The Lobster Eye Imager for Astronomy Onboard the SATech-01 Satellite
Authors:
Z. X. Ling,
X. J. Sun,
C. Zhang,
S. L. Sun,
G. **,
S. N. Zhang,
X. F. Zhang,
J. B. Chang,
F. S. Chen,
Y. F. Chen,
Z. W. Cheng,
W. Fu,
Y. X. Han,
H. Li,
J. F. Li,
Y. Li,
Z. D. Li,
P. R. Liu,
Y. H. Lv,
X. H. Ma,
Y. J. Tang,
C. B. Wang,
R. J. Xie,
Y. L. Xue,
A. L. Yan
, et al. (101 additional authors not shown)
Abstract:
The Lobster Eye Imager for Astronomy (LEIA), a pathfinder of the Wide-field X-ray Telescope of the Einstein Probe (EP) mission, was successfully launched onboard the SATech-01 satellite of the Chinese Academy of Sciences on 27 July 2022. In this paper, we introduce the design and on-ground test results of the LEIA instrument. Using state-of-the-art Micro-Pore Optics (MPO), a wide field-of-view (Fo…
▽ More
The Lobster Eye Imager for Astronomy (LEIA), a pathfinder of the Wide-field X-ray Telescope of the Einstein Probe (EP) mission, was successfully launched onboard the SATech-01 satellite of the Chinese Academy of Sciences on 27 July 2022. In this paper, we introduce the design and on-ground test results of the LEIA instrument. Using state-of-the-art Micro-Pore Optics (MPO), a wide field-of-view (FoV) of 346 square degrees (18.6 degrees * 18.6 degrees) of the X-ray imager is realized. An optical assembly composed of 36 MPO chips is used to focus incident X-ray photons, and four large-format complementary metal-oxide semiconductor (CMOS) sensors, each of 6 cm * 6 cm, are used as the focal plane detectors. The instrument has an angular resolution of 4 - 8 arcmin (in FWHM) for the central focal spot of the point spread function, and an effective area of 2 - 3 cm2 at 1 keV in essentially all the directions within the field of view. The detection passband is 0.5 - 4 keV in the soft X-rays and the sensitivity is 2 - 3 * 10-11 erg s-1 cm-2 (about 1 mini-Crab) at 1,000 second observation. The total weight of LEIA is 56 kg and the power is 85 W. The satellite, with a design lifetime of 2 years, operates in a Sun-synchronous orbit of 500 km with an orbital period of 95 minutes. LEIA is paving the way for future missions by verifying in flight the technologies of both novel focusing imaging optics and CMOS sensors for X-ray observation, and by optimizing the working setups of the instrumental parameters. In addition, LEIA is able to carry out scientific observations to find new transients and to monitor known sources in the soft X-ray band, albeit limited useful observing time available.
△ Less
Submitted 24 May, 2023;
originally announced May 2023.
-
Extraction of the $^{235}$U and $^{239}$Pu Antineutrino Spectra at Daya Bay
Authors:
Daya Bay collaboration,
D. Adey,
F. P. An,
A. B. Balantekin,
H. R. Band,
M. Bishai,
S. Blyth,
D. Cao,
G. F. Cao,
J. Cao,
J. F. Chang,
Y. Chang,
H. S. Chen,
S. M. Chen,
Y. Chen,
Y. X. Chen,
J. Cheng,
Z. K. Cheng,
J. J. Cherwinka,
M. C. Chu,
A. Chukanov,
J. P. Cummings,
N. Dash,
F. S. Deng,
Y. Y. Ding
, et al. (171 additional authors not shown)
Abstract:
This Letter reports the first extraction of individual antineutrino spectra from $^{235}$U and $^{239}$Pu fission and an improved measurement of the prompt energy spectrum of reactor antineutrinos at Daya Bay. The analysis uses $3.5\times 10^6$ inverse beta-decay candidates in four near antineutrino detectors in 1958 days. The individual antineutrino spectra of the two dominant isotopes, $^{235}$U…
▽ More
This Letter reports the first extraction of individual antineutrino spectra from $^{235}$U and $^{239}$Pu fission and an improved measurement of the prompt energy spectrum of reactor antineutrinos at Daya Bay. The analysis uses $3.5\times 10^6$ inverse beta-decay candidates in four near antineutrino detectors in 1958 days. The individual antineutrino spectra of the two dominant isotopes, $^{235}$U and $^{239}$Pu, are extracted using the evolution of the prompt spectrum as a function of the isotope fission fractions. In the energy window of 4--6~MeV, a 7\% (9\%) excess of events is observed for the $^{235}$U ($^{239}$Pu) spectrum compared with the normalized Huber-Mueller model prediction. The significance of discrepancy is $4.0σ$ for $^{235}$U spectral shape compared with the Huber-Mueller model prediction. The shape of the measured inverse beta-decay prompt energy spectrum disagrees with the prediction of the Huber-Mueller model at $5.3σ$. In the energy range of 4--6~MeV, a maximal local discrepancy of $6.3σ$ is observed.
△ Less
Submitted 16 September, 2019; v1 submitted 16 April, 2019;
originally announced April 2019.
-
A high precision calibration of the nonlinear energy response at Daya Bay
Authors:
Daya Bay collaboration,
D. Adey,
F. P. An,
A. B. Balantekin,
H. R. Band,
M. Bishai,
S. Blyth,
D. Cao,
G. F. Cao,
J. Cao,
J. F. Chang,
Y. Chang,
H. S. Chen,
S. M. Chen,
Y. Chen,
Y. X. Chen,
J. Cheng,
Z. K. Cheng,
J. J. Cherwinka,
M. C. Chu,
A. Chukanov,
J. P. Cummings,
N. Dash,
F. S. Deng,
Y. Y. Ding
, et al. (173 additional authors not shown)
Abstract:
A high precision calibration of the nonlinearity in the energy response of the Daya Bay Reactor Neutrino Experiment's antineutrino detectors is presented in detail. The energy nonlinearity originates from the particle-dependent light yield of the scintillator and charge-dependent electronics response. The nonlinearity model is constrained by $γ$ calibration points from deployed and naturally occur…
▽ More
A high precision calibration of the nonlinearity in the energy response of the Daya Bay Reactor Neutrino Experiment's antineutrino detectors is presented in detail. The energy nonlinearity originates from the particle-dependent light yield of the scintillator and charge-dependent electronics response. The nonlinearity model is constrained by $γ$ calibration points from deployed and naturally occurring radioactive sources, the $β$ spectrum from $^{12}$B decays, and a direct measurement of the electronics nonlinearity with a new flash analog-to-digital converter readout system. Less than 0.5% uncertainty in the energy nonlinearity calibration is achieved for positrons of kinetic energies greater than 1 MeV.
△ Less
Submitted 27 June, 2019; v1 submitted 21 February, 2019;
originally announced February 2019.
-
Measurement of electron antineutrino oscillation with 1958 days of operation at Daya Bay
Authors:
Daya Bay Collaboration,
D. Adey,
F. P. An,
A. B. Balantekin,
H. R. Band,
M. Bishai,
S. Blyth,
D. Cao,
G. F. Cao,
J. Cao,
Y. L. Chan,
J. F. Chang,
Y. Chang,
H. S. Chen,
S. M. Chen,
Y. Chen,
Y. X. Chen,
J. Cheng,
Z. K. Cheng,
J. J. Cherwinka,
M. C. Chu,
A. Chukanov,
J. P. Cummings,
F. S. Deng,
Y. Y. Ding
, et al. (180 additional authors not shown)
Abstract:
We report a measurement of electron antineutrino oscillation from the Daya Bay Reactor Neutrino Experiment with nearly 4 million reactor $\overlineν_{e}$ inverse beta decay candidates observed over 1958 days of data collection. The installation of a Flash-ADC readout system and a special calibration campaign using different source enclosures reduce uncertainties in the absolute energy calibration…
▽ More
We report a measurement of electron antineutrino oscillation from the Daya Bay Reactor Neutrino Experiment with nearly 4 million reactor $\overlineν_{e}$ inverse beta decay candidates observed over 1958 days of data collection. The installation of a Flash-ADC readout system and a special calibration campaign using different source enclosures reduce uncertainties in the absolute energy calibration to less than 0.5% for visible energies larger than 2 MeV. The uncertainty in the cosmogenic $^9$Li and $^8$He background is reduced from 45% to 30% in the near detectors. A detailed investigation of the spent nuclear fuel history improves its uncertainty from 100% to 30%. Analysis of the relative $\overlineν_{e}$ rates and energy spectra among detectors yields
$\sin^{2}2θ_{13} = 0.0856\pm 0.0029$ and $Δm^2_{32}=(2.471^{+0.068}_{-0.070})\times 10^{-3}~\mathrm{eV}^2$ assuming the normal hierarchy, and $Δm^2_{32}=-(2.575^{+0.068}_{-0.070})\times 10^{-3}~\mathrm{eV}^2$ assuming the inverted hierarchy.
△ Less
Submitted 19 December, 2018; v1 submitted 6 September, 2018;
originally announced September 2018.
-
Improved Measurement of the Reactor Antineutrino Flux at Daya Bay
Authors:
Daya Bay Collaboration,
D. Adey,
F. P. An,
A. B. Balantekin,
H. R. Band,
M. Bishai,
S. Blyth,
D. Cao,
G. F. Cao,
J. Cao,
Y. L. Chan,
J. F. Chang,
Y. Chang,
H. S. Chen,
S. M. Chen,
Y. Chen,
Y. X. Chen,
J. Cheng,
Z. K. Cheng,
J. J. Cherwinka,
M. C. Chu,
A. Chukanov,
J. P. Cummings,
F. S. Deng,
Y. Y. Ding
, et al. (178 additional authors not shown)
Abstract:
This work reports a precise measurement of the reactor antineutrino flux using 2.2 million inverse beta decay (IBD) events collected with the Daya Bay near detectors in 1230 days. The dominant uncertainty on the neutron detection efficiency is reduced by 56% with respect to the previous measurement through a comprehensive neutron calibration and detailed data and simulation analysis. The new avera…
▽ More
This work reports a precise measurement of the reactor antineutrino flux using 2.2 million inverse beta decay (IBD) events collected with the Daya Bay near detectors in 1230 days. The dominant uncertainty on the neutron detection efficiency is reduced by 56% with respect to the previous measurement through a comprehensive neutron calibration and detailed data and simulation analysis. The new average IBD yield is determined to be $(5.91\pm0.09)\times10^{-43}~\rm{cm}^2/\rm{fission}$ with total uncertainty improved by 29%. The corresponding mean fission fractions from the four main fission isotopes $^{235}$U, $^{238}$U, $^{239}$Pu, and $^{241}$Pu are 0.564, 0.076, 0.304, and 0.056, respectively. The ratio of measured to predicted antineutrino yield is found to be $0.952\pm0.014\pm0.023$ ($1.001\pm0.015\pm0.027$) for the Huber-Mueller (ILL-Vogel) model, where the first and second uncertainty are experimental and theoretical model uncertainty, respectively. This measurement confirms the discrepancy between the world average of reactor antineutrino flux and the Huber-Mueller model.
△ Less
Submitted 31 August, 2018;
originally announced August 2018.
-
Highly Deformable and Mobile Palladium Nanocrystals as Efficient Carbon Scavengers
Authors:
Peng-Han Lu,
De-Gang Xie,
Bo-Yu Liu,
Fei Ai,
Zhao-Rui Zhang,
Ming-Shang **,
Xiao Feng Zhang,
Evan Ma,
Ju Li,
Zhi-Wei Shan
Abstract:
Fouling of surfaces leads to performance degradation in many energy-intensive industrial processes, but the present solutions are either too complicated to be routinely used or incomplete for eradication. Here we propose and demonstrate that carbon-containing deposits can be catalytically wiped out in an efficient way by roaming palladium nanoparticles with extreme shape flexibility at relatively…
▽ More
Fouling of surfaces leads to performance degradation in many energy-intensive industrial processes, but the present solutions are either too complicated to be routinely used or incomplete for eradication. Here we propose and demonstrate that carbon-containing deposits can be catalytically wiped out in an efficient way by roaming palladium nanoparticles with extreme shape flexibility at relatively low temperatures. Surprisingly, during their dramatic liquid-like migrations, these particles could still maintain crystalline interior and conserve their initial crystal orientations through self-surface diffusion. Moreover, these catalytic particles were even able to become regenerated by other roaming particles after occasionally deactivated by surface coking or multiple-particle sintering. These findings shed light on metabolically driven, "living" nanocrystals, and also open a new avenue for efficient catalysis.
△ Less
Submitted 1 February, 2018;
originally announced February 2018.
-
Instrument Performance and Simulation Verification of the POLAR Detector
Authors:
M. Kole,
Z. H. Li,
N. Produit,
T. Tymieniecka,
J. Zhang,
A. Zwolinska,
T. W. Bao,
T. Bernasconi,
F. Cadoux,
M. Z. Feng,
N. Gauvin,
W. Hajdas,
S. W. Kong,
H. C. Li,
L. Li,
X. Liu,
R. Marcinkowski,
S. Orsi,
M. Pohl,
D. Rybka,
J. C. Sun,
L. M. Song,
J. Szabelski,
R. J. Wang,
Y. H. Wang
, et al. (10 additional authors not shown)
Abstract:
POLAR is a new satellite-born detector aiming to measure the polarization of an unprecedented number of Gamma-Ray Bursts in the 50-500 keV energy range. The instrument, launched on-board the Tiangong-2 Chinese Space lab on the 15th of September 2016, is designed to measure the polarization of the hard X-ray flux by measuring the distribution of the azimuthal scattering angles of the incoming photo…
▽ More
POLAR is a new satellite-born detector aiming to measure the polarization of an unprecedented number of Gamma-Ray Bursts in the 50-500 keV energy range. The instrument, launched on-board the Tiangong-2 Chinese Space lab on the 15th of September 2016, is designed to measure the polarization of the hard X-ray flux by measuring the distribution of the azimuthal scattering angles of the incoming photons. A detailed understanding of the polarimeter and specifically of the systematic effects induced by the instrument's non-uniformity are required for this purpose. In order to study the instrument's response to polarization, POLAR underwent a beam test at the European Synchrotron Radiation Facility in France. In this paper both the beam test and the instrument performance will be described. This is followed by an overview of the Monte Carlo simulation tools developed for the instrument. Finally a comparison of the measured and simulated instrument performance will be provided and the instrument response to polarization will be presented.
△ Less
Submitted 2 August, 2017;
originally announced August 2017.
-
Calibration of the Space-borne Compton Polarimeter POLAR flight model with 100% polarized X-ray beams
Authors:
H. L. Xiao,
W. Hajdas,
P. Socha,
R. Marcinkowski,
B. B. Wu,
T. W. Bao,
J. Y. Chai,
Y. W. Dong,
M. N. Kong,
L. Li,
Z. H. Li,
J. T. Liu,
H. L. Shi,
L. M. Song,
J. C. Sun,
R. J. Wang,
Y. H. Wang,
X. Wen,
S. L. Xiong,
J. Zhang,
L. Y. Zhang,
S. N. Zhang,
X. F. Zhang,
Y. J. Zhang,
F. Cadoux
, et al. (10 additional authors not shown)
Abstract:
POLAR is space-borne detector designed for a precise measurement of gamma-ray polarization of the prompt emissions of Gamma-Ray Bursts in the energy range 50 keV - 500 keV. POLAR is a compact Compton polarimeter consisting of 40$\times$ 40 plastic scintillator bars read out by 25 multi-anode PMTs. In May 2015, we performed a series of tests of the POLAR flight model with 100\% polarized x-rays bea…
▽ More
POLAR is space-borne detector designed for a precise measurement of gamma-ray polarization of the prompt emissions of Gamma-Ray Bursts in the energy range 50 keV - 500 keV. POLAR is a compact Compton polarimeter consisting of 40$\times$ 40 plastic scintillator bars read out by 25 multi-anode PMTs. In May 2015, we performed a series of tests of the POLAR flight model with 100\% polarized x-rays beams at the European Synchrotron Radiation Facility beam-line ID11 aming to study thresholds, crosstalk between channels and responses of POLAR flight model to polarized X-ray beams. In this paper we present the data analysis method and some analysis results. According the results, POLAR FM has good polarimetric capabilities.
△ Less
Submitted 24 April, 2017; v1 submitted 20 April, 2017;
originally announced April 2017.
-
Gain factor and parameter settings optimization of the new gamma-ray burst polarimeter POLAR
Authors:
X. F. Zhang,
W. Hajdas,
H. L. Xiao,
X. Wen,
B. B. Wu,
T. W. Bao,
T. Batsch,
T. Bernasconi,
F. Cadoux,
I. Cernuda,
J. Y. Chai,
Y. W. Dong,
N. Gauvin,
J. J. He,
M. Kole,
M. N. Kong,
C. Lechanoine-Leluc,
L. Li,
Z. H. Li,
J. T. Liu,
X. Liu,
R. Marcinkowski,
S. Orsi,
M. Pohl,
D. Rapin
, et al. (16 additional authors not shown)
Abstract:
As a space-borne detector POLAR is designed to conduct hard X-ray polarization measurements of gamma-ray bursts on the statistically significant sample of events and with an unprecedented accuracy. During its development phase a number of tests, calibrations runs and verification measurements were carried out in order to validate instrument functionality and optimize operational parameters. In thi…
▽ More
As a space-borne detector POLAR is designed to conduct hard X-ray polarization measurements of gamma-ray bursts on the statistically significant sample of events and with an unprecedented accuracy. During its development phase a number of tests, calibrations runs and verification measurements were carried out in order to validate instrument functionality and optimize operational parameters. In this article we present results on gain optimization togeter with verification data obtained in the course of broad laboratory and environmental tests. In particular we focus on exposures to the $^{137}$Cs radioactive source and determination of the gain dependence on the high voltage for all 1600 detection channels of the polarimeter. Performance of the instrument is described in detail with respect to the dynamic range, energy resolution and temperature dependence. Gain optimization algorithms and response non-uniformity studies are also broadly discussed. Results presented below constitute important parts for development of the POLAR calibration and operation database.
△ Less
Submitted 14 March, 2017; v1 submitted 12 March, 2017;
originally announced March 2017.
-
Steering optical comb frequency by rotating polarization state
Authors:
Y. Zhang,
L. Yan,
X. F. Zhang,
L. Zhang,
W. Han,
W. Guo,
H. Jiang,
S. Zhang
Abstract:
Optical frequency combs, with precise control of repetition rate and carrier-envelope-offset frequency, have revolutionized many fields, such as fine optical spectroscopy, optical frequency standards, ultra-fast science research, ultra-stable microwave generation and precise ranging measurement. However, existing high bandwidth frequency control methods have small dynamic range, requiring complex…
▽ More
Optical frequency combs, with precise control of repetition rate and carrier-envelope-offset frequency, have revolutionized many fields, such as fine optical spectroscopy, optical frequency standards, ultra-fast science research, ultra-stable microwave generation and precise ranging measurement. However, existing high bandwidth frequency control methods have small dynamic range, requiring complex hybrid control techniques. To overcome this limitation, we develop a new approach, where a home-made intra-cavity electro-optic modulator tunes polarization state of laser signal rather than only optical length of the cavity, to steer frequencies of a nonlinear-polarization-rotation mode-locked laser. By taking advantage of birefringence of the whole cavity, this approach results in not only broadband but also relative large-dynamic frequency control. Experimental results show that frequency control dynamic range increase at least one order in comparison with the traditional intra-cavity electro-optic modulator technique. In additional, this technique exhibits less side-effect than traditional frequency control methods.
△ Less
Submitted 31 March, 2016;
originally announced March 2016.
-
Calibration of Gamma-ray Burst Polarimeter POLAR
Authors:
H. L. Xiao,
W. Hajdas,
T. W. Bao,
T. Batsch,
T. Bernasconi,
I. Cernuda,
J. Y. Chai,
Y. W. Dong,
N. Gauvin,
M. Kole,
M. N. Kong,
S. W. Kong,
L. Li,
J. T. Liu,
X. Liu,
R. Marcinkowski,
S. Orsi,
M. Pohl,
N. Produit,
D. Rapin,
A. Rutczynska,
D. Rybka,
H. L. Shi,
L. M. Song,
J. C. Sun
, et al. (11 additional authors not shown)
Abstract:
Gamma Ray Bursts (GRBs) are the strongest explosions in the universe which might be associated with creation of black holes. Magnetic field structure and burst dynamics may influence polarization of the emitted gamma-rays. Precise polarization detection can be an ultimate tool to unveil the true GRB mechanism. POLAR is a space-borne Compton scattering detector for precise measurements of the GRB p…
▽ More
Gamma Ray Bursts (GRBs) are the strongest explosions in the universe which might be associated with creation of black holes. Magnetic field structure and burst dynamics may influence polarization of the emitted gamma-rays. Precise polarization detection can be an ultimate tool to unveil the true GRB mechanism. POLAR is a space-borne Compton scattering detector for precise measurements of the GRB polarization. It consists of a 40$\times$40 array of plastic scintillator bars read out by 25 multi-anode PMTs (MaPMTs). It is scheduled to be launched into space in 2016 onboard of the Chinese space laboratory TG2. We present a dedicated methodology for POLAR calibration and some calibration results based on the combined use of the laboratory radioactive sources and polarized X-ray beams from the European Synchrotron Radiation Facility. They include calibration of the energy response, computation of the energy conversion factor vs. high voltage as well as determination of the threshold values, crosstalk contributions and polarization modulation factors.
△ Less
Submitted 9 December, 2015;
originally announced December 2015.
-
A "configurational-entropy-loss" law for the non-Arrhenius relaxation in disordered systems
Authors:
Yi-zhen Wang,
X. Frank Zhang,
**-xiu Zhang
Abstract:
Based on Nowick's self-induced ordering theory, we develop a new configurational-entropy relation to describe the non-Arrhenius temperature(T)-dependent relaxation in disordered systems. Both the configurational-entropy loss and the coupling interaction among relaxing units (RUs) are explicitly introduced in this relation; thus, it offers a novel connection between kinetics and thermodynamics that…
▽ More
Based on Nowick's self-induced ordering theory, we develop a new configurational-entropy relation to describe the non-Arrhenius temperature(T)-dependent relaxation in disordered systems. Both the configurational-entropy loss and the coupling interaction among relaxing units (RUs) are explicitly introduced in this relation; thus, it offers a novel connection between kinetics and thermodynamics that is different from the Adam-Gibbs (A-G) entropy relation, and it generalizes several well-known currently used relations. The present relation can provide direct and more accurate estimates of (i) the intrinsic activation enthalpy, (ii) the T-evolvement of the systematic configurational entropy loss and (iii) the self-induced ordering temperature Tc, which characterizes the coupling interaction among RUs. Application of the theory to experimental relaxation-time data for typical organic liquids demonstrates its validity.
△ Less
Submitted 4 December, 2012;
originally announced December 2012.
-
New insight into kinetics behavor of the structural formation process in Agar gelation
Authors:
Y. Z. Wang,
X. F. Zhang,
J. X. Zhang
Abstract:
A time-resolved experimental study on the kinetics and relaxation of the structural formation process in gelling Agar-water solutions was carried out using our custom-built torsion resonator. The study was based on measurements of three naturally cooled solutions with agar concentrations of 0.75%, 1.0% and 2.0% w/w. It was found that the natural-cooling agar gelation process could be divided into…
▽ More
A time-resolved experimental study on the kinetics and relaxation of the structural formation process in gelling Agar-water solutions was carried out using our custom-built torsion resonator. The study was based on measurements of three naturally cooled solutions with agar concentrations of 0.75%, 1.0% and 2.0% w/w. It was found that the natural-cooling agar gelation process could be divided into three stages, sol stage (Stage I), gelation zone (Stage II) and gel stage (Stage III), based on the time/temperature evolutions of the structural development rate (SDR). An interesting fluctuant decaying behavior of SDR was observed in Stage II and III, indicative of a sum of multiple relaxation processes and well described by a multiple-order Gaussisn-like equation: . More interestingly, the temperature dependences of the fitted values of Wn in Stage II and Stage III were found to follow the different Arrhenius laws, with different activation energies of EaII= 39-74 KJ/mol and EaIII~7.0 KJ/mol. The two different Arrhenius-like behaviors respectively suggest that dispersions in Stage II be attributed to the relaxation of the self-assembly of agar molecules or the growth of junction zones en route to gelation, in which the formation or fission of hydrogen bonding interactions plays an important role; and that dispersions in Stage III be attributed to the relaxation dynamics of water released from various size domains close to the domain of the viscous flow of water during the syneresis process.
△ Less
Submitted 24 July, 2011; v1 submitted 20 July, 2011;
originally announced July 2011.