-
Experimental research on the THGEM-based thermal neutron detector
Authors:
Yang Lei,
Zhou Jian-Rong,
Sun Zhi-Jia,
Zhang Ying,
Huang Chao-Qiang,
Sun Guang-Ai,
Wang Yan-Feng,
Yang Gui-An,
Xu Hong,
Xie Yu-Guang,
Chen Yuan-Bo
Abstract:
A new thermal neutron detector with the domestically produced THGEM (THick Gas Electron Multiplier) was developed as an alternative to 3He to meet the needs of the next generation of neutron facilities. One type of Au-coated THGEM was designed specifically for the neutron detection. A detector prototype had been developed and the preliminary experimental tests were presented, including the perform…
▽ More
A new thermal neutron detector with the domestically produced THGEM (THick Gas Electron Multiplier) was developed as an alternative to 3He to meet the needs of the next generation of neutron facilities. One type of Au-coated THGEM was designed specifically for the neutron detection. A detector prototype had been developed and the preliminary experimental tests were presented, including the performance of the Au-coated THGEM working in the Ar/CO2 gas mixtures and the neutron imaging test with 252CF source, which would provide the reference of experimental data for the research in future.
△ Less
Submitted 5 August, 2014;
originally announced August 2014.
-
Beam test of a one-dimensional position sensitive chamber on synchrotron radiation
Authors:
Liu Mei,
Dai Hong-Liang,
Qi Hui-Rong,
Zhuang Bao-An,
Zhang Jian,
Liu Rong-Guang,
Zhu Qi-Ming,
Ouyang Qun,
Chen Yuan-Bo,
Jiang Xiao-Shan,
Wang Ya-Jie,
Liu Peng,
Chang Guang-Cai
Abstract:
One-dimensional single-wire chamber was developed to provide high position resolution for powder diffraction experiments with synchrotron radiation. A diffraction test using the sample of SiO2 has been accomplished at 1W2B laboratory of Bei**g Synchrotron Radiation Source. The data of beam test were analyzed and some diffraction angles were obtained. The experimental results were in good agreemen…
▽ More
One-dimensional single-wire chamber was developed to provide high position resolution for powder diffraction experiments with synchrotron radiation. A diffraction test using the sample of SiO2 has been accomplished at 1W2B laboratory of Bei**g Synchrotron Radiation Source. The data of beam test were analyzed and some diffraction angles were obtained. The experimental results were in good agreement with standard data from ICDD powder diffraction file. The precision of diffraction angles was 1% to 4.7%. Most of relative errors between measured values of diffraction angles and existing data were less than 1%. As for the detector, the best position resolution in the test was 138 um (sigma value) with an X-ray tube. Finally, discussions of the results were given. The major factor that affected the precision of measurement was deviation from the flat structure of detector. The effect was analyzed and it came to a conclusion that it would be the optimal measurement scheme when the distance between the powder sample and detector was from 400 mm to 600 mm.
△ Less
Submitted 25 May, 2013;
originally announced May 2013.
-
The Reconstruction Algorithm Study of 2D Interpolating Resistive Readout Structure
Authors:
Xiu Qing-Lei,
Dong Ming-Yi,
Liu Rong-Guang,
Zhang Jian,
Ou-Yang Qun,
Chen Yuan-Bo
Abstract:
Systematic investigations including both simulation and prototype tests have been done about the interpolating resistive readout structure with GEM (Gaseous Electron Multiplier) detector. From the simulation, we have a good knowledge of the process of charges diffusion on the surface of the readout plane and develop several reconstruction methods to determine the hit position. The total signal dur…
▽ More
Systematic investigations including both simulation and prototype tests have been done about the interpolating resistive readout structure with GEM (Gaseous Electron Multiplier) detector. From the simulation, we have a good knowledge of the process of charges diffusion on the surface of the readout plane and develop several reconstruction methods to determine the hit position. The total signal duration time of a typical event with the readout structure is about several hundred nanoseconds, which implied an ideal count rate up to 106Hz. A stable worked prototype was designed and fabricated after the simulation. Using 55Fe 5.9keV X-Ray, the image performance of the prototype is examined with flat field image and some special geometry shapes, meanwhile, an energy resolution of about 17% is obtained.
△ Less
Submitted 5 December, 2012;
originally announced December 2012.