  1. arXiv:0810.4630  [pdf

    physics.ins-det hep-ex

    Performance of the Two Aerogel Cherenkov Detectors of the JLab Hall A Hadron Spectrometer

    Authors: S. Marrone, B. B. Wojtsekhowski, A. Acha, E. Cisbani, M. Coman, F. Cusanno, C. W. de Jager, R. De Leo, H. Gao, F. Garibaldi, D. W. Higinbotham, M. Iodice, J. J. LeRose, D. Macchia, P. Markowitz, E. Nappia, F. Palmisano, G. M. Urciuoli, I. van der Werf, H. Xiang, L. Y. Zhu

    Abstract: We report on the design and commissioning of two silica aerogel Cherenkov detectors with different refractive indices. In particular, extraordinary performance in terms of the number of detected photoelectrons was achieved through an appropriate choice of PMT type and reflector, along with some design considerations. After four years of operation, the number of detected photoelectrons was found… ▽ More

    Submitted 25 October, 2008; originally announced October 2008.

    Comments: 18 pages, 9 Figures, 4 Tables, 44 References

    Journal ref: Nuovo Cim.B124:99-114,2009

  2. arXiv:0704.1830  [pdf, ps, other

    physics.ins-det nucl-ex

    An Electromagnetic Calorimeter for the JLab Real Compton Scattering Experiment

    Authors: D. J. Hamilton, A. Shahinyan, B. Wojtsekhowski, J. R. M. Annand, T. -H. Chang, E. Chudakov, A. Danagoulian, P. Degtyarenko, K. Egiyan, R. Gilman, V. Gorbenko, J. Hines, E. Hovhannisyan, C. E. Hyde-Wright, C. W. de Jager, A. Ketikyan, V. H. Mamyan, R. Michaels, A. M. Nathan, V. Nelyubin, I. Rachek, M. Roedelbrom, A. Petrosyan, R. Pomatsalyuk, V. Popov , et al. (4 additional authors not shown)

    Abstract: A lead-glass hodoscope calorimeter that was constructed for use in the Jefferson Lab Real Compton Scattering experiment is described. The detector provides a measurement of the coordinates and the energy of scattered photons in the GeV energy range with resolutions of 5 mm and 6%/\sqrt(Eγ [GeV]). Features of both the detector design and its performance in the high luminosity environment during the… ▽ More

    Submitted 25 September, 2015; v1 submitted 14 April, 2007; originally announced April 2007.

    Comments: text updated according to published version

    Report number: JLAB-PHY-07-633

    Journal ref: Nuclear Instruments and Methods A, Volume 643, Issue 1, 1 July 2011, Pages 17-28

  3. Accurate measurement of the electron beam polarization in JLab Hall A using Compton polarimetry

    Authors: S. Escoffier, P. Y. Bertin, M. Brossard, E. Burtin, C. Cavata, N. Colombel, C. W. de Jager, A. Delbart, D. Lhuillier, F. Marie, J. Mitchell, D. Neyret, T. Pussieux

    Abstract: A major advance in accurate electron beam polarization measurement has been achieved at Jlab Hall A with a Compton polarimeter based on a Fabry-Perot cavity photon beam amplifier. At an electron energy of 4.6 GeV and a beam current of 40 uA, a total relative uncertainty of 1.5% is typically achieved within 40 min of data taking. Under the same conditions monitoring of the polarization is accurat… ▽ More

    Submitted 27 April, 2005; originally announced April 2005.

    Comments: 21 pages, 10 figures, 4 tables, submitted to Nucl. Instr. Meth. A

    Report number: DAPNIA-05-67

    Journal ref: Nucl.Instrum.Meth.A551:563-574,2005

  4. arXiv:physics/9902011  [pdf, ps, other

    physics.ins-det hep-ex nucl-ex

    A Compton Backscattering Polarimeter for Measuring Longitudinal Electron Polarization

    Authors: I. Passchier, D. W. Higinbotham, C. W. de Jager, B. E. Norum, N. H. Papadakis, N. P. Vodinas

    Abstract: Compton backscattering polarimetry provides a fast and accurate method to measure the polarization of an electron beam in a storage ring. Since the method is non-destructive, the polarization of the electron beam can be monitored during internal target experiments. For this reason, a Compton polarimeter has been constructed at NIKHEF to measure the polarization of the longitudinally polarized el… ▽ More

    Submitted 5 February, 1999; originally announced February 1999.

    Comments: 20 pages, 10 figures

    Journal ref: Nucl.Instrum.Meth. A414 (1998) 446-458