-
Performance of 20:1 multiplexer for large area charge readouts in directional dark matter TPC detectors
Authors:
A. C. Ezeribe,
M. Robinson,
N. Robinson,
A. Scarff,
N. J. C. Spooner,
L. Yuriev
Abstract:
More target mass is required in current TPC based directional dark matter detectors for improved detector sensitivity. This can be achieved by scaling up the detector volumes, but this results in the need for more analogue signal channels. A possible solution to reducing the overall cost of the charge readout electronics is to multiplex the signal readout channels. Here, we present a multiplexer s…
▽ More
More target mass is required in current TPC based directional dark matter detectors for improved detector sensitivity. This can be achieved by scaling up the detector volumes, but this results in the need for more analogue signal channels. A possible solution to reducing the overall cost of the charge readout electronics is to multiplex the signal readout channels. Here, we present a multiplexer system in expanded mode based on LMH6574 chips produced by Texas Instruments, originally designed for video processing. The setup has a capability of reducing the number of readouts in such TPC detectors by a factor of 20. Results indicate that the important charge distribution asymmetry along an ionization track is retained after multiplexed signals are demultiplexed.
△ Less
Submitted 12 March, 2018; v1 submitted 2 November, 2017;
originally announced November 2017.
-
First background-free limit from a directional dark matter experiment: results from a fully fiducialised DRIFT detector
Authors:
J. B. R. Battat,
J. Brack,
E. Daw,
A. Dorofeev,
A. C. Ezeribe,
J. -L. Gauvreau,
M. Gold,
J. L. Harton,
J. M. Landers,
E. Law,
E. R. Lee,
D. Loomba,
A. Lumnah,
J. A. J. Matthews,
E. H. Miller,
A. Monte,
F. Mouton,
A. StJ. Murphy,
S. M. Paling,
N. Phan,
M. Robinson,
S. W. Sadler,
A. Scarff,
F. Schuckman,
D. P. Snowden-Ifft
, et al. (6 additional authors not shown)
Abstract:
The addition of O2 to gas mixtures in time projection chambers containing CS2 has recently been shown to produce multiple negative ions that travel at slightly different velocities. This allows a measurement of the absolute position of ionising events in the z (drift) direction. In this work, we apply the z-fiducialisation technique to a directional dark matter search. In particular, we present re…
▽ More
The addition of O2 to gas mixtures in time projection chambers containing CS2 has recently been shown to produce multiple negative ions that travel at slightly different velocities. This allows a measurement of the absolute position of ionising events in the z (drift) direction. In this work, we apply the z-fiducialisation technique to a directional dark matter search. In particular, we present results from a 46.3 live-day source-free exposure of the DRIFT-IId detector run in this completely new mode. With full-volume fiducialisation, we have achieved the first background-free operation of a directional detector. The resulting exclusion curve for spin-dependent WIMP-proton interactions reaches 1.1 pb at 100 GeV/c2, a factor of 2 better than our previous work. We describe the automated analysis used here, and argue that detector upgrades, implemented after the acquisition of these data, will bring an additional factor of >3 improvement in the near future.
△ Less
Submitted 23 July, 2015; v1 submitted 28 October, 2014;
originally announced October 2014.
-
Radon in the DRIFT-II directional dark matter TPC: emanation, detection and mitigation
Authors:
J. B. R. Battat,
J. Brack,
E. Daw,
A. Dorofeev,
A. C. Ezeribe,
J. R. Fox,
J. -L. Gauvreau,
M. Gold,
L. J. Harmon,
J. L. Harton,
J. M. Landers,
E. R. Lee,
D. Loomba,
J. A. J. Matthews,
E. H. Miller,
A. Monte,
A. StJ. Murphy,
S. M. Paling,
N. Phan,
M. Pipe,
M. Robinson,
S. W. Sadler,
A. Scarff,
D. P. Snowden-Ifft,
N. J. C. Spooner
, et al. (4 additional authors not shown)
Abstract:
Radon gas emanating from materials is of interest in environmental science and also a major concern in rare event non-accelerator particle physics experiments such as dark matter and double beta decay searches, where it is a major source of background. Notable for dark matter experiments is the production of radon progeny recoils (RPRs), the low energy (~100 keV) recoils of radon daughter isotopes…
▽ More
Radon gas emanating from materials is of interest in environmental science and also a major concern in rare event non-accelerator particle physics experiments such as dark matter and double beta decay searches, where it is a major source of background. Notable for dark matter experiments is the production of radon progeny recoils (RPRs), the low energy (~100 keV) recoils of radon daughter isotopes, which can mimic the signal expected from WIMP interactions. Presented here are results of measurements of radon emanation from detector materials in the 1 metre cubed DRIFT-II directional dark matter gas time projection chamber experiment. Construction and operation of a radon emanation facility for this work is described, along with an analysis to continuously monitor DRIFT data for the presence of internal 222Rn and 218Po. Applying this analysis to historical DRIFT data, we show how systematic substitution of detector materials for alternatives, selected by this device for low radon emanation, has resulted in a factor of ~10 reduction in internal radon rates. Levels are found to be consistent with the sum from separate radon emanation measurements of the internal materials and also with direct measurement using an attached alpha spectrometer. The current DRIFT detector, DRIFT-IId, is found to have sensitivity to 222Rn of 2.5 μBq/l with current analysis efficiency, potentially opening up DRIFT technology as a new tool for sensitive radon assay of materials.
△ Less
Submitted 25 August, 2014; v1 submitted 15 July, 2014;
originally announced July 2014.
-
Background Assay and Rejection in DRIFT
Authors:
Jeff Brack,
Ed Daw,
Alexei Dorofeev,
Anthony Ezeribe,
Jean-Luc Gauvreau,
Michael Gold,
John Harton,
Randy Lafler,
Robert Lauer,
Eric R. Lee,
Dinesh Loomba,
John Matthews,
Eric H. Miller,
Alissa Monte,
Alex Murphy,
Sean Paling,
Nguyen Phan,
Steve Sadler,
Andrew Scarff,
Daniel Snowden-Ifft,
Neil Spooner,
Sam Telfer,
Daniel Walker,
Matt Williams,
Leonid Yuriev
Abstract:
The DRIFT-IId dark matter detector is a m$^3$-scale low-pressure TPC with directional sensitivity to WIMP-induced nuclear recoils. Its primary backgrounds were due to alpha decays from contamination on the central cathode. Efforts to reduce these backgrounds led to replacing the 20 μm wire central cathode with one constructed from 0.9 μm aluminized mylar, which is almost totally transparent to alp…
▽ More
The DRIFT-IId dark matter detector is a m$^3$-scale low-pressure TPC with directional sensitivity to WIMP-induced nuclear recoils. Its primary backgrounds were due to alpha decays from contamination on the central cathode. Efforts to reduce these backgrounds led to replacing the 20 μm wire central cathode with one constructed from 0.9 μm aluminized mylar, which is almost totally transparent to alpha particles. Detailed modeling of the nature and origin of the remaining backgrounds led to an in-situ, ppt-sensitive assay of alpha decay backgrounds from the central cathode. This led to further improvements in the thin-film cathode resulting in over 2 orders of magnitude reduction in backgrounds compared to the wire cathode. Finally, the addition of O$_2$ to CS$_2$ gas was found to produce multiple species of electronegative charge carriers, providing a method to determine the absolute position of nuclear recoils and reject all known remaining backgrounds while retaining a high efficiency for nuclear recoil detection.
△ Less
Submitted 8 April, 2014;
originally announced April 2014.
-
Long-term study of backgrounds in the DRIFT-II directional dark matter experiment
Authors:
J. Brack,
E. Daw,
A. Dorofeev,
A. C. Ezeribe,
J. R. Fox,
J. -L. Gauvreau,
M. Gold,
L. J. Harmon,
J. Harton,
R. Lafler,
J. M. Landers,
R. Lauer,
E. R. Lee,
D. Loomba,
J. A. J. Matthews,
E. H. Miller,
A. Monte,
A. StJ. Murphy,
S. M. Paling,
N. Phan,
M. Pipe,
M. Robinson,
S. Sadler,
A. Scarff,
D. P. Snowden-Ifft
, et al. (4 additional authors not shown)
Abstract:
Low-pressure gas Time Projection Chambers being developed for directional dark matter searches offer a technology with strong particle identification capability combined with the potential to produce a definitive detection of Galactic Weakly Interacting Massive Particle (WIMP) dark matter. A source of events able to mimic genuine WIMP-induced nuclear recoil tracks arises in such experiments from t…
▽ More
Low-pressure gas Time Projection Chambers being developed for directional dark matter searches offer a technology with strong particle identification capability combined with the potential to produce a definitive detection of Galactic Weakly Interacting Massive Particle (WIMP) dark matter. A source of events able to mimic genuine WIMP-induced nuclear recoil tracks arises in such experiments from the decay of radon gas inside the vacuum vessel. The recoils that result from associated daughter nuclei are termed Radon Progeny Recoils (RPRs). We present here experimental data from a long-term study using the DRIFT-II directional dark matter experiment at the Boulby Underground Laboratory of the RPRs, and other backgrounds that are revealed by relaxing the normal cuts that are applied to WIMP search data. By detailed examination of event classes in both spatial and time coordinates using 5.5 years of data, we demonstrate the ability to determine the origin of 4 specific background populations and describe development of new technology and mitigation strategies to suppress them.
△ Less
Submitted 12 May, 2014; v1 submitted 21 July, 2013;
originally announced July 2013.