-
Transverse Mode Control in Quantum Enhanced Interferometers: A Review and Recommendations for a New Generation
Authors:
Aaron W. Goodwin-Jones,
Ricardo Cabrita,
Mikhail Korobko,
Martin van Beuzekom,
Daniel D. Brown,
Viviana Fafone,
Joris van Heijningen,
Alessio Rocchi,
Mitchell G. Schiworski,
Matteo Tacca
Abstract:
Adaptive optics has made significant advancement over the past decade, becoming the essential technology in a wide variety of applications, particularly in the realm of quantum optics. One key area of impact is gravitational-wave detection, where quantum correlations are distributed over kilometer-long distances by beams with hundreds of kilowatts of optical power. Decades of development were requ…
▽ More
Adaptive optics has made significant advancement over the past decade, becoming the essential technology in a wide variety of applications, particularly in the realm of quantum optics. One key area of impact is gravitational-wave detection, where quantum correlations are distributed over kilometer-long distances by beams with hundreds of kilowatts of optical power. Decades of development were required to develop robust and stable techniques to sense mismatches between the Gaussian beams and the resonators, all while maintaining the quantum correlations. Here we summarize the crucial advancements in transverse mode control required for gravitational-wave detection. As we look towards the advanced designs of future detectors, we highlight key challenges and offer recommendations for the design of these instruments. We conclude the review with a discussion of the broader application of adaptive optics in quantum technologies: communication, computation, imaging and sensing.
△ Less
Submitted 8 November, 2023;
originally announced November 2023.
-
Single and coupled cavity mode sensing schemes using a diagnostic field
Authors:
Aaron W. Goodwin-Jones,
Haochen Zhu,
Carl Blair,
Daniel D. Brown,
Joris van Heijningen,
Li Ju,
Chunnong Zhao
Abstract:
Precise optical mode matching is of critical importance in experiments using squeezed-vacuum states. Automatic spatial-mode matching schemes have the potential to reduce losses and improve loss stability. However, in quantum-enhanced coupled-cavity experiments, such as gravitational-wave detectors, one must also ensure that the sub-cavities are also mode matched. We propose a new mode sensing sche…
▽ More
Precise optical mode matching is of critical importance in experiments using squeezed-vacuum states. Automatic spatial-mode matching schemes have the potential to reduce losses and improve loss stability. However, in quantum-enhanced coupled-cavity experiments, such as gravitational-wave detectors, one must also ensure that the sub-cavities are also mode matched. We propose a new mode sensing scheme, which works for simple and coupled cavities. The scheme requires no moving parts, nor tuning of Gouy phases. Instead a diagnostic field tuned to the HG20/LG10 mode frequency is used. The error signals are derived to be proportional to the difference in waist position, and difference in Rayleigh ranges, between the sub-cavity eigenmodes. The two error signals are separable by 90 degrees of demodulation phase. We demonstrate reasonable error signals for a simplified Einstein Telescope optical design. This work will facilitate routine use of extremely high levels of squeezing in current and future gravitational-wave detectors.
△ Less
Submitted 29 August, 2023;
originally announced August 2023.
-
The alignment of the C3 Accelerator Structures with the Rasnik alignment system
Authors:
Harry van der Graaf,
Niels van Bakel,
Bram Bouwens,
Martin Breidenbach,
Andrew Haase,
Joris van Heijningen,
Anoop Nagesh Koushik,
Emilio Nanni,
Tristan du Pree,
Nick van Remortel,
Caterina Vernieri
Abstract:
The Rasnik 3-point alignment system, now widely applied in particle physics experiments and in the instrumentation of gravitational wave experiments, can be used as N-point alignment system by daisy chain N individual 3-point systems. The conceptual implementation of Rasnik chains in C3 is presented. The proper operation of a laser diode and a CMOS image sensor in liquid nitrogen has been verified…
▽ More
The Rasnik 3-point alignment system, now widely applied in particle physics experiments and in the instrumentation of gravitational wave experiments, can be used as N-point alignment system by daisy chain N individual 3-point systems. The conceptual implementation of Rasnik chains in C3 is presented. The proper operation of a laser diode and a CMOS image sensor in liquid nitrogen has been verified. Next plans for testing a small but complete system, immersed in liquid nitrogen, are presented.
△ Less
Submitted 2 August, 2023; v1 submitted 16 July, 2023;
originally announced July 2023.
-
ETpathfinder: a cryogenic testbed for interferometric gravitational-wave detectors
Authors:
A. Utina,
A. Amato,
J. Arends,
C. Arina,
M. de Baar,
M. Baars,
P. Baer,
N. van Bakel,
W. Beaumont,
A. Bertolini,
M. van Beuzekom,
S. Biersteker,
A. Binetti,
H. J. M. ter Brake,
G. Bruno,
J. Bryant,
H. J. Bulten,
L. Busch,
P. Cebeci,
C. Collette,
S. Cooper,
R. Cornelissen,
P. Cuijpers,
M. van Dael,
S. Danilishin
, et al. (90 additional authors not shown)
Abstract:
The third-generation of gravitational wave observatories, such as the Einstein Telescope (ET) and Cosmic Explorer (CE), aim for an improvement in sensitivity of at least a factor of ten over a wide frequency range compared to the current advanced detectors. In order to inform the design of the third-generation detectors and to develop and qualify their subsystems, dedicated test facilities are req…
▽ More
The third-generation of gravitational wave observatories, such as the Einstein Telescope (ET) and Cosmic Explorer (CE), aim for an improvement in sensitivity of at least a factor of ten over a wide frequency range compared to the current advanced detectors. In order to inform the design of the third-generation detectors and to develop and qualify their subsystems, dedicated test facilities are required. ETpathfinder prototype uses full interferometer configurations and aims to provide a high sensitivity facility in a similar environment as ET. Along with the interferometry at 1550 nm and silicon test masses, ETpathfinder will focus on cryogenic technologies, lasers and optics at 2090 nm and advanced quantum-noise reduction schemes. This paper analyses the underpinning noise contributions and combines them into full noise budgets of the two initially targeted configurations: 1) operating with 1550 nm laser light and at a temperature of 18 K and 2) operating at 2090 nm wavelength and a temperature of 123 K.
△ Less
Submitted 10 June, 2022;
originally announced June 2022.
-
A cryogenic and superconducting inertial sensor for the Lunar Gravitational--Wave Antenna, the Einstein Telescope and Selene-physics
Authors:
Francesca Badaracco,
Joris V. van Heijningen,
Elvis Ferreira,
Andrea Perali
Abstract:
The Lunar Gravitational--Wave Antenna is a proposed low-frequency gravitational-wave detector on the Moon surface. It will be composed of an array of high-end cryogenic superconducting inertial sensors (CSISs). A cryogenic environment will be used in combination with superconducting materials to open up pathways to low-loss actuators and sensor mechanics. CSIS revolutionizes the (cryogenic) inerti…
▽ More
The Lunar Gravitational--Wave Antenna is a proposed low-frequency gravitational-wave detector on the Moon surface. It will be composed of an array of high-end cryogenic superconducting inertial sensors (CSISs). A cryogenic environment will be used in combination with superconducting materials to open up pathways to low-loss actuators and sensor mechanics. CSIS revolutionizes the (cryogenic) inertial sensor field with a modelled displacement sensitivity at 0.5 Hz of 3 orders of magnitude better than the current state-of-the-art. It will allow the Lunar Gravitational-Wave Antenna to be sensitive below 1 Hz, down to 1 mHz and it will also be employed in the forthcoming Einstein Telescope --a third-generation gravitational-wave detector which will make use of cryogenic technologies and that will have an enhanced sensitivity below 10 Hz. Moreover, CSIS seismic data could also be employed to obtain new insights about the Moon interior and what we can call the Selene-physics.
△ Less
Submitted 8 April, 2022;
originally announced April 2022.
-
Multi-blade monolithic Euler springs with optimised stress distribution
Authors:
J. V. van Heijningen,
J. Winterflood,
B. Wu,
L. Ju
Abstract:
Euler springs are used for vertical suspension and vibration isolation as they provide a large static supporting force with a low spring-rate and use minimal spring material. To date, multiple single-width rectangular blades of uniform thickness and stacked flat-face to flat-face have been used in the post buckled state, with half of the blades buckling in each of opposing directions. For ultra-lo…
▽ More
Euler springs are used for vertical suspension and vibration isolation as they provide a large static supporting force with a low spring-rate and use minimal spring material. To date, multiple single-width rectangular blades of uniform thickness and stacked flat-face to flat-face have been used in the post buckled state, with half of the blades buckling in each of opposing directions. For ultra-low-noise isolation the ends need to be clamped which results in stick-slip issues at the joints. In this study we investigate the benefits of forming side-by-side oppositely buckling blades from a single monolithic sheet of spring material. Additionally, we study how to distribute the stress evenly along the length of the blade by contouring its width, as well as finding the optimal contour to distribute the stress evenly around the tearing joints between oppositely bending blade sections. We show that this optimal sha** typically improves the inconveniently small spring working range by over 60 % compared to an equivalent rectangular blade.
△ Less
Submitted 6 February, 2023; v1 submitted 8 April, 2021;
originally announced April 2021.
-
A fifty-fold improvement of thermal noise limited inertial sensitivity by operating at cryogenic temperatures
Authors:
Joris Vincent van Heijningen
Abstract:
A vacuum compatible cryogenic accelerometer is presented which will reach $<0.5$ p$g$ Hz$^{-1/2}$ sensitivity from 1 mHz to 10 Hz with a maximum sensitivity of 10 f$g$ Hz$^{-1/2}$ around 10 Hz. This figure can be translated to a displacement sensitivity $<2$ fm Hz$^{-1/2}$ between 2 - 100~Hz. This will supersede the best obtained sensitivity of any motion sensor by more than three orders of magnit…
▽ More
A vacuum compatible cryogenic accelerometer is presented which will reach $<0.5$ p$g$ Hz$^{-1/2}$ sensitivity from 1 mHz to 10 Hz with a maximum sensitivity of 10 f$g$ Hz$^{-1/2}$ around 10 Hz. This figure can be translated to a displacement sensitivity $<2$ fm Hz$^{-1/2}$ between 2 - 100~Hz. This will supersede the best obtained sensitivity of any motion sensor by more than three orders of magnitude at 1~Hz. The improvement is of interest to the fields of gravitational wave instrumentation, geophysics, accelerator physics and gravitation. In current particle accelerators and proposed future gravitational wave detectors $<$10 K cryogenics are applied to the test masses in order to reduce thermal noise. This concept can benefit from the already present superconducting regime temperatures and reach a $>10^5$ signal-to-noise ratio of all terrestrial seismic spectra. The sensor may be used for control of beam-focusing cryogenic electromagnets in particle accelerators, cryogenic inertial sensing for future gravitational wave detectors and other fields.
△ Less
Submitted 13 December, 2019; v1 submitted 27 September, 2019;
originally announced September 2019.
-
Construction of KAGRA: an Underground Gravitational Wave Observatory
Authors:
T. Akutsu,
M. Ando,
S. Araki,
A. Araya,
T. Arima,
N. Aritomi,
H. Asada,
Y. Aso,
S. Atsuta,
K. Awai,
L. Baiotti,
M. A. Barton,
D. Chen,
K. Cho,
K. Craig,
R. DeSalvo,
K. Doi,
K. Eda,
Y. Enomoto,
R. Flaminio,
S. Fujibayashi,
Y. Fujii,
M. -K. Fujimoto,
M. Fukushima,
T. Furuhata
, et al. (202 additional authors not shown)
Abstract:
Major construction and initial-phase operation of a second-generation gravitational-wave detector KAGRA has been completed. The entire 3-km detector is installed underground in a mine in order to be isolated from background seismic vibrations on the surface. This allows us to achieve a good sensitivity at low frequencies and high stability of the detector. Bare-bones equipment for the interferomet…
▽ More
Major construction and initial-phase operation of a second-generation gravitational-wave detector KAGRA has been completed. The entire 3-km detector is installed underground in a mine in order to be isolated from background seismic vibrations on the surface. This allows us to achieve a good sensitivity at low frequencies and high stability of the detector. Bare-bones equipment for the interferometer operation has been installed and the first test run was accomplished in March and April of 2016 with a rather simple configuration. The initial configuration of KAGRA is named {\it iKAGRA}. In this paper, we summarize the construction of KAGRA, including the study of the advantages and challenges of building an underground detector and the operation of the iKAGRA interferometer together with the geophysics interferometer that has been constructed in the same tunnel.
△ Less
Submitted 11 December, 2017; v1 submitted 30 November, 2017;
originally announced December 2017.
-
Advanced Virgo: a 2nd generation interferometric gravitational wave detector
Authors:
F. Acernese,
M. Agathos,
K. Agatsuma,
D. Aisa,
N. Allemandou,
A. Allocca,
J. Amarni,
P. Astone,
G. Balestri,
G. Ballardin,
F. Barone,
J. -P. Baronick,
M. Barsuglia,
A. Basti,
F. Basti,
Th. S. Bauer,
V. Bavigadda,
M. Bejger,
M. G. Beker,
C. Belczynski,
D. Bersanetti,
A. Bertolini,
M. Bitossi,
M. A. Bizouard,
S. Bloemen
, et al. (209 additional authors not shown)
Abstract:
Advanced Virgo is the project to upgrade the Virgo interferometric detector of gravitational waves, with the aim of increasing the number of observable galaxies (and thus the detection rate) by three orders of magnitude. The project is now in an advanced construction phase and the assembly and integration will be completed by the end of 2015. Advanced Virgo will be part of a network with the two A…
▽ More
Advanced Virgo is the project to upgrade the Virgo interferometric detector of gravitational waves, with the aim of increasing the number of observable galaxies (and thus the detection rate) by three orders of magnitude. The project is now in an advanced construction phase and the assembly and integration will be completed by the end of 2015. Advanced Virgo will be part of a network with the two Advanced LIGO detectors in the US and GEO HF in Germany, with the goal of contributing to the early detections of gravitational waves and to opening a new observation window on the universe. In this paper we describe the main features of the Advanced Virgo detector and outline the status of the construction.
△ Less
Submitted 16 October, 2014; v1 submitted 18 August, 2014;
originally announced August 2014.
-
Reconstruction of the gravitational wave signal $h(t)$ during the Virgo science runs and independent validation with a photon calibrator
Authors:
Virgo collaboration,
T. Accadia,
F. Acernese,
M. Agathos,
A. Allocca,
P. Astone,
G. Ballardin,
F. Barone,
M. Barsuglia,
A. Basti,
Th. S. Bauer,
M. Bejger,
M . G. Beker,
C. Belczynski,
D. Bersanetti,
A. Bertolini,
M. Bitossi,
M. A. Bizouard,
M. Blom,
M. Boer,
F. Bondu,
L. Bonelli,
R. Bonnand,
V. Boschi,
L. Bosi
, et al. (171 additional authors not shown)
Abstract:
The Virgo detector is a kilometer-scale interferometer for gravitational wave detection located near Pisa (Italy). About 13 months of data were accumulated during four science runs (VSR1, VSR2, VSR3 and VSR4) between May 2007 and September 2011, with increasing sensitivity.
In this paper, the method used to reconstruct, in the range 10 Hz-10 kHz, the gravitational wave strain time series $h(t)$…
▽ More
The Virgo detector is a kilometer-scale interferometer for gravitational wave detection located near Pisa (Italy). About 13 months of data were accumulated during four science runs (VSR1, VSR2, VSR3 and VSR4) between May 2007 and September 2011, with increasing sensitivity.
In this paper, the method used to reconstruct, in the range 10 Hz-10 kHz, the gravitational wave strain time series $h(t)$ from the detector signals is described. The standard consistency checks of the reconstruction are discussed and used to estimate the systematic uncertainties of the $h(t)$ signal as a function of frequency. Finally, an independent setup, the photon calibrator, is described and used to validate the reconstructed $h(t)$ signal and the associated uncertainties.
The uncertainties of the $h(t)$ time series are estimated to be 8% in amplitude. The uncertainty of the phase of $h(t)$ is 50 mrad at 10 Hz with a frequency dependence following a delay of 8 $μ$s at high frequency. A bias lower than $4\,\mathrm{μs}$ and depending on the sky direction of the GW is also present.
△ Less
Submitted 3 July, 2014; v1 submitted 23 January, 2014;
originally announced January 2014.