-
The P$^3$ Experiment: A Positron Source Demonstrator for Future Lepton Colliders
Authors:
Nicolas Vallis,
Paolo Craievich,
Mattia Schär,
Riccardo Zennaro,
Bernard Auchmann,
Hans-Heinrich Braun,
Maria Ilaria Besana,
Michal Duda,
Reto Fortunati,
Henrique Garcia Rodrigues,
Dominique Hauenstein,
Rasmus Ischebeck Rasmus,
Pavle Juranić,
Jaap Kosse,
Fabio Marcellini,
Thomas Uli Michlmayr,
Stefan Müller,
Marco Pedrozzi,
Renzo Rotundo,
Gian Luca Orlandi,
Mike Seidel,
Nick Parsifal Strohmaier,
Mariia Zykova
Abstract:
The PSI Positron Production (P$^3$ or P-cubed) experiment is a demonstrator for a e+ source and capture system with potential to improve the state-of-the-art e+ yield by an order of magnitude. The experiment is driven by the FCC-ee injector study and will be hosted in the SwissFEL facility at the Paul Scherrer Institute in Switzerland. This paper is an overview of the P$^3$ design at an advanced s…
▽ More
The PSI Positron Production (P$^3$ or P-cubed) experiment is a demonstrator for a e+ source and capture system with potential to improve the state-of-the-art e+ yield by an order of magnitude. The experiment is driven by the FCC-ee injector study and will be hosted in the SwissFEL facility at the Paul Scherrer Institute in Switzerland. This paper is an overview of the P$^3$ design at an advanced stage, with a particular emphasis on a novel e+ capture system and its associated beam dynamics. Additionally, a concept for the experiment diagnostics is presented, as well as the key points of the ongoing installation works.
△ Less
Submitted 1 September, 2023; v1 submitted 31 August, 2023;
originally announced August 2023.
-
The Compact Linear Collider (CLIC) - 2018 Summary Report
Authors:
The CLIC,
CLICdp collaborations,
:,
T. K. Charles,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
M. Volpi,
C. Balazs,
K. Afanaciev,
V. Makarenko,
A. Patapenka,
I. Zhuk,
C. Collette,
M. J. Boland,
A. C. Abusleme Hoffman,
M. A. Diaz,
F. Garay,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu,
X. Wang,
J. Zhang
, et al. (671 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the…
▽ More
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the detector. CLIC is foreseen to be built and operated in stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. CLIC uses a two-beam acceleration scheme, in which 12 GHz accelerating structures are powered via a high-current drive beam. For the first stage, an alternative with X-band klystron powering is also considered. CLIC accelerator optimisation, technical developments and system tests have resulted in an increased energy efficiency (power around 170 MW) for the 380 GeV stage, together with a reduced cost estimate at the level of 6 billion CHF. The detector concept has been refined using improved software tools. Significant progress has been made on detector technology developments for the tracking and calorimetry systems. A wide range of CLIC physics studies has been conducted, both through full detector simulations and parametric studies, together providing a broad overview of the CLIC physics potential. Each of the three energy stages adds cornerstones of the full CLIC physics programme, such as Higgs width and couplings, top-quark properties, Higgs self-coupling, direct searches, and many precision electroweak measurements. The interpretation of the combined results gives crucial and accurate insight into new physics, largely complementary to LHC and HL-LHC. The construction of the first CLIC energy stage could start by 2026. First beams would be available by 2035, marking the beginning of a broad CLIC physics programme spanning 25-30 years.
△ Less
Submitted 6 May, 2019; v1 submitted 14 December, 2018;
originally announced December 2018.
-
Updated baseline for a staged Compact Linear Collider
Authors:
The CLIC,
CLICdp collaborations,
:,
M. J. Boland,
U. Felzmann,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
C. Balazs,
T. K. Charles,
K. Afanaciev,
I. Emeliantchik,
A. Ignatenko,
V. Makarenko,
N. Shumeiko,
A. Patapenka,
I. Zhuk,
A. C. Abusleme Hoffman,
M. A. Diaz Gutierrez,
M. Vogel Gonzalez,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu
, et al. (493 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-q…
▽ More
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-quark measurements. Subsequent stages will focus on measurements of rare Higgs processes, as well as searches for new physics processes and precision measurements of new states, e.g. states previously discovered at LHC or at CLIC itself. In the 2012 CLIC Conceptual Design Report, a fully optimised 3 TeV collider was presented, while the proposed lower energy stages were not studied to the same level of detail. This report presents an updated baseline staging scenario for CLIC. The scenario is the result of a comprehensive study addressing the performance, cost and power of the CLIC accelerator complex as a function of centre-of-mass energy and it targets optimal physics output based on the current physics landscape. The optimised staging scenario foresees three main centre-of-mass energy stages at 380 GeV, 1.5 TeV and 3 TeV for a full CLIC programme spanning 22 years. For the first stage, an alternative to the CLIC drive beam scheme is presented in which the main linac power is produced using X-band klystrons.
△ Less
Submitted 27 March, 2017; v1 submitted 26 August, 2016;
originally announced August 2016.
-
Commissioning experience and beam physics measurements at the SwissFEL Injector Test Facility
Authors:
T. Schietinger,
M. Pedrozzi,
M. Aiba,
V. Arsov,
S. Bettoni,
B. Beutner,
M. Calvi,
P. Craievich,
M. Dehler,
F. Frei,
R. Ganter,
C. P. Hauri,
R. Ischebeck,
Y. Ivanisenko,
M. Janousch,
M. Kaiser,
B. Keil,
F. Löhl,
G. L. Orlandi,
C. Ozkan Loch,
P. Peier,
E. Prat,
J. -Y. Raguin,
S. Reiche,
T. Schilcher
, et al. (70 additional authors not shown)
Abstract:
The SwissFEL Injector Test Facility operated at the Paul Scherrer Institute between 2010 and 2014, serving as a pilot plant and testbed for the development and realization of SwissFEL, the X-ray Free-Electron Laser facility under construction at the same institute. The test facility consisted of a laser-driven rf electron gun followed by an S-band booster linac, a magnetic bunch compression chican…
▽ More
The SwissFEL Injector Test Facility operated at the Paul Scherrer Institute between 2010 and 2014, serving as a pilot plant and testbed for the development and realization of SwissFEL, the X-ray Free-Electron Laser facility under construction at the same institute. The test facility consisted of a laser-driven rf electron gun followed by an S-band booster linac, a magnetic bunch compression chicane and a diagnostic section including a transverse deflecting rf cavity. It delivered electron bunches of up to 200 pC charge and up to 250 MeV beam energy at a repetition rate of 10 Hz. The measurements performed at the test facility not only demonstrated the beam parameters required to drive the first stage of an FEL facility, but also led to significant advances in instrumentation technologies, beam characterization methods and the generation, transport and compression of ultra-low-emittance beams. We give a comprehensive overview of the commissioning experience of the principal subsystems and the beam physics measurements performed during the operation of the test facility, including the results of the test of an in-vacuum undulator prototype generating radiation in the vacuum ultraviolet and optical range.
△ Less
Submitted 27 October, 2016; v1 submitted 8 June, 2016;
originally announced June 2016.
-
Dark Current Studies for SwissFEL
Authors:
F. Le Pimpec,
R. Zennaro,
S. Reiche,
E. Hohmann,
A. Citterio,
A. Adelmann,
B. Grigoryan
Abstract:
Activation of the surroundings of an accelerator must be quantified and those data provided to the official agencies. This is a necessary step in obtaining the authorization to operate such an accelerator. SwissFEL, being a fourth generation light source, will produce more accelerated charges, which are dumped or lost, than conventional third generation light source, such as the Swiss Light Source…
▽ More
Activation of the surroundings of an accelerator must be quantified and those data provided to the official agencies. This is a necessary step in obtaining the authorization to operate such an accelerator. SwissFEL, being a fourth generation light source, will produce more accelerated charges, which are dumped or lost, than conventional third generation light source, such as the Swiss Light Source. We have simulated the propagation of a dark current beam produced in the photoelectron gun using tracking codes like ASTRA and Elegant for the current layout of SwissFEL. Experimental studies have been carried out at the SwissFEL test facilities at PSI (C-Band RF Stand and SwissFEL Injector Test Facility), in order to provide necessary input data for detailed study of components (RF gun and C-band RF structures) using the simulation code OPAL. A summary of these studies are presented.
△ Less
Submitted 10 August, 2012; v1 submitted 14 May, 2012;
originally announced May 2012.
-
Recent Progress on a Manifold Damped and Detuned Structure for CLIC
Authors:
V. F. Khan,
A. D'Elia,
A. Grudiev,
R. M. Jones,
W. Wuensch,
R. Zennaro
Abstract:
A damped detuned structure for the main X-band linacs of CLIC is being investigated as an alternative design to the present baseline heavily damped structure. In our earlier designs we studied detuned structures, operating at 11.994 GHz, with a range of dipole bandwidths in order to ensure the structure satisfies beam dynamics and rf breakdown constraints. Here we report on the development of a da…
▽ More
A damped detuned structure for the main X-band linacs of CLIC is being investigated as an alternative design to the present baseline heavily damped structure. In our earlier designs we studied detuned structures, operating at 11.994 GHz, with a range of dipole bandwidths in order to ensure the structure satisfies beam dynamics and rf breakdown constraints. Here we report on the development of a damped and detuned structure which satisfies both constraints. Preparations for high power testing of the structure are also discussed
△ Less
Submitted 1 June, 2010;
originally announced June 2010.
-
Cyclinacs: Fast-Cycling Accelerators for Hadrontherapy
Authors:
U. Amaldi,
S. Braccini,
A. Citterio,
K. Crandall,
M. Crescenti,
M. Dominietto,
A. Giuliacci,
G. Magrin,
C. Mellace,
P. Pearce,
G. Pitta',
E. Rosso,
M. Weiss,
R. Zennaro
Abstract:
We propose an innovative fast-cycling accelerator complex conceived and designed to exploit at best the properties of accelerated ion beams for hadrontherapy. A cyclinac is composed by a cyclotron, which can be used also for other valuable medical and research purposes, followed by a high gradient linear accelerator capable to produce ion beams optimized for the irradiation of solid tumours with…
▽ More
We propose an innovative fast-cycling accelerator complex conceived and designed to exploit at best the properties of accelerated ion beams for hadrontherapy. A cyclinac is composed by a cyclotron, which can be used also for other valuable medical and research purposes, followed by a high gradient linear accelerator capable to produce ion beams optimized for the irradiation of solid tumours with the most modern techniques. The properties of cyclinacs together with design studies for protons and carbon ions are presented and the advantages in facing the challenges of hadrontherapy are discussed.
△ Less
Submitted 20 February, 2009;
originally announced February 2009.
-
CLUSTER: a high frequency H-mode coupled cavity linac for low and medium energies
Authors:
Ugo Amaldi,
Alessandro Citterio,
Massimo Crescenti,
Arianna Giuliacci,
Cesare Tronci,
Riccardo Zennaro
Abstract:
We propose an innovative linear accelerating structure, particularly suited for hadrontherapy applications. Its two main features are compactness and good power efficiency at low beam velocities: the first is achieved through a high working frequency and a consequent high accelerating gradient, the second is obtained by coupling several H-mode cavities together. The structure is called CLUSTER,…
▽ More
We propose an innovative linear accelerating structure, particularly suited for hadrontherapy applications. Its two main features are compactness and good power efficiency at low beam velocities: the first is achieved through a high working frequency and a consequent high accelerating gradient, the second is obtained by coupling several H-mode cavities together. The structure is called CLUSTER, which stands for "Coupled-cavity Linac USing Transverse Electric Radial field". In order to compare the performance of this structure with other hadrontherapy linac designs involving high frequencies, a conceptual study has been performed for an operating frequency of 3 GHz. Moreover a proof of principle has been obtained through RF measurements on a prototype operating at 1 GHz. An accelerator complex using a CLUSTER linac is also considered for protontherapy purposes. The whole complex is called cyclinac and is composed of a commercial cyclotron injecting the beam in a high-frequency linac.
△ Less
Submitted 21 December, 2006;
originally announced December 2006.