-
Cross sections of X-ray production induced on Ti, Fe, Zn, Nb and Ta by O, Cl, Cu and Br ions with energies between 4 MeV and 40 MeV
Authors:
J. E. Prieto,
P. Galan,
A. Zucchiatti
Abstract:
Differential cross section of X-ray production induced by O, Cl, Cu and Br ions with energies between 4 MeV and 40 MeV have been measured for thin targets of Ti, Fe, Zn, Nb and Ta in a direct way. A fully characterized silicon drift diode was used as X-rays detector. Beam currents have been measured by a system of two Faraday cups. Corrections for target thickness effects have been applied to the…
▽ More
Differential cross section of X-ray production induced by O, Cl, Cu and Br ions with energies between 4 MeV and 40 MeV have been measured for thin targets of Ti, Fe, Zn, Nb and Ta in a direct way. A fully characterized silicon drift diode was used as X-rays detector. Beam currents have been measured by a system of two Faraday cups. Corrections for target thickness effects have been applied to the raw data. Experimental cross sections are compared both with theory and with previously published results. Experimental results from other authors are in reasonable agreement with ours over a wide energy range. Theory produces consistent results in the case of oxygen ions but gives cross sections even orders of magnitude below the experimental ones for heavier ions (ECPSSR-UA) or contrasting results (PWBA) depending on the ion-target combination.
△ Less
Submitted 16 August, 2017;
originally announced August 2017.
-
A procedure to correct for target thickness effects in heavy-ion PIXE at MeV energies
Authors:
A. Zucchiatti,
P. Galan,
J. E. Prieto
Abstract:
We describe a novel procedure for the calculation of correction factors for taking into account the effect of target thickness to be applied to the determination of cross sections of X-ray emission induced by heavy ions at MeV energies. We discuss the origin of the correction and describe the calculations, based on simple polynomial fits of both the theoretical cross sections and the ion energy lo…
▽ More
We describe a novel procedure for the calculation of correction factors for taking into account the effect of target thickness to be applied to the determination of cross sections of X-ray emission induced by heavy ions at MeV energies. We discuss the origin of the correction and describe the calculations, based on simple polynomial fits of both the theoretical cross sections and the ion energy losses. The procedure can be easily implemented. We show several examples for a set of targets specifically produced for cross section measurements and for various combinations of ion type and energy.
△ Less
Submitted 17 May, 2017;
originally announced May 2017.
-
Cross sections of X-ray production induced by C and Si ions with energies up to 1 MeV/u on Ti, Fe, Zn, Nb, Ru and Ta
Authors:
J. E. Prieto,
A. Zucchiatti,
P. Galán,
P. Prieto
Abstract:
X-ray production differential cross sections induced by C and Si ions with energies from 1 MeV/u down to 0.25 MeV/u, produced by the CMAM 5 MV tandem accelerator, have been measured for thin targets of Ti, Fe, Zn, Nb, Ru and Ta in a direct way. X-rays have been detected by a fully characterized silicon drift diode and beam currents have been measured by a system of two Faraday cups. Measured cross…
▽ More
X-ray production differential cross sections induced by C and Si ions with energies from 1 MeV/u down to 0.25 MeV/u, produced by the CMAM 5 MV tandem accelerator, have been measured for thin targets of Ti, Fe, Zn, Nb, Ru and Ta in a direct way. X-rays have been detected by a fully characterized silicon drift diode and beam currents have been measured by a system of two Faraday cups. Measured cross sections agree in general with previously published results. The ECPSSR theory with the united atoms correction gives absolute values close to the experimental ones for all the studied elements excited by C ions and for Ta, Nb and Ru excited by Si ions. For Ti, Fe and Zn excited by Si, the basic ECPSSR theory gives better agreement, although on absolute values the gap for Ti is still large.
△ Less
Submitted 28 November, 2016;
originally announced November 2016.
-
AGATA - Advanced Gamma Tracking Array
Authors:
S. Akkoyun,
A. Algora,
B. Alikhani,
F. Ameil,
G. de Angelis,
L. Arnold,
A. Astier,
A. Ataç,
Y. Aubert,
C. Aufranc,
A. Austin,
S. Aydin,
F. Azaiez,
S. Badoer,
D. L. Balabanski,
D. Barrientos,
G. Baulieu,
R. Baumann,
D. Bazzacco,
F. A. Beck,
T. Beck,
P. Bednarczyk,
M. Bellato,
M. A. Bentley,
G. Benzoni
, et al. (329 additional authors not shown)
Abstract:
The Advanced GAmma Tracking Array (AGATA) is a European project to develop and operate the next generation gamma-ray spectrometer. AGATA is based on the technique of gamma-ray energy tracking in electrically segmented high-purity germanium crystals. This technique requires the accurate determination of the energy, time and position of every interaction as a gamma ray deposits its energy within the…
▽ More
The Advanced GAmma Tracking Array (AGATA) is a European project to develop and operate the next generation gamma-ray spectrometer. AGATA is based on the technique of gamma-ray energy tracking in electrically segmented high-purity germanium crystals. This technique requires the accurate determination of the energy, time and position of every interaction as a gamma ray deposits its energy within the detector volume. Reconstruction of the full interaction path results in a detector with very high efficiency and excellent spectral response. The realization of gamma-ray tracking and AGATA is a result of many technical advances. These include the development of encapsulated highly-segmented germanium detectors assembled in a triple cluster detector cryostat, an electronics system with fast digital sampling and a data acquisition system to process the data at a high rate. The full characterization of the crystals was measured and compared with detector-response simulations. This enabled pulse-shape analysis algorithms, to extract energy, time and position, to be employed. In addition, tracking algorithms for event reconstruction were developed. The first phase of AGATA is now complete and operational in its first physics campaign. In the future AGATA will be moved between laboratories in Europe and operated in a series of campaigns to take advantage of the different beams and facilities available to maximize its science output. The paper reviews all the achievements made in the AGATA project including all the necessary infrastructure to operate and support the spectrometer.
△ Less
Submitted 17 September, 2012; v1 submitted 24 November, 2011;
originally announced November 2011.
-
The GRAAL high resolution BGO calorimeter and its energy calibration and monitoring system
Authors:
F. Ghio,
B. Girolami,
M. Capogni,
L. Casano,
L. Ciciani,
A. D'Angelo,
R. Di Salvo,
L. Hu,
D. Moricciani,
L. Nicoletti,
G. Nobili,
C. Schaerf,
P. Levi Sandri,
M. Castoldi,
A. Zucchiatti,
V. Bellini
Abstract:
We describe the electromagnetic calorimeter built for the GRAAL apparatus at the ESRF. Its monitoring system is presented in detail. Results from tests and the performance obtained during the first GRAAL experiments are given. The energy calibration accuracy and stability reached is a small fraction of the intrinsic detector resolution.
We describe the electromagnetic calorimeter built for the GRAAL apparatus at the ESRF. Its monitoring system is presented in detail. Results from tests and the performance obtained during the first GRAAL experiments are given. The energy calibration accuracy and stability reached is a small fraction of the intrinsic detector resolution.
△ Less
Submitted 19 September, 1997;
originally announced September 1997.