-
Combination of crystal growth with optical floating zone and evaluation of Nd3+:LaAlO3 crystals with the dynamic nuclear polarization of 139La and 27Al
Authors:
Kohei Ishizaki,
Ikuo Ide,
Masaki Fujita,
Hiroki Hotta,
Yuki Ito,
Masataka Iinuma,
Yoichi Ikeda,
Takahiro Iwata,
Masaaki Kitaguchi,
Hideki Kohri,
Taku Matsushita,
Daisuke Miura,
Yoshiyuki Miyachi,
Hirohiko M. Shimizu,
Masaru Yosoi
Abstract:
Producing a polarized lanthanum (La) target with high polarization and long relaxation time is crucial for realizing time-reversal violation experiments using polarized neutron beams. We use a LaAlO3 crystal doped with a small amount of Nd3+ ions for the polarized lanthanum target. Optimizing the amount of Nd3+ ions is considerably important because the achievable polarization and relaxation time…
▽ More
Producing a polarized lanthanum (La) target with high polarization and long relaxation time is crucial for realizing time-reversal violation experiments using polarized neutron beams. We use a LaAlO3 crystal doped with a small amount of Nd3+ ions for the polarized lanthanum target. Optimizing the amount of Nd3+ ions is considerably important because the achievable polarization and relaxation time strongly depend on this amount. We established a fundamental method to grow single crystals of Nd3+:LaAlO3 using an optical floating zone method that employs halogen lamps and evaluated the crystals with the dynamic nuclear polarization (DNP) method for polarizing nuclear spins. Two crystal samples were grown by ourselves and evaluated with the DNP at 1.3 K and 2.3 T for the first time except for the target materials of protons. The enhancement of NMR signals for 139La and 27Al was successfully observed, and the enhancement factors were eventually 3.5+-0.3 and 13+-3 for the samples with Nd3+ ions of 0.05 and 0.01 mol%, respectively. These enhancement factors correspond to absolute vector polarizations of 0.27+-0.02% (Nd 0.05 mol%) and 1.4+-0.3% (Nd 0.01 mol%). Although the obtained polarizations are still low, they are acceptable as a first step. The combination scheme of the crystal growth and evaluation of the crystals is found to be effectively applicable for optimizing the amount of Nd3+ ions for improving the performance of the polarized target.
△ Less
Submitted 1 May, 2024; v1 submitted 11 February, 2024;
originally announced February 2024.
-
SPring-8 LEPS2 beamline: A facility to produce a multi-GeV photon beam via laser Compton scattering
Authors:
N. Muramatsu,
M. Yosoi,
T. Yorita,
Y. Ohashi,
J. K. Ahn,
S. Ajimura,
Y. Asano,
W. C. Chang,
J. Y. Chen,
S. Date,
T. Gogami,
H. Hamano,
T. Hashimoto,
T. Hiraiwa,
T. Hotta,
T. Ishikawa,
Y. Kasamatsu,
H. Katsuragawa,
R. Kobayakawa,
H. Kohri,
S. Masumoto,
Y. Matsumura,
M. Miyabe,
K. Mizutani,
Y. Morino
, et al. (26 additional authors not shown)
Abstract:
We have constructed a new laser-Compton-scattering facility, called the LEPS2 beamline, at the 8-GeV electron storage ring, SPring-8. This facility provides a linearly polarized photon beam in a tagged energy range of 1.3--2.4 GeV. Thanks to a small divergence of the low-emittance storage-ring electrons, the tagged photon beam has a size (sigma) suppressed to about 4 mm even after it travels about…
▽ More
We have constructed a new laser-Compton-scattering facility, called the LEPS2 beamline, at the 8-GeV electron storage ring, SPring-8. This facility provides a linearly polarized photon beam in a tagged energy range of 1.3--2.4 GeV. Thanks to a small divergence of the low-emittance storage-ring electrons, the tagged photon beam has a size (sigma) suppressed to about 4 mm even after it travels about 130 m to the experimental building that is independent of the storage ring building and contains large detector systems. This beamline is designed to achieve a photon beam intensity higher than that of the first laser-Compton-scattering beamline at SPring-8 by adopting the simultaneous injection of up to four high-power laser beams and increasing a transmittance for the long photon-beam path up to about 77%. The new beamline is under operation for hadron photoproduction experiments.
△ Less
Submitted 14 December, 2021;
originally announced December 2021.
-
Measurement of nuclear spin relaxation time in lanthanum aluminate for development of polarized lanthanum target
Authors:
K. Ishizaki,
H. Hotta,
I. Ide,
M. Iinuma,
T. Iwata,
M. Kitaguchi,
H. Kohri,
D. Miura,
Y. Miyachi,
T. Ohta,
H. M. Shimizu,
H. Yoshikawa,
M. Yosoi
Abstract:
The nuclear spin-lattice relaxation time ($T_1$) of lanthanum and aluminum nuclei in a single crystal of lanthanum aluminate doped with neodymium ions is studied to estimate the feasibility of the dynamically polarized lanthanum target applicable to beam experiments. The application of our interest is the study of fundamental discrete symmetries in the spin optics of epithermal neutrons. This stud…
▽ More
The nuclear spin-lattice relaxation time ($T_1$) of lanthanum and aluminum nuclei in a single crystal of lanthanum aluminate doped with neodymium ions is studied to estimate the feasibility of the dynamically polarized lanthanum target applicable to beam experiments. The application of our interest is the study of fundamental discrete symmetries in the spin optics of epithermal neutrons. This study requires a highly flexible choice of the applied magnetic field for neutron spin control and favors longer $T_1$ under lower magnetic field and at higher temperature. The $T_1$ of $^{139}{\rm La}$ and ${}^{27}{\rm Al}$ was measured under magnetic fields of $0.5$-$2.5$ T and at temperatures of $0.1$-$1.5$ K and found widely distributed up to 100 h. The result suggests that the $T_1$ can be as long as $T_1 \sim$ 1 h at $0.1$ K with a magnetic field of $0.1$ T, which partially fulfills the requirement of the neutron beam experiment. Possible improvements to achieve a longer $T_1$ are discussed.
△ Less
Submitted 16 September, 2021; v1 submitted 11 May, 2021;
originally announced May 2021.
-
Monitoring the build-up of hydrogen polarization for polarized Hydrogen-Deuteride (HD) targets with NMR at 17 Tesla
Authors:
T. Ohta,
M. Fujiwara,
T. Hotta,
I. Ide,
K. Ishizaki,
H. Kohri,
Y. Yanai,
M. Yosoi
Abstract:
We report on the frozen-spin polarized hydrogen--deuteride (HD) targets for photoproduction experiments at SPring-8/LEPS. Pure HD gas with a small amount of ortho-H2 (~0.1%) was liquefied and solidified by liquid helium. The temperature of the produced solid HD was reduced to about 30 mK with a dilution refrigerator. A magnetic field (17 T) was applied to the HD to grow the polarization with the s…
▽ More
We report on the frozen-spin polarized hydrogen--deuteride (HD) targets for photoproduction experiments at SPring-8/LEPS. Pure HD gas with a small amount of ortho-H2 (~0.1%) was liquefied and solidified by liquid helium. The temperature of the produced solid HD was reduced to about 30 mK with a dilution refrigerator. A magnetic field (17 T) was applied to the HD to grow the polarization with the static method. After the aging of the HD at low temperatures in the presence of a high-magnetic field strength for 3 months, the polarization froze. Almost all ortho-H2 molecules were converted to para-H2 molecules that exhibited weak spin interactions with the HD. If the concentration of the ortho-H2 was reduced at the beginning of the aging process, the aging time can be shortened. We have developed a new nuclear magnetic resonance (NMR) system to measure the relaxation times (T1) of the 1H and 2H nuclei with two frequency sweeps at the respective frequencies of 726 and 111 MHz, and succeeded in the monitoring of the polarization build-up at decreasing temperatures from 600 to 30 mK at 17 T. This technique enables us to optimize the concentration of the ortho-H2 and to efficiently polarize the HD target within a shortened aging time.
△ Less
Submitted 10 September, 2020; v1 submitted 17 February, 2020;
originally announced February 2020.
-
A compensated multi-gap RPC with 2 m-long strips for the LEPS2 experiment
Authors:
K. Watanabe,
S. Tanaka,
W. C. Chang,
H. Chen,
M. L. Chu,
J. J. Cuenca-Garcia,
T. Gogami,
D. Gonzalez-Diaz,
M. Niiyama,
Y. Ohashi,
H. Ohnishi,
N. Tomida,
M. Yosoi
Abstract:
We have developed multi-gap resistive plate chambers (MRPCs) with 2.5 x 200 cm2 readout strips for the time-of-flight (TOF) detector system of the LEPS2 experiment at SPring-8. These chambers consist of 2 stacks and 5 gas gaps per stack, in a mirrored configuration. A time resolution of sigma ~ 80 ps was achieved for any position within a strip (at above 99% detection efficiency); after performing…
▽ More
We have developed multi-gap resistive plate chambers (MRPCs) with 2.5 x 200 cm2 readout strips for the time-of-flight (TOF) detector system of the LEPS2 experiment at SPring-8. These chambers consist of 2 stacks and 5 gas gaps per stack, in a mirrored configuration. A time resolution of sigma ~ 80 ps was achieved for any position within a strip (at above 99% detection efficiency); after performing the time-charge slewing correction, this value could be reduced to 60 ps. A link between the small contribution of the slewing correction to timing and the suppression of modal dispersion in the detector could be established.
△ Less
Submitted 19 September, 2018; v1 submitted 18 September, 2018;
originally announced September 2018.
-
Development of High Intensity Laser-Electron Photon Beams up to 2.9 GeV at the SPring-8 LEPS Beamline
Authors:
N. Muramatsu,
Y. Kon,
S. Daté,
Y. Ohashi,
H. Akimune,
J. Y. Chen,
M. Fujiwara,
S. Hasegawa,
T. Hotta,
T. Ishikawa,
T. Iwata,
Y. Kato,
H. Kohri,
T. Matsumura,
T. Mibe,
Y. Miyachi,
Y. Morino,
T. Nakano,
Y. Nakatsugawa,
H. Ohkuma,
T. Ohta,
M. Oka,
T. Sawada,
A. Wakai,
K. Yonehara
, et al. (3 additional authors not shown)
Abstract:
A laser-Compton backscattering beam, which we call a `Laser-Electron Photon' beam, was upgraded at the LEPS beamline of SPring-8. We accomplished the gains in backscattered photon beam intensities by factors of 1.5--1.8 with the injection of two adjacent laser beams or a higher power laser beam into the storage ring. The maximum energy of the photon beam was also extended from 2.4 GeV to 2.9 GeV w…
▽ More
A laser-Compton backscattering beam, which we call a `Laser-Electron Photon' beam, was upgraded at the LEPS beamline of SPring-8. We accomplished the gains in backscattered photon beam intensities by factors of 1.5--1.8 with the injection of two adjacent laser beams or a higher power laser beam into the storage ring. The maximum energy of the photon beam was also extended from 2.4 GeV to 2.9 GeV with deep-ultraviolet lasers. The upgraded beams have been utilized for hadron photoproduction experiments at the LEPS beamline. Based on the developed methods, we plan the simultaneous injection of four high power laser beams at the LEPS2 beamline, which has been newly constructed at SPring-8. As a simulation result, we expect an order of magnitude higher intensities close to 10$^7$ sec$^{-1}$ and 10$^6$ sec$^{-1}$ for tagged photons up to 2.4 GeV and 2.9 GeV, respectively.
△ Less
Submitted 29 August, 2013;
originally announced August 2013.
-
Distillation of hydrogen isotopes for polarized HD target
Authors:
T. Ohta,
S. Bouchigny,
J. -P. Didelez,
M. Fujiwara,
K. Fukuda,
H. Kohri,
T. Kunimatsu,
C. Morisaki,
S. Ono,
G. Rouill',
M. Tanaka,
K. Ueda,
M. Uraki,
M. Utsuro,
S. Y. Wang,
M. Yosoi
Abstract:
We have developed a cryogenic distillation system to purify Hydrogen-Deuteride (HD) gas for a polarized HD target in LEPS experiments at SPring-8. A small amount of ortho-H$_2$ ($\sim$0.01%) in the HD gas plays an important role in efficiently polarizing the HD target. Since there are 1$\sim$5% impurities of H$_2$ and D$_2$ in commercially available HD gases, it is inevitable that the HD gas is pu…
▽ More
We have developed a cryogenic distillation system to purify Hydrogen-Deuteride (HD) gas for a polarized HD target in LEPS experiments at SPring-8. A small amount of ortho-H$_2$ ($\sim$0.01%) in the HD gas plays an important role in efficiently polarizing the HD target. Since there are 1$\sim$5% impurities of H$_2$ and D$_2$ in commercially available HD gases, it is inevitable that the HD gas is purified up to $\sim$99.99%. The distillation system has a cryogenic pot (17$\sim$21 K) containing many small stainless steel cells called Heli-pack. Commercial HD gas with an amount of 5.2 mol is fed into the pot. We carried out three distillation runs by changing temperatures (17.5 K and 20.5 K) and gas extraction speeds (1.3 ml/min and 5.2 ml/min). The extracted gas was analyzed by using a gas analyzer system combining a quadrupole mass spectrometer with a gas chromatograph. The HD gas of 1 mol with a purity better than 99.99% has been successfully obtained. The effective NTS (Number of Theoretical Stages), which is an indicator of the distillator performances, is obtained as 37.2$\pm$0.6. This value is in reasonable agreement with a designed value of 37.9. The HD target is expected to be efficiently polarized under a well-controlled condition by do** an optimal amount of ortho-H$_2$ to the purified HD gas.
△ Less
Submitted 12 December, 2011; v1 submitted 14 June, 2011;
originally announced June 2011.
-
Development of portable NMR polarimeter system for polarized HD target
Authors:
T. Ohta,
M. Fujiwara,
K. Fukuda,
H. Kohri,
T. Kunimatsu,
C. Morisaki,
S. Ono,
M. Tanaka,
K. Ueda,
M. Uraki,
M. Utsuro,
S. Y. Wang,
M. Yosoi
Abstract:
A portable NMR polarimeter system has been developed to measure the polarization of a polarized Hydrogen-Deuteride (HD) target for hadron photoproduction experiments at SPring-8. The polarized HD target is produced at the Research Center for Nuclear Physics (RCNP), Osaka university and is transported to SPring-8. The HD polarization should be monitored at both places. We have constructed the porta…
▽ More
A portable NMR polarimeter system has been developed to measure the polarization of a polarized Hydrogen-Deuteride (HD) target for hadron photoproduction experiments at SPring-8. The polarized HD target is produced at the Research Center for Nuclear Physics (RCNP), Osaka university and is transported to SPring-8. The HD polarization should be monitored at both places. We have constructed the portable NMR polarimeter system by replacing the devices in the conventional system with the software system with PCI eXtensions for Instrumentation (PXI). The weight of the NMR system is downsized from 80 kg to 7 kg, and the cost is reduced to 25%. We check the performance of the portable NMR polarimeter system. The signal-to-noise (S/N) ratio of the NMR signal for the portable system is about 50% of that for the conventional NMR system. This performance of the portable NMR system is proved to be compatible with the conventional NMR system for the polarization measurement.
△ Less
Submitted 9 March, 2011; v1 submitted 3 March, 2011;
originally announced March 2011.
-
Effects of radiation damage caused by proton irradiation on Multi-Pixel Photon Counters (MPPCs)
Authors:
T. Matsumura,
T. Matsubara,
T. Hiraiwa,
K. Horie,
M. Kuze,
K. Miyabayashi,
A. Okamura,
T. Sawada,
S. Shimizu,
T. Shinkawa,
T. Tsunemi,
M. Yosoi
Abstract:
We have investigated the effects caused by proton-induced radiation damage on Multi-Pixel Photon Counter (MPPC), a pixelized photon detector developed by Hamamatsu Photonics. The leakage current of irradiated MPPC samples linearly increases with total irradiated doses due to radiation damage, which is not completely recovered even after a year from the irradiation. No significant change has been o…
▽ More
We have investigated the effects caused by proton-induced radiation damage on Multi-Pixel Photon Counter (MPPC), a pixelized photon detector developed by Hamamatsu Photonics. The leakage current of irradiated MPPC samples linearly increases with total irradiated doses due to radiation damage, which is not completely recovered even after a year from the irradiation. No significant change has been observed in the gains at least up to 8.0 Gy ($9.1\times10^7$ n/mm$^2$ in 1 MeV neutron equivalent fluence, $Φ_{\rm eq}$). The device has completely lost its photon-counting capability due to baseline fluctuations and noise pile-up after 21 Gy irradiation ($2.4\times10^8$ n/mm$^2$ in $Φ_{\rm eq}$), which might be problematic for some applications, such as ring-imaging Cherenkov detectors. We have found that the pulse-height resolution has been slightly deteriorated after 42 Gy irradiation ($4.8\times10^8$ n/mm$^2$ in $Φ_{\rm eq}$), where the measured sample has been illuminated with a few hundred photons. This effect should be considered in the case of energy-measurement applications.
△ Less
Submitted 29 September, 2014; v1 submitted 16 January, 2009;
originally announced January 2009.