-
Laser-scanning optical-frequency-comb microscopy for multimodal imaging
Authors:
Shimpei Kajiwara,
Eiji Hase,
Shota Nakano,
Keishiro Ootani,
Tomoya Okabe,
Hidenori Koresawa,
Akifumi Asahara,
Kazumichi Yoshii,
Hirotsugu Yamamoto,
Kaoru Minoshima,
Takeshi Yasui,
Takeo Minamikawa
Abstract:
We introduce a novel laser-scanning optical microscopy technique that employs optical-frequency-comb (OFC) lasers. This method facilitates multimodal spectroscopic imaging by analyzing interferograms produced via a dual-comb spectroscopic approach. Such interferograms capture comprehensive light information, including amplitude, phase, polarization, frequency, and time of flight information, enabl…
▽ More
We introduce a novel laser-scanning optical microscopy technique that employs optical-frequency-comb (OFC) lasers. This method facilitates multimodal spectroscopic imaging by analyzing interferograms produced via a dual-comb spectroscopic approach. Such interferograms capture comprehensive light information, including amplitude, phase, polarization, frequency, and time of flight information, enabling multimodal imaging from a single measurement. We demonstrate the potential of this technique across several spectroscopic imaging applications.
△ Less
Submitted 28 May, 2024;
originally announced May 2024.
-
Pattern transition of flow dynamics in a highly water-absorbent granular bed
Authors:
Kojiro Otoguro,
Kiwamu Yoshii,
Yutaka Sumino
Abstract:
An aqueous sodium chloride solution was injected at a controlled rate into a granular bed in a quasi-two-dimensional cell. The granular bed was made of dried, highly water-absorbent gel particles whose swelling rate was controlled by the salinity of the injected fluid. At a high salinity level (low swelling rate), high injection rate, and short timescale, the injected fluid percolated between the…
▽ More
An aqueous sodium chloride solution was injected at a controlled rate into a granular bed in a quasi-two-dimensional cell. The granular bed was made of dried, highly water-absorbent gel particles whose swelling rate was controlled by the salinity of the injected fluid. At a high salinity level (low swelling rate), high injection rate, and short timescale, the injected fluid percolated between the gel particles in an isotropic manner. Meanwhile, at a low salinity level (high swelling rate), low injection rate, and long timescale, the gel particles clogged the flow path, resulting in anisotropic branch-like structures of the injected fluid front. The transition of the injection pattern could be understood based on the ratio of the characteristic timescales of swelling and injection. Moreover, the clogged pattern showed an oscillatory pressure drop whose amplitude was increased with higher salinity. Such an oscillatory behavior observed in an injection process in a swelling gel particle may be relevant in geological situation; i.e., such as fluid migration underground.
△ Less
Submitted 29 January, 2024;
originally announced January 2024.
-
A lightweight, user-configurable detector ASIC digital architecture with on-chip data compression for MHz X-ray coherent diffraction imaging
Authors:
Sebastian Strempfer,
Tao Zhou,
Kazutomo Yoshii,
Mike Hammer,
Anakha Babu,
Dawid Bycul,
John Weizeorick,
Mathew J. Cherukara,
Antonino Miceli
Abstract:
Today, most X-ray pixel detectors used at light sources transmit raw pixel data off the detector ASIC. With the availability of more advanced ASIC technology nodes for scientific application, more digital functionality from the computing domains (e.g., compression) can be integrated directly into a detector ASIC to increase data velocity. In this paper, we describe a lightweight, user-configurable…
▽ More
Today, most X-ray pixel detectors used at light sources transmit raw pixel data off the detector ASIC. With the availability of more advanced ASIC technology nodes for scientific application, more digital functionality from the computing domains (e.g., compression) can be integrated directly into a detector ASIC to increase data velocity. In this paper, we describe a lightweight, user-configurable detector ASIC digital architecture with on-chip compression which can be implemented in \SI{130}{\nm} technologies in a reasonable area on the ASIC periphery. In addition, we present a design to efficiently handle the variable data from the stream of parallel compressors. The architecture includes user-selectable lossy and lossless compression blocks. The impact of lossy compression algorithms is evaluated on simulated and experimental X-ray ptychography datasets. This architecture is a practical approach to increase pixel detector frame rates towards the continuous \SI{1}{\MHz} regime for not only coherent imaging techniques such as ptychography, but also for other diffraction techniques at X-ray light sources.
△ Less
Submitted 29 July, 2022;
originally announced August 2022.
-
Pushing compute and AI onto detector silicon
Authors:
Antonino Miceli,
Kazutomo Yoshii,
Ian T. Foster
Abstract:
In order to take full advantage of the U.S. Department of Energy's billion-dollar investments into the next-generation research infrastructure (e.g., exascale, light sources, colliders), advances are required not only in detector technology but also in computing and specifically AI. Let us consider an example from X-ray science. Nanoscale X-ray imaging is a crucial tool to enable a wide range of s…
▽ More
In order to take full advantage of the U.S. Department of Energy's billion-dollar investments into the next-generation research infrastructure (e.g., exascale, light sources, colliders), advances are required not only in detector technology but also in computing and specifically AI. Let us consider an example from X-ray science. Nanoscale X-ray imaging is a crucial tool to enable a wide range of scientific explorations from materials science and biology to mechanical and civil engineering. The next-generation light sources will increase the X-ray beam brightness and coherent flux by 100 to 1,000 times. In order to image larger samples, the continuous frame rate of pixel array detectors must be increased, approaching 1 MHz, which requires several Tbps (aggregated) to transfer pixel data out to a data acquisition system. Using 65-nm CMOS technology, an optimistic raw data rate off such a chip is about 100-200 Gbps. However, a continuous 1 MHz detector with only $256 \times 256$ pixels at 16-bit resolution, for example, will require 1,000 Gbps (i.e., 1 Tbps) bandwidth off the chip! It is impractical to have multiple high-speed transceivers running in parallel to provide such bandwidth and represents the first data bottleneck. New approaches are necessary to reduce the data size by performing data compression or AI-based feature extraction directly inside a detector silicon chip in a streaming manner before sending it off-chip.
△ Less
Submitted 21 May, 2022;
originally announced May 2022.
-
Sulfonylamide-Based Ionic Liquids for High-Voltage Potassium-Ion Batteries with Honeycomb Layered Cathode Oxides
Authors:
Kazuki Yoshii,
Titus Masese,
Minami Kato,
Keigo Kubota,
Hiroshi Senoh,
Masahiro Shikano
Abstract:
The world is at the cusp of a new era where pivotal importance is being attached to the development of sustainable and high-performance energy storage systems. Potassium-ion batteries are deemed not only as cheap battery candidates, but also as the penultimate high-voltage energy storage systems within the monovalent-cation chemistries. However, their performance and sustainability are undermined…
▽ More
The world is at the cusp of a new era where pivotal importance is being attached to the development of sustainable and high-performance energy storage systems. Potassium-ion batteries are deemed not only as cheap battery candidates, but also as the penultimate high-voltage energy storage systems within the monovalent-cation chemistries. However, their performance and sustainability are undermined by the lack of suitable electrolytes for high-voltage operation particularly due to the limited availability of cathode materials. Here, the potential of ionic liquids based on potassium bis(trifluoromethanesulfonyl)amide (KTFSA) as high-voltage electrolytes is presented by assessing their physicochemical properties, along with the electrochemical properties upon coupling with new high-voltage layered cathode materials. These ionic liquids demonstrate a lower redox potential for potassium dissolution / deposition (with a wide voltage tolerance of around $6.0$ $\rm V$), placing them as feasible and safe electrolytes for high-voltage potassium-ion battery configuration. This is proven by matching this electrolyte with new high-voltage layered cathode compositions, demonstrating stable electrochemical performance. The present findings of electrochemically stable ionic liquids based on potassium bis(trifluoromethanesulfonyl)amide will bolster further advancement of high-performance cathode materials, whose performance at high-voltage regimes were apparently restricted by the paucity of suitable and compatible electrolytes.
△ Less
Submitted 10 November, 2021; v1 submitted 6 November, 2021;
originally announced November 2021.
-
A Hardware Co-design Workflow for Scientific Instruments at the Edge
Authors:
Kazutomo Yoshii,
Rajesh Sankaran,
Sebastian Strempfer,
Maksim Levental,
Mike Hammer,
Antonino Miceli
Abstract:
As spatial and temporal resolutions of scientific instruments improve, the explosion in the volume of data produced is becoming a key challenge. It can be a critical bottleneck for integration between scientific instruments at the edge and high-performance computers/emerging accelerators. Placing data compression or reduction logic close to the data source is a possible approach to solve the bottl…
▽ More
As spatial and temporal resolutions of scientific instruments improve, the explosion in the volume of data produced is becoming a key challenge. It can be a critical bottleneck for integration between scientific instruments at the edge and high-performance computers/emerging accelerators. Placing data compression or reduction logic close to the data source is a possible approach to solve the bottleneck. However, the realization of such a solution requires the development of custom ASIC designs, which is still challenging in practice and tends to produce one-off implementations unusable beyond the initial intended scope. Therefore, as a feasibility study, we have been investigating a design workflow that allows us to explore algorithmically complex hardware designs and develop reusable hardware libraries for the needs of scientific instruments at the edge. Our vision is to cultivate our hardware development capability for streaming/dataflow hardware components that can be placed close to the data source to enable extreme data-intensive scientific experiments or environmental sensing. Furthermore, reducing data movement is essential to improving computing performance in general. Therefore, our co-design efforts on streaming hardware components can benefit computing applications other than scientific instruments. This vision paper discusses hardware specialization needs in scientific instruments and briefly reviews our progress leveraging the Chisel hardware description language and emerging open-source hardware ecosystems, including a few design examples.
△ Less
Submitted 2 November, 2021;
originally announced November 2021.
-
Designing a Streaming Data Coalescing Architecture for Scientific Detector ASICs with Variable Data Velocity
Authors:
Sebastian Strempfer,
Kazutomo Yoshii,
Mike Hammer,
Dawid Bycul,
Antonino Miceli
Abstract:
Scientific detectors are a key technological enabler for many disciplines. Application-specific integrated circuits (ASICs) are used for many of these scientific detectors. Until recently, pixel detector ASICs have been used mainly for analog signal processing of the charge from the sensor layer and the transmission of raw pixel data off the detector ASIC. However, with the availability of more ad…
▽ More
Scientific detectors are a key technological enabler for many disciplines. Application-specific integrated circuits (ASICs) are used for many of these scientific detectors. Until recently, pixel detector ASICs have been used mainly for analog signal processing of the charge from the sensor layer and the transmission of raw pixel data off the detector ASIC. However, with the availability of more advanced ASIC technology nodes for scientific application, more digital functionality from the computing domains (e.g., compression) can be integrated directly into the detector ASIC to increase data velocity. However, these computing functionalities often have high and variable latency, whereas scientific detectors must operate in real-time (i.e., stall-free) to support continuous streaming of sampled data. This paper presents an example from the domain of pixel detectors with on-chip data compression for X-ray science applications. To address the challenges of variable-sized data from a parallel stream of compressors, we present an ASIC design architecture to coalesce variable-length data for transmission over a fixed bit-width network interface.
△ Less
Submitted 14 October, 2021;
originally announced October 2021.
-
Strategies for on-chip digital data compression for X-ray pixel detectors
Authors:
Mike Hammer,
Kazutomo Yoshii,
Antonino Miceli
Abstract:
The continued desire for X-ray pixel detectors with higher frame rates will stress the ability of application-specific integrated circuit (ASIC) designers to provide sufficient off-chip bandwidth to reach continuous frame rates in the 1 MHz regime. To move from the current 10 kHz to the 1 MHz frame rate regime, ASIC designers will continue to pack as many power-hungry high-speed transceivers at th…
▽ More
The continued desire for X-ray pixel detectors with higher frame rates will stress the ability of application-specific integrated circuit (ASIC) designers to provide sufficient off-chip bandwidth to reach continuous frame rates in the 1 MHz regime. To move from the current 10 kHz to the 1 MHz frame rate regime, ASIC designers will continue to pack as many power-hungry high-speed transceivers at the periphery of the ASIC as possible. In this paper, however, we present new strategies to make the most efficient use of the off-chip bandwidth by utilizing data compression schemes for X-ray photon-counting and charge-integrating pixel detectors. In particular, we describe a novel in-pixel compression scheme that converts from analog to digital converter units to encoded photon counts near the photon Poisson noise level and achieves a compression ratio of $>\!1.5\times$ independent of the dataset. In addition, we describe a simple yet efficient zero-suppression compression scheme called ``zeromask'' (ZM) located at the ASIC's edge before streaming data off the ASIC chip. ZM achieves average compression ratios of $>\!4\times$, $>\!7\times$, and $>\!8\times$ for high-energy X-ray diffraction, ptychography, and X-ray photon correlation spectroscopy datasets, respectively. We present the conceptual designs, register-transfer level block diagrams, and the physical ASIC implementation of these compression schemes in 65-nm CMOS. When combined, these two digital compression schemes could increase the effective off-chip bandwidth by a factor of 6-12$\times$.
△ Less
Submitted 1 August, 2020; v1 submitted 4 June, 2020;
originally announced June 2020.
-
Aversion of face-to-face situation of pedestrians eases crowding condition
Authors:
Sho Yajima,
Kiwamu Yoshii,
Yutaka Sumino
Abstract:
We conducted numerical simulation for a crowd of pedestrians. Each pedestrian, modeled with three circles, has a shape whose long axis is perpendicular to the anteroposterior axis, and is designed to move fixed destination. The pedestrians have friction at the surface and soft repulsion. In this study, we newly introduced an active rotation which captures psychological effect to evade face-to-face…
▽ More
We conducted numerical simulation for a crowd of pedestrians. Each pedestrian, modeled with three circles, has a shape whose long axis is perpendicular to the anteroposterior axis, and is designed to move fixed destination. The pedestrians have friction at the surface and soft repulsion. In this study, we newly introduced an active rotation which captures psychological effect to evade face-to-face situation. The numerical simulation revealed that active rotation induces fluidization of system leading to higher flux of pedestrian. We further confirmed that this fluidization is due to fragmentation of force chain induced by the active rotation.
△ Less
Submitted 1 April, 2020; v1 submitted 31 March, 2020;
originally announced March 2020.
-
A compact frequency-stabilized pump laser for wavelength conversion in long-distance quantum communication
Authors:
Kohei Ikeda,
Yusuke Hisai,
Kazumichi Yoshii,
Hideo Kosaka,
Feng-Lei Hong,
Tomoyuki Horikiri
Abstract:
We demonstrate a compact frequency-stabilized laser at 1064 nm using Doppler-free saturation absorption spectroscopy of molecular iodine. The achieved laser frequency stability and linewidth are 5.7 10-12 (corresponding to an uncertainty of the laser frequency of 1.6 kHz) and 400 kHz, respectively. The developed frequency-stabilized laser can be used as a pump laser for wavelength conversion from…
▽ More
We demonstrate a compact frequency-stabilized laser at 1064 nm using Doppler-free saturation absorption spectroscopy of molecular iodine. The achieved laser frequency stability and linewidth are 5.7 10-12 (corresponding to an uncertainty of the laser frequency of 1.6 kHz) and 400 kHz, respectively. The developed frequency-stabilized laser can be used as a pump laser for wavelength conversion from visible to telecom (or vice versa) to connect quantum memories utilizing nitrogen-vacancy centers in diamond at remote nodes in fiber-based quantum communication.
△ Less
Submitted 10 July, 2018;
originally announced July 2018.
-
Dual-frequency injection-locked continuous-wave near-infrared laser
Authors:
Trivikramarao Gavara,
Takeru Ohashi,
Yusuke Sasaki,
Takuya Kawashima,
Hiroaki Hamano,
Ryo Yoshizaki,
Yuki Fujimura,
Kazumichi Yoshii,
Chiaki Ohae,
Masayuki Katsuragawa
Abstract:
We report a dual-frequency injection-locked continuous-wave near-infrared laser. The entire system consists of a Ti:sapphire ring laser as a power oscillator, two independent diode-lasers employed as seed lasers, and a master cavity providing a frequency reference. Stable dual-frequency injection-locked oscillation is achieved with a maximum output power of 2.8 W. As fundamental performance featur…
▽ More
We report a dual-frequency injection-locked continuous-wave near-infrared laser. The entire system consists of a Ti:sapphire ring laser as a power oscillator, two independent diode-lasers employed as seed lasers, and a master cavity providing a frequency reference. Stable dual-frequency injection-locked oscillation is achieved with a maximum output power of 2.8 W. As fundamental performance features of this laser system, we show its single longitudinal/transverse mode characteristics and practical power stability. Furthermore, as advanced features, we demonstrate arbitrary selectivity of the two frequencies and flexible control of their relative powers by simply manipulating the seed lasers.
△ Less
Submitted 7 April, 2016;
originally announced April 2016.
-
The simplest rout to generating a train of attosecond pulses
Authors:
Kazumichi Yoshii,
John Kiran Anthony,
Masayuki Katsuragawa
Abstract:
We report on new routes to generating a train of attosecond pulses. The methods are extremely simple and robust; we need to place only a few thin dispersive materials in the optical path. We numerically demonstrate the generation of a train of attosecond pulses with a transform-limited pulse duration of 728 as and a repetition period of 8.03 fs in gaseous parahydrogen.
We report on new routes to generating a train of attosecond pulses. The methods are extremely simple and robust; we need to place only a few thin dispersive materials in the optical path. We numerically demonstrate the generation of a train of attosecond pulses with a transform-limited pulse duration of 728 as and a repetition period of 8.03 fs in gaseous parahydrogen.
△ Less
Submitted 29 July, 2012;
originally announced July 2012.