-
Neural force functional for non-equilibrium many-body colloidal systems
Authors:
Toni Zimmerman,
Florian Sammüller,
Sophie Hermann,
Matthias Schmidt,
Daniel de las Heras
Abstract:
We combine power functional theory and machine learning to study non-equilibrium overdamped many-body systems of colloidal particles at the level of one-body fields. We first sample in steady state the one-body fields relevant for the dynamics from computer simulations of Brownian particles under the influence of randomly generated external fields. A neural network is then trained with this data t…
▽ More
We combine power functional theory and machine learning to study non-equilibrium overdamped many-body systems of colloidal particles at the level of one-body fields. We first sample in steady state the one-body fields relevant for the dynamics from computer simulations of Brownian particles under the influence of randomly generated external fields. A neural network is then trained with this data to represent locally in space the formally exact functional map** from the one-body density and velocity profiles to the one-body internal force field. The trained network is used to analyse the non-equilibrium superadiabatic force field and the transport coefficients such as shear and bulk viscosities. Due to the local learning approach, the network can be applied to systems much larger than the original simulation box in which the one-body fields are sampled. Complemented with the exact non-equilibrium one-body force balance equation and a continuity equation, the network yields viable predictions of the dynamics in time-dependent situations. Even though training is based on steady states only, the predicted dynamics is in good agreement with simulation results. A neural dynamical density functional theory can be straightforwardly implemented as a limiting case in which the internal force field is that of an equilibrium system. The framework is general and directly applicable to other many-body systems of interacting particles following Brownian dynamics.
△ Less
Submitted 5 June, 2024;
originally announced June 2024.
-
Design and performance of the Fermilab Constant Fraction Discriminator ASIC
Authors:
Si Xie,
Artur Apresyan,
Ryan Heller,
Christopher Madrid,
Irene Dutta,
Aram Hayrapetyan,
Sergey Los,
Cristian Pena,
Tom Zimmerman
Abstract:
We present the design and performance characterization results of the novel Fermilab Constant Fraction Discriminator ASIC (FCFD) developed to readout low gain avalanche detector (LGAD) signals by directly using a constant fraction discriminator (CFD) to measure signal arrival time. Silicon detectors with time resolutions less than 30 ps will play a critical role in future collider experiments, and…
▽ More
We present the design and performance characterization results of the novel Fermilab Constant Fraction Discriminator ASIC (FCFD) developed to readout low gain avalanche detector (LGAD) signals by directly using a constant fraction discriminator (CFD) to measure signal arrival time. Silicon detectors with time resolutions less than 30 ps will play a critical role in future collider experiments, and LGADs have been demonstrated to provide the required time resolution and radiation tolerance for many such applications. The FCFD has a specially designed discriminator that is robust against amplitude variations of the signal from the LGAD that normally requires an additional correction step when using a traditional leading edge discriminator based measurement. The application of the CFD directly in the ASIC promises to be more reliable and reduces the complication of timing detectors during their operation. We will present a summary of the measured performance of the FCFD for input signals generated by internal charge injection, LGAD signals from an infrared laser, and LGAD signals from minimum-ionizing particles. The mean time response for a wide range of LGAD signal amplitudes has been measured to vary no more than 15 ps, orders of magnitude more stable than an uncorrected leading edge discriminator based measurement, and effectively removes the need for any additional time-walk correction. The measured contribution to the time resolution from the FCFD ASIC is also found to be 10 ps for signals with charge above 20 fC.
△ Less
Submitted 12 June, 2023;
originally announced June 2023.
-
A Cryogenic Readout IC with 100 KSPS in-Pixel ADC for Skipper CCD-in-CMOS Sensors
Authors:
Adam Quinn,
Manuel B. Valentin,
Thomas Zimmerman,
Davide Braga,
Seda Memik,
Farah Fahim
Abstract:
The Skipper CCD-in-CMOS Parallel Read-Out Circuit (SPROCKET) is a mixed-signal front-end design for the readout of Skipper CCD-in-CMOS image sensors. SPROCKET is fabricated in a 65 nm CMOS process and each pixel occupies a 50$μ$m $\times$ 50$μ$m footprint. SPROCKET is intended to be heterogeneously integrated with a Skipper-in-CMOS sensor array, such that one readout pixel is connected to a multip…
▽ More
The Skipper CCD-in-CMOS Parallel Read-Out Circuit (SPROCKET) is a mixed-signal front-end design for the readout of Skipper CCD-in-CMOS image sensors. SPROCKET is fabricated in a 65 nm CMOS process and each pixel occupies a 50$μ$m $\times$ 50$μ$m footprint. SPROCKET is intended to be heterogeneously integrated with a Skipper-in-CMOS sensor array, such that one readout pixel is connected to a multiplexed array of nine Skipper-in-CMOS pixels to enable massively parallel readout. The front-end includes a variable gain preamplifier, a correlated double sampling circuit, and a 10-bit serial successive approximation register (SAR) ADC. The circuit achieves a sample rate of 100 ksps with 0.48 $\mathrm{e^-_{rms}}$ equivalent noise at the input to the ADC. SPROCKET achieves a maximum dynamic range of 9,000 $e^-$ at the lowest gain setting (or 900 $e^-$ at the lowest noise setting). The circuit operates at 100 Kelvin with a power consumption of 40 $μW$ per pixel. A SPROCKET test chip was submitted in September 2022, and test results will be presented at the conference.
△ Less
Submitted 7 February, 2023;
originally announced February 2023.
-
Electronics for Fast Timing
Authors:
D. Braga,
G. Carini,
G. Deptuch,
A. Dragone,
F. Fahim,
K. Flood,
G. Giacomini,
D. Gorni,
R. Lipton,
B. Markovic,
S. Mazza,
S. Miryala,
P. Rubinov,
G. Saffier-Ewing,
H. Sadrozinski,
A. Schwartzman,
A. Seiden,
Q. Sun,
T. Zimmerman
Abstract:
Picosecond-level timing will be an important component of the next generation of particle physics detectors. The ability to add a 4$^{th}$ dimension to our measurements will help address the increasing complexity of events at hadron colliders and provide new tools for precise tracking and calorimetry for all experiments. Detectors are described in detail on other whitepapers. In this note, we addr…
▽ More
Picosecond-level timing will be an important component of the next generation of particle physics detectors. The ability to add a 4$^{th}$ dimension to our measurements will help address the increasing complexity of events at hadron colliders and provide new tools for precise tracking and calorimetry for all experiments. Detectors are described in detail on other whitepapers. In this note, we address challenges in electronics design for the new generations of fast timing detectors
△ Less
Submitted 31 March, 2022;
originally announced April 2022.
-
Development of the FASPAX IC for a high burst rate X-ray imager with very high dynamic range (${10^5}$) capability in small pixels
Authors:
Tom Zimmerman,
Sachin Junnarkar
Abstract:
The technique of current splitting is presented as part of an integrated circuit development for an X-ray imager. This method enables integration of charge signals of unprecedented magnitude in small pixels, achieving a dynamic range of ${10^5}$. Results from two front end prototypes are given and a final optimized design is proposed.
The technique of current splitting is presented as part of an integrated circuit development for an X-ray imager. This method enables integration of charge signals of unprecedented magnitude in small pixels, achieving a dynamic range of ${10^5}$. Results from two front end prototypes are given and a final optimized design is proposed.
△ Less
Submitted 19 April, 2019;
originally announced April 2019.
-
Optimizing floating guard ring designs for FASPAX N-in-P silicon sensors
Authors:
Kyung-Wook Shin,
Robert Bradford,
Ronald Lipton,
Gregory Deptuch,
Farah Fahim,
Tim Madden,
Tom Zimmerman
Abstract:
FASPAX (Fermi-Argonne Semiconducting Pixel Array X-ray detector) is being developed as a fast integrating area detector with wide dynamic range for time resolved applications at the upgraded Advanced Photon Source (APS.) A burst mode detector with intended $\mbox{13 $MHz$}$ image rate, FASPAX will also incorporate a novel integration circuit to achieve wide dynamic range, from single photon sensit…
▽ More
FASPAX (Fermi-Argonne Semiconducting Pixel Array X-ray detector) is being developed as a fast integrating area detector with wide dynamic range for time resolved applications at the upgraded Advanced Photon Source (APS.) A burst mode detector with intended $\mbox{13 $MHz$}$ image rate, FASPAX will also incorporate a novel integration circuit to achieve wide dynamic range, from single photon sensitivity to $10^{\text{5}}$ x-rays/pixel/pulse. To achieve these ambitious goals, a novel silicon sensor design is required. This paper will detail early design of the FASPAX sensor. Results from TCAD optimization studies, and characterization of prototype sensors will be presented.
△ Less
Submitted 13 September, 2016;
originally announced September 2016.
-
The PHENIX Forward Silicon Vertex Detector
Authors:
C. Aidala,
L. Anaya,
E. Anderssen,
A. Bambaugh,
A. Barron,
J. G. Boissevain,
J. Bok,
S. Boose,
M. L. Brooks,
S. Butsyk,
M. Cepeda,
P. Chacon,
S. Chacon,
L. Chavez,
T. Cote,
C. D'Agostino,
A. Datta,
K. DeBlasio,
L. DelMonte,
E. J. Desmond,
J. M. Durham,
D. Fields,
M. Finger,
C. Gingu,
B. Gonzales
, et al. (60 additional authors not shown)
Abstract:
A new silicon detector has been developed to provide the PHENIX experiment with precise charged particle tracking at forward and backward rapidity. The Forward Silicon Vertex Tracker (FVTX) was installed in PHENIX prior to the 2012 run period of the Relativistic Heavy Ion Collider (RHIC). The FVTX is composed of two annular endcaps, each with four stations of silicon mini-strip sensors, covering a…
▽ More
A new silicon detector has been developed to provide the PHENIX experiment with precise charged particle tracking at forward and backward rapidity. The Forward Silicon Vertex Tracker (FVTX) was installed in PHENIX prior to the 2012 run period of the Relativistic Heavy Ion Collider (RHIC). The FVTX is composed of two annular endcaps, each with four stations of silicon mini-strip sensors, covering a rapidity range of $1.2<|η|<2.2$ that closely matches the two existing PHENIX muon arms. Each station consists of 48 individual silicon sensors, each of which contains two columns of mini-strips with 75 $μ$m pitch in the radial direction and lengths in the $φ$ direction varying from 3.4 mm at the inner radius to 11.5 mm at the outer radius. The FVTX has approximately 0.54 million strips in each endcap. These are read out with FPHX chips, developed in collaboration with Fermilab, which are wire bonded directly to the mini-strips. The maximum strip occupancy reached in central Au-Au collisions is approximately 2.8%. The precision tracking provided by this device makes the identification of muons from secondary vertices away from the primary event vertex possible. The expected distance of closest approach (DCA) resolution of 200 $μ$m or better for particles with a transverse momentum of 5 GeV/$c$ will allow identification of muons from relatively long-lived particles, such as $D$ and $B$ mesons, through their broader DCA distributions.
△ Less
Submitted 14 February, 2014; v1 submitted 14 November, 2013;
originally announced November 2013.
-
The D0 Silicon Microstrip Tracker
Authors:
S. N. Ahmed,
R. Angstadt,
M. Aoki,
B. Åsman,
S. Austin,
L. Bagby,
E. Barberis,
P. Baringer,
A. Bean,
A. Bischoff,
F. Blekman,
T. A. Bolton,
C. Boswell,
M. Bowden,
F. Browning,
D. Buchholz,
S. Burdin,
D. Butler,
H. Cease,
S. Choi,
A. R. Clark,
J. Clutter,
A. Cooper,
W. E. Cooper,
M. Corcoran
, et al. (109 additional authors not shown)
Abstract:
This paper describes the mechanical design, the readout chain, the production, testing and the installation of the Silicon Microstrip Tracker of the D0 experiment at the Fermilab Tevatron collider. In addition, description of the performance of the detector during the experiment data collection between 2001 and 2010 is provided.
This paper describes the mechanical design, the readout chain, the production, testing and the installation of the Silicon Microstrip Tracker of the D0 experiment at the Fermilab Tevatron collider. In addition, description of the performance of the detector during the experiment data collection between 2001 and 2010 is provided.
△ Less
Submitted 5 May, 2010;
originally announced May 2010.