-
Ultracold Neutron Properties of the Eljen-299-02D deuterated scintillator
Authors:
Z. Tang,
E. B. Watkins,
S. M. Clayton,
S. A. Currie,
D. E. Fellers,
Md. T. Hassan,
D. E. Hooks,
T. M. Ito,
S. K. Lawrence,
S. W. T. MacDonald,
M. Makela,
C. L. Morris,
L. P. Neukirch,
A. Saunders,
C. M. O'Shaughnessy,
C. Cude-Woods,
J. H. Choi,
A. R. Young,
B. A. Zeck,
F. Gonzalez,
C. Y. Liu,
N. C. Floyd,
K. P. Hickerson,
A. T. Holley,
B. A. Johnson
, et al. (2 additional authors not shown)
Abstract:
In this paper we report studies of the Fermi potential and loss per bounce of ultracold neutron (UCN) on a deuterated scintillator (Eljen-299-02D). These UCN properties of the scintillator enables a wide variety of applications in fundamental neutron research.
In this paper we report studies of the Fermi potential and loss per bounce of ultracold neutron (UCN) on a deuterated scintillator (Eljen-299-02D). These UCN properties of the scintillator enables a wide variety of applications in fundamental neutron research.
△ Less
Submitted 25 September, 2020;
originally announced September 2020.
-
Final results for the neutron $β$-asymmetry parameter $A_0$ from the UCNA experiment
Authors:
B. Plaster,
E. Adamek,
B. Allgeier,
J. Anaya,
H. O. Back,
Y. Bagdasarova,
D. B. Berguno,
M. Blatnik,
J. G. Boissevain,
T. J. Bowles,
L. J. Broussard,
M. A. -P. Brown,
R. Carr,
D. J. Clark,
S. Clayton,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
S. Du,
B. W. Filippone,
A. Garcia,
P. Geltenbort,
S. Hasan,
A. Hawari
, et al. (69 additional authors not shown)
Abstract:
The UCNA experiment was designed to measure the neutron $β$-asymmetry parameter $A_0$ using polarized ultracold neutrons (UCN). UCN produced via downscattering in solid deuterium were polarized via transport through a 7 T magnetic field, and then directed to a 1 T solenoidal electron spectrometer, where the decay electrons were detected in electron detector packages located on the two ends of the…
▽ More
The UCNA experiment was designed to measure the neutron $β$-asymmetry parameter $A_0$ using polarized ultracold neutrons (UCN). UCN produced via downscattering in solid deuterium were polarized via transport through a 7 T magnetic field, and then directed to a 1 T solenoidal electron spectrometer, where the decay electrons were detected in electron detector packages located on the two ends of the spectrometer. A value for $A_0$ was then extracted from the asymmetry in the numbers of counts in the two detector packages. We summarize all of the results from the UCNA experiment, obtained during run periods in 2007, 2008--2009, 2010, and 2011--2013, which ultimately culminated in a 0.67\% precision result for $A_0$.
△ Less
Submitted 10 April, 2019;
originally announced April 2019.
-
A boron-coated CCD camera for direct detection of Ultracold Neutrons (UCN)
Authors:
K. Kuk,
C. Cude-Woods,
C. R. Chavez,
J. H. Choi,
J. Estrada,
M. Hoffbauer,
M. Makela,
P. Merkel,
C. L. Morris,
E. Ramberg,
Z. Wang,
T. Bailey,
M. Blatnik,
E. R. Adamek,
L. J. Broussard,
M. A. -P. Brown,
N. B. Callahan,
S. M. Clayton,
S. A. Currie,
X. Ding,
D. Dinger,
B. Filippone,
E. M. Fries,
P. Geltenbort,
E. George
, et al. (26 additional authors not shown)
Abstract:
A new boron-coated CCD camera is described for direct detection of ultracold neutrons (UCN) through the capture reactions $^{10}$B (n,$α$0$γ$)$^7$Li (6%) and $^{10}$B(n,$α$1$γ$)$^7$Li (94%). The experiments, which extend earlier works using a boron-coated ZnS:Ag scintillator, are based on direct detections of the neutron-capture byproducts in silicon. The high position resolution, energy resolutio…
▽ More
A new boron-coated CCD camera is described for direct detection of ultracold neutrons (UCN) through the capture reactions $^{10}$B (n,$α$0$γ$)$^7$Li (6%) and $^{10}$B(n,$α$1$γ$)$^7$Li (94%). The experiments, which extend earlier works using a boron-coated ZnS:Ag scintillator, are based on direct detections of the neutron-capture byproducts in silicon. The high position resolution, energy resolution and particle ID performance of a scientific CCD allows for observation and identification of all the byproducts $α$, $^7$Li and $γ$ (electron recoils). A signal-to-noise improvement on the order of 10$^4$ over the indirect method has been achieved. Sub-pixel position resolution of a few microns is demonstrated. The technology can also be used to build UCN detectors with an area on the order of 1 m$^2$. The combination of micrometer scale spatial resolution, few electrons ionization thresholds and large area paves the way to new research avenues including quantum physics of UCN and high-resolution neutron imaging and spectroscopy.
△ Less
Submitted 28 February, 2019;
originally announced March 2019.
-
Using Nab to determine correlations in unpolarized neutron decay
Authors:
L. J. Broussard,
S. Baeßler,
T. L. Bailey,
N. Birge,
J. D. Bowman,
C. B. Crawford,
C. Cude-Woods,
D. E. Fellers,
N. Fomin,
E. Frlež,
M. T. W. Gericke,
L. Hayen,
A. P. Jezghani,
H. Li,
N. Macsai,
M. F. Makela,
R. R. Mammei,
D. Mathews,
P. L. McGaughey,
P. E. Mueller,
D. Počanić,
C. A. Royse,
A. Salas-Bacci,
S. K. L. Sjue,
J. C. Ramsey
, et al. (6 additional authors not shown)
Abstract:
The Nab experiment will measure the ratio of the weak axial-vector and vector coupling constants $λ=g_A/g_V$ with precision $δλ/λ\sim3\times10^{-4}$ and search for a Fierz term $b_F$ at a level $Δb_F<10^{-3}$. The Nab detection system uses thick, large area, segmented silicon detectors to very precisely determine the decay proton's time of flight and the decay electron's energy in coincidence and…
▽ More
The Nab experiment will measure the ratio of the weak axial-vector and vector coupling constants $λ=g_A/g_V$ with precision $δλ/λ\sim3\times10^{-4}$ and search for a Fierz term $b_F$ at a level $Δb_F<10^{-3}$. The Nab detection system uses thick, large area, segmented silicon detectors to very precisely determine the decay proton's time of flight and the decay electron's energy in coincidence and reconstruct the correlation between the antineutrino and electron momenta. Excellent understanding of systematic effects affecting timing and energy reconstruction using this detection system are required. To explore these effects, a series of ex situ studies have been undertaken, including a search for a Fierz term at a less sensitive level of $Δb_F<10^{-2}$ in the beta decay of $^{45}$Ca using the UCNA spectrometer.
△ Less
Submitted 19 December, 2018;
originally announced December 2018.
-
Monte Carlo Simulations of Trapped Ultracold Neutrons in the UCNτ Experiment
Authors:
Nathan Callahan,
Chen-Yu Liu,
Francisco Gonzalez,
Evan Adamek,
James David Bowman,
Leah Broussard,
S. M. Clayton,
S. Currie,
C. Cude-Woods,
E. B. Dees,
X. Ding,
E. M. Egnel,
D. Fellers,
W. Fox,
P. Geltenbort,
K. P. Hickerson,
M. A. Hoffbauer,
A. T. Holley,
A. Komives,
S. W. T. MacDonald,
M. Makela,
C. L. Morris,
J. D. Ortiz,
R. W. Pattie Jr,
J. Ramsey
, et al. (15 additional authors not shown)
Abstract:
In the UCNτ experiment, ultracold neutrons (UCN) are confined by magnetic fields and the Earth's gravitational field. Field-trap** mitigates the problem of UCN loss on material surfaces, which caused the largest correction in prior neutron experiments using material bottles. However, the neutron dynamics in field traps differ qualitatively from those in material bottles. In the latter case, neut…
▽ More
In the UCNτ experiment, ultracold neutrons (UCN) are confined by magnetic fields and the Earth's gravitational field. Field-trap** mitigates the problem of UCN loss on material surfaces, which caused the largest correction in prior neutron experiments using material bottles. However, the neutron dynamics in field traps differ qualitatively from those in material bottles. In the latter case, neutrons bounce off material surfaces with significant diffusivity and the population quickly reaches a static spatial distribution with a density gradient induced by the gravitational potential. In contrast, the field-confined UCN -- whose dynamics can be described by Hamiltonian mechanics -- do not exhibit the stochastic behaviors typical of an ideal gas model as observed in material bottles. In this report, we will describe our efforts to simulate UCN trap** in the UCNτ magneto-gravitational trap. We compare the simulation output to the experimental results to determine the parameters of the neutron detector and the input neutron distribution. The tuned model is then used to understand the phase space evolution of neutrons observed in the UCNτ experiment. We will discuss the implications of chaotic dynamics on controlling the systematic effects, such as spectral cleaning and microphonic heating, for a successful UCN lifetime experiment to reach a 0.01% level of precision.
△ Less
Submitted 16 October, 2018;
originally announced October 2018.
-
Search for dark matter decay of the free neutron from the UCNA experiment: n $\rightarrow χ+ e^+e^-$
Authors:
X. Sun,
E. Adamek,
B. Allgeier,
M. Blatnik,
T. J. Bowles,
L. J. Broussard,
M. A. -P. Brown,
R. Carr,
S. Clayton,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
B. W. Filippone,
A. García,
P. Geltenbort,
S. Hasan,
K. P. Hickerson,
J. Hoagland,
R. Hong,
G. E. Hogan,
A. T. Holley,
T. M. Ito,
A. Knecht,
C. -Y. Liu
, et al. (35 additional authors not shown)
Abstract:
It has been proposed recently that a previously unobserved neutron decay branch to a dark matter particle ($χ$) could account for the discrepancy in the neutron lifetime observed in experiments that use two different measurement techniques. One of the possible final states discussed includes a single $χ$ along with an $e^{+}e^{-}$ pair. We use data from the UCNA (Ultracold Neutron Asymmetry) exper…
▽ More
It has been proposed recently that a previously unobserved neutron decay branch to a dark matter particle ($χ$) could account for the discrepancy in the neutron lifetime observed in experiments that use two different measurement techniques. One of the possible final states discussed includes a single $χ$ along with an $e^{+}e^{-}$ pair. We use data from the UCNA (Ultracold Neutron Asymmetry) experiment to set limits on this decay channel. Coincident electron-like events are detected with $\sim 4π$ acceptance using a pair of detectors that observe a volume of stored Ultracold Neutrons (UCNs). The summed kinetic energy ($E_{e^{+}e^{-}}$) from such events is used to set limits, as a function of the $χ$ mass, on the branching fraction for this decay channel. For $χ$ masses consistent with resolving the neutron lifetime discrepancy, we exclude this as the dominant dark matter decay channel at $\gg~5σ$ level for $100~\text{keV} < E_{e^{+}e^{-}} < 644~\text{keV}$. If the $χ+e^{+}e^{-}$ final state is not the only one, we set limits on its branching fraction of $< 10^{-4}$ for the above $E_{e^{+}e^{-}}$ range at $> 90\%$ confidence level.
△ Less
Submitted 28 March, 2018;
originally announced March 2018.
-
Evaluation of commercial nickel-phosphorus coating for ultracold neutron guides using a pinhole bottling method
Authors:
R. W. Pattie Jr,
E. Adamek,
T. Brenner,
A. Brandt,
L. J. Broussard,
N. B. Callahan,
S. M. Clayton,
C. Cude-Woods,
S. A. Currie,
P. Geltonbort,
T. Ito,
T. Lauer,
C. Y. Liu,
J. Majewski,
M. Makela,
Y. Masuda,
C. L. Morris,
J. C. Ramsey,
D. Salvat,
A. Saunders,
J. Schroffenegger,
Z. Tang,
W. Wei,
Z. Wang,
E. Watkins
, et al. (2 additional authors not shown)
Abstract:
We report on the evaluation of commercial electroless nickel phosphorus (NiP) coatings for ultracold neutron (UCN) transport and storage. The material potential of 50~$μ$m thick NiP coatings on stainless steel and aluminum substrates was measured to be $V_F = 213(5.2)$~neV using the time-of-flight spectrometer ASTERIX at the Lujan Center. The loss per bounce probability was measured in pinhole bot…
▽ More
We report on the evaluation of commercial electroless nickel phosphorus (NiP) coatings for ultracold neutron (UCN) transport and storage. The material potential of 50~$μ$m thick NiP coatings on stainless steel and aluminum substrates was measured to be $V_F = 213(5.2)$~neV using the time-of-flight spectrometer ASTERIX at the Lujan Center. The loss per bounce probability was measured in pinhole bottling experiments carried out at ultracold neutron sources at Los Alamos Neutron Science Center and the Institut Laue-Langevin. For these tests a new guide coupling design was used to minimize gaps between the guide sections. The observed UCN loss in the bottle was interpreted in terms of an energy independent effective loss per bounce, which is the appropriate model when gaps in the system and upscattering are the dominate loss mechanisms, yielding a loss per bounce of $1.3(1) \times 10^{-4}$. We also present a detailed discussion of the pinhole bottling methodology and an energy dependent analysis of the experimental results.
△ Less
Submitted 1 March, 2017;
originally announced March 2017.
-
A new method for measuring the neutron lifetime using an in situ neutron detector
Authors:
C. L. Morris,
E. R. Adamek,
L. J. Broussard,
N. B. Callahan,
S. M. Clayton,
C. Cude-Woods,
S. A. Currie,
X. Ding,
W. Fox,
K. P. Hickerson,
A. T. Holley,
A. Komives,
C. -Y. Liu,
M. Makela,
R. W. Pattie Jr.,
J. Ramsey,
D. J. Salvat,
A. Saunders,
S. J. Seestrom,
E. I. Sharapov,
S. K. Sjue,
Z. Tang,
J. Vanderwerp,
B. Vogelaar,
P. L. Walstrom
, et al. (6 additional authors not shown)
Abstract:
The neutron lifetime is important in understanding the production of light nuclei in the first minutes after the big bang and it provides basic information on the charged weak current of the standard model of particle physics. Two different methods have been used to measure the neutron lifetime: disappearance measurements using bottled ultracold neutrons and decay rate measurements using neutron b…
▽ More
The neutron lifetime is important in understanding the production of light nuclei in the first minutes after the big bang and it provides basic information on the charged weak current of the standard model of particle physics. Two different methods have been used to measure the neutron lifetime: disappearance measurements using bottled ultracold neutrons and decay rate measurements using neutron beams. The best measurements using these two techniques give results that differ by nearly 4 standard deviations. In this paper we describe a new method for measuring surviving neutrons in neutron lifetime measurements using bottled ultracold neutrons that provides better characterization of systematic uncertainties and enables higher precision than previous measurement techniques. We present results obtained using our method.
△ Less
Submitted 14 October, 2016;
originally announced October 2016.
-
Detection System for Neutron $β$ Decay Correlations in the UCNB and Nab experiments
Authors:
L. J. Broussard,
B. A. Zeck,
E. R. Adamek,
S. Baeßler,
N. Birge,
M. Blatnik,
J. D. Bowman,
A. E. Brandt,
M. Brown,
J. Burkhart,
N. B. Callahan,
S. M. Clayton,
C. Crawford,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
N. Fomin,
E. Frlez,
J. Fry,
F. E. Gray,
S. Hasan,
K. P. Hickerson,
J. Hoagland,
A. T. Holley
, et al. (29 additional authors not shown)
Abstract:
We describe a detection system designed for precise measurements of angular correlations in neutron $β$ decay. The system is based on thick, large area, highly segmented silicon detectors developed in collaboration with Micron Semiconductor, Ltd. The prototype system meets specifications for $β$ electron detection with energy thresholds below 10 keV, energy resolution of $\sim$3 keV FWHM, and rise…
▽ More
We describe a detection system designed for precise measurements of angular correlations in neutron $β$ decay. The system is based on thick, large area, highly segmented silicon detectors developed in collaboration with Micron Semiconductor, Ltd. The prototype system meets specifications for $β$ electron detection with energy thresholds below 10 keV, energy resolution of $\sim$3 keV FWHM, and rise time of $\sim$50 ns with 19 of the 127 detector pixels instrumented. Using ultracold neutrons at the Los Alamos Neutron Science Center, we have demonstrated the coincident detection of $β$ particles and recoil protons from neutron $β$ decay. The fully instrumented detection system will be implemented in the UCNB and Nab experiments, to determine the neutron $β$ decay parameters $B$, $a$, and $b$.
△ Less
Submitted 7 January, 2017; v1 submitted 9 July, 2016;
originally announced July 2016.
-
Position-sensitive detection of ultracold neutrons with an imaging camera and its implications to spectroscopy
Authors:
Wanchun Wei,
L. J. Broussard,
M. A. Hoffbauer,
M. Makela,
C. L. Morris,
Z. Tang,
E. R. Adamek,
N. B. Callahan,
S. M. Clayton,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
P. Geltenbort,
K. P. Hickerson,
A. T. Holley,
T. M. Ito,
K. K. Leung,
C. -Y. Liu,
D. J. Morley,
Jose D. Ortiz,
R. W. Pattie, Jr.,
J. C. Ramsey,
A. Saunders,
S. J. Seestrom
, et al. (7 additional authors not shown)
Abstract:
Position-sensitive detection of ultracold neutrons (UCNs) is demonstrated using an imaging charge-coupled device (CCD) camera. A spatial resolution less than 15 $μ$m has been achieved, which is equivalent to an UCN energy resolution below 2 pico-electron-volts through the relation $δE = m_0g δx$. Here, the symbols $δE$, $δx$, $m_0$ and $g$ are the energy resolution, the spatial resolution, the neu…
▽ More
Position-sensitive detection of ultracold neutrons (UCNs) is demonstrated using an imaging charge-coupled device (CCD) camera. A spatial resolution less than 15 $μ$m has been achieved, which is equivalent to an UCN energy resolution below 2 pico-electron-volts through the relation $δE = m_0g δx$. Here, the symbols $δE$, $δx$, $m_0$ and $g$ are the energy resolution, the spatial resolution, the neutron rest mass and the gravitational acceleration, respectively. A multilayer surface convertor described previously is used to capture UCNs and then emits visible light for CCD imaging. Particle identification and noise rejection are discussed through the use of light intensity profile analysis. This method allows different types of UCN spectroscopy and other applications.
△ Less
Submitted 12 May, 2016; v1 submitted 27 April, 2016;
originally announced April 2016.
-
A multilayer surface detector for ultracold neutrons
Authors:
Zhehui Wang,
M. A. Hoffbauer,
C. L. Morris,
N. B. Callahan,
E. R. Adamek,
J. D. Bacon,
M. Blatnik,
A. E. Brandt,
L. J. Broussard,
S. M. Clayton,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
J. Gao,
F. E. Gray,
K. P. Hickerson,
A. T. Holley,
T. M. Ito,
C. -Y. Liu,
M. Makela,
J. C. Ramsey,
R. W. Pattie, Jr.,
D. J. Salvat,
A. Saunders
, et al. (11 additional authors not shown)
Abstract:
A multilayer surface detector for ultracold neutrons (UCNs) is described. The top $^{10}$B layer is exposed to the vacuum chamber and directly captures UCNs. The ZnS:Ag layer beneath the $^{10}$B layer is a few microns thick, which is sufficient to detect the charged particles from the $^{10}$B(n,$α$)$^7$Li neutron-capture reaction, while thin enough so that ample light due to $α$ and $^7$Li escap…
▽ More
A multilayer surface detector for ultracold neutrons (UCNs) is described. The top $^{10}$B layer is exposed to the vacuum chamber and directly captures UCNs. The ZnS:Ag layer beneath the $^{10}$B layer is a few microns thick, which is sufficient to detect the charged particles from the $^{10}$B(n,$α$)$^7$Li neutron-capture reaction, while thin enough so that ample light due to $α$ and $^7$Li escapes for detection by photomultiplier tubes. One-hundred-nm thick $^{10}$B layer gives high UCN detection efficiency, as determined by the mean UCN kinetic energy, detector materials and others. Low background, including negligible sensitivity to ambient neutrons, has also been verified through pulse-shape analysis and comparisons with other existing $^3$He and $^{10}$B detectors. This type of detector has been configured in different ways for UCN flux monitoring, development of UCN guides and neutron lifetime research.
△ Less
Submitted 24 April, 2015; v1 submitted 11 March, 2015;
originally announced March 2015.
-
Radial distribution of charged particles in a magnetic field
Authors:
S. K. L. Sjue,
L. Broussard,
M. Makela,
P. L. McGaughey,
A. R. Young,
B. A. Zeck
Abstract:
The radial spread of charged particles emitted from a point source in a magnetic field is a potential source of systematic error for any experiment where magnetic fields guide charged particles to detectors with finite size. Assuming uniform probability as a function of the phase along the particle's helical trajectory, an analytic solution for the radial probability distribution function follows…
▽ More
The radial spread of charged particles emitted from a point source in a magnetic field is a potential source of systematic error for any experiment where magnetic fields guide charged particles to detectors with finite size. Assuming uniform probability as a function of the phase along the particle's helical trajectory, an analytic solution for the radial probability distribution function follows which applies to experiments in which particles are generated throughout a volume that spans a sufficient length along the axis of a homogeneous magnetic field. This approach leads to the same result as a different derivation given by Dubbers et al. But the constant phase approximation does not strictly apply to finite source volumes or fixed positions, which lead to local maxima in the radial distribution of emitted particles at the plane of the detector. A simple method is given to calculate such distributions, then the effect is demonstrated with data from a $^{207}$Bi electron-conversion source in the superconducting solenoid magnet spectrometer of the Ultracold Neutron facility at the Los Alamos Neutron Science Center. Potential future applications of this effect are discussed.
△ Less
Submitted 23 June, 2014;
originally announced June 2014.