SCS instrument offers, resulting from the operation at MHz repetition rates and the availability of the novel DSSC 2D imaging detector. Time-resolved magnetic X-ray scattering and holographic imaging experiments in solid state samples were chosen as representative, providing an ideal test-bed for operation at megahertz rates. Our results are relevant and applicable to any other non-destructive XFEL experiments in the soft X-ray range.
△ Less
Submitted 20 January, 2022; v1 submitted 17 January, 2022;
originally announced January 2022.
-
High spatial coherence and short pulse duration revealed by the Hanbury Brown and Twiss interferometry at the European XFEL
Authors:
Ruslan Khubbutdinov,
Natalia Gerasimova,
Giuseppe Mercurio,
Dameli Assalauova,
Jerome Carnis,
Luca Gelisio,
Loïc le Guyader,
Alexandr Ignatenko,
Young Yong Kim,
Benjamin van Kuiken,
Ruslan P. Kurta,
Dmitry Lapkin,
Martin Teichmann,
Alexander Yaroslavtsev,
Oleg Gorobtsov,
Aleksey P. Menushenkov,
Matthias Scholz,
Andreas Scherz,
Ivan A. Vartanyants
Abstract:
Second-order intensity interferometry was employed to study the spatial and temporal properties of the European X-ray Free-Electron Laser (EuXFEL). Measurements were performed at the soft X-ray SASE3 undulator beamline at a photon energy of 1.2 keV in the Self-Amplified Spontaneous Emission (SASE) mode. Two high-power regimes of the SASE3 undulator settings, i.e. linear and quadratic tapering at s…
▽ More
Second-order intensity interferometry was employed to study the spatial and temporal properties of the European X-ray Free-Electron Laser (EuXFEL). Measurements were performed at the soft X-ray SASE3 undulator beamline at a photon energy of 1.2 keV in the Self-Amplified Spontaneous Emission (SASE) mode. Two high-power regimes of the SASE3 undulator settings, i.e. linear and quadratic tapering at saturation, were studied in detail and compared with the linear gain regime. The statistical analysis showed an exceptionally high degree of spatial coherence up to 90% for the linear undulator tapering. Analysis of the measured data in spectral and spatial domains provided an average pulse duration of about 10 fs in our measurements. The obtained results will be valuable for the experiments requiring and exploiting short pulse duration and utilizing high coherence properties of the EuXFEL.
△ Less
Submitted 22 April, 2021;
originally announced April 2021.