-
Data quality control system and long-term performance monitor of the LHAASO-KM2A
Authors:
Zhen Cao,
F. Aharonian,
Axikegu,
Y. X. Bai,
Y. W. Bao,
D. Bastieri,
X. J. Bi,
Y. J. Bi,
W. Bian,
A. V. Bukevich,
Q. Cao,
W. Y. Cao,
Zhe Cao,
J. Chang,
J. F. Chang,
A. M. Chen,
E. S. Chen,
H. X. Chen,
Liang Chen,
Lin Chen,
Long Chen,
M. J. Chen,
M. L. Chen,
Q. H. Chen,
S. Chen
, et al. (263 additional authors not shown)
Abstract:
The KM2A is the largest sub-array of the Large High Altitude Air Shower Observatory (LHAASO). It consists of 5216 electromagnetic particle detectors (EDs) and 1188 muon detectors (MDs). The data recorded by the EDs and MDs are used to reconstruct primary information of cosmic ray and gamma-ray showers. This information is used for physical analysis in gamma-ray astronomy and cosmic ray physics. To…
▽ More
The KM2A is the largest sub-array of the Large High Altitude Air Shower Observatory (LHAASO). It consists of 5216 electromagnetic particle detectors (EDs) and 1188 muon detectors (MDs). The data recorded by the EDs and MDs are used to reconstruct primary information of cosmic ray and gamma-ray showers. This information is used for physical analysis in gamma-ray astronomy and cosmic ray physics. To ensure the reliability of the LHAASO-KM2A data, a three-level quality control system has been established. It is used to monitor the status of detector units, stability of reconstructed parameters and the performance of the array based on observations of the Crab Nebula and Moon shadow. This paper will introduce the control system and its application on the LHAASO-KM2A data collected from August 2021 to July 2023. During this period, the pointing and angular resolution of the array were stable. From the observations of the Moon shadow and Crab Nebula, the results achieved using the two methods are consistent with each other. According to the observation of the Crab Nebula at energies from 25 TeV to 100 TeV, the time averaged pointing errors are estimated to be $-0.003^{\circ} \pm 0.005^{\circ}$ and $0.001^{\circ} \pm 0.006^{\circ}$ in the R.A. and Dec directions, respectively.
△ Less
Submitted 13 June, 2024; v1 submitted 20 May, 2024;
originally announced May 2024.
-
Dimensional Analysis Theory and Molecular Dynamics Simulation of Polypropylene Melt Flow during Injection Molding Process
Authors:
**rong Zhang,
Dadong Yan,
Li Peng,
Xianbo Huang
Abstract:
Flow marks are common surface defects that occur in injection-molded products. Their formation may be related to the flow process of the melt in the mold. Through dimensional analysis, we have discovered that the geometric shape of the flow field is controlled by specific dimensionless quantities. These quantities can be summarized as follows: geometric dimensionless quantities related to the shap…
▽ More
Flow marks are common surface defects that occur in injection-molded products. Their formation may be related to the flow process of the melt in the mold. Through dimensional analysis, we have discovered that the geometric shape of the flow field is controlled by specific dimensionless quantities. These quantities can be summarized as follows: geometric dimensionless quantities related to the shape of the mold, material dimensionless quantities related to the melt and mold materials, and physical dimensionless quantities related to the flow. When the geometric shape of the mold changes proportionally, with the melt and mold material fixed, and the initial temperature of the melt and mold fixed, the geometric shape of the flow field will be solely controlled by the Weissenberg number Wi. If Wi is kept constant, changing the injection speed, changing the relaxation time of the polypropylene melt, or scaling the mold will result in similar geometric shapes of the flow field. If the size of the mold is not changed, the geometric shape of the flow field will be the same. Since the dimensionless equation represents a similar system of all sizes, we verified the above conclusion through molecular dynamics simulations at a smaller scale. After further improvement of the micro simulation system, there is a possibility of visualizing the formation process of flow marks. This would greatly aid in the advancement of theory and the elimination of flow marks in production and experiments. This work also illustrates that the methodology of dimensional analysis plus molecular dynamics simulation may be applied to a wider range of other systems, scaling down large systems and thus significantly reducing their computational effort.
△ Less
Submitted 31 January, 2024;
originally announced January 2024.
-
A Configurable Ultra-Low Noise Current Source for Transition-Edge Sensor Characterization
Authors:
N. Li,
G. Liao,
D. Yan,
Y. Xu,
Y. Zhang,
Z. Liu,
S. Yuan,
Y. Zhang,
H. Gao,
Y. Li,
Y. Gu,
C. Liu,
H. Li,
Z. Li,
X. Ren
Abstract:
Transition-edge sensors (TESs) are sensitive devices for detecting photons from millimeter radiation to gamma rays. Their photon counting efficiency and collecting area benefit from large-array multiplexing scheme, and therefore the development of multiplexing readout system has been an important topic in this field. Among the many multiplex techniques, time-division multiplexing (TDM) superconduc…
▽ More
Transition-edge sensors (TESs) are sensitive devices for detecting photons from millimeter radiation to gamma rays. Their photon counting efficiency and collecting area benefit from large-array multiplexing scheme, and therefore the development of multiplexing readout system has been an important topic in this field. Among the many multiplex techniques, time-division multiplexing (TDM) superconducting quantum interference device (SQUID) has been used most widely for TES readout. In this work, we design a Configurable Ultra-Low Noise Current Source (CLCS) for TES characterization and as a part of a whole TDM-TES bias control system. The CLCS is based on the feedback structure of ultra-low noise instrumentation amplifiers and low-noise, high-resolution (20 bits) digital-to-analog converter (DAC). CLCS has an ultra-high resolution of 10 nA in the 0 to 5 mA current output range, and can perform current-voltage (IV) sweep and bias-step tests to measure key TES parameters on board. The feedback structure of the CLCS also avoids the issue of impedance mismatch.
△ Less
Submitted 2 April, 2024; v1 submitted 20 December, 2023;
originally announced December 2023.
-
Extrinsic nonlinear Kerr rotation in topological materials under a magnetic field
Authors:
Shuang Wu,
Zaiyao Fei,
Zeyuan Sun,
Yangfan Yi,
Wei Xia,
Dayu Yan,
Yanfeng Guo,
Youguo Shi,
Jiaqiang Yan,
David H. Cobden,
Wei-Tao Liu,
Xiaodong Xu,
Shiwei Wu
Abstract:
Topological properties in quantum materials are often governed by symmetry and tuned by crystal structure and external fields, and hence symmetry-sensitive nonlinear optical measurements in a magnetic field are a valuable probe. Here we report nonlinear magneto-optical second harmonic generation (SHG) studies of non-magnetic topological materials including bilayer WTe2, monolayer WSe2 and bulk TaA…
▽ More
Topological properties in quantum materials are often governed by symmetry and tuned by crystal structure and external fields, and hence symmetry-sensitive nonlinear optical measurements in a magnetic field are a valuable probe. Here we report nonlinear magneto-optical second harmonic generation (SHG) studies of non-magnetic topological materials including bilayer WTe2, monolayer WSe2 and bulk TaAs. The polarization-resolved patterns of optical SHG under magnetic field show nonlinear Kerr rotation in these time-reversal symmetric materials. For materials with three-fold rotational symmetric lattice structure, the SHG polarization pattern rotates just slightly in a magnetic field, whereas in those with mirror or two-fold rotational symmetry the SHG polarization pattern rotates greatly and distorts. These different magneto-SHG characters can be understood by considering the superposition of the magnetic field-induced time-noninvariant nonlinear optical tensor and the crystal-structure-based time-invariant counterpart. The situation is further clarified by scrutinizing the Faraday rotation, whose subtle interplay with crystal symmetry accounts for the diverse behavior of the extrinsic nonlinear Kerr rotation in different materials. Our work illustrates the application of magneto-SHG techniques to directly probe nontrivial topological properties, and underlines the importance of minimizing extrinsic nonlinear Kerr rotation in polarization-resolved magneto-optical studies.
△ Less
Submitted 18 September, 2023;
originally announced September 2023.
-
Absolute Energy Measurements with Superconducting Transition-Edge Sensors for Muonic X-ray Spectroscopy at 44 keV
Authors:
Daikang Yan,
Joel C. Weber,
Tejas Guruswamy,
Kelsey M. Morgan,
Galen C. O'Neil,
Abigail L. Wessels,
Douglas A. Bennett,
Christine G. Pappas,
John A. Mates,
Johnathon D. Gard,
Daniel T. Becker,
Joseph W. Fowler,
Daniel S. Swetz,
Daniel R. Schmidt,
Joel N. Ullom,
Takuma Okumura,
Tadaaki Isobe,
Toshiyuki Azuma,
Shinji Okada,
Shinya Yamada,
Tadashi Hashimoto,
Orlando Quaranta,
Antonino Miceli,
Lisa M. Gades,
Umeshkumar M. Patel
, et al. (3 additional authors not shown)
Abstract:
Superconducting transition-edge sensor (TES) microcalorimeters have great utility in x-ray applications owing to their high energy resolution, good collecting efficiency and the feasibility of being multiplexed into large arrays. In this work, we develop hard x-ray TESs to measure the absolute energies of muonic-argon ($μ$-Ar) transition lines around 44 keV and 20 keV. TESs with sidecar absorbers…
▽ More
Superconducting transition-edge sensor (TES) microcalorimeters have great utility in x-ray applications owing to their high energy resolution, good collecting efficiency and the feasibility of being multiplexed into large arrays. In this work, we develop hard x-ray TESs to measure the absolute energies of muonic-argon ($μ$-Ar) transition lines around 44 keV and 20 keV. TESs with sidecar absorbers of different heat capacities were fabricated and characterized for their energy resolution and calibration uncertainty. We achieved ~ 1 eV absolute energy measurement accuracy at 44 keV, and < 12 eV energy resolution at 17.5 keV.
△ Less
Submitted 21 July, 2022;
originally announced July 2022.
-
Enhancing Innate and Adaptive Immune Systems by Cold Atmospheric Plasma (CAP) and Its Antitumor Immunity
Authors:
Fengdong Cheng,
Dayun Yan,
Jie Chen,
Zi Wang,
Alex Horkowitz,
Michael Keidar,
Eduardo M. Sotomayor
Abstract:
Cold atmospheric plasma (CAP) is a near room temperature ionized gas, generated under non-equilibrium discharge conditions. Here we show that a short exposure of rat peritoneal exudate macrophages and T-cells to CAP in vitro, triggered an inflammatory phenotype leading to better antigen-presenting and effector cell function respectively. Different from previous studies mainly using immortalized ce…
▽ More
Cold atmospheric plasma (CAP) is a near room temperature ionized gas, generated under non-equilibrium discharge conditions. Here we show that a short exposure of rat peritoneal exudate macrophages and T-cells to CAP in vitro, triggered an inflammatory phenotype leading to better antigen-presenting and effector cell function respectively. Different from previous studies mainly using immortalized cell lines, both macrophage and T-cells in this study were primary cells isolated from mice. Furthermore, ex-vivo exposure of T-cells to CAP, followed by their adoptive transfer into tumor-bearing mice resulted in a strong antitumor effect in vivo. Mechanistically, CAP seems to disrupt tolerogenic pathways leading to enhanced production of pro-inflammatory cytokines while limiting the production of anti-inflammatory cytokines and the expression of inhibitory molecules such as programmed death-ligand 1 (PD-L1). CAP represents therefore a novel, non-toxic and easy to deliver technology to augment the function of immune cells and enhance antitumor responses when used as a component of T-cell adoptive immunotherapies strategies or, potentially in combination with other cancer immunotherapeutic approaches.
△ Less
Submitted 30 January, 2022;
originally announced January 2022.
-
Diffractive lensless imaging with optimized Voronoi-Fresnel phase
Authors:
Qiang Fu,
Dong-Ming Yan,
Wolfgang Heidrich
Abstract:
Lensless cameras are a class of imaging devices that shrink the physical dimensions to the very close vicinity of the image sensor by replacing conventional compound lenses with integrated flat optics and computational algorithms. Here we report a diffractive lensless camera with spatially-coded Voronoi-Fresnel phase to achieve superior image quality. We propose a design principle of maximizing th…
▽ More
Lensless cameras are a class of imaging devices that shrink the physical dimensions to the very close vicinity of the image sensor by replacing conventional compound lenses with integrated flat optics and computational algorithms. Here we report a diffractive lensless camera with spatially-coded Voronoi-Fresnel phase to achieve superior image quality. We propose a design principle of maximizing the acquired information in optics to facilitate the computational reconstruction. By introducing an easy-to-optimize Fourier domain metric, Modulation Transfer Function volume (MTFv), which is related to the Strehl ratio, we devise an optimization framework to guide the optimization of the diffractive optical element. The resulting Voronoi-Fresnel phase features an irregular array of quasi-Centroidal Voronoi cells containing a base first-order Fresnel phase function. We demonstrate and verify the imaging performance for photography applications with a prototype Voronoi-Fresnel lensless camera on a 1.6-megapixel image sensor in various illumination conditions. Results show that the proposed design outperforms existing lensless cameras, and could benefit the development of compact imaging systems that work in extreme physical conditions.
△ Less
Submitted 7 December, 2022; v1 submitted 28 September, 2021;
originally announced September 2021.
-
Low Temperature Plasma for Biology, Hygiene, and Medicine: Perspective and Roadmap
Authors:
Mounir Laroussi,
Sander Bekeschus,
Michael Keidar,
Annemie Bogaerts,
Alexander Fridman,
XinPei Lu,
Kostya,
Ostrikov,
Masaru Hori,
Katharina Stapelmann,
Vandana Miller,
Stephan Reuter,
Christophe Laux,
Ali Mesbah,
James Walsh,
Chunqi Jiang,
Selma Mededovic Thagard,
Hiromasa Tanaka,
DaWei Liu,
Dayun Yan,
Maksudbek Yusupov
Abstract:
Plasma, the fourth and most pervasive state of matter in the visible universe, is a fascinating medium that is connected to the beginning of our universe itself. Man-made plasmas are at the core of many technological advances that include the fabrication of semiconductor devices, which enabled the modern computer and communication revolutions. The introduction of low temperature, atmospheric press…
▽ More
Plasma, the fourth and most pervasive state of matter in the visible universe, is a fascinating medium that is connected to the beginning of our universe itself. Man-made plasmas are at the core of many technological advances that include the fabrication of semiconductor devices, which enabled the modern computer and communication revolutions. The introduction of low temperature, atmospheric pressure plasmas to the biomedical field has ushered a new revolution in the healthcare arena that promises to introduce plasma-based therapies to combat some thorny and long-standing medical challenges. This paper presents an overview of where research is at today and discusses innovative concepts and approaches to overcome present challenges and take the field to the next level. It is written by a team of experts who took an in-depth look at the various biomedical applications, made critical analysis, and proposed ideas and concepts that should help the research community focus their efforts on clear and practical steps necessary to keep the field advancing for decades to come.
△ Less
Submitted 6 August, 2021;
originally announced August 2021.
-
Improving the particle identification of radioactive isotope beams at the RIBLL2 separator
Authors:
Fang Fang,
Shuwen Tang,
Shitao Wang,
Xueheng Zhang,
Zhiyu Sun,
Yuhong Yu,
Duo Yan,
Shuya **,
Yixuan Zhao,
Shaobo Ma,
Yongjie Zhang
Abstract:
To improve the ability of particle identification of the RIBLL2 separator at the HIRFL-CSR complex, a new high-performance detector for measuring fragment starting time and position at the F1 dispersive plane has been constructed and installed, and a method for achieving precise B\r{ho} determination has been developed using the experimentally derived ion-optical transfer matrix elements from the…
▽ More
To improve the ability of particle identification of the RIBLL2 separator at the HIRFL-CSR complex, a new high-performance detector for measuring fragment starting time and position at the F1 dispersive plane has been constructed and installed, and a method for achieving precise B\r{ho} determination has been developed using the experimentally derived ion-optical transfer matrix elements from the measured position and ToF information. Using the high-performance detectors and the precise B\r{ho} determination method, the fragments produced by the fragmentation of 78Kr at 300 MeV/nucleon were identified clearly at the RIBLL2-ETF under full momentum acceptance. The atomic number Z resolution of σZ~0.19 and the mass-to-charge ratio A/Q resolution of σA/Q~5.8e-3 were obtained for the 75As33+ fragment. This great improvement will increase the collection efficiency of exotic nuclei, extend the range of nuclei of interest from the A<40 mass region up to the A~80 mass region, and promote the development of radioactive nuclear beam experiments at the RIBLL2 separator.
△ Less
Submitted 8 June, 2021;
originally announced June 2021.
-
HyperCI: A Higher Order Collective Influence Measure for Hypernetwork Dismantling
Authors:
Dengcheng Yan,
Zijian Wu,
Yi Zhang,
Shiqin Qu,
Yiwen Zhang,
Hong Zhong
Abstract:
The connectivity of networked systems is often dependent on a small portion of critical nodes. Network dismantling studies the strategy to identify a subset of nodes the removal of which will maximally destroy the connectivity of a network and fragment it into disconnected components. However, conventional network dismantling approaches focus on simple network which models only pairwise interactio…
▽ More
The connectivity of networked systems is often dependent on a small portion of critical nodes. Network dismantling studies the strategy to identify a subset of nodes the removal of which will maximally destroy the connectivity of a network and fragment it into disconnected components. However, conventional network dismantling approaches focus on simple network which models only pairwise interaction between nodes while groupwise interactions among arbitrary number of nodes are ubiquitous in networked systems like integrated circuits. Groupwise interactions modeled by hypernetwork introduce higher order connectivity patterns, which limits the application of conventional network dismantling methods on hypernetwork. In this brief, we propose HyperCI, a higher order collective influence measure for hypernetwork dismantling. It considers the node co-occurrence characteristics and higher order influence ability both introduced by hyperedges in hypernetwork. We evaluate the effectiveness of our proposed HyperCI on six real world hypernetworks including integrated circuits and citation networks and the results indicate our proposed HyperCI outperforms baseline network dismantling methods for both simple network and hypernetwork.
△ Less
Submitted 13 May, 2022; v1 submitted 10 March, 2021;
originally announced March 2021.
-
Construction and On-site Performance of the LHAASO WFCTA Camera
Authors:
F. Aharonian,
Q. An,
Axikegu,
L. X. Bai,
Y. X. Bai,
Y. W. Bao,
D. Bastieri,
X. J. Bi,
Y. J. Bi,
H. Cai,
J. T. Cai,
Z. Cao,
Z. Cao,
J. Chang,
J. F. Chang,
X. C. Chang,
B. M. Chen,
J. Chen,
L. Chen,
L. Chen,
L. Chen,
M. J. Chen,
M. L. Chen,
Q. H. Chen,
S. H. Chen
, et al. (234 additional authors not shown)
Abstract:
The focal plane camera is the core component of the Wide Field-of-view Cherenkov/fluorescence Telescope Array (WFCTA) of the Large High-Altitude Air Shower Observatory (LHAASO). Because of the capability of working under moonlight without aging, silicon photomultipliers (SiPM) have been proven to be not only an alternative but also an improvement to conventional photomultiplier tubes (PMT) in this…
▽ More
The focal plane camera is the core component of the Wide Field-of-view Cherenkov/fluorescence Telescope Array (WFCTA) of the Large High-Altitude Air Shower Observatory (LHAASO). Because of the capability of working under moonlight without aging, silicon photomultipliers (SiPM) have been proven to be not only an alternative but also an improvement to conventional photomultiplier tubes (PMT) in this application. Eighteen SiPM-based cameras with square light funnels have been built for WFCTA. The telescopes have collected more than 100 million cosmic ray events and preliminary results indicate that these cameras are capable of working under moonlight. The characteristics of the light funnels and SiPMs pose challenges (e.g. dynamic range, dark count rate, assembly techniques). In this paper, we present the design features, manufacturing techniques and performances of these cameras. Finally, the test facilities, the test methods and results of SiPMs in the cameras are reported here.
△ Less
Submitted 4 July, 2021; v1 submitted 29 December, 2020;
originally announced December 2020.
-
Ultrahigh flexoelectric effect of 3D interconnected porous polymers: modelling and verification
Authors:
Mingyuan Zhang,
Dongze Yan,
Jianxiang Wang,
Li-Hua Shao
Abstract:
Non-conductive materials like rubbers, plastics, ceramics, and even semiconductors have the property of flexoelectricity, which means that they can generate electricity when bent and twisted. However, an irregular shape or a peculiar load has been the necessary condition to realize flexoelectricity, and the weight and deformability specific ratios of flexoelectricity of solids are limited. In this…
▽ More
Non-conductive materials like rubbers, plastics, ceramics, and even semiconductors have the property of flexoelectricity, which means that they can generate electricity when bent and twisted. However, an irregular shape or a peculiar load has been the necessary condition to realize flexoelectricity, and the weight and deformability specific ratios of flexoelectricity of solids are limited. In this work, we develop a theoretical model of flexoelectricity of three-dimensional interconnected porous materials. Compared to the solid materials, porous materials can exhibit flexoelectricity under arbitrary loading forms due to their complex microstructures, and the weight and deformability specific flexoelectric output is much higher than that of the solids. Then, we verify the model by measuring the flexoelectric response of polydimethylsiloxane (PDMS) and porous polyvinylidene fluoride (PVDF). The porous PDMS with 3D micron-scale interconnected structures exhibits two orders of magnitude higher weight and deformability specific flexoelectric output than that of the solid truncated pyramid PDMS. The flexoelectric signal is found to be linearly proportional to the applied strain, the microstructural size and the frequency. Finally, we apply the theory to a more practical bending sensor, and demonstrate its stable functioning and accurate response. Our model can be applied to other porous materials, and the results highlight the new potential of porous micro-structured materials with a significant flexoelectric effect in the fields of mechanical sensing, actuating, energy harvesting, and biomimetics as light-weight materials.
△ Less
Submitted 6 March, 2021; v1 submitted 8 September, 2020;
originally announced September 2020.
-
Measurement of real contact area for rough metal surfaces and the distinction of contribution from elasticity and plasticity
Authors:
Lei-Tao Li,
Xuan-Ming Liang,
Yu-Zhe Xing,
Duo Yan,
Gang-Feng Wang
Abstract:
The measurement of real contact area between rough surfaces is one of most challenge problems in contact mechanics and is of importance to understand some physical mechanisms in tribology. Based on the frustrated total internal reflection, a new apparatus is designed to measure the real contact area. For brass samples with various surface topographies, the relation between normal load and real con…
▽ More
The measurement of real contact area between rough surfaces is one of most challenge problems in contact mechanics and is of importance to understand some physical mechanisms in tribology. Based on the frustrated total internal reflection, a new apparatus is designed to measure the real contact area. For brass samples with various surface topographies, the relation between normal load and real contact area is measured. Our experiments verify the linear relationship between load and real contact area during loading process. More importantly, the unloading process is firstly considered to distinguish the contribution of elasticity and plasticity in contact of rough surfaces. It is found that both elasticity and plasticity are involved throughout the continuous loading process, different from some present understanding and assumptions that they play at different loading stages. A quantitative parameter is proposed to indicate the contribution of plasticity. The present work not only provides an experimental method to measure real contact area but figure out how elastic and plastic deformation works in contact of rough surfaces.
△ Less
Submitted 15 July, 2020;
originally announced August 2020.
-
Estimating the Number of Infected Cases in COVID-19 Pandemic
Authors:
Donghui Yan,
Ying Xu,
Pei Wang
Abstract:
The COVID-19 pandemic has caused major disturbance to human life. An important reason behind the widespread social anxiety is the huge uncertainty about the pandemic. A fundamental uncertainty is how many or what percentage of people have been infected. There are published and frequently updated data on various statistics of the pandemic, at local, country or global level. However, due to various…
▽ More
The COVID-19 pandemic has caused major disturbance to human life. An important reason behind the widespread social anxiety is the huge uncertainty about the pandemic. A fundamental uncertainty is how many or what percentage of people have been infected. There are published and frequently updated data on various statistics of the pandemic, at local, country or global level. However, due to various reasons, many cases were not included in those reported numbers. We propose a structured approach for the estimation of the number of unreported cases, where we distinguish cases that arrive late in the reported numbers and those who had mild or no symptoms and thus were not captured by any medical system at all. We use post-report data for the estimation of the former and population matching to the latter. We estimate that the reported number of infected cases in the US should be corrected by multiplying a factor of 220.54% as of Apr 20, 2020, while the infection ratio out of the US population is estimated to be 0.53%, implying a case mortality rate at 2.85% which is close to the 3.4% suggested by the WHO in Mar 2020. Towards the end of the summer of 2020, the overall infection ratio of the US rises to 2.49% while the case mortality decreases to 2.09%, and the ratio of asymptomatic cases out of all infected cases reduces from the pre-summer 35-40% to around 20-25%.
△ Less
Submitted 3 March, 2021; v1 submitted 24 May, 2020;
originally announced May 2020.
-
Development of Transition-Edge Sensor X-ray Microcalorimeter Linear Array for Compton Scattering and Energy Dispersive Diffraction Imaging
Authors:
U. Patel,
R. Divan,
L. Gades,
T. Guruswamy,
D. Yan,
O. Quaranta,
A. Miceli
Abstract:
We present a strip transition-edge sensor microcalorimeter linear array detector developed for energy dispersive X-ray diffraction imaging and Compton scattering applications. The prototype detector is an array of 20 transition-edge-sensors with absorbers in strip geometry arranged in a linear array. We discuss the fabrication steps needed to develop this array including Mo/Cu bilayer, Au electrop…
▽ More
We present a strip transition-edge sensor microcalorimeter linear array detector developed for energy dispersive X-ray diffraction imaging and Compton scattering applications. The prototype detector is an array of 20 transition-edge-sensors with absorbers in strip geometry arranged in a linear array. We discuss the fabrication steps needed to develop this array including Mo/Cu bilayer, Au electroplating, and proof-of-principle fabrication of long strips of SiNx membranes. We demonstrate minimal unwanted effect of strip geometry on X-ray pulse response, and show linear relationship of 1/pulse height and pulse decay times with absorber length. For the absorber lengths studied, preliminary measurements show energy resolutions of 40 eV to 180 eV near 17 keV. Furthermore, we show that the heat flow to the cold bath is nearly independent of the absorber area and depends on the SiNx membrane geometry.
△ Less
Submitted 28 November, 2019; v1 submitted 27 August, 2019;
originally announced August 2019.
-
High CO2-tolerance oxygen permeation dual-phase membranes Ce0.9Pr0.1O2-δ-Pr0.6Sr0.4Fe0.8Al0.2O3-δ
Authors:
Lei Shi,
Shu Wang,
Tianni Lu,
Yuan He,
Dong Yan,
Qi Lan,
Zhiang Xie,
Haoqi Wang,
Man-Rong Li,
Juergen Caro,
Huixia Luo
Abstract:
High stability and oxygen permeability are two prominent requirements for the oxygen transport membrane candidates used as industrialization. Herein, we report several composite membranes based on xwt.%Ce0.9Pr0.1O2(CPO)-(100-x)wt.%Pr0.6Sr0.4Fe0.8Al0.2O3(PSFAO) (x = 50, 60 and 75) prepared via a modified Pechini method. Oxygen permeability test reveals that the 60CPO-40PSFAO composition exhibits th…
▽ More
High stability and oxygen permeability are two prominent requirements for the oxygen transport membrane candidates used as industrialization. Herein, we report several composite membranes based on xwt.%Ce0.9Pr0.1O2(CPO)-(100-x)wt.%Pr0.6Sr0.4Fe0.8Al0.2O3(PSFAO) (x = 50, 60 and 75) prepared via a modified Pechini method. Oxygen permeability test reveals that the 60CPO-40PSFAO composition exhibits the highest oxygen permeability. The oxygen permeation flux through the optimal uncoated 0.33 mm-thickness 60CPO-40PSFAO composite can reach 1.03 mL cm-2 min-1 (over the general requirement value of 1 mL cm-2 min-1) in air/He atmosphere at 1000 °C. In situ XRD performance confirms the optimal 60CPO-40PSFAO sample shows excellent stability in CO2-containing atmospheres. The 60CPO-40PSFAO membrane still exhibits simultaneously excellent oxygen permeability and phase stability after operating for over 100 h at air/CO2 condition at 1000 °C, which further indicates that the 60CPO-40PSFAO composite is likely to be used for oxygen supply in CO2 capture
△ Less
Submitted 27 July, 2019;
originally announced July 2019.
-
Effects of Al content on the oxygen permeability through dual-phase membrane 60Ce$_{0.9}$Pr$_{0.1}$O$_{2-δ}$-40Pr$_{0.6}$Sr$_{0.4}$Fe$_{1-x}$Al$_x$O$_{3-δ}$
Authors:
Lei Shi,
Shu Wang,
Tianni Lu,
Yuan He,
Dong Yan,
Qi Lan,
Zhiang Xie,
Haoqi Wang,
Mebrouka Boubeche,
Huixia Luo
Abstract:
Ceramic dual-phase oxygen transport membranes with the composition of 60wt.% Ce0.9Pr0.1O2-δ-40wt.%Pr0.6Sr0.4Fe1-xAlxO3-δ (x = 0.05, 0.1, 0.2, 0.3, 0.4, 0.6, 0.8, 1.0) (60CPO-40PSF1-xAxO) based on 60Ce0.9Pr0.1O2-δ-40Pr0.6Sr0.4FeO3-δ doped Al was successfully synthesized through a modified Pechini method. Crystal structure, surface microtopography and oxygen permeability are investigated systematica…
▽ More
Ceramic dual-phase oxygen transport membranes with the composition of 60wt.% Ce0.9Pr0.1O2-δ-40wt.%Pr0.6Sr0.4Fe1-xAlxO3-δ (x = 0.05, 0.1, 0.2, 0.3, 0.4, 0.6, 0.8, 1.0) (60CPO-40PSF1-xAxO) based on 60Ce0.9Pr0.1O2-δ-40Pr0.6Sr0.4FeO3-δ doped Al was successfully synthesized through a modified Pechini method. Crystal structure, surface microtopography and oxygen permeability are investigated systematically. The cell parameters of perovskite phase first increased and then decreased with the increase of Al content, which is related to the radius of the Al3+ and the formation of impurity phase. As x ranges from 0.1 to 0.8, the oxygen permeability of the materials first increases and then decreases, and the maximum value of oxygen permeation rate for 60CPO-40PSF1-xAxO membranes with 0.4mm thickness at 1000 °C is 1.12 mL min-1 cm-2 when x = 0.4. XRD measurements revealed high temperature stability and CO2-tolerant property of the dual-phase composites. The partial replacement of Fe$^{3+}$/Fe$^{4+}$ by Al$^{3+}$ causes the material not only to exhibit good stability, but also to increase the oxygen permeability of the membranes.
△ Less
Submitted 3 July, 2019;
originally announced July 2019.
-
High-flux dual-phase percolation membrane for oxygen separation
Authors:
Shu Wang,
Lei Shi,
Zhiang Xie,
Yuan He,
Dong Yan,
Man-Rong Li,
Juergen Caro,
Huixia Luo
Abstract:
A series of composites based on (100-x)wt.%Ce0.9Pr0.1O2-δ-xwt.%Pr0.6Ca0.4FeO3-δ (x = 25, 40 and 50) doped with the cheap and abundant alkaline earth metal Ca2+ at the A-site has been successfully designed and fabricated. The crystal structure, oxygen permeability, phase and CO2 stability were evaluated. The composition of 60wt.%Ce0.9Pr0.1O2-δ-40wt.%Pr0.6Ca0.4FeO3-δ(60CPO-40PCFO) possesses the high…
▽ More
A series of composites based on (100-x)wt.%Ce0.9Pr0.1O2-δ-xwt.%Pr0.6Ca0.4FeO3-δ (x = 25, 40 and 50) doped with the cheap and abundant alkaline earth metal Ca2+ at the A-site has been successfully designed and fabricated. The crystal structure, oxygen permeability, phase and CO2 stability were evaluated. The composition of 60wt.%Ce0.9Pr0.1O2-δ-40wt.%Pr0.6Ca0.4FeO3-δ(60CPO-40PCFO) possesses the highest oxygen permeability among three studied composites. At 1000 oC, the oxygen permeation fluxes through the 0.3 mm-thickness 60CPO-40PCFO membranes after porous La0.6Sr0.4CoO3-δ each to 1.00 mL cm-2 min-1 and 0.62 mL cm-2 min-1 under air/He and air/CO2 gradients, respectively. In situ XRD results demonstrated that the 60CPO-40PCFO sample displayed a perfect structural stability in air as well as CO2-containing atmosphere. Thus, low-cost, Co-free and Sr-free 60CPO-40PCFO has high CO2 stability and is economical and environmental friendly since the expensive and volatile element Co was replaced by Fe and Sr was waived since it easily forms carbonates.
△ Less
Submitted 3 July, 2019;
originally announced July 2019.
-
A Study of the Numerical Stability of an ImEx Scheme with Application to the Poisson-Nernst-Planck Equations
Authors:
M. C. Pugh,
D. Yan,
F. P. Dawson
Abstract:
The Poisson-Nernst-Planck equations with generalized Frumkin-Butler-Volmer boundary conditions (PNP-FBV) describe ion transport with Faradaic reactions and have applications in a wide variety of fields. Using an adaptive time-stepper based on a second-order variable step-size, semi-implicit, backward differentiation formula (VSSBDF2), we observe that when the underlying dynamics is one that would…
▽ More
The Poisson-Nernst-Planck equations with generalized Frumkin-Butler-Volmer boundary conditions (PNP-FBV) describe ion transport with Faradaic reactions and have applications in a wide variety of fields. Using an adaptive time-stepper based on a second-order variable step-size, semi-implicit, backward differentiation formula (VSSBDF2), we observe that when the underlying dynamics is one that would have the solutions converge to a steady state solution, the adaptive time-stepper produces solutions that "nearly" converge to the steady state and that, simultaneously, the time-step sizes stabilize at a limiting size $dt_\infty$. Linearizing the SBDF2 scheme about the steady state solution, we demonstrate that the linearized scheme is conditionally stable and that this is the cause of the adaptive time-stepper's behaviour. Mesh-refinement, as well as a study of the eigenvectors corresponding to the critical eigenvalues, demonstrate that the conditional stability is not due to a time-step constraint caused by high-frequency contributions. We study the stability domain of the linearized scheme and find that it can have corners as well as jump discontinuities.
△ Less
Submitted 22 June, 2020; v1 submitted 3 May, 2019;
originally announced May 2019.
-
A Two-Dimensional Resistor Network Model for Transition-Edge Sensors with Normal Metal Features
Authors:
Daikang Yan,
Lisa M. Gades,
Tejas Guruswamy,
Antonino Miceli,
Umeshkumar M. Patel,
Orlando Quaranta
Abstract:
Transition-edge sensors (TESs) can be used in high-resolution photon detection, exploiting the steep slope of the resistance in the superconducting-to-normal transition edge. Normal metal bars on the TES film are commonly used to engineer its transition shape, namely the dependence of resistance on temperature and current. This problem has been studied in one dimension, however until now, there ha…
▽ More
Transition-edge sensors (TESs) can be used in high-resolution photon detection, exploiting the steep slope of the resistance in the superconducting-to-normal transition edge. Normal metal bars on the TES film are commonly used to engineer its transition shape, namely the dependence of resistance on temperature and current. This problem has been studied in one dimension, however until now, there have been no predictive models of the influence of two-dimensional (2-D) normal metal features on the TES transition shape. In this work, we approach this problem by treating the TES as a 2-D network of resistors, the values of which are based on the two-fluid model. We present a study of the behavior of devices with different 2-D geometric features. Our 2-D network model is capable of predicting how typical TES geometry parameters, such as number of bars, bar spacing, and overall dimensions, influence device behavior and thus is a powerful tool to guide the engineering of new TES devices.
△ Less
Submitted 14 March, 2019;
originally announced March 2019.
-
Modelling a Transition-Edge Sensor X-ray Microcalorimeter Linear Array for Compton Profile Measurements and Energy Dispersive Diffraction
Authors:
Daikang Yan,
Lisa M. Gades,
Tejas Guruswamy,
Umeshkumar M. Patel,
Orlando Quaranta,
Antonino Miceli
Abstract:
Transition-edge sensors are a type of superconducting detector that offers high energy resolution based on their sharp resistance-temperature feature in the superconducting-to-normal transition. TES X-ray microcalorimeters have typically been designed and used for spectroscopic applications. In this work, we present a design optimization for a TES X-ray microcalorimeter array for high-energy scatt…
▽ More
Transition-edge sensors are a type of superconducting detector that offers high energy resolution based on their sharp resistance-temperature feature in the superconducting-to-normal transition. TES X-ray microcalorimeters have typically been designed and used for spectroscopic applications. In this work, we present a design optimization for a TES X-ray microcalorimeter array for high-energy scattering and diffraction measurements. In particular, Compton scattering provides information about the electron momentum distribution, while energy dispersive diffraction provides structural information about dense engineering materials. Compton scattering and energy dispersive diffraction experiments must be conducted in the very hard X-ray regime (~ 100 keV), demanding a high X-ray stop** power in the detector; therefore, an absorber with a large heat capacity is needed in conjunction with the TES. In addition, both applications would benefit from an array composed of parallel strips. We present a design for a TES X-ray microcalorimeter optimized for such applications. In particular, we model the longitudinal position dependence due to the finite thermal diffusion time in the absorber.
△ Less
Submitted 22 March, 2019; v1 submitted 26 February, 2019;
originally announced February 2019.
-
Electromagnetically Induced Transparency of Interacting Rydberg Atoms with Two-Body dephasing
Authors:
Dong Yan,
Binbin Wang,
Zhengyang Bai,
Weibin Li
Abstract:
We study electromagnetically induced transparency of a ladder type configuration in ultracold atomic gases, where the upper level is an electronically highly excited Rydberg state. The strong two-body interaction in the Rydberg state leads to the excitation blockade, where all but one atoms are shifted out of resonance such that the transmission of the probe light is affected. We show that molecul…
▽ More
We study electromagnetically induced transparency of a ladder type configuration in ultracold atomic gases, where the upper level is an electronically highly excited Rydberg state. The strong two-body interaction in the Rydberg state leads to the excitation blockade, where all but one atoms are shifted out of resonance such that the transmission of the probe light is affected. We show that molecular coupling in the Rydberg state causes an effective, two-body dephasing. The presence of the two-body dephasing leads to a similar blockade effect. Hence the overall blockade effect is enhanced by the two-body dephasing. Through numerical and approximately analytical calculations, we find that the transmission is reduced drastically by the presence of two-body dephasing in the transparent window, which is accompanied by strong photon-photon anti-bunching. Around the Autler-Townes splitting, the photon bunching is amplified by the two-body dephasing.
△ Less
Submitted 26 January, 2020; v1 submitted 20 February, 2019;
originally announced February 2019.
-
The cellular ROS-scavenging function, a key factor determining the specific vulnerability of cancer cells to cold atmospheric plasma in vitro
Authors:
Dayun Yan,
Jonathan H. Sherman,
Jerome Canady,
Barry Trink,
Michael Keidar
Abstract:
Cold atmospheric plasma (CAP) has shown its promising application in cancer treatment both in vitro and in vivo. However, the anti-cancer mechanism is still largely unknown. CAP may kill cancer cells via triggering the rise of intracellular ROS, DNA damage, mitochondrial damage, or cellular membrane damage. While, the specific vulnerability of cancer cells to CAP has been observed, the underlying…
▽ More
Cold atmospheric plasma (CAP) has shown its promising application in cancer treatment both in vitro and in vivo. However, the anti-cancer mechanism is still largely unknown. CAP may kill cancer cells via triggering the rise of intracellular ROS, DNA damage, mitochondrial damage, or cellular membrane damage. While, the specific vulnerability of cancer cells to CAP has been observed, the underlying mechanism of such cell-based specific vulnerability to CAP is completely unknown. Here, through the comparison of CAP treatment and H2O2 treatment on 10 different cancer cell lines in vitro, we observed that the H2O2 consumption speed by cancer cells was strongly correlated to the cytotoxicity of CAP treatment on cancer cells. Cancer cells that clear extracellular H2O2 more quickly are more resistant to the cytotoxicity of CAP treatment. This finding strongly indicates that the anti-oxidant system in cancer cells play a key role in the specific vulnerability of cancer cells to CAP treatment in vitro.
△ Less
Submitted 24 November, 2017;
originally announced November 2017.
-
Microstructure analysis of bismuth absorbers for transition-edge sensor X-ray microcalorimeters
Authors:
Daikang Yan,
Ralu Divan,
Lisa M. Gades,
Peter Kenesei,
Timothy J. Madden,
Antonino Miceli,
Jun-Sang Park,
Umeshkumar M. Patel,
Orlando Quaranta,
Hemant Sharma,
Douglas A. Bennett,
William B. Doriese,
Joseph W. Fowler,
Johnathon Gard,
James Hays-Wehle,
Kelsey M. Morgan,
Daniel R. Schmidt,
Daniel S. Swetz,
Joel N. Ullom
Abstract:
Transition-edge sensors (TESs) as microcalorimeters offer high resolving power, owning to their sharp response and low operating temperature. In the hard X-ray regime and above, the demand for high quantum-efficiency requires the use of absorbers. Bismuth (Bi), owing to its low heat carrier density and high X-ray stop** power, has been widely used as an absorber material for TESs. However, disti…
▽ More
Transition-edge sensors (TESs) as microcalorimeters offer high resolving power, owning to their sharp response and low operating temperature. In the hard X-ray regime and above, the demand for high quantum-efficiency requires the use of absorbers. Bismuth (Bi), owing to its low heat carrier density and high X-ray stop** power, has been widely used as an absorber material for TESs. However, distinct spectral responses have been observed for Bi absorbers deposited via evaporation versus electroplating. Evaporated Bi absorbers are widely observed to have a non-Gaussian tail on the low energy side of measured spectra. In this study, we fabricated Bi absorbers via these two methods, and performed microstructure analysis using scanning electron microscopy (SEM) and X-ray diffraction microscopy. The two types of material showed the same crystallographic structure, but the grain size of the evaporated Bi was about 40 times smaller than that of the electroplated Bi. This distinction in grain size is likely to be the cause of their different spectral responses.
△ Less
Submitted 6 November, 2017;
originally announced November 2017.
-
Eliminating the non-Gaussian spectral response of X-ray absorbers for transition-edge sensors
Authors:
Daikang Yan,
Ralu Divan,
Lisa M. Gades,
Peter Kenesei,
Timothy J. Madden,
Antonino Miceli,
Jun-Sang Park,
Umeshkumar M. Patel,
Orlando Quaranta,
Hemant Sharma,
Douglas A. Bennett,
William B. Doriese,
Joseph W. Fowler,
Johnathon Gard,
James Hays-Wehle,
Kelsey M. Morgan,
Daniel R. Schmidt,
Daniel S. Swetz,
Joel N. Ullom
Abstract:
Transition-edge sensors (TES) as microcalorimeters for high-energy-resolution X-ray spectroscopy are often fabricated with an absorber made of materials with high Z (for X-ray stop** power) and low heat capacity (for high resolving power). Bismuth represents one of the most compelling options. TESs with evaporated bismuth absorbers have shown spectra with undesirable and unexplained low-energy t…
▽ More
Transition-edge sensors (TES) as microcalorimeters for high-energy-resolution X-ray spectroscopy are often fabricated with an absorber made of materials with high Z (for X-ray stop** power) and low heat capacity (for high resolving power). Bismuth represents one of the most compelling options. TESs with evaporated bismuth absorbers have shown spectra with undesirable and unexplained low-energy tails. We have developed TESs with electroplated bismuth absorbers over a gold layer that are not afflicted by this problem and that retain the other positive aspects of this material. To better understand these phenomena, we have studied a series of TESs with gold, gold/evaporated bismuth, and gold/electroplated bismuth absorbers, fabricated on the same die with identical thermal coupling. We show that bismuth morphology is linked to the spectral response of X-ray TES microcalorimeters.
△ Less
Submitted 28 August, 2017;
originally announced August 2017.
-
The Strong Cell-based Hydrogen Peroxide Generation Triggered by Cold Atmospheric Plasma
Authors:
Dayun Yan,
Haitao Cui,
Wei Zhu,
Annie Talbot,
Lijie Grace Zhang,
Jonathan H. Sherman,
Michael Keidar
Abstract:
Hydrogen peroxide (H2O2) is an important signaling molecule in cancer cells. However, the significant secretion of H2O2 by cancer cells have been rarely observed. Cold atmospheric plasma (CAP) is a near room temperature ionized gas composed of neutral particles, charged particles, reactive species, and electrons. Here, we first demonstrated that breast cancer cells and pancreatic adenocarcinoma ce…
▽ More
Hydrogen peroxide (H2O2) is an important signaling molecule in cancer cells. However, the significant secretion of H2O2 by cancer cells have been rarely observed. Cold atmospheric plasma (CAP) is a near room temperature ionized gas composed of neutral particles, charged particles, reactive species, and electrons. Here, we first demonstrated that breast cancer cells and pancreatic adenocarcinoma cells generated micromolar level H2O2 during just 1 min of direct CAP treatment on these cells. The cell-based H2O2 generation is affected by the medium volume, the cell confluence, as well as the discharge voltage. The application of cold atmospheric plasma (CAP) in the cancer treatment has been intensively investigated over the past decade. Several cellular responses to the CAP treatment have been observed including the consumption of the CAP-originated reactive species, the rise of intracellular reactive oxygen species, the damage on DNA and mitochondria, as well as the activation of apoptotic events. This is a new previously unknown cellular response to CAP, which provides a new prospective to understand the interaction between CAP and cells.
△ Less
Submitted 28 May, 2017;
originally announced July 2017.
-
Adaptive Time-step** Schemes for the Solution of the Poisson-Nernst-Planck Equations
Authors:
David Yan,
M. C. Pugh,
F. P. Dawson
Abstract:
The Poisson-Nernst-Planck equations with generalized Frumkin-Butler-Volmer boundary conditions (PNP-FBV) describe ion transport with Faradaic reactions, and have applications in a number of fields. In this article, we develop an adaptive time-step** scheme for the solution of the PNP-FBV equations based on two time-step** methods: a fully implicit (BDF2) method, and an implicit-explicit (SBDF2…
▽ More
The Poisson-Nernst-Planck equations with generalized Frumkin-Butler-Volmer boundary conditions (PNP-FBV) describe ion transport with Faradaic reactions, and have applications in a number of fields. In this article, we develop an adaptive time-step** scheme for the solution of the PNP-FBV equations based on two time-step** methods: a fully implicit (BDF2) method, and an implicit-explicit (SBDF2) method. We present simulations under both current and voltage boundary conditions and demonstrate the ability to simulate a large range of parameters, including any value of the singular perturbation parameter $ε$. When the underlying dynamics is one that would have the solutions converge to a steady-state solution, we observe that the adaptive time-stepper based on the SBDF2 method produces solutions that ``nearly'' converge to the steady state and that, simultaneously, the time-step sizes stabilize to a limiting size $dt_\infty$. In the companion to this article \cite{YPD_Part2}, we linearize the SBDF2 scheme about the steady-state solution and demonstrate that the linearized scheme is conditionally stable. This conditional stability is the cause of the adaptive time-stepper's behaviour. While the adaptive time-stepper based on the fully-implicit (BDF2) method is not subject to such time-step constraints, the required nonlinear solve yields run times that are significantly longer.
△ Less
Submitted 22 June, 2020; v1 submitted 29 March, 2017;
originally announced March 2017.
-
Collaborative similarity analysis of multilayer developer-project bipartite network
Authors:
Deng-Cheng Yan,
Bing-Hong Wang
Abstract:
To understand the multiple relations between developers and projects on GitHub as a whole, we model them as a multilayer bipartite network and analyze the degree distributions, the nearest neighbors' degree distributions and their correlations with degree, and the collaborative similarity distributions and their correlations with degree. Our results show that all degree distributions have a power-…
▽ More
To understand the multiple relations between developers and projects on GitHub as a whole, we model them as a multilayer bipartite network and analyze the degree distributions, the nearest neighbors' degree distributions and their correlations with degree, and the collaborative similarity distributions and their correlations with degree. Our results show that all degree distributions have a power-law form, especially, the degree distribution of projects in watching layer has double power-law form. Negative correlations between nearest neighbors' degree and degree for both developers and projects are observed in both layers, exhibiting a disassortative mixing pattern. The collaborative similarity of both developers and projects negatively correlates with degree in watching layer, while a positive correlations is observed for developers in forking layer and no obvious correlation is observed for projects in forking layer.
△ Less
Submitted 8 March, 2017;
originally announced March 2017.
-
Temperature dependence of the plastic scintillator detector for DAMPE
Authors:
Zhao-Min Wang,
Yu-Hong Yu,
Zhi-Yu Sun,
Ke Yue,
Duo Yan,
Yong-Jie Zhang,
Yong Zhou,
Fang Fang,
Wen-Xue Huang,
Jun-Ling Chen
Abstract:
The Plastic Scintillator Detector (PSD) is one of the main sub-detectors in the DArk Matter Particle Explorer (DAMPE) project. It will be operated over a large temperature range from -$10$ to $30^{\circ}$C, so the temperature effect of the whole detection system should be studied in detail. The temperature dependence of the PSD system is mainly contributed by the three parts: the plastic scintilla…
▽ More
The Plastic Scintillator Detector (PSD) is one of the main sub-detectors in the DArk Matter Particle Explorer (DAMPE) project. It will be operated over a large temperature range from -$10$ to $30^{\circ}$C, so the temperature effect of the whole detection system should be studied in detail. The temperature dependence of the PSD system is mainly contributed by the three parts: the plastic scintillator bar, the photomultiplier tube (PMT), and the Front End Electronics (FEE). These three parts have been studied in detail and the contribution of each part has been obtained and discussed. The temperature coefficient of the PMT is $-0.320(\pm0.033)\%/^{\circ}$C, and the coefficient of the plastic scintillator bar is $-0.036(\pm0.038)\%/^{\circ}$C. This result means that after subtracting the FEE pedestal, the variation of the signal amplitude of the PMT-scintillator system due to temperature mainly comes from the PMT, and the plastic scintillator bar is not sensitive to temperature over the operating range. Since the temperature effect cannot be ignored, the temperature dependence of the whole PSD has been also studied and a correction has been made to minimize this effect. The correction result shows that the effect of temperature on the signal amplitude of the PSD system can be suppressed.
△ Less
Submitted 11 December, 2016;
originally announced December 2016.
-
Plastic scintillation detectors for precision time-of-flight measurements of relativistic heavy ions
Authors:
Wen-Jian Lin,
Jian-Wei Zhao,
Bao-Hua Sun,
Liu-Chun He,
Wei-** Lin,
Chuan-Ye Liu,
Isao Tanihata,
Satoru Terashima,
Yi Tian,
Feng Wang,
Meng Wang,
Guang-Xin Zhang,
Xue-Heng Zhang,
Li-Hua Zhu,
Li-Min Duan,
Rong-Jiang Hu,
Zhong Liu,
Chen-Gui Lu,
Pei-Pei Ren,
Li-Na Sheng,
Zhi-Yu Sun,
Shi-Tao Wang,
Tao-Feng Wang,
Zhi-Guo Xu,
Duo Yan
, et al. (2 additional authors not shown)
Abstract:
Plastic scintillation detectors for Time-of-Flight (TOF) measurements are almost essential for event-by-event identification of relativistic rare isotopes. In this work, a pair of plastic scintillation detectors of 50 $\times$ 50 $\times$ 3$^{t}$ mm$^3$ and 80 $\times$ 100 $\times$ 3$^{t}$ mm$^3$ have been set up at the external target facility (ETF), Institute of Modern Physics. Their time, energ…
▽ More
Plastic scintillation detectors for Time-of-Flight (TOF) measurements are almost essential for event-by-event identification of relativistic rare isotopes. In this work, a pair of plastic scintillation detectors of 50 $\times$ 50 $\times$ 3$^{t}$ mm$^3$ and 80 $\times$ 100 $\times$ 3$^{t}$ mm$^3$ have been set up at the external target facility (ETF), Institute of Modern Physics. Their time, energy and position responses are measured with $^{18}$O primary beam at 400 MeV/nucleon. After the off-line walk-effect and position corrections, the time resolution of the two detectors are determined to be 27 ps ($σ$) and 36 ps ($σ$), respectively. Both detectors have nearly the same energy resolution of 3$\%$ ($σ$) and position resolution of 2 mm ($σ$). The detectors have been used successfully in nuclear reaction cross section measurements, and will be be employed for upgrading RIBLL2 beam line at IMP as well as for the high energy branch at HIAF.
△ Less
Submitted 27 September, 2016;
originally announced September 2016.
-
Theory of linear sweep voltammetry with diffuse charge: unsupported electrolytes, thin films, and leaky membranes
Authors:
David Yan,
Martin Z. Bazant,
P. M. Biesheuvel,
Mary C. Pugh,
Francis P. Dawson
Abstract:
Linear sweep and cyclic voltammetry techniques are important tools for electrochemists and have a variety of applications in engineering. Voltammetry has classically been treated with the Randles-Sevcik equation, which assumes an electroneutral supported electrolyte. In this paper, we provide a comprehensive mathematical theory of voltammetry in electrochemical cells with unsupported electrolytes…
▽ More
Linear sweep and cyclic voltammetry techniques are important tools for electrochemists and have a variety of applications in engineering. Voltammetry has classically been treated with the Randles-Sevcik equation, which assumes an electroneutral supported electrolyte. In this paper, we provide a comprehensive mathematical theory of voltammetry in electrochemical cells with unsupported electrolytes and for other situations where diffuse charge effects play a role, and present analytical and simulated solutions of the time-dependent Poisson-Nernst-Planck (PNP) equations with generalized Frumkin-Butler-Volmer (FBV) boundary conditions for a 1:1 electrolyte and a simple reaction. Using these solutions, we construct theoretical and simulated currentvoltage curves for liquid and solid thin films, membranes with fixed background charge, and cells with blocking electrodes. The full range of dimensionless parameters is considered, including the dimensionless Debye screening length (scaled to the electrode separation), Damkohler number (ratio of characteristic diffusion and reaction times) and dimensionless sweep rate (scaled to the thermal voltage per diffusion time). The analysis focuses on the coupling of Faradaic reactions and diffuse charge dynamics, although capacitive charging of the electrical double layers (EDL) is also studied, for early time transients at reactive electrodes and for non-reactive blocking electrodes. Our work highlights cases where diffuse charge effects are important in the context of voltammetry, and illustrates which regimes can be approximated using simple analytical expressions and which require more careful consideration.
△ Less
Submitted 15 January, 2017; v1 submitted 24 August, 2016;
originally announced August 2016.
-
Defect-free Perpendicular Diblock Copolymer Films: The Synergistic Effect of Surface Topography and Chemistry
Authors:
Xingkun Man,
Pan Zhou,
Jiuzhou Tang,
Dadong Yan,
David Andelman
Abstract:
We propose a direct self-assembly mechanism towards obtaining defect-free perpendicular lamellar phases of diblock copolymer (BCP) thin films. In our numerical study, a thin BCP film having a flat top surface is casted on a uni-directional corrugated solid substrate. The substrate is treated chemically and has a weak preference toward one of the two BCP components. Employing self-consistent field…
▽ More
We propose a direct self-assembly mechanism towards obtaining defect-free perpendicular lamellar phases of diblock copolymer (BCP) thin films. In our numerical study, a thin BCP film having a flat top surface is casted on a uni-directional corrugated solid substrate. The substrate is treated chemically and has a weak preference toward one of the two BCP components. Employing self-consistent field theory (SCFT), we find that there is an enhanced synergy between two substrate characteristics: its topography (geometrical roughness) combined with a weak surface preference. This synergy produces the desired perpendicular lamellar phase with perfect inplane ordering. Defect-free BCP lamellar phases are reproducible for several random initial states, and are obtained for a range of substrate roughness and chemical characteristics, even for a uni-directional multi-mode substrate roughness. Our theoretical study suggests possible experiments that will explore the interplay between uni-directional substrate corrugation and chemical surface treatment. It may lead to viable and economical ways of obtaining BCP films with defect-free lateral alignment.
△ Less
Submitted 20 August, 2016;
originally announced August 2016.
-
Processing of X-ray Microcalorimeter Data with Pulse Shape Variation using Principal Component Analysis
Authors:
Daikang Yan,
Thomas Cecil,
Lisa Gades,
Chris Jacobsen,
Timothy Madden,
Antonino Miceli
Abstract:
We present a method using principal component analysis (PCA) to process x-ray pulses with severe shape variation where traditional optimal filter methods fail. We demonstrate that PCA is able to noise-filter and extract energy information from x-ray pulses despite their different shapes. We apply this method to a dataset from an x-ray thermal kinetic inductance detector which has severe pulse shap…
▽ More
We present a method using principal component analysis (PCA) to process x-ray pulses with severe shape variation where traditional optimal filter methods fail. We demonstrate that PCA is able to noise-filter and extract energy information from x-ray pulses despite their different shapes. We apply this method to a dataset from an x-ray thermal kinetic inductance detector which has severe pulse shape variation arising from position-dependent absorption.
△ Less
Submitted 7 January, 2016;
originally announced January 2016.
-
Design and construction of a multi-layer CsI(Tl) telescope for high-energy reaction studies
Authors:
D. Yan,
Z. Y. Sun,
K. Yue,
S. T. Wang,
X. H. Zhang,
Y. H. Yu,
J. L. Chen,
S. W. Tang,
F. Fang,
Y. Zhou,
Y. Sun,
Z. M. Wang,
Y. Z. Sun
Abstract:
A prototype of a new CsI(Tl) telescope, which will be used in the reaction studies of light isotopes with energy of several hundred AMeV, has been constructed and tested at the Institute of Modern Physics, Chinese Academy of Sciences. The telescope has a multi-layer structure and the range information will be obtained to improve the particle identification performance. This prototype has seven lay…
▽ More
A prototype of a new CsI(Tl) telescope, which will be used in the reaction studies of light isotopes with energy of several hundred AMeV, has been constructed and tested at the Institute of Modern Physics, Chinese Academy of Sciences. The telescope has a multi-layer structure and the range information will be obtained to improve the particle identification performance. This prototype has seven layers of different thickness. A 5.0% (FWHM) energy resolution has been extracted for one of the layers in a beam test experiment. Obvious improvement for the identification of $^{14}$O and $^{15}$O isotopes was achieved by using the range information.
△ Less
Submitted 19 November, 2015;
originally announced November 2015.
-
A large area plastic scintillation detector with 4-corner-readout
Authors:
Shu-wen Tang,
Yu-hong Yu,
Yong Zhou,
Zhi-yu Sun,
Xue-heng Zhang,
Shi-tao Wang,
Ke Yue,
Long-xiang Liu,
Fang Fang,
Duo Yan,
Yu Sun,
Zhao-min Wang
Abstract:
A 760 $\times$ 760 $\times$ 30 mm$^3$ plastic scintillation detector viewed by photomultiplier tubes (PMTs) from four corners has been developed, and the detector has been tested with cosmic rays and $γ$ rays. A position-independent effective time T$_{eff}$ has been found, indicating this detector can be used as a TOF detector. The hit position can also be reconstructed by the time from four corne…
▽ More
A 760 $\times$ 760 $\times$ 30 mm$^3$ plastic scintillation detector viewed by photomultiplier tubes (PMTs) from four corners has been developed, and the detector has been tested with cosmic rays and $γ$ rays. A position-independent effective time T$_{eff}$ has been found, indicating this detector can be used as a TOF detector. The hit position can also be reconstructed by the time from four corners. A TOF resolution of 236 ps and a position resolution of 48 mm have been achieved, and the detection efficiency has also been investigated.
△ Less
Submitted 25 August, 2015; v1 submitted 23 August, 2015;
originally announced August 2015.
-
Electromagnetic response of a highly granular hadronic calorimeter
Authors:
C. Adloff,
J. Blaha,
J. -J. Blaising,
C. Drancourt,
A. Espargilière,
R. Gaglione,
N. Geffroy,
Y. Karyotakis,
J. Prast,
G. Vouters,
K. Francis,
J. Repond,
J. Smith,
L. Xia,
E. Baldolemar,
J. Li,
S. T. Park,
M. Sosebee,
A. P. White,
J. Yu,
Y. Mikami,
N. K. Watson T. Goto,
G. Mavromanolakis,
M. A. Thomson,
D. R. Ward W. Yan
, et al. (142 additional authors not shown)
Abstract:
The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the hadronic calorimeter, one option is a highly granular sampling calorimeter with steel as absorber and scintillator layers as active material. High granularity is obtained by segmenting the scintillator into small tiles individuall…
▽ More
The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the hadronic calorimeter, one option is a highly granular sampling calorimeter with steel as absorber and scintillator layers as active material. High granularity is obtained by segmenting the scintillator into small tiles individually read out via silicon photo-multipliers (SiPM).
A prototype has been built, consisting of thirty-eight sensitive layers, segmented into about eight thousand channels. In 2007 the prototype was exposed to positrons and hadrons using the CERN SPS beam, covering a wide range of beam energies and incidence angles. The challenge of cell equalization and calibration of such a large number of channels is best validated using electromagnetic processes.
The response of the prototype steel-scintillator calorimeter, including linearity and uniformity, to electrons is investigated and described.
△ Less
Submitted 8 June, 2011; v1 submitted 20 December, 2010;
originally announced December 2010.
-
Contour-Variable Model of Constitutive Equations for Polymer Melts
Authors:
Shuanhu Qi,
Shuang Yang,
Dadong Yan
Abstract:
Based on a modified expression of the rate of the convective constraint release, we present a new contour-variable model of constitutive equations in which the non-uniform segmental stretch and the non-Gaussian chain statistical treatment of the single chain are considered to describe the polymer chain dynamics and the rheological behavior of an entangled system composed of linear polymer chains…
▽ More
Based on a modified expression of the rate of the convective constraint release, we present a new contour-variable model of constitutive equations in which the non-uniform segmental stretch and the non-Gaussian chain statistical treatment of the single chain are considered to describe the polymer chain dynamics and the rheological behavior of an entangled system composed of linear polymer chains. The constitutive equations are solved numerically in the cases of steady shear and transient start-up of steady shear. The results indicate that the orientation and stretch, as well as the tube survival probability, have strong dependence on the chain contour variable, especially in the high-shear-rate region. However, the inclusion of the non-uniform features in the constitutive models has little modification comparing with the uniform models in determining the rheological properties both qualitatively and quantitatively.
△ Less
Submitted 30 July, 2009;
originally announced July 2009.