Skip to main content

Showing 1–5 of 5 results for author: Zucchiatti, A

Searching in archive physics. Search in all archives.
.
  1. Cross sections of X-ray production induced on Ti, Fe, Zn, Nb and Ta by O, Cl, Cu and Br ions with energies between 4 MeV and 40 MeV

    Authors: J. E. Prieto, P. Galan, A. Zucchiatti

    Abstract: Differential cross section of X-ray production induced by O, Cl, Cu and Br ions with energies between 4 MeV and 40 MeV have been measured for thin targets of Ti, Fe, Zn, Nb and Ta in a direct way. A fully characterized silicon drift diode was used as X-rays detector. Beam currents have been measured by a system of two Faraday cups. Corrections for target thickness effects have been applied to the… ▽ More

    Submitted 16 August, 2017; originally announced August 2017.

    Comments: 13 pages, 2 Tables, 4 Figures. Submitted to NIM B

    Journal ref: Nucl. Instrum. Methods B 410, 102 (2017)

  2. A procedure to correct for target thickness effects in heavy-ion PIXE at MeV energies

    Authors: A. Zucchiatti, P. Galan, J. E. Prieto

    Abstract: We describe a novel procedure for the calculation of correction factors for taking into account the effect of target thickness to be applied to the determination of cross sections of X-ray emission induced by heavy ions at MeV energies. We discuss the origin of the correction and describe the calculations, based on simple polynomial fits of both the theoretical cross sections and the ion energy lo… ▽ More

    Submitted 17 May, 2017; originally announced May 2017.

    Comments: 11 pages, 2 Tables, 4 Figures. Submitted to NIM B

    Journal ref: Nucl. Instrum. Methods B 407, 1 (2017)

  3. Cross sections of X-ray production induced by C and Si ions with energies up to 1 MeV/u on Ti, Fe, Zn, Nb, Ru and Ta

    Authors: J. E. Prieto, A. Zucchiatti, P. Galán, P. Prieto

    Abstract: X-ray production differential cross sections induced by C and Si ions with energies from 1 MeV/u down to 0.25 MeV/u, produced by the CMAM 5 MV tandem accelerator, have been measured for thin targets of Ti, Fe, Zn, Nb, Ru and Ta in a direct way. X-rays have been detected by a fully characterized silicon drift diode and beam currents have been measured by a system of two Faraday cups. Measured cross… ▽ More

    Submitted 28 November, 2016; originally announced November 2016.

    Comments: 11 pages, 2 tables, 7 figures. Contribution to the 12th. European Conference on Accelerators in Applied Research and Technology (ECAART 12) held in Jyväskylä, Finland, 3-8 July 2016

    Journal ref: Nucl. Instrum. Methods B 406, 167 (2017)

  4. arXiv:1111.5731  [pdf, other

    physics.ins-det nucl-ex

    AGATA - Advanced Gamma Tracking Array

    Authors: S. Akkoyun, A. Algora, B. Alikhani, F. Ameil, G. de Angelis, L. Arnold, A. Astier, A. Ataç, Y. Aubert, C. Aufranc, A. Austin, S. Aydin, F. Azaiez, S. Badoer, D. L. Balabanski, D. Barrientos, G. Baulieu, R. Baumann, D. Bazzacco, F. A. Beck, T. Beck, P. Bednarczyk, M. Bellato, M. A. Bentley, G. Benzoni , et al. (329 additional authors not shown)

    Abstract: The Advanced GAmma Tracking Array (AGATA) is a European project to develop and operate the next generation gamma-ray spectrometer. AGATA is based on the technique of gamma-ray energy tracking in electrically segmented high-purity germanium crystals. This technique requires the accurate determination of the energy, time and position of every interaction as a gamma ray deposits its energy within the… ▽ More

    Submitted 17 September, 2012; v1 submitted 24 November, 2011; originally announced November 2011.

    Comments: This version contains a correction of a ty** error in the caption of Fig. 2. The DOI to the article published in Nucl. Instr. Meth A was also added

  5. The GRAAL high resolution BGO calorimeter and its energy calibration and monitoring system

    Authors: F. Ghio, B. Girolami, M. Capogni, L. Casano, L. Ciciani, A. D'Angelo, R. Di Salvo, L. Hu, D. Moricciani, L. Nicoletti, G. Nobili, C. Schaerf, P. Levi Sandri, M. Castoldi, A. Zucchiatti, V. Bellini

    Abstract: We describe the electromagnetic calorimeter built for the GRAAL apparatus at the ESRF. Its monitoring system is presented in detail. Results from tests and the performance obtained during the first GRAAL experiments are given. The energy calibration accuracy and stability reached is a small fraction of the intrinsic detector resolution.

    Submitted 19 September, 1997; originally announced September 1997.

    Comments: 19 pages, 14 figures, submitted to Nuclear Instruments and Methods

    Report number: LNF-97/030(P)

    Journal ref: Nucl.Instrum.Meth. A404 (1998) 71-86