-
Biocompatible wearable touch panel based on ionically conductive organic hydrogels with anti-freezing, anti-dehydration, self-healing, and underwater adhesion properties
Authors:
Zhenglin Chen,
Jiaqi Yang,
Likun Zhang,
Haifei Guana,
Zhengyang Lei,
Xiaopeng Zhang,
Canhui Yang,
Ying Zhua,
Qianhui Sun,
Lulu Xua,
Ziheng Zhanga,
Sen Zeng,
Chuhui Wang,
Rongxu Yan,
Chong Zhang,
Peter E Lobie,
Dongmei Yu,
Peiwu Qin,
Can Yang Zhang
Abstract:
Next-generation touch panels are poised to benefit from the use of stretchable and transparent soft ionic conductors, but these materials face several challenges in practical application, including structural damage, loss of functionality, and device stratification, particularly in extreme environments. To address these challenges, in this work, a biocompatible, transparent, self-adhesive gelatin-…
▽ More
Next-generation touch panels are poised to benefit from the use of stretchable and transparent soft ionic conductors, but these materials face several challenges in practical application, including structural damage, loss of functionality, and device stratification, particularly in extreme environments. To address these challenges, in this work, a biocompatible, transparent, self-adhesive gelatin-PAA-based organic hydrogel (PC-OH) was developed, the gel can adhere to the skin in both air and underwater conditions and also anti-freezing, anti-drying, fast self-healable (with a self-healing time of less than 4s in air and underwater), long-term stable for up to 7 days at a wide range of temperatures, highly stretchable, and conductive over a wide temperature range. Using this organic hydrogel, an organic hydrogel-based surface capacitive touch system has been developed that can detect finger touch position in wet environments and over a wide temperature range, demonstrating its ability to sense finger touch position. The wearable touch panel has been successfully demonstrated through the ability to write text, draw figures, and play electronic games, showcasing its potential use in various applications. This breakthrough has significant implications for the development of next-generation touch panels, particularly in the healthcare, sports, and entertainment industries, where reliable and versatile human-machine interfaces are essential.
△ Less
Submitted 7 September, 2023; v1 submitted 27 August, 2023;
originally announced August 2023.
-
Precise determination of the 2s22p5-2s2p6 transition energy in fluorine-like nickel utilizing a low-lying dielectronic resonance
Authors:
S. X. Wang,
Z. K. Huang,
W. Q. Wen,
W. L. Ma,
H. B. Wang,
S. Schippers,
Z. W. Wu,
Y. S. Kozhedub,
M. Y. Kaygorodov,
A. V. Volotka,
K. Wang,
C. Y. Zhang,
C. Y. Chen,
C. Liu,
H. K. Huang,
L. Shao,
L. J. Mao,
X. M. Ma,
J. Li,
M. T. Tang,
K. M. Yan,
Y. B. Zhou,
Y. J. Yuan,
J. C. Yang,
S. F. Zhang
, et al. (2 additional authors not shown)
Abstract:
High precision spectroscopy of the low-lying dielectronic resonances in fluorine-like nickel ions were determined by employing the merged electron-ion beam at the heavy-ion storage ring CSRm. The measured dielectronic resonances are identified by comparing with the most recent relativistic calculation utilizing the FAC code. The first resonance at about 86 meV due to the dielectronic recombination…
▽ More
High precision spectroscopy of the low-lying dielectronic resonances in fluorine-like nickel ions were determined by employing the merged electron-ion beam at the heavy-ion storage ring CSRm. The measured dielectronic resonances are identified by comparing with the most recent relativistic calculation utilizing the FAC code. The first resonance at about 86 meV due to the dielectronic recombination via (2s2p6[2S1/2]6s)J=1 intermediate state was recognized. The experimental determination of the resonance position at 86 meV reaches an uncertainty of 4 meV, which allows precise determination of the 2s22p5[2P3/2] - 2s2p6[2S1/2] transition energy. The Rydberg binding energy of the 6s electron in the (2s2p6[2S1/2]6s)J=1 state is calculated by the multi-configurational Dirac-HartreeFock and stabilization methods. The determined transition energies are 149.056(4)exp(10)theo and 149.032(4)exp(6)theo, respectively. Moreover, the transition energy has also been calculated by fully relativistic and ab initio approaches. Individual theoretical contributions are evaluated by employing the core-Hartree and Kohn-Sham screening potentials, respectively. High-order QED and correlation effects contribute prominently to the total transition energy. The present DR precision spectroscopy study at the CSRm paves the way for future precision measurements of atomic energy levels with heavier highly charged ions.
△ Less
Submitted 25 May, 2022; v1 submitted 3 May, 2022;
originally announced May 2022.
-
The Design and Performance of Charged Particle Detector onboard the GECAM Mission
Authors:
Y. B. Xu,
X. L. Sun,
S. Yang,
X. Q. Li,
W. X. Peng,
K. Gong,
X. H. Liang,
Y. Q. Liu,
D. Y. Guo,
H. Wang,
C. Y. Li,
Z. H. An,
J. J. He,
X. J. Liu,
S. L. Xiong,
X. Y. Wen,
Fan Zhang,
D. L. Zhang,
X. Y. Zhao,
C. Y. Zhang,
C. Cai,
Z. Chang,
G. Chen,
C. Chen,
Y. Y. Du
, et al. (25 additional authors not shown)
Abstract:
The Gravitational Wave highly energetic Electromagnetic Counterpart All-sky Monitor (GECAM) is dedicated to detecting gravitational wave gamma-ray bursts. It is capable of all-sky monitoring over and discovering gamma-ray bursts and new radiation phenomena. GECAM consists of two microsatellites, each equipped with 8 charged particle detectors (CPDs) and 25 gamma-ray detectors (GRDs). The CPD is us…
▽ More
The Gravitational Wave highly energetic Electromagnetic Counterpart All-sky Monitor (GECAM) is dedicated to detecting gravitational wave gamma-ray bursts. It is capable of all-sky monitoring over and discovering gamma-ray bursts and new radiation phenomena. GECAM consists of two microsatellites, each equipped with 8 charged particle detectors (CPDs) and 25 gamma-ray detectors (GRDs). The CPD is used to measure charged particles in the space environment, monitor energy and flow intensity changes, and identify between gamma-ray bursts and space charged particle events in conjunction with GRD. CPD uses plastic scintillator as the sensitive material for detection, silicon photomultiplier (SiPM) array as the optically readable device, and the inlaid Am-241 radioactive source as the onboard calibration means. In this paper, we will present the working principle, physical design, functional implementation and preliminary performance test results of the CPD.
△ Less
Submitted 9 December, 2021;
originally announced December 2021.
-
Inflight performance of the GECAM Gamma-ray and Charge particle Detectors
Authors:
X. Q. Li,
X. Y. Wen,
S. L. Xiong,
K. Gong,
D. L. Zhang,
Z. H. An,
Y. B. Xu,
Y. Q. Liu,
C. Cai,
Z. Chang,
G. Chen,
C. Chen,
Y. Y. Du,
M. Gao,
R. Gao,
D. Y. Guo,
J. J. He,
D. J. Hou,
Y. G. Li,
C. Li,
C. Y. Li,
G. Li,
L. Li,
Q. X. Li,
X. F. Li
, et al. (34 additional authors not shown)
Abstract:
The GECAM mission consists of two identical microsatellites (GECAM-A and GECAM-B). Each satellite is equipped with 25 gamma-ray detectors (GRD) and 8 charged particle detectors (CPD). The main scientific objective of the GECAM mission is to detect gamma-ray bursts (GRBs) associated with the gravitational wave events produced by the merging of binary compact stars. After the launch on Dec. 10, 2020…
▽ More
The GECAM mission consists of two identical microsatellites (GECAM-A and GECAM-B). Each satellite is equipped with 25 gamma-ray detectors (GRD) and 8 charged particle detectors (CPD). The main scientific objective of the GECAM mission is to detect gamma-ray bursts (GRBs) associated with the gravitational wave events produced by the merging of binary compact stars. After the launch on Dec. 10, 2020 , we carried out a series of on orbit tests. This paper introduces the test results of the GECAM-B satellite. According to the in-flight performance, the energy band for gamma-ray detection of GECAM-B is from about 7 keV to 3.5 MeV. GECAM-B can achieve prompt localization of GRBs. For the first time, GECAM-B realized a quasi-real-time transmission of trigger information using Beidou-3 RDSS. Keywords GECAM, gamma-ray burst, gravitational wave, GRD, CPD
△ Less
Submitted 9 December, 2021;
originally announced December 2021.
-
Quality assurance test and Failure Analysis of SiPM Arrays of GECAM Satellites
Authors:
D. L. Zhang,
M. Gao,
X. L. Sun,
X. Q. Li,
Z. H. An,
X. Y. Wen,
C. Cai,
Z. Chang,
G. Chen,
C. Chen,
Y. Y. Du,
R. Gao,
K. Gong,
D. Y. Guo,
J. J. He,
D. J. Hou,
Y. G. Li,
C. Y. Li,
G. Li,
L. Li,
X. F. Li,
M. S. Li,
X. H. Liang,
X. J. Liu,
Y. Q. Liu
, et al. (23 additional authors not shown)
Abstract:
The Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) satellite consists of two small satellites. Each GECAM payload contains 25 gamma ray detectors (GRD) and 8 charged particle detectors (CPD). GRD is the main detector which can detect gamma-rays and particles and localize the Gamma-Ray Bursts (GRB),while CPD is used to help GRD to discriminate gamma-ray bursts an…
▽ More
The Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) satellite consists of two small satellites. Each GECAM payload contains 25 gamma ray detectors (GRD) and 8 charged particle detectors (CPD). GRD is the main detector which can detect gamma-rays and particles and localize the Gamma-Ray Bursts (GRB),while CPD is used to help GRD to discriminate gamma-ray bursts and charged particle bursts. The GRD makes use of lanthanum bromide (LaBr3) crystal readout by SiPM. As the all available SiPM devices belong to commercial grade, quality assurance tests need to be performed in accordance with the aerospace specifications. In this paper, we present the results of quality assurance tests, especially a detailed mechanism analysis of failed devices during the development of GECAM. This paper also summarizes the application experience of commercial-grade SiPM devices in aerospace payloads, and provides suggestions for forthcoming SiPM space applications.
△ Less
Submitted 9 December, 2021; v1 submitted 1 September, 2021;
originally announced September 2021.
-
Benchmarking calculations with spectroscopic accuracy of level energies and wavelengths in W LVII - W LXII tungsten ions
Authors:
Chun Yu Zhang,
Kai Wang,
Ran Si,
Michel Godefroid,
Per Jönsson,
Jun Xiao,
Ming Feng Gu,
Chong Yang Chen
Abstract:
Atomic properties of $n=3$ states of the W$^{56+}$ $-$ W$^{61+}$ ions are systematically investigated through two state-of-the-art methods, namely, the second-order many-body perturbation theory, and the multi-configuration Dirac-Hartree-Fock method combined with the relativistic configuration interaction approach. The contributions of valence-valence and core-valence electron correlations, the Br…
▽ More
Atomic properties of $n=3$ states of the W$^{56+}$ $-$ W$^{61+}$ ions are systematically investigated through two state-of-the-art methods, namely, the second-order many-body perturbation theory, and the multi-configuration Dirac-Hartree-Fock method combined with the relativistic configuration interaction approach. The contributions of valence-valence and core-valence electron correlations, the Breit interaction, the higher-order retardation correction beyond the Breit interaction through the transverse photon interaction, and the quantum electrodynamical corrections to the excitation energies are studied in detail. The excitation energies and wavelengths obtained with the two methods agree with each other within \approx 0.01 %. The present results achieve spectroscopic accuracy and provide a benchmark test for various applications and other theoretical calculations of W$^{56+}$ $-$ W$^{61+}$ ions. They will assist spectroscopists in their assignment and direct identification of observed lines in complex spectra.
△ Less
Submitted 16 March, 2021;
originally announced March 2021.
-
Extended calculations of energy levels, radiative properties, and lifetimes for P-like Ge XVIII
Authors:
Kai Wanga,
Xiao Han Zhang,
Chun Yu Zhang,
Wei Dang,
Xiao Hui Zhao,
Zhan Bin Chen,
Ran Si,
Chong Yang Chen,
Jun Yan
Abstract:
Using the multiconfiguration Dirac-Hartree-Fock (MCDHF) and the relativistic configuration interaction (RCI) methods, a consistent set of transition energies and radiative transition data for the lowest 150 states of the $3s^2 3p^3$, $3s 3p^4$, $3s^2 3p^2 3d$, $3s 3p^3 3d$, $3p^5$, and $3s^2 3p 3d^2$ configurations in P-like Ge XVIII is provided. To assess the accuracy of the MCDHF transition ener…
▽ More
Using the multiconfiguration Dirac-Hartree-Fock (MCDHF) and the relativistic configuration interaction (RCI) methods, a consistent set of transition energies and radiative transition data for the lowest 150 states of the $3s^2 3p^3$, $3s 3p^4$, $3s^2 3p^2 3d$, $3s 3p^3 3d$, $3p^5$, and $3s^2 3p 3d^2$ configurations in P-like Ge XVIII is provided. To assess the accuracy of the MCDHF transition energies, we have also performed calculations using the many-body perturbation theory (MBPT). Comparisons are made between the present MCDHF and MBPT data sets, as well as with other available experimental and theoretical values. The resulting accurate and consistent MCDHF data set will be useful for line identification and modeling purposes. These data can be considered as a benchmark for other calculations.
△ Less
Submitted 4 January, 2021;
originally announced January 2021.
-
Extended Calculations with Spectroscopic Accuracy: Energy Levels and Radiative Rates for O-like Ions between Ar XI and Cr XVII
Authors:
C. X. Song,
C. Y. Zhang,
K. Wang,
R. Si,
M. Godefroid,
P. Jönsson,
D. Wei,
X. H. Zhao,
J. Yan,
C. Y. Chen
Abstract:
Using the multiconfiguration Dirac-Hartree-Fock and the relativistic configuration interaction methods, a consistent set of transition energies and radiative transition data for the main states of the $2s^2 2p^4$, $2s 2p^5$, $2p^6$, $2s^2 2p^3 3s$, $2s^2 2p^3 3p$, $2s^2 2p^3 3d$, $2s 2p^4 3s$, $2s 2p^4 3p$, and $2s 2p^4 3d$ configurations in O-like Ions between Ar XI ($Z = 18$) and Cr XVII (…
▽ More
Using the multiconfiguration Dirac-Hartree-Fock and the relativistic configuration interaction methods, a consistent set of transition energies and radiative transition data for the main states of the $2s^2 2p^4$, $2s 2p^5$, $2p^6$, $2s^2 2p^3 3s$, $2s^2 2p^3 3p$, $2s^2 2p^3 3d$, $2s 2p^4 3s$, $2s 2p^4 3p$, and $2s 2p^4 3d$ configurations in O-like Ions between Ar XI ($Z = 18$) and Cr XVII ($Z = 24$) is provided. Our data set is compared with the NIST compiled values and previous calculations. The data are accurate enough for identification and deblending of new emission lines from hot astrophysical and laboratory plasmas. The amount of data of high accuracy is significantly increased for the $n = 3$ states of several O-like ions, where experimental data are very scarce.
△ Less
Submitted 6 August, 2020;
originally announced August 2020.
-
Benchmarking calculations with spectroscopic accuracy of excitation energies and wavelengths in sulfur-like tungsten
Authors:
Chun Yu Zhang,
Kai Wang,
Michel Godefroid,
Per Jönsson,
Ran Si,
Chong Yang Chen
Abstract:
Atomic properties of S-like W are evaluated through a state-of-the-art method, namely, the multi-configuration Dirac-Hartree-Fock (MCDHF) method combined with the relativistic configuration interaction (RCI) approach. The level energies, wavelengths, and transition parameters involving the 88 lowest levels of W$^{+58}$ (W LIX) are calculated. We discuss in detail the relative importance of the val…
▽ More
Atomic properties of S-like W are evaluated through a state-of-the-art method, namely, the multi-configuration Dirac-Hartree-Fock (MCDHF) method combined with the relativistic configuration interaction (RCI) approach. The level energies, wavelengths, and transition parameters involving the 88 lowest levels of W$^{+58}$ (W LIX) are calculated. We discuss in detail the relative importance of the valence- and core-valence electron correlation effects, the Breit interaction, the higher order retardation correction beyond the Breit interaction through the transverse photon interaction, and the quantum electrodynamical (QED) corrections. The present level energies are highly accurate, with uncertainties close to what can be achieved from spectroscopy. As such, they provide benchmark tests for other theoretical calculations of S-like W and should assist the spectroscopists in their assignment/identification of observed lines in complex spectra.
△ Less
Submitted 25 February, 2020;
originally announced February 2020.
-
Extended calculations of energy levels, radiative properties, $A_{J}$, $B_{J}$ hyperfine interaction constants, and Landé $g_{J}$-factors for nitrogen-like \mbox{Ge XXVI}
Authors:
K. Wang,
C. Y. Zhang,
P. Jönsson,
R. Si,
X. H. Zhao,
Z. B. Chen,
X. L. Guo,
C. Y. Chen,
J. Yan
Abstract:
Employing two state-of-the-art methods, multiconfiguration Dirac--Hartree--Fock and second-order many-body perturbation theory, highly accurate calculations are performed for the lowest 272 fine-structure levels arising from the $2s^{2} 2p^{3}$, $2s 2p^{4}$, $2p^{5}$, $2s^{2} 2p^{2} 3l$~($l=s,p,d$), $2s 2p^{3}3l$ ($l=s,p,d$), and $2p^{4} 3l$ ($l=s,p,d$) configurations in nitrogen-like Ge XXVI. Com…
▽ More
Employing two state-of-the-art methods, multiconfiguration Dirac--Hartree--Fock and second-order many-body perturbation theory, highly accurate calculations are performed for the lowest 272 fine-structure levels arising from the $2s^{2} 2p^{3}$, $2s 2p^{4}$, $2p^{5}$, $2s^{2} 2p^{2} 3l$~($l=s,p,d$), $2s 2p^{3}3l$ ($l=s,p,d$), and $2p^{4} 3l$ ($l=s,p,d$) configurations in nitrogen-like Ge XXVI. Complete and consistent atomic data, including excitation energies, lifetimes, wavelengths, hyperfine structures, Landé $g_{J}$-factors, and E1, E2, M1, M2 line strengths, oscillator strengths, and transition rates among these 272 levels are provided. Comparisons are made between the present two data sets, as well as with other available experimental and theoretical values. The present data are accurate enough for identification and deblending of emission lines involving the $n=3$ levels, and are also useful for modeling and diagnosing fusion plasmas.
△ Less
Submitted 11 January, 2018;
originally announced January 2018.
-
Benchmarking Atomic Data for Astrophysics: Be-like Ions between B II and Ne VII
Authors:
Kai Wang,
Zhan Bin Chen,
Chun Yu Zhang,
Ran Si,
Per Jönsson,
Henrik Hartman,
Ming Feng Gu,
Chong Yang Chen,
Jun Yan
Abstract:
Large-scale self-consistent multiconfiguration Dirac--Hartree--Fock and relativistic configuration interaction calculations are reported for the $n \leq 6$ levels in Be-like ions from B II to Ne VII. Effects from electron correlation are taken into account by means of large expansions in terms of a basis of configuration state functions, and a complete and accurate data set of excitation energies,…
▽ More
Large-scale self-consistent multiconfiguration Dirac--Hartree--Fock and relativistic configuration interaction calculations are reported for the $n \leq 6$ levels in Be-like ions from B II to Ne VII. Effects from electron correlation are taken into account by means of large expansions in terms of a basis of configuration state functions, and a complete and accurate data set of excitation energies, lifetimes, wavelengths, and electric dipole, magnetic dipole, electric quadrupole, and magnetic quadrupole line strengths, transition rates, and oscillator strengths for these levels is provided for each ion. Comparisons are made with available experimental and theoretical results. The uncertainty of excitation energies is assessed to be 0.01\% on average, which makes it possible to find and rule out misidentifications and aid new line identifications involving high-lying levels in astrophysical spectra. The complete data set is also useful for modeling and diagnosing astrophysical plasmas.
△ Less
Submitted 21 December, 2017;
originally announced December 2017.