STCF Conceptual Design Report: Volume 1 -- Physics & Detector
Authors:
M. Achasov,
X. C. Ai,
R. Aliberti,
L. P. An,
Q. An,
X. Z. Bai,
Y. Bai,
O. Bakina,
A. Barnyakov,
V. Blinov,
V. Bobrovnikov,
D. Bodrov,
A. Bogomyagkov,
A. Bondar,
I. Boyko,
Z. H. Bu,
F. M. Cai,
H. Cai,
J. J. Cao,
Q. H. Cao,
Z. Cao,
Q. Chang,
K. T. Chao,
D. Y. Chen,
H. Chen
, et al. (413 additional authors not shown)
Abstract:
The Super $τ$-Charm facility (STCF) is an electron-positron collider proposed by the Chinese particle physics community. It is designed to operate in a center-of-mass energy range from 2 to 7 GeV with a peak luminosity of $0.5\times 10^{35}{\rm cm}^{-2}{\rm s}^{-1}$ or higher. The STCF will produce a data sample about a factor of 100 larger than that by the present $τ$-Charm factory -- the BEPCII,…
▽ More
The Super $τ$-Charm facility (STCF) is an electron-positron collider proposed by the Chinese particle physics community. It is designed to operate in a center-of-mass energy range from 2 to 7 GeV with a peak luminosity of $0.5\times 10^{35}{\rm cm}^{-2}{\rm s}^{-1}$ or higher. The STCF will produce a data sample about a factor of 100 larger than that by the present $τ$-Charm factory -- the BEPCII, providing a unique platform for exploring the asymmetry of matter-antimatter (charge-parity violation), in-depth studies of the internal structure of hadrons and the nature of non-perturbative strong interactions, as well as searching for exotic hadrons and physics beyond the Standard Model. The STCF project in China is under development with an extensive R\&D program. This document presents the physics opportunities at the STCF, describes conceptual designs of the STCF detector system, and discusses future plans for detector R\&D and physics case studies.
△ Less
Submitted 5 October, 2023; v1 submitted 28 March, 2023;
originally announced March 2023.
-
$^{197}$Au($γ,\,xn;\,x\,=\,1\thicksim9$) Reaction Cross Section Measurements using Laser-Driven Ultra-Intense $γ$-Ray Source
Authors:
D. Wu,
H. Y. Lan,
J. Y. Zhang,
J. X. Liu,
H. G. Lu,
J. F. Lv,
X. Z. Wu,
H. Zhang,
J. Cai,
Q. Y. Ma,
Y. H. Xia,
Z. N. Wang,
M. Z. Wang,
Z. Y. Yang,
X. L. Xu,
Y. X. Geng,
Y. Y. Zhao,
C. Lin,
W. J. Ma,
J. Q. Yu,
H. R. Wang,
F. L. Liu,
C. Y. He,
B. Guo,
P. Zhu
, et al. (4 additional authors not shown)
Abstract:
We present a new method for the measurements of photonuclear reaction flux-weighted average cross sections and isomeric ratios using a laser-driven bremsstrahlung $γ$-ray source. An ultra-bright ultra-fast 60$\,\thicksim\,$250 MeV bremsstrahlung $γ$-ray source was established using the 200 TW laser facility in the Compact Laser Plasma Accelerator Laboratory, Peking University, which could cover th…
▽ More
We present a new method for the measurements of photonuclear reaction flux-weighted average cross sections and isomeric ratios using a laser-driven bremsstrahlung $γ$-ray source. An ultra-bright ultra-fast 60$\,\thicksim\,$250 MeV bremsstrahlung $γ$-ray source was established using the 200 TW laser facility in the Compact Laser Plasma Accelerator Laboratory, Peking University, which could cover the energy range from knocking out neutrons to producing pions. Stable quasi-monoenergetic electron beams were generated via laser wakefield acceleration with a charge of 300$\,\thicksim\,$600 pC per shot. The averaged $γ$-ray intensities ($\geqslant$8 MeV) were higher than 10$^{8}$ per shot and the instantaneous intensities can reach above 10$^{19}$ s$^{-1}$ with a duration time about 6.7 ps. $^{65}$Cu($γ,\,n$)$^{64}$Cu and $^{27}$Al($γ,\,x$)$^{24}$Na reactions were used as $γ$-ray flux monitors in the experiments. The flux-weighted average cross sections and isomeric ratios of $^{197}$Au($γ,\,xn;\,x\,=\,1\thicksim9$) reactions were analyzed through activation measurements. The results showed good agreement with previous works and proved this method to be accurate. The $^{197}$Au($γ,\,xn;\,x\,=\,7\thicksim\,9$) reaction cross sections were first achieved with the highest threshold energy of 71.410 MeV. Theoretical cross sections of TALYS 1.9 were calculated to compare with experiment results. This method offered a unique way of gaining insight into photonuclear reaction research, especially for short-lived isomers which extremely lack experimental data.
△ Less
Submitted 23 November, 2023; v1 submitted 28 September, 2022;
originally announced September 2022.
-
CUORE Opens the Door to Tonne-scale Cryogenics Experiments
Authors:
CUORE Collaboration,
D. Q. Adams,
C. Alduino,
F. Alessandria,
K. Alfonso,
E. Andreotti,
F. T. Avignone III,
O. Azzolini,
M. Balata,
I. Bandac,
T. I. Banks,
G. Bari,
M. Barucci,
J. W. Beeman,
F. Bellini,
G. Benato,
M. Beretta,
A. Bersani,
D. Biare,
M. Biassoni,
F. Bragazzi,
A. Branca,
C. Brofferio,
A. Bryant,
A. Buccheri
, et al. (184 additional authors not shown)
Abstract:
The past few decades have seen major developments in the design and operation of cryogenic particle detectors. This technology offers an extremely good energy resolution - comparable to semiconductor detectors - and a wide choice of target materials, making low temperature calorimetric detectors ideal for a variety of particle physics applications. Rare event searches have continued to require eve…
▽ More
The past few decades have seen major developments in the design and operation of cryogenic particle detectors. This technology offers an extremely good energy resolution - comparable to semiconductor detectors - and a wide choice of target materials, making low temperature calorimetric detectors ideal for a variety of particle physics applications. Rare event searches have continued to require ever greater exposures, which has driven them to ever larger cryogenic detectors, with the CUORE experiment being the first to reach a tonne-scale, mK-cooled, experimental mass. CUORE, designed to search for neutrinoless double beta decay, has been operational since 2017 at a temperature of about 10 mK. This result has been attained by the use of an unprecedentedly large cryogenic infrastructure called the CUORE cryostat: conceived, designed and commissioned for this purpose. In this article the main characteristics and features of the cryogenic facility developed for the CUORE experiment are highlighted. A brief introduction of the evolution of the field and of the past cryogenic facilities are given. The motivation behind the design and development of the CUORE cryogenic facility is detailed as are the steps taken toward realization, commissioning, and operation of the CUORE cryostat. The major challenges overcome by the collaboration and the solutions implemented throughout the building of the cryogenic facility will be discussed along with the potential improvements for future facilities. The success of CUORE has opened the door to a new generation of large-scale cryogenic facilities in numerous fields of science. Broader implications of the incredible feat achieved by the CUORE collaboration on the future cryogenic facilities in various fields ranging from neutrino and dark matter experiments to quantum computing will be examined.
△ Less
Submitted 2 December, 2021; v1 submitted 17 August, 2021;
originally announced August 2021.
-
Optimization of the JUNO liquid scintillator composition using a Daya Bay antineutrino detector
Authors:
Daya Bay,
JUNO collaborations,
:,
A. Abusleme,
T. Adam,
S. Ahmad,
S. Aiello,
M. Akram,
N. Ali,
F. P. An,
G. P. An,
Q. An,
G. Andronico,
N. Anfimov,
V. Antonelli,
T. Antoshkina,
B. Asavapibhop,
J. P. A. M. de André,
A. Babic,
A. B. Balantekin,
W. Baldini,
M. Baldoncini,
H. R. Band,
A. Barresi,
E. Baussan
, et al. (642 additional authors not shown)
Abstract:
To maximize the light yield of the liquid scintillator (LS) for the Jiangmen Underground Neutrino Observatory (JUNO), a 20 t LS sample was produced in a pilot plant at Daya Bay. The optical properties of the new LS in various compositions were studied by replacing the gadolinium-loaded LS in one antineutrino detector. The concentrations of the fluor, PPO, and the wavelength shifter, bis-MSB, were…
▽ More
To maximize the light yield of the liquid scintillator (LS) for the Jiangmen Underground Neutrino Observatory (JUNO), a 20 t LS sample was produced in a pilot plant at Daya Bay. The optical properties of the new LS in various compositions were studied by replacing the gadolinium-loaded LS in one antineutrino detector. The concentrations of the fluor, PPO, and the wavelength shifter, bis-MSB, were increased in 12 steps from 0.5 g/L and <0.01 mg/L to 4 g/L and 13 mg/L, respectively. The numbers of total detected photoelectrons suggest that, with the optically purified solvent, the bis-MSB concentration does not need to be more than 4 mg/L. To bridge the one order of magnitude in the detector size difference between Daya Bay and JUNO, the Daya Bay data were used to tune the parameters of a newly developed optical model. Then, the model and tuned parameters were used in the JUNO simulation. This enabled to determine the optimal composition for the JUNO LS: purified solvent LAB with 2.5 g/L PPO, and 1 to 4 mg/L bis-MSB.
△ Less
Submitted 1 July, 2020;
originally announced July 2020.
-
Double-beta decay of ${}^{130}$Te to the first $0^+$ excited state of ${}^{130}$Xe with CUORE-0
Authors:
CUORE Collaboration,
C. Alduino,
K. Alfonso,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
T. I. Banks,
G. Bari,
J. W. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
C. Brofferio,
C. Bucci,
A. Caminata,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Carbone,
L. Cardani,
P. Carniti,
N. Casali,
L. Cassina,
D. Chiesa
, et al. (96 additional authors not shown)
Abstract:
We report on a search for double beta decay of $^{130}$Te to the first $0^{+}$ excited state of $^{130}$Xe using a 9.8 kg$\cdot$yr exposure of $^{130}$Te collected with the CUORE-0 experiment. In this work we exploit different topologies of coincident events to search for both the neutrinoless and two-neutrino double-decay modes. We find no evidence for either mode and place lower bounds on the ha…
▽ More
We report on a search for double beta decay of $^{130}$Te to the first $0^{+}$ excited state of $^{130}$Xe using a 9.8 kg$\cdot$yr exposure of $^{130}$Te collected with the CUORE-0 experiment. In this work we exploit different topologies of coincident events to search for both the neutrinoless and two-neutrino double-decay modes. We find no evidence for either mode and place lower bounds on the half-lives: $τ^{0ν}_{0^+}>7.9\cdot 10^{23}$ yr and $τ^{2ν}_{0^+}>2.4\cdot 10^{23}$ yr. Combining our results with those obtained by the CUORICINO experiment, we achieve the most stringent constraints available for these processes: $τ^{0ν}_{0^+}>1.4\cdot 10^{24}$ yr and $τ^{2ν}_{0^+}>2.5\cdot 10^{23}$ yr.
△ Less
Submitted 29 November, 2018; v1 submitted 26 November, 2018;
originally announced November 2018.
-
Update on the recent progress of the CUORE experiment
Authors:
CUORE Collaboration,
D. Q. Adams,
C. Alduino,
K. Alfonso,
F. T. Avignone III,
O. Azzolini,
G. Bari,
F. Bellini,
G. Benato,
A. Bersani,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
A. Caminata,
A. Campani,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti,
N. Casali,
L. Cassina,
D. Chiesa
, et al. (96 additional authors not shown)
Abstract:
CUORE is a 741 kg array of 988 TeO$_2$ bolometeric crystals designed to search for the neutrinoless double beta decay of $^{130}$Te and other rare processes. CUORE has been taking data since summer 2017, and as of summer 2018 collected a total of 86.3 kg$\cdot$yr of TeO$_2$ exposure. Based on this exposure, we were able to set a limit on the $0νββ$ half-life of $^{130}$Te of…
▽ More
CUORE is a 741 kg array of 988 TeO$_2$ bolometeric crystals designed to search for the neutrinoless double beta decay of $^{130}$Te and other rare processes. CUORE has been taking data since summer 2017, and as of summer 2018 collected a total of 86.3 kg$\cdot$yr of TeO$_2$ exposure. Based on this exposure, we were able to set a limit on the $0νββ$ half-life of $^{130}$Te of $T^{0ν}_{1/2}>1.5\times10^{25}$ yr at 90% C.L. At this conference, we showed the decomposition of the CUORE background and were able to extract a $^{130}$Te $2νββ$ half-life of $T_{1/2}^{2ν}=[7.9\pm0.1 \mathrm{(stat.)}\pm0.2 \mathrm{(syst.)}]\times10^{20}$ yr. This is the most precise measurement of this half-life and is consistent with previous measurements.
△ Less
Submitted 30 August, 2018;
originally announced August 2018.
-
Study of Rare Nuclear Processes with CUORE
Authors:
CUORE Collaboration,
C. Alduino,
K. Alfonso,
F. T. Avignone III,
O. Azzolini,
G. Bari,
F. Bellini,
G. Benato,
A. Bersani,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
A. Caminata,
A. Campani,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti,
N. Casali,
L. Cassina,
D. Chiesa,
N. Chott
, et al. (94 additional authors not shown)
Abstract:
TeO2 bolometers have been used for many years to search for neutrinoless double beta decay in 130-Te. CUORE, a tonne-scale TeO2 detector array, recently published the most sensitive limit on the half-life, $T_{1/2}^{0ν} > 1.5 \times 10^{25}\,$yr, which corresponds to an upper bound of $140-400$~meV on the effective Majorana mass of the neutrino. While it makes CUORE a world-leading experiment look…
▽ More
TeO2 bolometers have been used for many years to search for neutrinoless double beta decay in 130-Te. CUORE, a tonne-scale TeO2 detector array, recently published the most sensitive limit on the half-life, $T_{1/2}^{0ν} > 1.5 \times 10^{25}\,$yr, which corresponds to an upper bound of $140-400$~meV on the effective Majorana mass of the neutrino. While it makes CUORE a world-leading experiment looking for neutrinoless double beta decay, it is not the only study that CUORE will contribute to in the field of nuclear and particle physics. As already done over the years with many small-scale experiments, CUORE will investigate both rare decays (such as the two-neutrino double beta decay of 130-Te and the hypothesized electron capture in 123-Te), and rare processes (e.g., dark matter and axion interactions). This paper describes some of the achievements of past experiments that used TeO2 bolometers, and perspectives for CUORE.
△ Less
Submitted 17 January, 2018; v1 submitted 16 January, 2018;
originally announced January 2018.
-
First Results from CUORE: A Search for Lepton Number Violation via $0νββ$ Decay of $^{130}$Te
Authors:
CUORE Collaboration,
C. Alduino,
K. Alfonso,
E. Andreotti,
C. Arnaboldi,
F. T. Avignone III,
O. Azzolini,
I. Bandac,
T. I. Banks,
G. Bari,
M. Barucci,
J. W. Beeman,
F. Bellini,
G. Benato,
A. Bersani,
D. Biare,
M. Biassoni,
A. Branca,
C. Brofferio,
A. Bryant,
A. Buccheri,
C. Bucci,
C. Bulfon,
A. Camacho,
A. Caminata
, et al. (140 additional authors not shown)
Abstract:
The CUORE experiment, a ton-scale cryogenic bolometer array, recently began operation at the Laboratori Nazionali del Gran Sasso in Italy. The array represents a significant advancement in this technology, and in this work we apply it for the first time to a high-sensitivity search for a lepton-number--violating process: $^{130}$Te neutrinoless double-beta decay. Examining a total TeO$_2$ exposure…
▽ More
The CUORE experiment, a ton-scale cryogenic bolometer array, recently began operation at the Laboratori Nazionali del Gran Sasso in Italy. The array represents a significant advancement in this technology, and in this work we apply it for the first time to a high-sensitivity search for a lepton-number--violating process: $^{130}$Te neutrinoless double-beta decay. Examining a total TeO$_2$ exposure of 86.3 kg$\cdot$yr, characterized by an effective energy resolution of (7.7 $\pm$ 0.5) keV FWHM and a background in the region of interest of (0.014 $\pm$ 0.002) counts/(keV$\cdot$kg$\cdot$yr), we find no evidence for neutrinoless double-beta decay. The median statistical sensitivity of this search is $7.0\times10^{24}$ yr. Including systematic uncertainties, we place a lower limit on the decay half-life of $T^{0ν}_{1/2}$($^{130}$Te) > $1.3\times 10^{25}$ yr (90% C.L.). Combining this result with those of two earlier experiments, Cuoricino and CUORE-0, we find $T^{0ν}_{1/2}$($^{130}$Te) > $1.5\times 10^{25}$ yr (90% C.L.), which is the most stringent limit to date on this decay. Interpreting this result as a limit on the effective Majorana neutrino mass, we find $m_{ββ}<(110 - 520)$ meV, where the range reflects the nuclear matrix element estimates employed.
△ Less
Submitted 1 April, 2018; v1 submitted 22 October, 2017;
originally announced October 2017.
-
Low Energy Analysis Techniques for CUORE
Authors:
CUORE Collaboration,
C. Alduino,
K. Alfonso,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
G. Bari,
J. W. Beeman,
F. Bellini,
G. Benato,
A. Bersani,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
A. Camacho,
A. Caminata,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti,
N. Casali,
L. Cassina
, et al. (99 additional authors not shown)
Abstract:
CUORE is a tonne-scale cryogenic detector operating at the Laboratori Nazionali del Gran Sasso (LNGS) that uses tellurium dioxide bolometers to search for neutrinoless double-beta decay of $^{130}$Te. CUORE is also suitable to search for low energy rare events such as solar axions or WIMP scattering, thanks to its ultra-low background and large target mass. However, to conduct such sensitive searc…
▽ More
CUORE is a tonne-scale cryogenic detector operating at the Laboratori Nazionali del Gran Sasso (LNGS) that uses tellurium dioxide bolometers to search for neutrinoless double-beta decay of $^{130}$Te. CUORE is also suitable to search for low energy rare events such as solar axions or WIMP scattering, thanks to its ultra-low background and large target mass. However, to conduct such sensitive searches requires improving the energy threshold to 10 keV. In this paper, we describe the analysis techniques developed for the low energy analysis of CUORE-like detectors, using the data acquired from November 2013 to March 2015 by CUORE-0, a single-tower prototype designed to validate the assembly procedure and new cleaning techniques of CUORE. We explain the energy threshold optimization, continuous monitoring of the trigger efficiency, data and event selection, and energy calibration at low energies in detail. We also present the low energy background spectrum of CUORE-0 below 60keV. Finally, we report the sensitivity of CUORE to WIMP annual modulation using the CUORE-0 energy threshold and background, as well as an estimate of the uncertainty on the nuclear quenching factor from nuclear recoils in CUORE-0.
△ Less
Submitted 14 December, 2017; v1 submitted 25 August, 2017;
originally announced August 2017.
-
CUORE Sensitivity to $0νββ$ Decay
Authors:
CUORE Collaboration,
C. Alduino,
K. Alfonso,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
T. I. Banks,
G. Bari,
J. W. Beeman,
F. Bellini,
G. Benato,
A. Bersani,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
A. Camacho,
A. Caminata,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Carbone,
L. Cardani,
P. Carniti
, et al. (106 additional authors not shown)
Abstract:
We report a study of the CUORE sensitivity to neutrinoless double beta ($0νββ$) decay. We used a Bayesian analysis based on a toy Monte Carlo (MC) approach to extract the exclusion sensitivity to the $0νββ$ decay half-life ($T_{1/2}^{0ν}$) at $90\%$ credibility interval (CI) -- i.e. the interval containing the true value of $T_{1/2}^{0ν}$ with $90\%$ probability -- and the $3 σ$ discovery sensitiv…
▽ More
We report a study of the CUORE sensitivity to neutrinoless double beta ($0νββ$) decay. We used a Bayesian analysis based on a toy Monte Carlo (MC) approach to extract the exclusion sensitivity to the $0νββ$ decay half-life ($T_{1/2}^{0ν}$) at $90\%$ credibility interval (CI) -- i.e. the interval containing the true value of $T_{1/2}^{0ν}$ with $90\%$ probability -- and the $3 σ$ discovery sensitivity. We consider various background levels and energy resolutions, and describe the influence of the data division in subsets with different background levels. If the background level and the energy resolution meet the expectation, CUORE will reach a $90\%$ CI exclusion sensitivity of $2\cdot10^{25}$ yr with $3$ months, and $9\cdot10^{25}$ yr with $5$ years of live time. Under the same conditions, the discovery sensitivity after $3$ months and $5$ years will be $7\cdot10^{24}$ yr and $4\cdot10^{25}$ yr, respectively.
△ Less
Submitted 14 August, 2017; v1 submitted 30 May, 2017;
originally announced May 2017.
-
The projected background for the CUORE experiment
Authors:
CUORE Collaboration,
C. Alduino,
K. Alfonso,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
T. I. Banks,
G. Bari,
J. W. Beeman,
F. Bellini,
G. Benato,
A. Bersani,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
A. Camacho,
A. Caminata,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Carbone,
L. Cardani,
P. Carniti
, et al. (107 additional authors not shown)
Abstract:
The Cryogenic Underground Observatory for Rare Events (CUORE) is designed to search for neutrinoless double beta decay of 130Te with an array of 988 TeO2 bolometers operating at temperatures around 10 mK. The experiment is currently being commissioned in Hall A of Laboratori Nazionali del Gran Sasso, Italy. The goal of CUORE is to reach a 90\% C.L. exclusion sensitivity on the \tect decay half-lif…
▽ More
The Cryogenic Underground Observatory for Rare Events (CUORE) is designed to search for neutrinoless double beta decay of 130Te with an array of 988 TeO2 bolometers operating at temperatures around 10 mK. The experiment is currently being commissioned in Hall A of Laboratori Nazionali del Gran Sasso, Italy. The goal of CUORE is to reach a 90\% C.L. exclusion sensitivity on the \tect decay half-life of 9$\times$10$^{25}$ years after 5\,years of data taking. The main issue to be addressed to accomplish this aim is the rate of background events in the region of interest, which must not be higher than 10$^{-2}$\,counts/keV/kg/y. We developed a detailed Monte Carlo simulation, based on results from a campaign of material screening, radioassays, and bolometric measurements, to evaluate the expected background. This was used over the years to guide the construction strategies of the experiment and we use it here to project a background model for CUORE. In this paper we report the results of our study and our expectations for the background rate in the energy region where the peak signature of neutrinoless double beta decay of 130Te is expected.
△ Less
Submitted 31 August, 2017; v1 submitted 28 April, 2017;
originally announced April 2017.
-
The CUORE and CUORE-0 experiments at LNGS
Authors:
A. D'Addabbo,
C. Alduino,
K. Alfonso,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
T. I. Banks,
G. Bari,
J. W. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
A. Camacho,
A. Caminata,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Carbone,
L. Cardani,
P. Carniti,
N. Casali
, et al. (100 additional authors not shown)
Abstract:
The Cryogenic Underground Observatory for Rare Events (CUORE) is a 1-ton scale bolometric experiment devoted to the search of the neutrinoless double-beta decay (0ν\b{eta}\b{eta}) in 130Te. The CUORE detector consists of an array of 988 TeO2 crystals operated at 10 mK. CUORE-0 is the CUORE demonstrator: it has been built to test the performance of the upcoming CUORE experiment and represents the l…
▽ More
The Cryogenic Underground Observatory for Rare Events (CUORE) is a 1-ton scale bolometric experiment devoted to the search of the neutrinoless double-beta decay (0ν\b{eta}\b{eta}) in 130Te. The CUORE detector consists of an array of 988 TeO2 crystals operated at 10 mK. CUORE-0 is the CUORE demonstrator: it has been built to test the performance of the upcoming CUORE experiment and represents the largest 130Te bolometric setup ever operated. CUORE-0 has been running at Laboratori Nazionali del Gran Sasso (Italy) from 2013 to 2015. The final CUORE-0 analysis on 0ν\b{eta}\b{eta} and the corresponding detector performance are presented. The present status of the CUORE experiment, now in its final construction and commissioning phase, are discussed. The results from assembly of the detector and the commissioning of the cryostat are reported.
△ Less
Submitted 13 December, 2016;
originally announced December 2016.
-
CUORE-0 detector: design, construction and operation
Authors:
CUORE Collaboration,
C. Alduino,
K. Alfonso,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
M. Balata,
T. I. Banks,
G. Bari,
J. W. Beeman,
F. Bellini,
A. Bersani,
D. Biare,
M. Biassoni,
F. Bragazzi,
C. Brofferio,
A. Buccheri,
C. Bucci,
C. Bulfon,
A. Caminata,
L. Canonica,
X. G. Cao,
S. Capelli,
M. Capodiferro,
L. Cappelli
, et al. (129 additional authors not shown)
Abstract:
The CUORE experiment will search for neutrinoless double-beta decay of $^{130}$Te with an array of 988 TeO$_2$ bolometers arranged in 19 towers. CUORE-0, the first tower assembled according to the CUORE procedures, was built and commissioned at Laboratori Nazionali del Gran Sasso, and took data from March 2013 to March 2015. In this paper we describe the design, construction and operation of the C…
▽ More
The CUORE experiment will search for neutrinoless double-beta decay of $^{130}$Te with an array of 988 TeO$_2$ bolometers arranged in 19 towers. CUORE-0, the first tower assembled according to the CUORE procedures, was built and commissioned at Laboratori Nazionali del Gran Sasso, and took data from March 2013 to March 2015. In this paper we describe the design, construction and operation of the CUORE-0 experiment, with an emphasis on the improvements made over a predecessor experiment, Cuoricino. In particular, we demonstrate with CUORE-0 data that the design goals of CUORE are within reach.
△ Less
Submitted 18 July, 2016; v1 submitted 19 April, 2016;
originally announced April 2016.
-
Analysis Techniques for the Evaluation of the Neutrinoless Double-Beta Decay Lifetime in $^{130}$Te with CUORE-0
Authors:
CUORE Collaboration,
C. Alduino,
K. Alfonso,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
T. I. Banks,
G. Bari,
J. W. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
C. Brofferio,
C. Bucci,
A. Caminata,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Carbone,
L. Cardani,
P. Carniti,
N. Casali,
L. Cassina,
D. Chiesa
, et al. (96 additional authors not shown)
Abstract:
We describe in detail the methods used to obtain the lower bound on the lifetime of neutrinoless double-beta ($0νββ$) decay in $^{130}$Te and the associated limit on the effective Majorana mass of the neutrino using the CUORE-0 detector. CUORE-0 is a bolometric detector array located at the Laboratori Nazionali del Gran Sasso that was designed to validate the background reduction techniques develo…
▽ More
We describe in detail the methods used to obtain the lower bound on the lifetime of neutrinoless double-beta ($0νββ$) decay in $^{130}$Te and the associated limit on the effective Majorana mass of the neutrino using the CUORE-0 detector. CUORE-0 is a bolometric detector array located at the Laboratori Nazionali del Gran Sasso that was designed to validate the background reduction techniques developed for CUORE, a next-generation experiment scheduled to come online in 2016. CUORE-0 is also a competitive $0νββ$ decay search in its own right and functions as a platform to further develop the analysis tools and procedures to be used in CUORE. These include data collection, event selection and processing, as well as an evaluation of signal efficiency. In particular, we describe the amplitude evaluation, thermal gain stabilization, energy calibration methods, and the analysis event selection used to create our final $0νββ$ decay search spectrum. We define our high level analysis procedures, with emphasis on the new insights gained and challenges encountered. We outline in detail our fitting methods near the hypothesized $0νββ$ decay peak and catalog the main sources of systematic uncertainty. Finally, we derive the $0νββ$ decay half-life limits previously reported for CUORE-0, $T^{0ν}_{1/2}>2.7\times10^{24}$ yr, and in combination with the Cuoricino limit, $T^{0ν}_{1/2}>4.0\times10^{24}$ yr.
△ Less
Submitted 27 April, 2016; v1 submitted 6 January, 2016;
originally announced January 2016.
-
Search for Neutrinoless Double-Beta Decay of $^{130}$Te with CUORE-0
Authors:
K. Alfonso,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
M. Balata,
T. I. Banks,
G. Bari,
J. W. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
C. Brofferio,
C. Bucci,
A. Caminata,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Carbone,
L. Cardani,
N. Casali,
L. Cassina,
D. Chiesa,
N. Chott,
M. Clemenza
, et al. (93 additional authors not shown)
Abstract:
We report the results of a search for neutrinoless double-beta decay in a 9.8~kg$\cdot$yr exposure of $^{130}$Te using a bolometric detector array, CUORE-0. The characteristic detector energy resolution and background level in the region of interest are $5.1\pm 0.3{\rm~keV}$ FWHM and $0.058 \pm 0.004\,(\mathrm{stat.})\pm 0.002\,(\mathrm{syst.})$~counts/(keV$\cdot$kg$\cdot$yr), respectively. The me…
▽ More
We report the results of a search for neutrinoless double-beta decay in a 9.8~kg$\cdot$yr exposure of $^{130}$Te using a bolometric detector array, CUORE-0. The characteristic detector energy resolution and background level in the region of interest are $5.1\pm 0.3{\rm~keV}$ FWHM and $0.058 \pm 0.004\,(\mathrm{stat.})\pm 0.002\,(\mathrm{syst.})$~counts/(keV$\cdot$kg$\cdot$yr), respectively. The median 90%~C.L. lower-limit sensitivity of the experiment is $2.9\times 10^{24}~{\rm yr}$ and surpasses the sensitivity of previous searches. We find no evidence for neutrinoless double-beta decay of $^{130}$Te and place a Bayesian lower bound on the decay half-life, $T^{0ν}_{1/2}>$~$ 2.7\times 10^{24}~{\rm yr}$ at 90%~C.L. Combining CUORE-0 data with the 19.75~kg$\cdot$yr exposure of $^{130}$Te from the Cuoricino experiment we obtain $T^{0ν}_{1/2} > 4.0\times 10^{24}~\mathrm{yr}$ at 90%~C.L.~(Bayesian), the most stringent limit to date on this half-life. Using a range of nuclear matrix element estimates we interpret this as a limit on the effective Majorana neutrino mass, $m_{ββ}< 270$ -- $760~\mathrm{meV}$.
△ Less
Submitted 1 October, 2015; v1 submitted 9 April, 2015;
originally announced April 2015.
-
Status of the CUORE and results from the CUORE-0 neutrinoless double beta decay experiments
Authors:
CUORE Collaboration,
M. Sisti,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
M. Balata,
T. I. Banks,
G. Bari,
J. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
C. Brofferio,
C. Bucci,
X. Z. Cai,
A. Camacho,
A. Caminata,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Carbone,
L. Cardani,
N. Casali,
L. Cassina
, et al. (103 additional authors not shown)
Abstract:
CUORE is a 741 kg array of TeO2 bolometers for the search of neutrinoless double beta decay of 130Te. The detector is being constructed at the Laboratori Nazionali del Gran Sasso, Italy, where it will start taking data in 2015. If the target background of 0.01 counts/keV/kg/y will be reached, in five years of data taking CUORE will have a 1 sigma half life sensitivity of 10E26 y. CUORE-0 is a smal…
▽ More
CUORE is a 741 kg array of TeO2 bolometers for the search of neutrinoless double beta decay of 130Te. The detector is being constructed at the Laboratori Nazionali del Gran Sasso, Italy, where it will start taking data in 2015. If the target background of 0.01 counts/keV/kg/y will be reached, in five years of data taking CUORE will have a 1 sigma half life sensitivity of 10E26 y. CUORE-0 is a smaller experiment constructed to test and demonstrate the performances expected for CUORE. The detector is a single tower of 52 CUORE-like bolometers that started taking data in spring 2013. The status and perspectives of CUORE will be discussed, and the first CUORE-0 data will be presented.
△ Less
Submitted 12 February, 2015;
originally announced February 2015.
-
CUORE-0 results and prospects for the CUORE experiment
Authors:
CUORE Collaboration,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
M. Balata,
T. I. Banks,
G. Bari,
J. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
C. Brofferio,
C. Bucci,
X. Z. Cai,
A. Camacho,
A. Caminata,
L. Canonica,
X. Cao,
S. Capelli,
L. Cappelli,
L. Carbone,
L. Cardani,
N. Casali,
L. Cassina,
D. Chiesa
, et al. (105 additional authors not shown)
Abstract:
With 741 kg of TeO2 crystals and an excellent energy resolution of 5 keV (0.2%) at the region of interest, the CUORE (Cryogenic Underground Observatory for Rare Events) experiment aims at searching for neutrinoless double beta decay of 130Te with unprecedented sensitivity. Expected to start data taking in 2015, CUORE is currently in an advanced construction phase at LNGS. CUORE projected neutrinol…
▽ More
With 741 kg of TeO2 crystals and an excellent energy resolution of 5 keV (0.2%) at the region of interest, the CUORE (Cryogenic Underground Observatory for Rare Events) experiment aims at searching for neutrinoless double beta decay of 130Te with unprecedented sensitivity. Expected to start data taking in 2015, CUORE is currently in an advanced construction phase at LNGS. CUORE projected neutrinoless double beta decay half-life sensitivity is 1.6E26 y at 1 sigma (9.5E25 y at the 90% confidence level), in five years of live time, corresponding to an upper limit on the effective Majorana mass in the range 40-100 meV (50-130 meV). Further background rejection with auxiliary bolometric detectors could improve CUORE sensitivity and competitiveness of bolometric detectors towards a full analysis of the inverted neutrino mass hierarchy. CUORE-0 was built to test and demonstrate the performance of the upcoming CUORE experiment. It consists of a single CUORE tower (52 TeO2 bolometers of 750 g each, arranged in a 13 floor structure) constructed strictly following CUORE recipes both for materials and assembly procedures. An experiment its own, CUORE-0 is expected to reach a sensitivity to the neutrinoless double beta decay half-life of 130Te around 3E24 y in one year of live time. We present an update of the data, corresponding to an exposure of 18.1 kg y. An analysis of the background indicates that the CUORE performance goal is satisfied while the sensitivity goal is within reach.
△ Less
Submitted 9 February, 2015;
originally announced February 2015.
-
The CUORE and CUORE-0 Experiments at Gran Sasso
Authors:
A. Giachero,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
M. Balata,
T. I. Banks,
G. Bari,
J. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
C. Brofferio,
C. Bucci,
X. Z. Cai,
A. Camacho,
A. Caminata,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Carbone,
L. Cardani,
N. Casali,
L. Cassina,
D. Chiesa
, et al. (103 additional authors not shown)
Abstract:
The Cryogenic Underground Observatory for Rare Events (CUORE) is an experiment to search for neutrinoless double beta decay ($0νββ$) in $^{130}$Te and other rare processes. CUORE is a cryogenic detector composed of 988 TeO$_2$ bolometers for a total mass of about 741 kg. The detector is being constructed at the Laboratori Nazionali del Gran Sasso, Italy, where it will start taking data in 2015. If…
▽ More
The Cryogenic Underground Observatory for Rare Events (CUORE) is an experiment to search for neutrinoless double beta decay ($0νββ$) in $^{130}$Te and other rare processes. CUORE is a cryogenic detector composed of 988 TeO$_2$ bolometers for a total mass of about 741 kg. The detector is being constructed at the Laboratori Nazionali del Gran Sasso, Italy, where it will start taking data in 2015. If the target background of 0.01 counts/(keV$\cdot$kg$\cdot$y) will be reached, in five years of data taking CUORE will have an half life sensitivity around $1\times 10^{26}$ y at 90\% C.L. As a first step towards CUORE a smaller experiment CUORE-0, constructed to test and demonstrate the performances expected for CUORE, has been assembled and is running. The detector is a single tower of 52 CUORE-like bolometers that started taking data in spring 2013. The status and perspectives of CUORE will be discussed, and the first CUORE-0 data will be presented.
△ Less
Submitted 9 June, 2015; v1 submitted 27 October, 2014;
originally announced October 2014.