Lightweight Thermal Management Strategies for the Silicon Detectors of CBM at FAIR
Authors:
Franz Matejcek,
Kshitij Agarwal,
CBM Collaboration
Abstract:
Lightweight thermal management is central to the design of the all-silicon Inner Tracker of the Compressed Baryonic Matter Experiment (CBM) at the Facility for Antiproton and Ion Research (FAIR). This experiment aims to study strongly interacting matter at neutron star core densities through fixed-target Au-Au collisions ($\sqrt{s_{NN}} = 2.9 - 4.9\,$GeV; up to 10$^7$ beam-target interactions per…
▽ More
Lightweight thermal management is central to the design of the all-silicon Inner Tracker of the Compressed Baryonic Matter Experiment (CBM) at the Facility for Antiproton and Ion Research (FAIR). This experiment aims to study strongly interacting matter at neutron star core densities through fixed-target Au-Au collisions ($\sqrt{s_{NN}} = 2.9 - 4.9\,$GeV; up to 10$^7$ beam-target interactions per second; polar angular acceptance of $2.5^{\circ} \leq Θ\leq 25^{\circ}$). Studies with thermal demonstrators for both the pixel-based Micro Vertex Detector and the strip-based Silicon Tracking System have validated their thermal management strategies, preparing them for series production now and global commissioning in 2028.
△ Less
Submitted 25 June, 2024;
originally announced June 2024.
-
Technical design report for the CODEX-$β$ demonstrator
Authors:
CODEX-b collaboration,
:,
Giulio Aielli,
Juliette Alimena,
James Beacham,
Eli Ben Haim,
Andras Burucs,
Roberto Cardarelli,
Matthew Charles,
Xabier Cid Vidal,
Albert De Roeck,
Biplab Dey,
Silviu Dobrescu,
Ozgur Durmus,
Mohamed Elashri,
Vladimir Gligorov,
Rebeca Gonzalez Suarez,
Thomas Gorordo,
Zarria Gray,
Conor Henderson,
Louis Henry,
Philip Ilten,
Daniel Johnson,
Jacob Kautz,
Simon Knapen
, et al. (28 additional authors not shown)
Abstract:
The CODEX-$β$ apparatus is a demonstrator for the proposed future CODEX-b experiment, a long-lived-particle detector foreseen for operation at IP8 during HL-LHC data-taking. The demonstrator project, intended to collect data in 2025, is described, with a particular focus on the design, construction, and installation of the new apparatus.
The CODEX-$β$ apparatus is a demonstrator for the proposed future CODEX-b experiment, a long-lived-particle detector foreseen for operation at IP8 during HL-LHC data-taking. The demonstrator project, intended to collect data in 2025, is described, with a particular focus on the design, construction, and installation of the new apparatus.
△ Less
Submitted 22 May, 2024;
originally announced June 2024.
-
The background model of the CUPID-Mo $0νββ$ experiment
Authors:
CUPID-Mo Collaboration,
:,
C. Augier,
A. S. Barabash,
F. Bellini,
G. Benato,
M. Beretta,
L. Bergé,
J. Billard,
Yu. A. Borovlev,
L. Cardani,
N. Casali,
A. Cazes,
E. Celi,
M. Chapellier,
D. Chiesa,
I. Dafinei,
F. A. Danevich,
M. De Jesus,
P. de Marcillac,
T. Dixon,
L. Dumoulin,
K. Eitel,
F. Ferri,
B. K. Fujikawa
, et al. (58 additional authors not shown)
Abstract:
CUPID-Mo, located in the Laboratoire Souterrain de Modane (France), was a demonstrator for the next generation $0νββ$ decay experiment, CUPID. It consisted of an array of 20 enriched Li$_{2}$$ ^{100}$MoO$_4$ bolometers and 20 Ge light detectors and has demonstrated that the technology of scintillating bolometers with particle identification capabilities is mature. Furthermore, CUPID-Mo can inform…
▽ More
CUPID-Mo, located in the Laboratoire Souterrain de Modane (France), was a demonstrator for the next generation $0νββ$ decay experiment, CUPID. It consisted of an array of 20 enriched Li$_{2}$$ ^{100}$MoO$_4$ bolometers and 20 Ge light detectors and has demonstrated that the technology of scintillating bolometers with particle identification capabilities is mature. Furthermore, CUPID-Mo can inform and validate the background prediction for CUPID. In this paper, we present a detailed model of the CUPID-Mo backgrounds. This model is able to describe well the features of the experimental data and enables studies of the $2νββ$ decay and other processes with high precision. We also measure the radio-purity of the Li$_{2}$$^{100}$MoO$_4$ crystals which are found to be sufficient for the CUPID goals. Finally, we also obtain a background index in the region of interest of 3.7$^{+0.9}_{-0.8}$(stat)$^{+1.5}_{-0.7}$(syst)$\times10^{-3}$counts/$Δ$E$_{FWHM}$/mol$_{iso}$/yr, the lowest in a bolometric $0νββ$ decay experiment.
△ Less
Submitted 2 May, 2023;
originally announced May 2023.
-
The new APD-Based Readout of the Crystal Barrel Calorimeter -- An Overview
Authors:
CBELSA/TAPS Collaboration,
:,
C. Honisch,
P. Klassen,
J. Müllers,
M. Urban,
F. Afzal,
J. Bieling,
S. Ciupka,
J. Hartmann,
P. Hoffmeister,
M. Lang,
D. Schaab,
C. Schmidt,
M. Steinacher,
D. Walther,
R. Beck,
K. -T. Brinkmann,
V. Crede,
H. Dutz,
D. Elsner,
W. Erni,
E. Fix,
F. Frommberger,
M. Grüner
, et al. (26 additional authors not shown)
Abstract:
The Crystal Barrel is an electromagnetic calorimeter consisting of 1380 CsI(Tl) scintillators, and is currently installed at the CBELSA/TAPS experiment where it is used to detect decay products from photoproduction of mesons. The readout of the Crystal Barrel has been upgraded in order to integrate the detector into the first level of the trigger and to increase its sensitivity for neutral final s…
▽ More
The Crystal Barrel is an electromagnetic calorimeter consisting of 1380 CsI(Tl) scintillators, and is currently installed at the CBELSA/TAPS experiment where it is used to detect decay products from photoproduction of mesons. The readout of the Crystal Barrel has been upgraded in order to integrate the detector into the first level of the trigger and to increase its sensitivity for neutral final states. The new readout uses avalanche photodiodes in the front-end and a dual back-end with branches optimized for energy and time measurement, respectively. An FPGA-based cluster finder processes the whole hit pattern within less than 100 ns. The important downside of APDs -- the temperature dependence of their gain -- is handled with a temperature stabilization and a compensating bias voltage supply. Additionally, a light pulser system allows the APDs' gains to be measured during beamtimes.
△ Less
Submitted 16 January, 2023; v1 submitted 23 December, 2022;
originally announced December 2022.
-
Search for Majoron-like particles with CUPID-0
Authors:
CUPID-0 Collaboration,
:,
O. Azzolini,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
C. Brofferio,
C. Bucci,
S. Capelli,
V. Caracciolo,
L. Cardani,
P. Carniti,
N. Casali,
E. Celi,
D. Chiesa,
M. Clemenza,
I. Colantoni,
O. Cremonesi,
A. Cruciani,
A. D'Addabbo,
I. Dafinei,
S. Di Domizio,
V. Dompè,
G. Fantini
, et al. (29 additional authors not shown)
Abstract:
We present the first search for the Majoron-emitting modes of the neutrinoless double $β$ decay ($0νββχ_0$) using scintillating cryogenic calorimeters. We analysed the CUPID-0 Phase I data using a Bayesian approach to reconstruct the background sources activities, and evaluate the potential contribution of the $^{82}$Se $0νββχ_0$. We considered several possible theoretical models which predict the…
▽ More
We present the first search for the Majoron-emitting modes of the neutrinoless double $β$ decay ($0νββχ_0$) using scintillating cryogenic calorimeters. We analysed the CUPID-0 Phase I data using a Bayesian approach to reconstruct the background sources activities, and evaluate the potential contribution of the $^{82}$Se $0νββχ_0$. We considered several possible theoretical models which predict the existence of a Majoron-like boson coupling to the neutrino. The energy spectra arising from the emission of such bosons in the neutrinoless double $β$ decay have spectral indices $n=$ 1, 2, 3 or 7. We found no evidence of any of these decay modes, setting a lower limit (90% of credibility interval) on the half-life of 1.2 $\times$ 10$^{23}$ yr in the case of $n=$ 1, 3.8 $\times$ 10$^{22}$ yr for $n=$ 2, 1.4 $\times$ 10$^{22}$ yr for $n=$ 3 and 2.2 $\times$ 10$^{21}$ yr for $n=$ 7. These are the best limits on the $0νββχ_0$ half-life of the $^{82}$Se, and demonstrate the potentiality of the CUPID-0 technology in this field.
△ Less
Submitted 20 September, 2022;
originally announced September 2022.
-
CCAT-prime: The 850 GHz camera for Prime-Cam on FYST
Authors:
Scott C. Chapman,
Anthony I. Huber,
Adrian K. Sinclair,
Jordan D. Wheeler,
Jason E. Austermann,
James Beall,
James Burgoyne,
Steve K. Choi,
Abigail Crites,
Cody J. Duell,
Jesslyn Devina,
Jiansong Gao,
Mike Fich,
Doug Henke,
Terry Herter,
Doug Johnstone,
Lewis B. G. Knee,
Michael D. Niemack,
Kayla M. Rossi,
Gordon Stacey,
Joel Tsuchitori,
Joel Ullom,
Jeff Van Lanen,
Eve M. Vavagiakis,
Michael Vissers
, et al. (1 additional authors not shown)
Abstract:
The Fred Young Submillimeter Telescope (FYST) at the Cerro-Chajnantor Atacama Telescope prime (CCAT- prime) Facility will host Prime-Cam as a powerful, first generation camera with imaging polarimeters working at several wavelengths and spectroscopic instruments aimed at intensity map** during the Epoch of Reionization. Here we introduce the 850 GHz (350 micron) instrument module. This will be t…
▽ More
The Fred Young Submillimeter Telescope (FYST) at the Cerro-Chajnantor Atacama Telescope prime (CCAT- prime) Facility will host Prime-Cam as a powerful, first generation camera with imaging polarimeters working at several wavelengths and spectroscopic instruments aimed at intensity map** during the Epoch of Reionization. Here we introduce the 850 GHz (350 micron) instrument module. This will be the highest frequency module in Prime-Cam and the most novel for astronomical and cosmological surveys, taking full advantage of the atmospheric transparency at the high 5600 meter CCAT-prime siting on Cerro Chajnantor. With a 1.1 deg diameter field, the 850 GHz module will deploy ~40,000 Kinetic Inductance Detectors (KIDs) with Silicon platelet feedhorn coupling (both fabricated at NIST), and will provide unprecedented broadband intensity and polarization measurement capabilities. The 850 GHz module will be key to addressing pressing astrophysical questions regarding galaxy formation, Big Bang cosmology, and star formation within our own Galaxy. We present the motivation and overall design for the module, and initial laboratory characterization.
△ Less
Submitted 22 August, 2022;
originally announced August 2022.
-
CCAT-prime: RFSoC Based Readout for Frequency Multiplexed Kinetic Inductance Detectors
Authors:
Adrian K. Sinclair,
Ryan C. Stephenson,
Cody A. Roberson,
Eric L. Weeks,
James Burgoyne,
Anthony I. Huber,
Philip M. Mauskopf,
Scott C. Chapman,
Jason E. Austermann,
Steve K. Choi,
Cody J. Duell,
Michel Fich,
Christopher E. Groppi,
Zachary Huber,
Michael D. Niemack,
Thomas Nikola,
Kayla M. Rossi,
Adhitya Sriram,
Gordon J. Stacey,
Erik Szakiel,
Joel Tsuchitori,
Eve M. Vavagiakis,
Jordan D. Wheeler,
the CCAT-prime collaboration
Abstract:
The Prime-Cam instrument on the Fred Young Submillimeter Telescope (FYST) is expected to be the largest deployment of millimeter and submillimeter sensitive kinetic inductance detectors to date. To read out these arrays efficiently, a microwave frequency multiplexed readout has been designed to run on the Xilinx Radio Frequency System on a Chip (RFSoC). The RFSoC has dramatically improved every ca…
▽ More
The Prime-Cam instrument on the Fred Young Submillimeter Telescope (FYST) is expected to be the largest deployment of millimeter and submillimeter sensitive kinetic inductance detectors to date. To read out these arrays efficiently, a microwave frequency multiplexed readout has been designed to run on the Xilinx Radio Frequency System on a Chip (RFSoC). The RFSoC has dramatically improved every category of size, weight, power, cost, and bandwidth over the previous generation readout systems. We describe a baseline firmware design which can read out four independent RF networks each with 500 MHz of bandwidth and 1000 detectors for ~30 W. The overall readout architecture is a combination of hardware, gateware/firmware, software, and network design. The requirements of the readout are driven by the 850 GHz instrument module of the 7-module Prime-Cam instrument. These requirements along with other constraints which have led to critical design choices are highlighted. Preliminary measurements of the system phase noise and dynamic range are presented.
△ Less
Submitted 15 August, 2022;
originally announced August 2022.
-
Optical design concept of the CMB-S4 large-aperture telescopes and cameras
Authors:
Patricio A. Gallardo,
Bradford Benson,
John Carlstrom,
Simon R. Dicker,
Nick Emerson,
Jon E. Gudmundsson,
Richard Hills,
Michele Limon,
Jeff McMahon,
Michael D. Niemack,
Johanna M. Nagy,
Stephen Padin,
John Ruhl,
Sara M. Simon,
the CMB-S4 collaboration
Abstract:
CMB-S4 -- the next-generation ground-based cosmic microwave background (CMB) experiment - will significantly advance the sensitivity of CMB measurements and improve our understanding of the origin and evolution of the universe. CMB-S4 will deploy large-aperture telescopes fielding hundreds of thousands of detectors at millimeter wavelengths. We present the baseline optical design concept of the la…
▽ More
CMB-S4 -- the next-generation ground-based cosmic microwave background (CMB) experiment - will significantly advance the sensitivity of CMB measurements and improve our understanding of the origin and evolution of the universe. CMB-S4 will deploy large-aperture telescopes fielding hundreds of thousands of detectors at millimeter wavelengths. We present the baseline optical design concept of the large-aperture CMB-S4 telescopes, which consists of two optical configurations: (i) a new off-axis, three-mirror, free-form anastigmatic design and (ii) the existing coma-corrected crossed-Dragone design. We also present an overview of the optical configuration of the array of silicon optics cameras that will populate the focal plane with 85 diffraction-limited optics tubes covering up to 9 degrees of field of view, up to $1.1 \, \rm mm$ in wavelength. We describe the computational optimization methods that were put in place to implement the families of designs described here and give a brief update on the current status of the design effort.
△ Less
Submitted 20 July, 2022;
originally announced July 2022.
-
Three-year annual modulation search with COSINE-100
Authors:
COSINE-100 Collaboration,
:,
G. Adhikari,
E. Barbosa de Souza,
N. Carlin,
J. J. Choi,
S. Choi,
A. C. Ezeribe,
L. E. França,
C. Ha,
I. S. Hahn,
S. J. Hollick,
E. J. Jeon,
J. H. Jo,
H. W. Joo,
W. G. Kang,
M. Kauer,
H. Kim,
H. J. Kim,
J. Kim,
K. W. Kim,
S. H. Kim,
S. K. Kim,
W. K. Kim,
Y. D. Kim
, et al. (34 additional authors not shown)
Abstract:
COSINE-100 is a direct detection dark matter experiment that aims to test DAMA/LIBRA's claim of dark matter discovery by searching for a dark matter-induced annual modulation signal with NaI(Tl) detectors. We present new constraints on the annual modulation signal from a dataset with a 2.82 yr livetime utilizing an active mass of 61.3 kg, for a total exposure of 173 kg$\cdot$yr. This new result fe…
▽ More
COSINE-100 is a direct detection dark matter experiment that aims to test DAMA/LIBRA's claim of dark matter discovery by searching for a dark matter-induced annual modulation signal with NaI(Tl) detectors. We present new constraints on the annual modulation signal from a dataset with a 2.82 yr livetime utilizing an active mass of 61.3 kg, for a total exposure of 173 kg$\cdot$yr. This new result features an improved event selection that allows for both lowering the energy threshold to 1 keV and a more precise time-dependent background model. In the 1-6 keV and 2-6 keV energy intervals, we observe best-fit values for the modulation amplitude of 0.0067$\pm$0.0042 and 0.0051$\pm$0.0047 counts/(day$\cdot$kg$\cdot$keV), respectively, with a phase fixed at 152.5 days.
△ Less
Submitted 28 October, 2022; v1 submitted 16 November, 2021;
originally announced November 2021.
-
Back-n White Neutron Source at CSNS and its Applications
Authors:
The CSNS Back-n Collaboration,
:,
**g-Yu Tang,
Qi An,
Jiang-Bo Bai,
Jie Bao,
Yu Bao,
** Cao,
Hao-Lei Chen,
Qi-** Chen,
Yong-Hao Chen,
Zhen Chen,
Zeng-Qi Cui,
Rui-Rui Fan,
Chang-Qing Feng,
Ke-Qing Gao,
Xiao-Long Gao,
Min-Hao Gu,
Chang-Cai Han,
Zi-Jie Han,
Guo-Zhu He,
Yong-Cheng He,
Yang Hong,
Yi-Wei Hu,
Han-Xiong Huang
, et al. (52 additional authors not shown)
Abstract:
Back-streaming neutrons from the spallation target of the China Spallation Neutron Source (CSNS) that emit through the incoming proton channel were exploited to build a white neutron beam facility (the so-called Back-n white neutron source), which was completed in March 2018. The Back-n neutron beam is very intense, at approximately 2*10^7 n/cm^2/s at 55 m from the target, and has a nominal proton…
▽ More
Back-streaming neutrons from the spallation target of the China Spallation Neutron Source (CSNS) that emit through the incoming proton channel were exploited to build a white neutron beam facility (the so-called Back-n white neutron source), which was completed in March 2018. The Back-n neutron beam is very intense, at approximately 2*10^7 n/cm^2/s at 55 m from the target, and has a nominal proton beam with a power of 100 kW in the CSNS-I phase and a kinetic energy of 1.6 GeV and a thick tungsten target in multiple slices with modest moderation from the cooling water through the slices. In addition, the excellent energy spectrum spanning from 0.5 eV to 200 MeV, and a good time resolution related to the time-of-flight measurements make it a typical white neutron source for nuclear data measurements; its overall performance is among that of the best white neutron sources in the world. Equipped with advanced spectrometers, detectors, and application utilities, the Back-n facility can serve wide applications, with a focus on neutron-induced cross-section measurements. This article presents an overview of the neutron beam characteristics, the experimental setups, and the ongoing applications at Back-n.
△ Less
Submitted 16 January, 2021;
originally announced January 2021.
-
Measurement of the cosmic muon annual and diurnal flux variation with the COSINE-100 detector
Authors:
COSINE-100 Collaboration,
:,
H. Prihtiadi,
G. Adhikari,
E. Barbosa de Souza,
N. Carlin,
J. J. Choi,
S. Choi,
M. Djamal,
A. C. Ezeribe,
L. E. França,
C. Ha,
I. S. Hahn,
E. J. Jeon,
J. H. Jo,
W. G. Kang,
M. Kauer,
H. Kim,
H. J. Kim,
K. W. Kim,
S. K. Kim,
Y. D. Kim,
Y. H. Kim,
Y. J. Ko,
E. K. Lee
, et al. (23 additional authors not shown)
Abstract:
We report measurements of annual and diurnal modulations of the cosmic-ray muon rate in the Yangyang underground laboratory (Y2L) using 952 days of COSINE-100 data acquired between September 2016 and July 2019. A correlation of the muon rate with the atmospheric temperature is observed and its amplitude on the muon rate is determined. The effective atmospheric temperature and muon rate variations…
▽ More
We report measurements of annual and diurnal modulations of the cosmic-ray muon rate in the Yangyang underground laboratory (Y2L) using 952 days of COSINE-100 data acquired between September 2016 and July 2019. A correlation of the muon rate with the atmospheric temperature is observed and its amplitude on the muon rate is determined. The effective atmospheric temperature and muon rate variations are positively correlated with a measured effective temperature coefficient of $α_{T}$ = 0.80 $\pm$ 0.11. This result is consistent with a model of meson production in the atmosphere. We also searched for a diurnal modulation in the underground muon rate by comparing one-hour intervals. No significant diurnal modulation of the muon rate was observed.
△ Less
Submitted 28 May, 2020; v1 submitted 27 May, 2020;
originally announced May 2020.
-
Search for a Dark Matter-Induced Annual Modulation Signal in NaI(Tl) with the COSINE-100 Experiment
Authors:
COSINE-100 Collaboration,
:,
G. Adhikari,
P. Adhikari,
E. Barbosa de Souza,
N. Carlin,
S. Choi,
M. Djamal,
A. C. Ezeribe,
C. Ha,
I. S. Hahn,
E. J. Jeon,
J. H. Jo,
H. W. Joo,
W. G. Kang,
W. Kang,
M. Kauer,
G. S. Kim,
H. Kim,
H. J. Kim,
K. W. Kim,
N. Y. Kim,
S. K. Kim,
Y. D. Kim,
Y. H. Kim
, et al. (25 additional authors not shown)
Abstract:
We present new constraints on the dark matter-induced annual modulation signal using 1.7 years, of COSINE-100 data with a total exposure of 97.7 kg$\cdot$years. The COSINE-100 experiment, consisting of 106 kg of NaI(Tl) target material, is designed to carry out a model-independent test of DAMA/LIBRA's claim of WIMP discovery by searching for the same annual modulation signal using the same NaI(Tl)…
▽ More
We present new constraints on the dark matter-induced annual modulation signal using 1.7 years, of COSINE-100 data with a total exposure of 97.7 kg$\cdot$years. The COSINE-100 experiment, consisting of 106 kg of NaI(Tl) target material, is designed to carry out a model-independent test of DAMA/LIBRA's claim of WIMP discovery by searching for the same annual modulation signal using the same NaI(Tl) target. The crystal data show a 2.7 cpd/kg/keV background rate on average in the 2--6 keV energy region of interest. Using a $χ$-squared minimization method we observe best fit values for modulation amplitude and phase of 0.0092$\pm$0.0067 cpd/kg/keV and 127.2$\pm$45 d, respectively.
△ Less
Submitted 25 July, 2019; v1 submitted 24 March, 2019;
originally announced March 2019.
-
Layout and Assembly Technique of the GEM Chambers for the Upgrade of the CMS First Muon Endcap Station
Authors:
Aashaq Shah,
CMS-Muon Collaboration
Abstract:
Triple-GEM detector technology was recently selected by CMS for a part of the upgrade of its forward muon detector system as GEM detectors provide a stable operation in the high radiation environment expected during the future High-Luminosity phase of the Large Hadron Collider (HL-LHC). In a first step, GEM chambers (detectors) will be installed in the innermost muon endcap station in the…
▽ More
Triple-GEM detector technology was recently selected by CMS for a part of the upgrade of its forward muon detector system as GEM detectors provide a stable operation in the high radiation environment expected during the future High-Luminosity phase of the Large Hadron Collider (HL-LHC). In a first step, GEM chambers (detectors) will be installed in the innermost muon endcap station in the $1.6<\left|η\right|<2.2$ pseudo-rapidity region, mainly to control level-1 muon trigger rates after the second LHC Long Shutdown. These new chambers will add redundancy to the muon system in the $η$-region where the background rates are high, and the bending of the muon trajectories due to the CMS magnetic field is small. A novel construction technique for such chambers has been developed in such a way where foils are mounted onto a single stack and then uniformly stretched mechanically, avoiding the use of spacers and glue inside the active gas volume. We describe the layout, the stretching mechanism and the overall assembly technique of such GEM chambers.
△ Less
Submitted 11 December, 2018; v1 submitted 2 December, 2018;
originally announced December 2018.
-
The COSINE-100 Data Acquisition System
Authors:
COSINE-100 Collaboration,
:,
G. Adhikari,
P. Adhikari,
E. Barbosa de Souza,
N. Carlin,
S. Choi,
W. Choi,
M. Djamal,
A. C. Ezeribe,
C. Ha,
I. S. Hahn,
A. J. F. Hubbard,
E. J. Jeon,
J. H. Jo,
H. W. Joo,
W. G. Kang,
W. S. Kang,
M. Kauer,
H. Kim,
H. J. Kim,
K. W. Kim,
M. C. Kim,
N. Y. Kim,
S. K. Kim
, et al. (23 additional authors not shown)
Abstract:
COSINE-100 is a dark matter direct detection experiment designed to test the annual modulation signal observed by the DAMA/LIBRA experiment. COSINE-100 consists of 8 NaI(Tl) crystals with a total mass of 106 kg, a 2200 L liquid scintillator veto, and 37 muon detector panels. We present details of the data acquisition system of COSINE-100, including waveform storage using flash analog-to-digital co…
▽ More
COSINE-100 is a dark matter direct detection experiment designed to test the annual modulation signal observed by the DAMA/LIBRA experiment. COSINE-100 consists of 8 NaI(Tl) crystals with a total mass of 106 kg, a 2200 L liquid scintillator veto, and 37 muon detector panels. We present details of the data acquisition system of COSINE-100, including waveform storage using flash analog-to-digital converters for crystal events and integrated charge storage using charge-sensitive analog-to-digital converters for liquid scintillator and plastic scintillator muon veto events. We also discuss several trigger conditions developed in order to distinguish signal events from photomultiplier noise events. The total trigger rate observed for the crystal/liquid scintillator (plastic scintillator) detector is 15 Hz (24 Hz).
△ Less
Submitted 26 June, 2018;
originally announced June 2018.
-
Study of the CMS Phase-1 Pixel Pilot Blade Reconstruction
Authors:
Tamas Almos Vami,
Viktor Veszpremi,
the CMS Collaboration
Abstract:
The Compact Muon Solenoid (CMS) detector is one of two general-purpose detectors that measure the products of high energy particle interactions in the Large Hadron Collider (LHC) at CERN. The silicon pixel detector is the innermost component of the CMS tracking system. The detector which was in operation between 2009 and 2016 has now been replaced with an upgraded one in the beginning of 2017. Dur…
▽ More
The Compact Muon Solenoid (CMS) detector is one of two general-purpose detectors that measure the products of high energy particle interactions in the Large Hadron Collider (LHC) at CERN. The silicon pixel detector is the innermost component of the CMS tracking system. The detector which was in operation between 2009 and 2016 has now been replaced with an upgraded one in the beginning of 2017. During the previous shutdown period of the LHC, a prototype readout system and a third disk was inserted into the old forward pixel detector with eight prototype blades constructed using the new digital read-out chips. Testing the performance of these pilot modules enabled us to gain operational experience with the upgraded detector. In this paper, the reconstruction and analysis of the data taken with the new modules are presented including information on the calibration of the reconstruction software. The hit finding efficiency and track-hit residual distributions are also shown.
△ Less
Submitted 2 April, 2018;
originally announced April 2018.
-
First Result on the Neutrinoless Double Beta Decay of $^{82}$Se with CUPID-0
Authors:
CUPID-0 collaboration,
:,
O. Azzolini,
M. T. Barrera,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
C. Brofferio,
C. Bucci,
L. Canonica,
S. Capelli,
L. Cardani,
P. Carniti,
N. Casali,
L. Cassina,
M. Clemenza,
O. Cremonesi,
A. Cruciani,
A. D'Addabbo,
I. Dafinei,
S. Di Domizio,
F. Ferroni,
L. Gironi,
A. Giuliani
, et al. (28 additional authors not shown)
Abstract:
We report the result of the search for neutrinoless double beta decay of $^{82}$Se obtained with CUPID-0, the first large array of scintillating Zn$^{82}$Se cryogenic calorimeters implementing particle identification. We observe no signal in a 1.83 kg yr $^{82}$Se exposure and we set the most stringent lower limit on the \onu $^{82}$Se half-life T$^{0ν}_{1/2}>$ 2.4$\times \mathrm{10}^{24}$ yr (90\…
▽ More
We report the result of the search for neutrinoless double beta decay of $^{82}$Se obtained with CUPID-0, the first large array of scintillating Zn$^{82}$Se cryogenic calorimeters implementing particle identification. We observe no signal in a 1.83 kg yr $^{82}$Se exposure and we set the most stringent lower limit on the \onu $^{82}$Se half-life T$^{0ν}_{1/2}>$ 2.4$\times \mathrm{10}^{24}$ yr (90\% credible interval), which corresponds to an effective Majorana neutrino mass m$_{ββ} <$ (376-770) meV depending on the nuclear matrix element calculations. The heat-light readout provides a powerful tool for the rejection of \al\ particles and allows to suppress the background in the region of interest down to (3.6$^{+1.9}_{-1.4}$)$\times$10$^{-3}$\ckky, an unprecedented level for this technique.
△ Less
Submitted 5 June, 2018; v1 submitted 21 February, 2018;
originally announced February 2018.
-
CDEX dark matter experiment: Status and prospects
Authors:
Hao Ma,
Yang Chen,
Qian Yue,
Li Wang,
Tao Xue,
Zhi Zeng,
Kejun Kang,
Jian** Cheng,
Yuan**g Li,
Jianmin Li,
Yulan Li for CDEX Collaboration
Abstract:
The China Dark Matter Experiment (CDEX) aims at direct searches of light Weakly Interacting Massive Particles (WIMPs) at the China **** Underground Laboratory (CJPL) with an overburden of about 2400m rock. Results from a prototype CDEX-1 994 g p-type Point Contact Germanium(pPCGe) detector are reported. Research programs are pursued to further reduce the physics threshold by improving hardware…
▽ More
The China Dark Matter Experiment (CDEX) aims at direct searches of light Weakly Interacting Massive Particles (WIMPs) at the China **** Underground Laboratory (CJPL) with an overburden of about 2400m rock. Results from a prototype CDEX-1 994 g p-type Point Contact Germanium(pPCGe) detector are reported. Research programs are pursued to further reduce the physics threshold by improving hardware and data analysis. The CDEX-10 experiment with a pPCGe array of 10 kg target mass range is being tested. The evolution of CDEX program into "CDEX-1T Experiment" with ton-scale germanium detector arrays will also be introduced in this study.
△ Less
Submitted 24 January, 2019; v1 submitted 16 December, 2017;
originally announced December 2017.
-
Muon detector for the COSINE-100 experiment
Authors:
COSINE-100 Collaboration,
:,
H. Prihtiadi,
G. Adhikari,
P. Adhikari,
E. Barbosa de Souza,
N. Carlin,
S. Choi,
W. Q. Choi,
M. Djamal,
A. C. Ezeribe,
C. Ha,
I. S. Hahn,
A. J. F. Hubbard,
E. J. Jeon,
J. H. Jo,
H. W. Joo,
W. Kang,
W. G. Kang,
M. Kauer,
B. H. Kim,
H. Kim,
H. J. Kim,
K. W. Kim,
N. Y. Kim
, et al. (28 additional authors not shown)
Abstract:
The COSINE-100 dark matter search experiment has started taking physics data with the goal of performing an independent measurement of the annual modulation signal observed by DAMA/LIBRA. A muon detector was constructed by using plastic scintillator panels in the outermost layer of the shield surrounding the COSINE-100 detector. It is used to detect cosmic ray muons in order to understand the impa…
▽ More
The COSINE-100 dark matter search experiment has started taking physics data with the goal of performing an independent measurement of the annual modulation signal observed by DAMA/LIBRA. A muon detector was constructed by using plastic scintillator panels in the outermost layer of the shield surrounding the COSINE-100 detector. It is used to detect cosmic ray muons in order to understand the impact of the muon annual modulation on dark matter analysis. Assembly and initial performance test of each module have been performed at a ground laboratory. The installation of the detector in Yangyang Underground Laboratory (Y2L) was completed in the summer of 2016. Using three months of data, the muon underground flux was measured to be 328 $\pm$ 1(stat.)$\pm$ 10(syst.) muons/m$^2$/day. In this report, the assembly of the muon detector and the results from the analysis are presented.
△ Less
Submitted 5 December, 2017;
originally announced December 2017.
-
Brightness and uniformity measurements of plastic scintillator tiles at the CERN H2 test beam
Authors:
CMS-HCAL collaboration
Abstract:
We study the light output, light collection efficiency and signal timing of a variety of organic scintillators that are being considered for the upgrade of the hadronic calorimeter of the CMS detector. The experimental data are collected at the H2 test-beam area at CERN, using a 150 GeV muon beam. In particular, we investigate the usage of over-doped and green-emitting plastic scintillator, two so…
▽ More
We study the light output, light collection efficiency and signal timing of a variety of organic scintillators that are being considered for the upgrade of the hadronic calorimeter of the CMS detector. The experimental data are collected at the H2 test-beam area at CERN, using a 150 GeV muon beam. In particular, we investigate the usage of over-doped and green-emitting plastic scintillator, two solutions that have not been extensively considered. We present a study of the energy distribution in plastic-scintillator tiles, the hit efficiency as a function of the hit position, and a study of the signal timing for blue and green scintillators.
△ Less
Submitted 30 November, 2017; v1 submitted 25 September, 2017;
originally announced September 2017.
-
Dose rate effects in the radiation damage of the plastic scintillators of the CMS Hadron Endcap Calorimeter
Authors:
CMS-HCAL collaboration
Abstract:
We present measurements of the reduction of light output by plastic scintillators irradiated in the CMS detector during the 8 TeV run of the Large Hadron Collider and show that they indicate a strong dose rate effect. The damage for a given dose is larger for lower dose rate exposures. The results agree with previous measurements of dose rate effects, but are stronger due to the very low dose rate…
▽ More
We present measurements of the reduction of light output by plastic scintillators irradiated in the CMS detector during the 8 TeV run of the Large Hadron Collider and show that they indicate a strong dose rate effect. The damage for a given dose is larger for lower dose rate exposures. The results agree with previous measurements of dose rate effects, but are stronger due to the very low dose rates probed. We show that the scaling with dose rate is consistent with that expected from diffusion effects.
△ Less
Submitted 16 September, 2016; v1 submitted 25 August, 2016;
originally announced August 2016.
-
Strangeness Suppression in q-qbar Creation Observed in Exclusive Reactions
Authors:
K. Park,
M. D. Mestayer,
the CLAS collaboration
Abstract:
We measured the ratios of electroproduction cross-sections from a proton target for three exclusive meson-baryon final states: $ΛK^+$, $pπ^0$, and $nπ^+$, with the CLAS detector at Jefferson Lab. Using a simple model of quark hadronization we extract q-qbar creation probabilities for the first time in exclusive two-body production, in which only a single q-qbar pair is created. We observe a sizabl…
▽ More
We measured the ratios of electroproduction cross-sections from a proton target for three exclusive meson-baryon final states: $ΛK^+$, $pπ^0$, and $nπ^+$, with the CLAS detector at Jefferson Lab. Using a simple model of quark hadronization we extract q-qbar creation probabilities for the first time in exclusive two-body production, in which only a single q-qbar pair is created. We observe a sizable suppression of strange quark-antiquark pairs compared to non-strange pairs, similar to that seen in high-energy production.
△ Less
Submitted 8 December, 2014; v1 submitted 2 December, 2014;
originally announced December 2014.
-
Energy Linearity and Resolution of the ATLAS Electromagnetic Barrel Calorimeter in an Electron Test-Beam
Authors:
M. Aharrouche,
ATLAS Electromagnetic Barrel Calorimeter Collaboration
Abstract:
A module of the ATLAS electromagnetic barrel liquid argon calorimeter was exposed to the CERN electron test-beam at the H8 beam line upgraded for precision momentum measurement. The available energies of the electron beam ranged from 10 to 245 GeV. The electron beam im**ed at one point corresponding to a pseudo-rapidity of eta=0.687 and an azimuthal angle of phi=0.28 in the ATLAS coordinate sy…
▽ More
A module of the ATLAS electromagnetic barrel liquid argon calorimeter was exposed to the CERN electron test-beam at the H8 beam line upgraded for precision momentum measurement. The available energies of the electron beam ranged from 10 to 245 GeV. The electron beam im**ed at one point corresponding to a pseudo-rapidity of eta=0.687 and an azimuthal angle of phi=0.28 in the ATLAS coordinate system. A detailed study of several effects biasing the electron energy measurement allowed an energy reconstruction procedure to be developed that ensures a good linearity and a good resolution. Use is made of detailed Monte Carlo simulations based on Geant which describe the longitudinal and transverse shower profiles as well as the energy distributions. For electron energies between 15 GeV and 180 GeV the deviation of the measured incident electron energy over the beam energy is within 0.1%. The systematic uncertainty of the measurement is about 0.1% at low energies and negligible at high energies. The energy resolution is found to be about 10% sqrt(E) for the sampling term and about 0.2% for the local constant term.
△ Less
Submitted 1 August, 2006;
originally announced August 2006.
-
The Neutrino Factory and Beta Beam Experiments and Development
Authors:
C. Albright,
V. Barger,
J. Beacom,
S. Brice,
J. J. Gomez-Cadenas,
M. Goodman,
D. Harris,
P. Huber,
A. Jansson,
M. Lindner,
O. Mena,
P. Rapidis,
K. Whisnant,
W. Winter,
The Neutrino Factory,
Muon Collider Collaboration
Abstract:
The long-term prospects for fully exploring three-flavor mixing in the neutrino sector depend upon an ongoing and increased investment in the appropriate accelerator R&D. Two new concepts have been proposed that would revolutionize neutrino experiments, namely the Neutrino Factory and the Beta Beam facility. These new facilities would dramatically improve our ability to test the three-flavor mix…
▽ More
The long-term prospects for fully exploring three-flavor mixing in the neutrino sector depend upon an ongoing and increased investment in the appropriate accelerator R&D. Two new concepts have been proposed that would revolutionize neutrino experiments, namely the Neutrino Factory and the Beta Beam facility. These new facilities would dramatically improve our ability to test the three-flavor mixing framework, measure \textsl{CP} violation in the lepton sector, and perhaps determine the neutrino mass hierarchy, and, if necessary, probe extremely small values of the mixing angle $θ_{13}$. The stunning sensitivity that could be achieved with a Neutrino Factory is described, together with our present understanding of the corresponding sensitivity that might be achieved with a Beta Beam facility. In the Beta Beam case, additional study is required to better understand the optimum Beta Beam energy, and the achievable sensitivity. Neither a Neutrino Factory nor a Beta Beam facility could be built without significant R&D. An impressive Neutrino Factory R&D effort has been ongoing in the U.S. and elsewhere over the last few years and significant progress has been made towards optimizing the design, develo** and testing the required accelerator components, and significantly reducing the cost. The recent progress is described here.
△ Less
Submitted 23 November, 2004; v1 submitted 12 November, 2004;
originally announced November 2004.