-
The GlueX Beamline and Detector
Authors:
S. Adhikari,
C. S. Akondi,
H. Al Ghoul,
A. Ali,
M. Amaryan,
E. G. Anassontzis,
A. Austregesilo,
F. Barbosa,
J. Barlow,
A. Barnes,
E. Barriga,
R. Barsotti,
T. D. Beattie,
J. Benesch,
V. V. Berdnikov,
G. Biallas,
T. Black,
W. Boeglin,
P. Brindza,
W. J. Briscoe,
T. Britton,
J. Brock,
W. K. Brooks,
B. E. Cannon,
C. Carlin
, et al. (165 additional authors not shown)
Abstract:
The GlueX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons are tagged using a scintillator hodoscope and a scintillating fiber array. The photon flux is determined using a pair spectrometer, while the linear polarization of the photon beam is determined using a polarimeter based…
▽ More
The GlueX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons are tagged using a scintillator hodoscope and a scintillating fiber array. The photon flux is determined using a pair spectrometer, while the linear polarization of the photon beam is determined using a polarimeter based on triplet photoproduction. Charged-particle tracks from interactions in the central target are analyzed in a solenoidal field using a central straw-tube drift chamber and six packages of planar chambers with cathode strips and drift wires. Electromagnetic showers are reconstructed in a cylindrical scintillating fiber calorimeter inside the magnet and a lead-glass array downstream. Charged particle identification is achieved by measuring energy loss in the wire chambers and using the flight time of particles between the target and detectors outside the magnet. The signals from all detectors are recorded with flash ADCs and/or pipeline TDCs into memories allowing trigger decisions with a latency of 3.3 $μ$s. The detector operates routinely at trigger rates of 40 kHz and data rates of 600 megabytes per second. We describe the photon beam, the GlueX detector components, electronics, data-acquisition and monitoring systems, and the performance of the experiment during the first three years of operation.
△ Less
Submitted 26 October, 2020; v1 submitted 28 May, 2020;
originally announced May 2020.
-
AI-optimized detector design for the future Electron-Ion Collider: the dual-radiator RICH case
Authors:
E. Cisbani,
A. Del Dotto,
C. Fanelli,
M. Williams,
M. Alfred,
F. Barbosa,
L. Barion,
V. Berdnikov,
W. Brooks,
T. Cao,
M. Contalbrigo,
S. Danagoulian,
A. Datta,
M. Demarteau,
A. Denisov,
M. Diefenthaler,
A. Durum,
D. Fields,
Y. Furletova,
C. Gleason,
M. Grosse-Perdekamp,
M. Hattawy,
X. He,
H. van Hecke,
D. Higinbotham
, et al. (22 additional authors not shown)
Abstract:
Advanced detector R&D requires performing computationally intensive and detailed simulations as part of the detector-design optimization process. We propose a general approach to this process based on Bayesian optimization and machine learning that encodes detector requirements. As a case study, we focus on the design of the dual-radiator Ring Imaging Cherenkov (dRICH) detector under development a…
▽ More
Advanced detector R&D requires performing computationally intensive and detailed simulations as part of the detector-design optimization process. We propose a general approach to this process based on Bayesian optimization and machine learning that encodes detector requirements. As a case study, we focus on the design of the dual-radiator Ring Imaging Cherenkov (dRICH) detector under development as part of the particle-identification system at the future Electron-Ion Collider (EIC). The EIC is a US-led frontier accelerator project for nuclear physics, which has been proposed to further explore the structure and interactions of nuclear matter at the scale of sea quarks and gluons. We show that the detector design obtained with our automated and highly parallelized framework outperforms the baseline dRICH design within the assumptions of the current model. Our approach can be applied to any detector R&D, provided that realistic simulations are available.
△ Less
Submitted 6 June, 2020; v1 submitted 13 November, 2019;
originally announced November 2019.
-
The Central Drift Chamber for GlueX
Authors:
N. S. Jarvis,
C. A. Meyer,
B. Zihlmann,
M. Staib,
A. Austregesilo,
F. Barbosa,
C. Dickover,
V. Razmyslovich,
S. Taylor,
Y. Van Haarlem,
G. Visser,
T. Whitlatch
Abstract:
The Central Drift Chamber is a straw-tube wire chamber of cylindrical structure located surrounding the target inside the bore of the GlueX spectrometer solenoid. Its purpose is to detect and track charged particles with momenta as low as 0.25 GeV/c as well as to identify low-momentum protons via energy loss. The construction of the detector is described and its operation and calibration are discu…
▽ More
The Central Drift Chamber is a straw-tube wire chamber of cylindrical structure located surrounding the target inside the bore of the GlueX spectrometer solenoid. Its purpose is to detect and track charged particles with momenta as low as 0.25 GeV/c as well as to identify low-momentum protons via energy loss. The construction of the detector is described and its operation and calibration are discussed in detail. The design goal of 150 microns in position resolution has been reached.
△ Less
Submitted 27 February, 2020; v1 submitted 16 October, 2019;
originally announced October 2019.
-
The GlueX Start Counter Detector
Authors:
Eric Pooser,
Fernando Barbosa,
Werner Boeglin,
Charles Hutton,
Mark Ito,
Mahmoud Kamel,
Puneet Khetarpal,
Anthony Llodra,
Joseph Sandoval,
Simon Taylor,
Timothy Whitlatch,
Stephanie Worthington,
Carlos Yero,
Benedikt Zihlmann
Abstract:
The design, simulation, fabrication, calibration, and performance of the GlueX Start Counter detector is described. The Start Counter was designed to operate at integrated rates of up to 9 MHz with a timing resolution in the range of 500 to 825 ps (FWHM). The Start Counter provides excellent solid angle coverage, a high degree of segmentation for background rejection, and can be utilized in the le…
▽ More
The design, simulation, fabrication, calibration, and performance of the GlueX Start Counter detector is described. The Start Counter was designed to operate at integrated rates of up to 9 MHz with a timing resolution in the range of 500 to 825 ps (FWHM). The Start Counter provides excellent solid angle coverage, a high degree of segmentation for background rejection, and can be utilized in the level 1 trigger for the experiment. It consists of a cylindrical array of 30 thin scintillators with pointed ends that bend towards the beam line at the downstream end. Magnetic field insensitive silicon photomultiplier detectors were used as the light sensors.
△ Less
Submitted 9 January, 2019;
originally announced January 2019.
-
Construction and Performance of the Barrel Electromagnetic Calorimeter for the GlueX Experiment
Authors:
Tegan Beattie,
Ahmed Foda,
Colleen Henschel,
S Katsaganis,
Shaun Krueger,
George Lolos,
Zisis Papandreou,
E. L. Plummer,
Irina Semenova,
Andrei Semenov,
Fernando Barbosa,
Eugene Chudakov,
Mark Dalton,
David Lawrence,
Yi Qiang,
Nicholas Sandoval,
Elton Smith,
Christopher Stanislav,
Justin Stevens,
Simon Taylor,
Timothy Whitlatch,
Benedikt Zihlmann,
William Levine,
William McGinley,
Curtis Meyer
, et al. (14 additional authors not shown)
Abstract:
The barrel calorimeter is part of the new spectrometer installed in Hall D at Jefferson Lab for the GlueX experiment. The calorimeter was installed in 2013, commissioned in 2014 and has been operating routinely since early 2015. The detector configuration, associated Monte Carlo simulations, calibration and operational performance are described herein. The calorimeter records the time and energy d…
▽ More
The barrel calorimeter is part of the new spectrometer installed in Hall D at Jefferson Lab for the GlueX experiment. The calorimeter was installed in 2013, commissioned in 2014 and has been operating routinely since early 2015. The detector configuration, associated Monte Carlo simulations, calibration and operational performance are described herein. The calorimeter records the time and energy deposited by charged and neutral particles created by a multi-GeV photon beam. It is constructed as a lead and scintillating-fiber calorimeter and read out with 3840 large-area silicon photomultiplier arrays. Particles im**e on the detector over a wide range of angles, from normal incidence at 90 degrees down to 11.5 degrees, which defines a geometry that is fairly unique among calorimeters. The response of the calorimeter has been measured during a running experiment and performs as expected for electromagnetic showers below 2.5 GeV. We characterize the performance of the BCAL using the energy resolution integrated over typical angular distributions for $π^0$ and $η$ production of $σ_E/E$=5.2\%/$\sqrt{E(\rm{GeV})} \oplus$ 3.6\% and a timing resolution of $σ$\,=\,150\,ps at 1\,GeV.
△ Less
Submitted 20 April, 2018; v1 submitted 9 January, 2018;
originally announced January 2018.
-
First Results from The GlueX Experiment
Authors:
The GlueX Collaboration,
H. Al Ghoul,
E. G. Anassontzis,
F. Barbosa,
A. Barnes,
T. D. Beattie,
D. W. Bennett,
V. V. Berdnikov,
T. Black,
W. Boeglin,
W. K. Brooks,
B. Cannon,
O. Chernyshov,
E. Chudakov,
V. Crede,
M. M. Dalton,
A. Deur,
S. Dobbs,
A. Dolgolenko,
M. Dugger,
H. Egiyan,
P. Eugenio,
A. M. Foda,
J. Frye,
S. Furletov
, et al. (86 additional authors not shown)
Abstract:
The GlueX experiment at Jefferson Lab ran with its first commissioning beam in late 2014 and the spring of 2015. Data were collected on both plastic and liquid hydrogen targets, and much of the detector has been commissioned. All of the detector systems are now performing at or near design specifications and events are being fully reconstructed, including exclusive production of $π^{0}$, $η$ and…
▽ More
The GlueX experiment at Jefferson Lab ran with its first commissioning beam in late 2014 and the spring of 2015. Data were collected on both plastic and liquid hydrogen targets, and much of the detector has been commissioned. All of the detector systems are now performing at or near design specifications and events are being fully reconstructed, including exclusive production of $π^{0}$, $η$ and $ω$ mesons. Linearly-polarized photons were successfully produced through coherent bremsstrahlung and polarization transfer to the $ρ$ has been observed.
△ Less
Submitted 14 January, 2016; v1 submitted 11 December, 2015;
originally announced December 2015.
-
A study of decays to strange final states with GlueX in Hall D using components of the BaBar DIRC
Authors:
The GlueX Collaboration,
M. Dugger,
B. Ritchie,
I. Senderovich,
E. Anassontzis,
P. Ioannou,
C. Kourkoumeli,
G. Vasileiadis,
G. Voulgaris,
N. Jarvis,
W. Levine,
P. Mattione,
W. McGinley,
C. A. Meyer,
R. Schumacher,
M. Staib,
F. Klein,
D. Sober,
N. Sparks,
N. Walford,
D. Doughty,
A. Barnes,
R. Jones,
J. McIntyre,
F. Mokaya
, et al. (82 additional authors not shown)
Abstract:
We propose to enhance the kaon identification capabilities of the GlueX detector by constructing an FDIRC (Focusing Detection of Internally Reflected Cherenkov) detector utilizing the decommissioned BaBar DIRC components. The GlueX FDIRC would significantly enhance the GlueX physics program by allowing one to search for and study hybrid mesons decaying into kaon final states. Such systematic studi…
▽ More
We propose to enhance the kaon identification capabilities of the GlueX detector by constructing an FDIRC (Focusing Detection of Internally Reflected Cherenkov) detector utilizing the decommissioned BaBar DIRC components. The GlueX FDIRC would significantly enhance the GlueX physics program by allowing one to search for and study hybrid mesons decaying into kaon final states. Such systematic studies of kaon final states are essential for inferring the quark flavor content of hybrid and conventional mesons. The GlueX FDIRC would reuse one-third of the synthetic fused silica bars that were utilized in the BaBar DIRC. A new focussing photon camera, read out with large area photodetectors, would be developed. We propose operating the enhanced GlueX detector in Hall D for a total of 220 days at an average intensity of 5x10^7 γ/s, a program that was conditionally approved by PAC39
△ Less
Submitted 1 August, 2014;
originally announced August 2014.
-
The HERMES Recoil Detector
Authors:
A. Airapetian,
E. C. Aschenauer,
S. Belostotski,
A. Borissov,
A. Borisenko,
J. Bowles,
I. Brodski,
V. Bryzgalov,
J. Burns,
G. P. Capitani,
V. Carassiti,
G. Ciullo,
A. Clarkson,
M. Contalbrigo,
R. De Leo,
E. De Sanctis,
M. Diefenthaler,
P. Di Nezza,
M. Düren,
M. Ehrenfried,
H. Guler,
I. M. Gregor,
M. Hartig,
G. Hill,
M. Hoek
, et al. (58 additional authors not shown)
Abstract:
For the final running period of HERA, a recoil detector was installed at the HERMES experiment to improve measurements of hard exclusive processes in charged-lepton nucleon scattering. Here, deeply virtual Compton scattering is of particular interest as this process provides constraints on generalised parton distributions that give access to the total angular momenta of quarks within the nucleon.…
▽ More
For the final running period of HERA, a recoil detector was installed at the HERMES experiment to improve measurements of hard exclusive processes in charged-lepton nucleon scattering. Here, deeply virtual Compton scattering is of particular interest as this process provides constraints on generalised parton distributions that give access to the total angular momenta of quarks within the nucleon. The HERMES recoil detector was designed to improve the selection of exclusive events by a direct measurement of the four-momentum of the recoiling particle. It consisted of three components: two layers of double-sided silicon strip sensors inside the HERA beam vacuum, a two-barrel scintillating fibre tracker, and a photon detector. All sub-detectors were located inside a solenoidal magnetic field with an integrated field strength of 1 T. The recoil detector was installed in late 2005. After the commissioning of all components was finished in September 2006, it operated stably until the end of data taking at HERA end of June 2007. The present paper gives a brief overview of the physics processes of interest and the general detector design. The recoil detector components, their calibration, the momentum reconstruction of charged particles, and the event selection are described in detail. The paper closes with a summary of the performance of the detection system.
△ Less
Submitted 6 May, 2013; v1 submitted 25 February, 2013;
originally announced February 2013.
-
The GlueX Central Drift Chamber: Design and Performance
Authors:
Y. Van Haarlem,
C. A. Meyer,
F. Barbosa,
B. Dey,
D. Lawrence,
V. Razmyslovich,
E. Smith,
G. Visser,
T. Whitlatch,
G. Wilkin,
B. Zihlmann
Abstract:
Tests and studies concerning the design and performance of the GlueX Central Drift
Chamber (CDC) are presented. A full-scale prototype was built to test and steer the mechanical and electronic design. Small scale prototypes were constructed to test for sagging and to do timing and resolution studies of the detector. These studies were used to choose the gas mixture and to program a Monte Carlo si…
▽ More
Tests and studies concerning the design and performance of the GlueX Central Drift
Chamber (CDC) are presented. A full-scale prototype was built to test and steer the mechanical and electronic design. Small scale prototypes were constructed to test for sagging and to do timing and resolution studies of the detector. These studies were used to choose the gas mixture and to program a Monte Carlo simulation that can predict the detector response in an external magnetic field. Particle identification and charge division possibilities were also investigated.
△ Less
Submitted 21 April, 2010;
originally announced April 2010.