-
Laser-scanning optical-frequency-comb microscopy for multimodal imaging
Authors:
Shimpei Kajiwara,
Eiji Hase,
Shota Nakano,
Keishiro Ootani,
Tomoya Okabe,
Hidenori Koresawa,
Akifumi Asahara,
Kazumichi Yoshii,
Hirotsugu Yamamoto,
Kaoru Minoshima,
Takeshi Yasui,
Takeo Minamikawa
Abstract:
We introduce a novel laser-scanning optical microscopy technique that employs optical-frequency-comb (OFC) lasers. This method facilitates multimodal spectroscopic imaging by analyzing interferograms produced via a dual-comb spectroscopic approach. Such interferograms capture comprehensive light information, including amplitude, phase, polarization, frequency, and time of flight information, enabl…
▽ More
We introduce a novel laser-scanning optical microscopy technique that employs optical-frequency-comb (OFC) lasers. This method facilitates multimodal spectroscopic imaging by analyzing interferograms produced via a dual-comb spectroscopic approach. Such interferograms capture comprehensive light information, including amplitude, phase, polarization, frequency, and time of flight information, enabling multimodal imaging from a single measurement. We demonstrate the potential of this technique across several spectroscopic imaging applications.
△ Less
Submitted 28 May, 2024;
originally announced May 2024.
-
LIGO operates with quantum noise below the Standard Quantum Limit
Authors:
Wenxuan Jia,
Victoria Xu,
Kevin Kuns,
Masayuki Nakano,
Lisa Barsotti,
Matthew Evans,
Nergis Mavalvala,
Rich Abbott,
Ibrahim Abouelfettouh,
Rana Adhikari,
Alena Ananyeva,
Stephen Appert,
Koji Arai,
Naoki Aritomi,
Stuart Aston,
Matthew Ball,
Stefan Ballmer,
David Barker,
Beverly Berger,
Joseph Betzwieser,
Dripta Bhattacharjee,
Garilynn Billingsley,
Nina Bode,
Edgard Bonilla,
Vladimir Bossilkov
, et al. (146 additional authors not shown)
Abstract:
Precision measurements of space and time, like those made by the detectors of the Laser Interferometer Gravitational-wave Observatory (LIGO), are often confronted with fundamental limitations imposed by quantum mechanics. The Heisenberg uncertainty principle dictates that the position and momentum of an object cannot both be precisely measured, giving rise to an apparent limitation called the Stan…
▽ More
Precision measurements of space and time, like those made by the detectors of the Laser Interferometer Gravitational-wave Observatory (LIGO), are often confronted with fundamental limitations imposed by quantum mechanics. The Heisenberg uncertainty principle dictates that the position and momentum of an object cannot both be precisely measured, giving rise to an apparent limitation called the Standard Quantum Limit (SQL). Reducing quantum noise below the SQL in gravitational-wave detectors, where photons are used to continuously measure the positions of freely falling mirrors, has been an active area of research for decades. Here we show how the LIGO A+ upgrade reduced the detectors' quantum noise below the SQL by up to 3 dB while achieving a broadband sensitivity improvement, more than two decades after this possibility was first presented.
△ Less
Submitted 22 April, 2024;
originally announced April 2024.
-
Coherent linking between confocal amplitude image and confocal phase image in dual-comb microscopy
Authors:
Takahiko Mizuno,
Takuya Tsuda,
Eiji Hase,
Hirotsugu Yamamoto,
Takeo Minamikawa,
Takeshi Yasui
Abstract:
This paper presents a coherent linking approach between confocal amplitude and confocal phase images acquired using dual-comb microscopy (DCM). DCM combines the advantages of confocal laser microscopy and quantitative phase microscopy, offering high axial resolution and scan-less imaging capability. By exploiting the coherence between confocal amplitude and phase images within the same DCM system,…
▽ More
This paper presents a coherent linking approach between confocal amplitude and confocal phase images acquired using dual-comb microscopy (DCM). DCM combines the advantages of confocal laser microscopy and quantitative phase microscopy, offering high axial resolution and scan-less imaging capability. By exploiting the coherence between confocal amplitude and phase images within the same DCM system, we accurately determine the number of phase unwrap** iterations, eliminating phase wrap** ambiguity. The method is demonstrated with samples having micrometer-range optical thickness and nanometer-scale surface roughness. The results showcase an expanded axial dynamic range, ranging from micrometers to millimeters, while maintaining nanometer-level axial resolution. This coherently linked DCM imaging technique enables the simultaneous acquisition of absolute phase information, enhancing its potential for high-axial-resolution imaging in a wide range of applications.
△ Less
Submitted 5 August, 2023;
originally announced August 2023.
-
The evolution of cooperation and diversity by integrated indirect reciprocity
Authors:
Tatsuya Sasaki,
Satoshi Uchida,
Isamu Okada,
Hitoshi Yamamoto
Abstract:
Indirect reciprocity is one of the major mechanisms for the evolution of cooperation in human societies. There are two types of indirect reciprocity: upstream and downstream. Cooperation in downstream reciprocity follows the pattern, 'You helped someone, and I will help you'. The direction of cooperation is reversed in upstream reciprocity, which instead follows the pattern, 'You helped me, and I…
▽ More
Indirect reciprocity is one of the major mechanisms for the evolution of cooperation in human societies. There are two types of indirect reciprocity: upstream and downstream. Cooperation in downstream reciprocity follows the pattern, 'You helped someone, and I will help you'. The direction of cooperation is reversed in upstream reciprocity, which instead follows the pattern, 'You helped me, and I will help someone else'. In reality, these two types of indirect reciprocity often occur in combination. However, upstream and downstream reciprocity have mostly been studied theoretically in isolation. Here, we propose a new model that integrates both types. We apply the standard giving-game framework of indirect reciprocity and analyze the model by means of evolutionary game theory. We show that the model can result in the stable coexistence of altruistic reciprocators and free riders in well-mixed populations. We also found that considering inattention in the assessment rule can strengthen the stability of this mixed equilibrium, even resulting in a global attractor. Our results indicate that the cycles of forwarding help and rewarding help need to be established for creating and maintaining diversity and inclusion in a society.
△ Less
Submitted 8 March, 2023;
originally announced March 2023.
-
Simulations of light distribution on new instrumented baffles surrounding Virgo end mirrors
Authors:
A. Macquet,
M. Andrés-Carcasona,
M. Martinez,
Ll-M. Mir,
A. Romero-Rodriguez,
H. Yamamoto
Abstract:
As part of the second phase of Advanced Virgo upgrade program, instrumented baffles are being constructed to be installed around the end mirrors in the main arms, in continuation of what has been implemented for the input mode cleaner end mirror during phase I. These baffles will be equipped with photosensors, allowing for real-time monitoring of the stray light around the mirrors. In this paper,…
▽ More
As part of the second phase of Advanced Virgo upgrade program, instrumented baffles are being constructed to be installed around the end mirrors in the main arms, in continuation of what has been implemented for the input mode cleaner end mirror during phase I. These baffles will be equipped with photosensors, allowing for real-time monitoring of the stray light around the mirrors. In this paper, we present optical simulations of the light distribution in the detector main cavities to assess the ability of the sensors to effectively monitor misalignment and defects on the mirrors surface and to play a role in the pre-alignment of the interferometer.
△ Less
Submitted 3 March, 2023; v1 submitted 24 October, 2022;
originally announced October 2022.
-
Broadband control of group delay using the Brewster effect in metafilms
Authors:
Yasuhiro Tamayama,
Hiromu Yamamoto
Abstract:
We propose and verify a method for controlling the frequency dependence of the group delay of electromagnetic waves over a broad frequency range using the Brewster effect in single-layer metamaterials with finite thickness, here referred to as metafilms. When the metafilm's reflectance vanishes regardless of the incident frequency, the group delay can be large near its resonance frequency while ma…
▽ More
We propose and verify a method for controlling the frequency dependence of the group delay of electromagnetic waves over a broad frequency range using the Brewster effect in single-layer metamaterials with finite thickness, here referred to as metafilms. When the metafilm's reflectance vanishes regardless of the incident frequency, the group delay can be large near its resonance frequency while maintaining the transmittance close to unity regardless of the incident frequency. Furthermore, when several reflectionless metafilms are stacked together, the total group delay should be given as the sum of the individual group delays. In this study, we realize reflectionless metafilms by arranging the meta-atoms so that the Brewster effect occurs regardless of the incident frequency. We evaluate in numerical simulations and experiments the frequency dependence of the transmittance and of the group delay of a three-layer metamaterial composed of reflectionless metafilms with different resonance frequencies, and find that the total transmittance and group delay of this metamaterial agree respectively with the product of the transmittances and the sum of the group delays of the constituent metafilms.
△ Less
Submitted 14 July, 2022;
originally announced August 2022.
-
On the definition of chirality and enantioselective fields
Authors:
Jun-ichiro Kishine,
Hiroaki Kusunose,
Hiroshi M. Yamamoto
Abstract:
In solid state physics, any symmetry breaking is known to be associated with emergence of an order parameter. However, the order parameter for molecular and crystal chirality, which is a consequence of parity and mirror symmetry breaking, has not been known since its discovery. In this article, the authors show that the order parameter for chirality can be defined by electric toroidal monopole G_0…
▽ More
In solid state physics, any symmetry breaking is known to be associated with emergence of an order parameter. However, the order parameter for molecular and crystal chirality, which is a consequence of parity and mirror symmetry breaking, has not been known since its discovery. In this article, the authors show that the order parameter for chirality can be defined by electric toroidal monopole G_0. By this definition, one becomes able to discuss external filed that can distinguish two different enantiomers only by physical fields. In addition, dynamics and fluctuations of the order parameter G_0 can be discussed, with which one can obtain fruitful insights on a spin filtering effect called CISS (Chirality Induced Spin Selectivity). Emergence of time-reversal-odd dipole M_z by time propagation of G_0 quantities is discussed to explain the enantioselective effect (chiral resolution) at a ferromagnetic surface.
△ Less
Submitted 18 August, 2022; v1 submitted 11 August, 2022;
originally announced August 2022.
-
The International Linear Collider: Report to Snowmass 2021
Authors:
Alexander Aryshev,
Ties Behnke,
Mikael Berggren,
James Brau,
Nathaniel Craig,
Ayres Freitas,
Frank Gaede,
Spencer Gessner,
Stefania Gori,
Christophe Grojean,
Sven Heinemeyer,
Daniel Jeans,
Katja Kruger,
Benno List,
Jenny List,
Zhen Liu,
Shinichiro Michizono,
David W. Miller,
Ian Moult,
Hitoshi Murayama,
Tatsuya Nakada,
Emilio Nanni,
Mihoko Nojiri,
Hasan Padamsee,
Maxim Perelstein
, et al. (487 additional authors not shown)
Abstract:
The International Linear Collider (ILC) is on the table now as a new global energy-frontier accelerator laboratory taking data in the 2030s. The ILC addresses key questions for our current understanding of particle physics. It is based on a proven accelerator technology. Its experiments will challenge the Standard Model of particle physics and will provide a new window to look beyond it. This docu…
▽ More
The International Linear Collider (ILC) is on the table now as a new global energy-frontier accelerator laboratory taking data in the 2030s. The ILC addresses key questions for our current understanding of particle physics. It is based on a proven accelerator technology. Its experiments will challenge the Standard Model of particle physics and will provide a new window to look beyond it. This document brings the story of the ILC up to date, emphasizing its strong physics motivation, its readiness for construction, and the opportunity it presents to the US and the global particle physics community.
△ Less
Submitted 16 January, 2023; v1 submitted 14 March, 2022;
originally announced March 2022.
-
Scattering Loss in Precision Metrology due to Mirror Roughness
Authors:
Yehonathan Drori,
Johannes Eichholz,
Tega Edo,
Hiro Yamamoto,
Yutaro Enomoto,
Gautam Venugopalan,
Koji Arai,
Rana X Adhikari
Abstract:
Optical losses degrade the sensitivity of laser interferometric instruments. They reduce the number of signal photons and introduce technical noise associated with diffuse light. In quantum-enhanced metrology, they break the entanglement between correlated photons. Such decoherence is one of the primary obstacles in achieving high levels of quantum noise reduction in precision metrology. In this w…
▽ More
Optical losses degrade the sensitivity of laser interferometric instruments. They reduce the number of signal photons and introduce technical noise associated with diffuse light. In quantum-enhanced metrology, they break the entanglement between correlated photons. Such decoherence is one of the primary obstacles in achieving high levels of quantum noise reduction in precision metrology. In this work, we compare direct measurements of cavity and mirror losses in the Caltech 40m gravitational-wave detector prototype interferometer with numerical estimates obtained from semi-analytic intra-cavity wavefront simulations using mirror surface profile maps. We show a unified approach to estimating the total loss in optical cavities (such as the LIGO gravitational detectors) that will lead towards the engineering of systems with minimum decoherence for quantum-enhanced precision metrology.
△ Less
Submitted 14 January, 2022;
originally announced January 2022.
-
Point Absorber Limits to Future Gravitational-Wave Detectors
Authors:
W. Jia,
H. Yamamoto,
K. Kuns,
A. Effler,
M. Evans,
P. Fritschel,
R. Abbott,
C. Adams,
R. X. Adhikari,
A. Ananyeva,
S. Appert,
K. Arai,
J. S. Areeda,
Y. Asali,
S. M. Aston,
C. Austin,
A. M. Baer,
M. Ball,
S. W. Ballmer,
S. Banagiri,
D. Barker,
L. Barsotti,
J. Bartlett,
B. K. Berger,
J. Betzwieser
, et al. (176 additional authors not shown)
Abstract:
High-quality optical resonant cavities require low optical loss, typically on the scale of parts per million. However, unintended micron-scale contaminants on the resonator mirrors that absorb the light circulating in the cavity can deform the surface thermoelastically, and thus increase losses by scattering light out of the resonant mode. The point absorber effect is a limiting factor in some hig…
▽ More
High-quality optical resonant cavities require low optical loss, typically on the scale of parts per million. However, unintended micron-scale contaminants on the resonator mirrors that absorb the light circulating in the cavity can deform the surface thermoelastically, and thus increase losses by scattering light out of the resonant mode. The point absorber effect is a limiting factor in some high-power cavity experiments, for example, the Advanced LIGO gravitational wave detector. In this Letter, we present a general approach to the point absorber effect from first principles and simulate its contribution to the increased scattering. The achievable circulating power in current and future gravitational-wave detectors is calculated statistically given different point absorber configurations. Our formulation is further confirmed experimentally in comparison with the scattered power in the arm cavity of Advanced LIGO measured by in-situ photodiodes. The understanding presented here provides an important tool in the global effort to design future gravitational wave detectors that support high optical power, and thus reduce quantum noise.
△ Less
Submitted 17 September, 2021;
originally announced September 2021.
-
LIGOs Quantum Response to Squeezed States
Authors:
L. McCuller,
S. E. Dwyer,
A. C. Green,
Haocun Yu,
L. Barsotti,
C. D. Blair,
D. D. Brown,
A. Effler,
M. Evans,
A. Fernandez-Galiana,
P. Fritschel,
V. V. Frolov,
N. Kijbunchoo,
G. L. Mansell,
F. Matichard,
N. Mavalvala,
D. E. McClelland,
T. McRae,
A. Mullavey,
D. Sigg,
B. J. J. Slagmolen,
M. Tse,
T. Vo,
R. L. Ward,
C. Whittle
, et al. (172 additional authors not shown)
Abstract:
Gravitational Wave interferometers achieve their profound sensitivity by combining a Michelson interferometer with optical cavities, suspended masses, and now, squeezed quantum states of light. These states modify the measurement process of the LIGO, VIRGO and GEO600 interferometers to reduce the quantum noise that masks astrophysical signals; thus, improvements to squeezing are essential to furth…
▽ More
Gravitational Wave interferometers achieve their profound sensitivity by combining a Michelson interferometer with optical cavities, suspended masses, and now, squeezed quantum states of light. These states modify the measurement process of the LIGO, VIRGO and GEO600 interferometers to reduce the quantum noise that masks astrophysical signals; thus, improvements to squeezing are essential to further expand our gravitational view of the universe. Further reducing quantum noise will require both lowering decoherence from losses as well more sophisticated manipulations to counter the quantum back-action from radiation pressure. Both tasks require fully understanding the physical interactions between squeezed light and the many components of km-scale interferometers. To this end, data from both LIGO observatories in observing run three are expressed using frequency-dependent metrics to analyze each detector's quantum response to squeezed states. The response metrics are derived and used to concisely describe physical mechanisms behind squeezing's simultaneous interaction with transverse-mode selective optical cavities and the quantum radiation pressure noise of suspended mirrors. These metrics and related analysis are broadly applicable for cavity-enhanced optomechanics experiments that incorporate external squeezing, and -- for the first time -- give physical descriptions of every feature so far observed in the quantum noise of the LIGO detectors.
△ Less
Submitted 25 May, 2021;
originally announced May 2021.
-
Point absorbers in Advanced LIGO
Authors:
Aidan F. Brooks,
Gabriele Vajente,
Hiro Yamamoto,
Rich Abbott,
Carl Adams,
Rana X. Adhikari,
Alena Ananyeva,
Stephen Appert,
Koji Arai,
Joseph S. Areeda,
Yasmeen Asali,
Stuart M. Aston,
Corey Austin,
Anne M. Baer,
Matthew Ball,
Stefan W. Ballmer,
Sharan Banagiri,
David Barker,
Lisa Barsotti,
Jeffrey Bartlett,
Beverly K. Berger,
Joseph Betzwieser,
Dripta Bhattacharjee,
Garilynn Billingsley,
Sebastien Biscans
, et al. (176 additional authors not shown)
Abstract:
Small, highly absorbing points are randomly present on the surfaces of the main interferometer optics in Advanced LIGO. The resulting nano-meter scale thermo-elastic deformations and substrate lenses from these micron-scale absorbers significantly reduces the sensitivity of the interferometer directly though a reduction in the power-recycling gain and indirect interactions with the feedback contro…
▽ More
Small, highly absorbing points are randomly present on the surfaces of the main interferometer optics in Advanced LIGO. The resulting nano-meter scale thermo-elastic deformations and substrate lenses from these micron-scale absorbers significantly reduces the sensitivity of the interferometer directly though a reduction in the power-recycling gain and indirect interactions with the feedback control system. We review the expected surface deformation from point absorbers and provide a pedagogical description of the impact on power build-up in second generation gravitational wave detectors (dual-recycled Fabry-Perot Michelson interferometers). This analysis predicts that the power-dependent reduction in interferometer performance will significantly degrade maximum stored power by up to 50% and hence, limit GW sensitivity, but suggests system wide corrections that can be implemented in current and future GW detectors. This is particularly pressing given that future GW detectors call for an order of magnitude more stored power than currently used in Advanced LIGO in Observing Run 3. We briefly review strategies to mitigate the effects of point absorbers in current and future GW wave detectors to maximize the success of these enterprises.
△ Less
Submitted 25 March, 2021; v1 submitted 14 January, 2021;
originally announced January 2021.
-
Determination of the light exposure on the photodiodes of a new instrumented baffle for the Virgo input mode cleaner end-mirror
Authors:
A. Romero,
A. Allocca,
A. Chiummo,
M. Martinez,
Ll. M. Mir,
H. Yamamoto
Abstract:
As part of the upgrade program of the Advanced Virgo interferometer, the installation of new instrumented baffles surrounding the main test masses is foreseen. As a demonstrator, and to validate the technology, the existing baffle in the area of the input mode cleaner end-mirror will be first replaced by a baffle equipped with photodiodes. This paper presents detailed simulations of the light dist…
▽ More
As part of the upgrade program of the Advanced Virgo interferometer, the installation of new instrumented baffles surrounding the main test masses is foreseen. As a demonstrator, and to validate the technology, the existing baffle in the area of the input mode cleaner end-mirror will be first replaced by a baffle equipped with photodiodes. This paper presents detailed simulations of the light distribution on the input mode cleaner baffle, with the aim to determine the light exposure of the photodiodes under different scenarios of the interferometer operation.
△ Less
Submitted 7 January, 2021; v1 submitted 31 August, 2020;
originally announced August 2020.
-
PDMS microfluidic film for in vitro engineering of mesoscale neuronal networks
Authors:
Taiki Takemuro,
Hideaki Yamamoto,
Shigeo Sato,
Ayumi Hirano-Iwata
Abstract:
Polydimethylsiloxane (PDMS) microfluidic devices have become a standard tool for engineering cells and multicellular networks in vitro. However, the reservoirs, or through-holes where cells access the devices, are usually fabricated manually using a biopsy punch, making it difficult to create a large-scale array of small (<1 mm) reservoirs. Here, we present a fabrication process for a thin-film mi…
▽ More
Polydimethylsiloxane (PDMS) microfluidic devices have become a standard tool for engineering cells and multicellular networks in vitro. However, the reservoirs, or through-holes where cells access the devices, are usually fabricated manually using a biopsy punch, making it difficult to create a large-scale array of small (<1 mm) reservoirs. Here, we present a fabrication process for a thin-film microfluidic device, or a microfluidic film (μFF), containing an array of through-holes. Holes as small as 100 μm by 100 μm spanning 10 mm by 10 mm are characterized. The geometry of the through-holes was precisely defined by the photoresist mould. A challenge in using the μFF for cell culture was air-bubble entrapments in the through-holes, which became more prominent with smaller holes. We show that this issue can be overcome using ethanol-mediated wetting of the PDMS surface, and demonstrate functional recording of cultured neuronal networks grown in μFFs. This technology opens new application of microfluidic devices to mesoscale systems comprised of several tens to hundreds of cells.
△ Less
Submitted 7 August, 2020;
originally announced August 2020.
-
Improving the Robustness of the Advanced LIGO Detectors to Earthquakes
Authors:
Eyal Schwartz,
A Pele,
J Warner,
B Lantz,
J Betzwieser,
K L Dooley,
S Biscans,
M Coughlin,
N Mukund,
R Abbott,
C Adams,
R X Adhikari,
A Ananyeva,
S Appert,
K Arai,
J S Areeda,
Y Asali,
S M Aston,
C Austin,
A M Baer,
M Ball,
S W Ballmer,
S Banagiri,
D Barker,
L Barsotti
, et al. (174 additional authors not shown)
Abstract:
Teleseismic, or distant, earthquakes regularly disrupt the operation of ground--based gravitational wave detectors such as Advanced LIGO. Here, we present \emph{EQ mode}, a new global control scheme, consisting of an automated sequence of optimized control filters that reduces and coordinates the motion of the seismic isolation platforms during earthquakes. This, in turn, suppresses the differenti…
▽ More
Teleseismic, or distant, earthquakes regularly disrupt the operation of ground--based gravitational wave detectors such as Advanced LIGO. Here, we present \emph{EQ mode}, a new global control scheme, consisting of an automated sequence of optimized control filters that reduces and coordinates the motion of the seismic isolation platforms during earthquakes. This, in turn, suppresses the differential motion of the interferometer arms with respect to one another, resulting in a reduction of DARM signal at frequencies below 100\,mHz. Our method greatly improved the interferometers' capability to remain operational during earthquakes, with ground velocities up to 3.9\,$μ\mbox{m/s}$ rms in the beam direction, setting a new record for both detectors. This sets a milestone in seismic controls of the Advanced LIGO detectors' ability to manage high ground motion induced by earthquakes, opening a path for further robust operation in other extreme environmental conditions.
△ Less
Submitted 24 July, 2020;
originally announced July 2020.
-
Diffraction losses of a Fabry-Perot cavity with nonidentical non-spherical mirrors
Authors:
Mikhail V. Poplavskiy,
Andrey B. Matsko,
Hiroaki Yamamoto,
Sergey P. Vyatchanin
Abstract:
Optical cavities with both optimized resonant conditions and high quality factors are important metrological tools. In particular, they are used for laser gravitational wave (GW) detectors. It is necessary to suppress the parametric instability by dam** the resonant conditions of harmful higher order optical modes (HOOM) in order to have high cavity powers in GW detectors. This can be achieved e…
▽ More
Optical cavities with both optimized resonant conditions and high quality factors are important metrological tools. In particular, they are used for laser gravitational wave (GW) detectors. It is necessary to suppress the parametric instability by dam** the resonant conditions of harmful higher order optical modes (HOOM) in order to have high cavity powers in GW detectors. This can be achieved effectively by using non spherical mirrors in symmetric Fabry-Perot (FP) cavities by increasing roundtrip losses of HOOMs. Fabry-Perot cavities in most of the GW detectors have non-identical mirrors to optimize clip** losses and reduce thermal noise by reducing the beam size on one side of the cavity facing to the beam splitter and recycling cavities. We here present a general method to design non spherical non-identical mirrors in non-symmetric FP cavities to damp HOOMs. The proposed design allows to the suppress the loss of the arm power caused by point absorbers on test masses.
△ Less
Submitted 5 May, 2020;
originally announced May 2020.
-
Scan-less full-field fluorescence-lifetime dual-comb microscopy using two-dimensional spectral map** and frequency multiplexing of dual-optical-comb beats
Authors:
Takahiko Mizuno,
Eiji Hase,
Takeo Minamikawa,
Yu Tokizane,
Ryo Oe,
Hidenori Koresawa,
Hirotsugu Yamamoto,
Takeshi Yasui
Abstract:
Fluorescence lifetime imaging microscopy (FLIM) is a powerful tool for quantitative fluorescence imaging because fluorescence lifetime is independent of concentration of fluorescent molecules or excitation/detection efficiency and is robust to photobleaching. However, since FLIM is based on point-to-point measurements, mechanical scanning of a focal spot is needed for forming an image, which hampe…
▽ More
Fluorescence lifetime imaging microscopy (FLIM) is a powerful tool for quantitative fluorescence imaging because fluorescence lifetime is independent of concentration of fluorescent molecules or excitation/detection efficiency and is robust to photobleaching. However, since FLIM is based on point-to-point measurements, mechanical scanning of a focal spot is needed for forming an image, which hampers rapid imaging. In this article, we demonstrate scan-less full-field FLIM based on a one-to-one correspondence between two-dimensional (2D) image pixels and frequency-multiplexed RF signals. A vast number of dual-optical-comb beats between dual optical frequency combs is effectively adopted for 2D spectral map** and high-density frequency multiplexing in radio-frequency region. Bimodal images of fluorescence amplitude and lifetime are obtained with high quantitativeness from amplitude and phase spectra of fluorescence RF comb modes without the need for mechanical scanning. The proposed method will be useful for rapid quantitative fluorescence imaging in life science.
△ Less
Submitted 20 March, 2020;
originally announced March 2020.
-
Characterization of bulk nanobubbles formed by using a porous alumina film with ordered nanopores
Authors:
Teng Ma,
Yasuo Kimura,
Hideaki Yamamoto,
Xingyao Feng,
Ayumi Hirano-Iwata,
Michio Niwano
Abstract:
Gaseous nanobubbles (NBs), with their unique physicochemical properties and promising applications, have become an important research topic. Generation of monodispersed bulk NBs with specified gas content remains a challenge. We developed a simple method for generating bulk NBs, using porous alumina films with ordered straight nano-scaled holes. Different techniques, such as nanoparticle tracking…
▽ More
Gaseous nanobubbles (NBs), with their unique physicochemical properties and promising applications, have become an important research topic. Generation of monodispersed bulk NBs with specified gas content remains a challenge. We developed a simple method for generating bulk NBs, using porous alumina films with ordered straight nano-scaled holes. Different techniques, such as nanoparticle tracking analysis (NTA), atomic force microscopy (AFM), and infrared absorption spectroscopy (IRAS), are used to confirm NB formation. The NTA data demonstrates that the minimum size of the NBs formed is less than 100 nm, which is comparable to the diameter of nanoholes in the porous alumina film. By generating NBs with different gases, including CO2, O2, N2, Ar, and He, we discovered that the minimum size of NBs negatively correlated with the solubility of encapsulated gases in water. Due to the monodispersed size of NBs generated from the highly ordered porous alumina, we determined that NB size is distributed discretely with a uniform increment factor of sqrt(2). To explain the observed characteristic size distribution of NBs, we propose a simple model in which two NBs of the same size are assumed to preferentially coalesce. This characteristic bubble size distribution is useful for elucidating the basic characteristics of nanobubbles, such as the long-term stability of NBs. This distribution can also be used to develop new applications of NBs, for example, nano-scaled reaction fields through bubble coalescence.
△ Less
Submitted 5 March, 2020;
originally announced March 2020.
-
A Cryogenic Silicon Interferometer for Gravitational-wave Detection
Authors:
Rana X Adhikari,
Odylio Aguiar,
Koji Arai,
Bryan Barr,
Riccardo Bassiri,
Garilynn Billingsley,
Ross Birney,
David Blair,
Joseph Briggs,
Aidan F Brooks,
Daniel D Brown,
Huy-Tuong Cao,
Marcio Constancio,
Sam Cooper,
Thomas Corbitt,
Dennis Coyne,
Edward Daw,
Johannes Eichholz,
Martin Fejer,
Andreas Freise,
Valery Frolov,
Slawomir Gras,
Anna Green,
Hartmut Grote,
Eric K Gustafson
, et al. (86 additional authors not shown)
Abstract:
The detection of gravitational waves from compact binary mergers by LIGO has opened the era of gravitational wave astronomy, revealing a previously hidden side of the cosmos. To maximize the reach of the existing LIGO observatory facilities, we have designed a new instrument that will have 5 times the range of Advanced LIGO, or greater than 100 times the event rate. Observations with this new inst…
▽ More
The detection of gravitational waves from compact binary mergers by LIGO has opened the era of gravitational wave astronomy, revealing a previously hidden side of the cosmos. To maximize the reach of the existing LIGO observatory facilities, we have designed a new instrument that will have 5 times the range of Advanced LIGO, or greater than 100 times the event rate. Observations with this new instrument will make possible dramatic steps toward understanding the physics of the nearby universe, as well as observing the universe out to cosmological distances by the detection of binary black hole coalescences. This article presents the instrument design and a quantitative analysis of the anticipated noise floor.
△ Less
Submitted 9 June, 2020; v1 submitted 29 January, 2020;
originally announced January 2020.
-
Optical image amplification in dual-comb microscopy by use of optical-fiber-amplified interferogram
Authors:
Takahiko Mizuno,
Takuya Tsuda,
Eiji Hase,
Yu Tokizane,
Ryo Oe,
Hidenori Koresawa,
Hirotsugu Yamamoto,
Takeo Minamikawa,
Takeshi Yasui
Abstract:
Dual-comb microscopy (DCM), based on a combination of dual-comb spectroscopy (DCS) with two-dimensional spectral encoding (2D-SE), is a promising method for scan-less confocal laser microscopy giving an amplitude and phase image contrast with the confocality. However, signal loss in a 2D-SE optical system hampers increase in image acquisition rate due to decreased signa-to-noise ratio. In this art…
▽ More
Dual-comb microscopy (DCM), based on a combination of dual-comb spectroscopy (DCS) with two-dimensional spectral encoding (2D-SE), is a promising method for scan-less confocal laser microscopy giving an amplitude and phase image contrast with the confocality. However, signal loss in a 2D-SE optical system hampers increase in image acquisition rate due to decreased signa-to-noise ratio. In this article, we demonstrated optical image amplification in DCM with an erbium-doped fiber amplifier (EDFA). Combined use of image-encoded DCS interferogram and EDFA benefits from not only the batch amplification of amplitude and phase images but also significant rejection of amplified spontaneous emission (ASE) background. Effectiveness of the optical-image-amplified DCM is highlighted in the single-shot quantitative nanometer-order surface topography and the real-time movie of polystyrene beads dynamics under water convection. The proposed method will be a powerful tool for real-time observation of surface topography and fast dynamic phenomena.
△ Less
Submitted 20 January, 2020;
originally announced January 2020.
-
Suppression of hypersynchronous network activity in cultured cortical neurons using an ultrasoft silicone scaffold
Authors:
Takuma Sumi,
Hideaki Yamamoto,
Ayumi Hirano-Iwata
Abstract:
The spontaneous activity pattern of cortical neurons in dissociated culture is characterized by burst firing that is highly synchronized among a wide population of cells. The degree of synchrony, however, is excessively higher than that in cortical tissues. Here, we employed polydimethylsiloxane (PDMS) elastomers to establish a novel system for culturing neurons on a scaffold with an elastic modul…
▽ More
The spontaneous activity pattern of cortical neurons in dissociated culture is characterized by burst firing that is highly synchronized among a wide population of cells. The degree of synchrony, however, is excessively higher than that in cortical tissues. Here, we employed polydimethylsiloxane (PDMS) elastomers to establish a novel system for culturing neurons on a scaffold with an elastic modulus resembling brain tissue, and investigated the effect of the scaffold's elasticity on network activity patterns in cultured rat cortical neurons. Using whole-cell patch clamp to assess the scaffold effect on the development of synaptic connections, we found that the amplitude of excitatory postsynaptic current, as well as the frequency of spontaneous transmissions, was reduced in neuronal networks grown on an ultrasoft PDMS with an elastic modulus of 0.5 kPa. Furthermore, the ultrasoft scaffold was found to suppress neural correlations in the spontaneous activity of the cultured neuronal network. The dose of GsMTx-4, an antagonist of stretch-activated cation channels (SACs), required to reduce the generation of the events below 1.0 event/min on PDMS substrates was lower than that for neurons on a glass substrate. This suggests that the difference in the baseline level of SAC activation is a molecular mechanism underlying the alteration in neuronal network activity depending on scaffold stiffness. Our results demonstrate the potential application of PDMS with biomimetic elasticity as cell-culture scaffold for bridging the in vivo-in vitro gap in neuronal systems.
△ Less
Submitted 10 December, 2019;
originally announced December 2019.
-
A Teflon-based system for applying multidirectional voltages to lipid bilayers as a novel platform for membrane proteins
Authors:
Maki Komiya,
Kensaku Kanomata,
Ryo Yokota,
Yusuke Tsuneta,
Madoka Sato,
Daichi Yamaura,
Daisuke Tadaki,
Teng Ma,
Hideaki Yamamoto,
Yuzuru Tozawa,
Albert Marti,
Jordi Madrenas,
Shigeru Kubota,
Fumihiko Hirose,
Michio Niwano,
Ayumi Hirano-Iwata
Abstract:
Artificial bilayer lipid membranes (BLMs), along with patch-clamped membranes, are frequently used for functional analyses of membrane proteins. In both methods, the electric properties of membranes are characterized by only one parameter, namely, transmembrane potential. Here the construction of a novel BLM system was reported, in which membrane voltages can be controlled in a lateral direction i…
▽ More
Artificial bilayer lipid membranes (BLMs), along with patch-clamped membranes, are frequently used for functional analyses of membrane proteins. In both methods, the electric properties of membranes are characterized by only one parameter, namely, transmembrane potential. Here the construction of a novel BLM system was reported, in which membrane voltages can be controlled in a lateral direction in addition to conventional transmembrane direction. A microaperture was fabricated in a Teflon film and Ti electrodes were evaporated around the aperture. BLMs were reproducibly formed in the aperture without being affected by the presence of the electrodes. The application of a lateral voltage induced no significant changes in the electric properties of the BLMs, such as baseline current, transmembrane resistance, and transmembrane capacitance. In contrast, lateral voltages clearly affected the activities of biological ion channels, suggesting that the lateral voltage might be a useful parameter for analyzing channel activities. The present Teflon-based system in which multidirectional voltages can be applied to BLMs represent a promising platform for the analysis of underlying functional properties of membrane proteins.
△ Less
Submitted 12 July, 2019;
originally announced July 2019.
-
Refractive index sensing with temperature compensation by a multimode-interference fiber-based optical frequency comb sensing cavity
Authors:
Ryo Oe,
Takeo Minamikawa,
Shuji Taue,
Hidenori Koresawa,
Takahiko Mizuno,
Masatomo Yamagiwa,
Yasuhiro Mizutani,
Hirotsugu Yamamoto,
Tetsuo Iwata,
Takeshi Yasui
Abstract:
We proposed a refractive index (RI) sensing method with temperature compensation by using an optical frequency comb (OFC) sensing cavity employing a multimode-interference (MMI) fiber, namely, the MMI-OFC sensing cavity. The MMI-OFC sensing cavity enables simultaneous measurement of material-dependent RI and sample temperature by decoding from the comb spacing frequency shift and the wavelength sh…
▽ More
We proposed a refractive index (RI) sensing method with temperature compensation by using an optical frequency comb (OFC) sensing cavity employing a multimode-interference (MMI) fiber, namely, the MMI-OFC sensing cavity. The MMI-OFC sensing cavity enables simultaneous measurement of material-dependent RI and sample temperature by decoding from the comb spacing frequency shift and the wavelength shift of the OFC. We realized the simultaneous and continuous measurement of RI-related concentration of a liquid sample and its temperature with precisions of 1.6*10^-4 RIU and 0.08 degree. The proposed method would be a useful means for the various applications based on RI sensing.
△ Less
Submitted 13 May, 2019;
originally announced May 2019.
-
Dependence of the transportation time on the sequence in which particles with different hop** probabilities enter a lattice
Authors:
Hiroki Yamamoto,
Daichi Yanagisawa,
Katsuhiro Nishinari
Abstract:
Smooth transportation has drawn the attention of many researchers and practitioners in several fields. In the present paper, we propose a modified model of a totally asymmetric simple exclusion process (TASEP), which includes multiple species of particles and takes into account the sequence in which the particles enter a lattice. We investigate the dependence of the transportation time on this `en…
▽ More
Smooth transportation has drawn the attention of many researchers and practitioners in several fields. In the present paper, we propose a modified model of a totally asymmetric simple exclusion process (TASEP), which includes multiple species of particles and takes into account the sequence in which the particles enter a lattice. We investigate the dependence of the transportation time on this `entering sequence' and show that for a given collection of particles group sequence in some cases minimizes the transportation time better than a random sequence. We also introduce the `sorting cost' necessary to transform a random sequence into a group sequence and show that when this is included a random sequence can become advantageous in some conditions. We obtain these results not only from numerical simulations but also by theoretical analyses that generalize the simulation results for some special cases.
△ Less
Submitted 18 September, 2019; v1 submitted 10 April, 2019;
originally announced April 2019.
-
Lock-in-detection dual-comb spectroscopy
Authors:
Hidenori Koresawa,
Kyuki Shibuya,
Takeo Minamikawa,
Akifumi Asahara,
Ryo Oe,
Takahiko Mizuno,
Masatomo Yamagiwa,
Yasuhiro Mizutani,
Tetsuo Iwata,
Hirotsugu Yamamoto,
Kaoru Minoshima,
Takeshi Yasui
Abstract:
Dual-comb spectroscopy (DCS) is useful for gas spectroscopy due to high potential of optical frequency comb (OFC). However, fast Fourier transform (FFT) calculation of a huge amount of temporal data spends significantly longer time than the acquisition time of an interferogram. In this article, we demonstrate frequency-domain DCS by a combination of DCS with lock-in detection, namely LID-DCS. LID-…
▽ More
Dual-comb spectroscopy (DCS) is useful for gas spectroscopy due to high potential of optical frequency comb (OFC). However, fast Fourier transform (FFT) calculation of a huge amount of temporal data spends significantly longer time than the acquisition time of an interferogram. In this article, we demonstrate frequency-domain DCS by a combination of DCS with lock-in detection, namely LID-DCS. LID-DCS directly extracts an arbitrary OFC mode from a vast number of OFC modes without the need for FFT calculation. Usefulness of LID-DCS is demonstrated in rapid monitoring of transient signal change and spectroscopy of hydrogen cyanide gas.
△ Less
Submitted 6 April, 2019;
originally announced April 2019.
-
Body-rotation behavior of pedestrians for collision avoidance in passing and cross flow
Authors:
Hiroki Yamamoto,
Daichi Yanagisawa,
Claudio Feliciani,
Katsuhiro Nishinari
Abstract:
We observe body-rotation behavior of pedestrians to avoid others when they are moving in congested situations. In such cases, body orientation often differs from walking direction, i.e., pedestrians step sideways.
In this paper, we focused on a deviation between body orientation and walking direction during collision avoidance by body rotation for counter-flows in narrow corridors quantitatively…
▽ More
We observe body-rotation behavior of pedestrians to avoid others when they are moving in congested situations. In such cases, body orientation often differs from walking direction, i.e., pedestrians step sideways.
In this paper, we focused on a deviation between body orientation and walking direction during collision avoidance by body rotation for counter-flows in narrow corridors quantitatively. We conducted simple experiments in which two pedestrians passed each other. We found that pedestrians rotated their bodies when the width of the corridor was smaller than the sum of the widths of the two pedestrians. This behavior was explained by analyzing the geometry of two ellipses circumscribing each other in a narrow corridor. Moreover, we developed a preliminary model and succeeded to simulate the deviation between body orientation and walking direction during passing observed in the experiments.
Furthermore, we performed a cross-flow experiment, which is much more complex and realistic than the passing experiments and confirmed that body-rotation behavior is also an indispensable factor for complex and realistic scenarios.
△ Less
Submitted 4 April, 2019; v1 submitted 18 March, 2019;
originally announced March 2019.
-
The International Linear Collider: A Global Project
Authors:
Philip Bambade,
Tim Barklow,
Ties Behnke,
Mikael Berggren,
James Brau,
Philip Burrows,
Dmitri Denisov,
Angeles Faus-Golfe,
Brian Foster,
Keisuke Fujii,
Juan Fuster,
Frank Gaede,
Paul Grannis,
Christophe Grojean,
Andrew Hutton,
Benno List,
Jenny List,
Shinichiro Michizono,
Akiya Miyamoto,
Olivier Napoly,
Michael Peskin,
Roman Poeschl,
Frank Simon,
Jan Strube,
Jun** Tian
, et al. (7 additional authors not shown)
Abstract:
The International Linear Collider (ILC) is now under consideration as the next global project in particle physics. In this report, we review of all aspects of the ILC program: the physics motivation, the accelerator design, the run plan, the proposed detectors, the experimental measurements on the Higgs boson, the top quark, the couplings of the W and Z bosons, and searches for new particles. We r…
▽ More
The International Linear Collider (ILC) is now under consideration as the next global project in particle physics. In this report, we review of all aspects of the ILC program: the physics motivation, the accelerator design, the run plan, the proposed detectors, the experimental measurements on the Higgs boson, the top quark, the couplings of the W and Z bosons, and searches for new particles. We review the important role that polarized beams play in the ILC program. The first stage of the ILC is planned to be a Higgs factory at 250 GeV in the centre of mass. Energy upgrades can naturally be implemented based on the concept of a linear collider. We discuss in detail the ILC program of Higgs boson measurements and the expected precision in the determination of Higgs couplings. We compare the ILC capabilities to those of the HL-LHC and to those of other proposed e+e- Higgs factories. We emphasize throughout that the readiness of the accelerator and the estimates of ILC performance are based on detailed simulations backed by extensive RandD and, for the accelerator technology, operational experience.
△ Less
Submitted 5 April, 2019; v1 submitted 4 March, 2019;
originally announced March 2019.
-
The International Linear Collider. A Global Project
Authors:
Hiroaki Aihara,
Jonathan Bagger,
Philip Bambade,
Barry Barish,
Ties Behnke,
Alain Bellerive,
Mikael Berggren,
James Brau,
Martin Breidenbach,
Ivanka Bozovic-Jelisavcic,
Philip Burrows,
Massimo Caccia,
Paul Colas,
Dmitri Denisov,
Gerald Eigen,
Lyn Evans,
Angeles Faus-Golfe,
Brian Foster,
Keisuke Fujii,
Juan Fuster,
Frank Gaede,
Jie Gao,
Paul Grannis,
Christophe Grojean,
Andrew Hutton
, et al. (37 additional authors not shown)
Abstract:
A large, world-wide community of physicists is working to realise an exceptional physics program of energy-frontier, electron-positron collisions with the International Linear Collider (ILC). This program will begin with a central focus on high-precision and model-independent measurements of the Higgs boson couplings. This method of searching for new physics beyond the Standard Model is orthogonal…
▽ More
A large, world-wide community of physicists is working to realise an exceptional physics program of energy-frontier, electron-positron collisions with the International Linear Collider (ILC). This program will begin with a central focus on high-precision and model-independent measurements of the Higgs boson couplings. This method of searching for new physics beyond the Standard Model is orthogonal to and complements the LHC physics program. The ILC at 250 GeV will also search for direct new physics in exotic Higgs decays and in pair-production of weakly interacting particles. Polarised electron and positron beams add unique opportunities to the physics reach. The ILC can be upgraded to higher energy, enabling precision studies of the top quark and measurement of the top Yukawa coupling and the Higgs self-coupling. The key accelerator technology, superconducting radio-frequency cavities, has matured. Optimised collider and detector designs, and associated physics analyses, were presented in the ILC Technical Design Report, signed by 2400 scientists. There is a strong interest in Japan to host this international effort. A detailed review of the many aspects of the project is nearing a conclusion in Japan. Now the Japanese government is preparing for a decision on the next phase of international negotiations, that could lead to a project start within a few years. The potential timeline of the ILC project includes an initial phase of about 4 years to obtain international agreements, complete engineering design and prepare construction, and form the requisite international collaboration, followed by a construction phase of 9 years.
△ Less
Submitted 28 January, 2019;
originally announced January 2019.
-
Performance and Moli`ere radius measurements using a compact prototype of LumiCal in an electron test beam
Authors:
H. Abramowicz,
A. Abusleme,
K. Afanaciev,
Y. Benhammou,
O. Borysov,
M. Borysova,
I. Bozovic- Jelisavcic,
W. Daniluk,
D. Dannheim,
M. Demichev,
K. Elsener,
M. Firlej,
E. Firu,
T. Fiutowski,
V. Ghenescu,
M. Gostkin,
M. Hempelb,
H. Henschel,
M. Idzik,
A. Ignatenkoc,
A. Ishikawa,
A. Joffe,
G. Kacarevic,
S. Kananov,
O. Karachebanb
, et al. (29 additional authors not shown)
Abstract:
A new design of a detector plane of sub-millimetre thickness for an electromagnetic sampling calorimeter is presented. It is intended to be used in the luminometers LumiCal and BeamCal in future linear $e^+e^-$ collider experiments. The detector planes were produced utilising novel connectivity scheme technologies. They were installed in a compact prototype of the calorimeter and tested at DESY wi…
▽ More
A new design of a detector plane of sub-millimetre thickness for an electromagnetic sampling calorimeter is presented. It is intended to be used in the luminometers LumiCal and BeamCal in future linear $e^+e^-$ collider experiments. The detector planes were produced utilising novel connectivity scheme technologies. They were installed in a compact prototype of the calorimeter and tested at DESY with an electron beam of energy 1-5 GeV. The performance of a prototype of a compact LumiCal comprising eight detector planes was studied. The effective Moli`ere radius at 5 GeV was determined to be (8.1 +/- 0.1 (stat) +/- 0.3 (syst)) mm, a value well reproduced by the Monte Carlo (MC) simulation (8.4 +/- 0.1) mm. The dependence of the effective Moli`ere radius on the electron energy in the range 1-5 GeV was also studied. Good agreement was obtained between data and MC simulation.
△ Less
Submitted 25 October, 2019; v1 submitted 29 December, 2018;
originally announced December 2018.
-
Multicascade-linked synthetic wavelength digital holography using an optical-comb-referenced frequency synthesizer
Authors:
Masatomo Yamagiwa,
Takeo Minamikawa,
Clément Trovato,
Takayuki Ogawa,
Dahi Ghareab Abdelsalam Ibrahim,
Yusuke Kawahito,
Ryo Oe,
Kyuki Shibuya,
Takahiko Mizuno,
Emmanuel Abraham,
Yasuhiro Mizutani,
Tetsuo Iwata Hirotsugu Yamamoto,
Kaoru Minoshima,
Takeshi Yasui
Abstract:
Digital holography (DH) is a promising method for non-contact surface topography because the reconstructed phase image can visualize the nanometer unevenness in a sample. However, the axial range of this method is limited to the range of the optical wavelength due to the phase wrap** ambiguity. Although the use of two different wavelengths of light and the resulting synthetic wavelength, i.e., s…
▽ More
Digital holography (DH) is a promising method for non-contact surface topography because the reconstructed phase image can visualize the nanometer unevenness in a sample. However, the axial range of this method is limited to the range of the optical wavelength due to the phase wrap** ambiguity. Although the use of two different wavelengths of light and the resulting synthetic wavelength, i.e., synthetic wavelength DH, can expand the axial range up to a few tens of microns, this method is still insufficient for practical applications. In this article, a tunable external cavity laser diode phase-locked to an optical frequency comb, namely, an optical-comb-referenced frequency synthesizer, is effectively used for multiple synthetic wavelengths within the range of 32 um to 1.20 m. A multiple cascade link of the phase images among an optical wavelength (= 1.520 um) and 5 different synthetic wavelengths (= 32.39 um, 99.98 um, 400.0 um, 1003 um, and 4021 um) enables the shape measurement of a reflective millimeter-sized stepped surface with the axial resolution of 34 nm. The axial dynamic range, defined as the ratio of the maximum axial range (= 0.60 m) to the axial resolution (= 34 nm), achieves 1.7*10^8, which is much larger than that of previous synthetic wavelength DH. Such a wide axial dynamic range capability will further expand the application field of DH for large objects with meter dimensions.
△ Less
Submitted 27 July, 2018;
originally announced August 2018.
-
Refractive-index-sensing radio-frequency comb with intracavity multi-mode interference fibre sensor
Authors:
Roy Oe,
Shuji Taue,
Takeo Minamikawa,
Kosuke Nagai,
Yasuhiro Mizutani,
Tetsuo Iwata,
Hirotsugu Yamamoto,
Hideki Fukano,
Yoshiaki Nakajima,
Kaoru Minoshima,
Takeshi Yasui
Abstract:
Optical frequency combs have attracted attention as optical frequency rulers due to their tooth-like discrete spectra together with their inherent mode-locking nature and phase-locking control to a frequency standard. Based on this concept, their applications until now have been demonstrated in the fields of optical frequency metrology and optical distance metrology. However, if the utility of opt…
▽ More
Optical frequency combs have attracted attention as optical frequency rulers due to their tooth-like discrete spectra together with their inherent mode-locking nature and phase-locking control to a frequency standard. Based on this concept, their applications until now have been demonstrated in the fields of optical frequency metrology and optical distance metrology. However, if the utility of optical combs can be further expanded beyond their optical-frequency-ruler-based application by exploiting new aspects of optical combs, this will lead to new developments in optical metrology and instrumentation. Here, we report a fibre sensing application of optical combs based on a coherent frequency link between the optical and radio-frequency regions, enabling high-precision refractive index measurement of a liquid sample based on frequency measurement in radio-frequency region. Our technique encodes a refractive index change of a liquid sample into a radio-frequency comb by a combination of an intracavity multi-mode-interference fibre sensor and wavelength dispersion of a cavity fibre. Then, the change in refractive index is read out by measuring the repetition frequency of the radio-frequency comb with a frequency counter and a frequency standard. Use of an optical comb as a photonic radio-frequency converter will lead to the development of new applications in high-precision fibre sensing with the help of functional fibre sensors and precise radio-frequency measurement.
△ Less
Submitted 12 February, 2018;
originally announced February 2018.
-
On fundamental diffraction limitation of finesse of a Fabry-Perot cavity
Authors:
Mikhail V. Poplavskiy,
Andrey B. Matsko,
Hiroaki Yamamoto,
Sergey P. Vyatchanin
Abstract:
We perform a theoretical study of finesse limitations of a Fabry-Perot (FP) cavity occurring due to finite size, asymmetry, as well as imperfections of the cavity mirrors. A method of numerical simulations of the eigenvalue problem applicable for both the fundamental and high order cavity modes is suggested. Using this technique we find spatial profile of the modes and their round-trip diffraction…
▽ More
We perform a theoretical study of finesse limitations of a Fabry-Perot (FP) cavity occurring due to finite size, asymmetry, as well as imperfections of the cavity mirrors. A method of numerical simulations of the eigenvalue problem applicable for both the fundamental and high order cavity modes is suggested. Using this technique we find spatial profile of the modes and their round-trip diffraction loss. The results of the numerical simulations and analytical calculations are nearly identical when we consider a conventional FP cavity. The proposed numerical technique has much broader applicability range and is valid for any FP cavity with arbitrary non-spherical mirrors which have cylindrical symmetry but disturbed in an asymmetric way, for example, by tilt or roughness of their mirrors.
△ Less
Submitted 21 December, 2017;
originally announced December 2017.
-
Dual-optical-comb spectroscopic ellipsometry
Authors:
Takeo Minamikawa,
Yi-Da Hsieh,
Kyuki Shibuya,
Eiji Hase,
Yoshiki Kaneoka,
Sho Okubo,
Hajime Inaba,
Yasuhiro Mizutani,
Hirotsugu Yamamoto,
Tetsuo Iwata,
Takeshi Yasui
Abstract:
Spectroscopic ellipsometry is a means to investigate optical and dielectric material responses. Conventional spectroscopic ellipsometry has trade-offs between spectral accuracy, resolution, and measurement time. Polarization modulation has afforded poor performance due to its sensitivity to mechanical vibrational noise, thermal instability, and polarization wavelength dependency. We equip a spectr…
▽ More
Spectroscopic ellipsometry is a means to investigate optical and dielectric material responses. Conventional spectroscopic ellipsometry has trade-offs between spectral accuracy, resolution, and measurement time. Polarization modulation has afforded poor performance due to its sensitivity to mechanical vibrational noise, thermal instability, and polarization wavelength dependency. We equip a spectroscopic ellipsometer with dual-optical-comb spectroscopy, viz. dual-optical-comb spectroscopic ellipsometry (DCSE). The DCSE directly and simultaneously obtains amplitude and phase information with ultra-high spectral precision that is beyond the conventional limit. This precision is due to the automatic time-swee** acquisition of the interferogram using Fourier transform spectroscopy and optical combs with well-defined frequency. Ellipsometric evaluation without polarization modulation also enhances the stability and robustness of the system. In this study, we evaluate the DCSE of birefringent materials and thin films, which showed improved spectral accuracy and a resolution of up to 1.2x10-5 nm across a 5-10 THz spectral bandwidth without any mechanical movement.
△ Less
Submitted 30 May, 2017;
originally announced June 2017.
-
Scan-less confocal phase microscopy based on dual comb spectroscopy of two-dimensional-image-encoding optical frequency comb
Authors:
Eiji Hase,
Takeo Minamikawa,
Shuji Miyamoto,
Ryuji Ichikawa,
Yi-Da Hsieh,
Kyuki Shibuya,
Yoshiaki Nakajima,
Akifumi Asahara,
Kaoru Minoshima,
Yasuhiro Mizutani,
Tetsuo Iwata,
Hirotsugu Yamamoto,
Takeshi Yasui
Abstract:
Confocal imaging and phase imaging are powerful tools in life science research and industrial inspection. To coherently link the two techniques with different depth resolutions, we introduce an optical frequency comb (OFC) to microscopy. Two-dimensional (2D) image pixels of a sample were encoded onto OFC modes via 2D spectral encoding, in which OFC acted as an optical carrier with a vast number of…
▽ More
Confocal imaging and phase imaging are powerful tools in life science research and industrial inspection. To coherently link the two techniques with different depth resolutions, we introduce an optical frequency comb (OFC) to microscopy. Two-dimensional (2D) image pixels of a sample were encoded onto OFC modes via 2D spectral encoding, in which OFC acted as an optical carrier with a vast number of discrete frequency channels. Then, a scan-less full-field confocal image with a depth resolution of 62.4 um was decoded from a mode-resolved OFC amplitude spectrum obtained by dual-comb spectroscopy. Furthermore, a phase image with a depth resolution of 13.7 nm was decoded from a mode-resolved OFC phase spectrum under the above confocality. The phase wrap** ambiguity can be removed by the match between the confocal depth resolution and the phase wrap** period. The proposed hybrid microscopy approach will be a powerful tool for a variety of applications.
△ Less
Submitted 19 May, 2017;
originally announced May 2017.
-
Measurement of shower development and its Molière radius with a four-plane LumiCal test set-up
Authors:
H. Abramowicz,
A. Abusleme,
K. Afanaciev,
Y. Benhammou,
L. Bortko,
O. Borysov,
M. Borysova,
I. Bozovic-Jelisavcic,
G. Chelkov,
W. Daniluk,
D. Dannheim,
K. Elsener,
M. Firlej,
E. Firu,
T. Fiutowski,
V. Ghenescu,
M. Gostkin,
M. Hempel,
H. Henschel,
M. Idzik,
A. Ignatenko,
A. Ishikawa,
S. Kananov,
O. Karacheban,
W. Klempt
, et al. (35 additional authors not shown)
Abstract:
A prototype of a luminometer, designed for a future e+e- collider detector, and consisting at present of a four-plane module, was tested in the CERN PS accelerator T9 beam. The objective of this beam test was to demonstrate a multi-plane tungsten/silicon operation, to study the development of the electromagnetic shower and to compare it with MC simulations. The Molière radius has been determined t…
▽ More
A prototype of a luminometer, designed for a future e+e- collider detector, and consisting at present of a four-plane module, was tested in the CERN PS accelerator T9 beam. The objective of this beam test was to demonstrate a multi-plane tungsten/silicon operation, to study the development of the electromagnetic shower and to compare it with MC simulations. The Molière radius has been determined to be 24.0 +/- 0.6 (stat.) +/- 1.5 (syst.) mm using a parametrization of the shower shape. Very good agreement was found between data and a detailed Geant4 simulation.
△ Less
Submitted 12 March, 2018; v1 submitted 10 May, 2017;
originally announced May 2017.
-
Scan-less hyperspectral dual-comb single-pixel-imaging in both amplitude and phase
Authors:
Kyuki Shibuya,
Takeo Minamikawa,
Yasuhiro Mizutani,
Hirotsugu Yamamoto,
Kaoru Minoshima,
Takeshi Yasui,
Tetsuo Iwata
Abstract:
We have developed a hyperspectral imaging scheme that involves a combination of dual-comb spectroscopy and Hadamard-transform-based single-pixel imaging. The scheme enables us to obtain 12,000 hyperspectral images of amplitude and phase at a spatial resolution of 46 um without mechanical scanning. The spectral resolution is 20 MHz, as determined by the linewidth of a single comb mode, and the spec…
▽ More
We have developed a hyperspectral imaging scheme that involves a combination of dual-comb spectroscopy and Hadamard-transform-based single-pixel imaging. The scheme enables us to obtain 12,000 hyperspectral images of amplitude and phase at a spatial resolution of 46 um without mechanical scanning. The spectral resolution is 20 MHz, as determined by the linewidth of a single comb mode, and the spectral interval is 100 MHz over a spectral range of 1.2 THz centred at 191.5 THz. As an initial demonstration of our scheme, we obtained spectroscopic images of a standard test chart through an etalon plate. The thickness of an absorptive chromium-coated layer on a float-glass substrate was determined to be 70 nm from the hyperspectral phase images in the near-infrared wavelength region.
△ Less
Submitted 5 May, 2017;
originally announced May 2017.
-
Thermal distortions of non-Gaussian beams in Fabry-Perot cavities
Authors:
J Miller,
P Willems,
H Yamamoto,
J Agresti,
R DeSalvo
Abstract:
Thermal effects are already important in currently operating interferometric gravitational wave detectors. Planned upgrades of these detectors involve increasing optical power to combat quantum shot noise. We consider the ramifications of this increased power for one particular class of laser beams--wide, flat-topped, mesa beams. In particular we model a single mesa beam Fabry-Perot cavity having…
▽ More
Thermal effects are already important in currently operating interferometric gravitational wave detectors. Planned upgrades of these detectors involve increasing optical power to combat quantum shot noise. We consider the ramifications of this increased power for one particular class of laser beams--wide, flat-topped, mesa beams. In particular we model a single mesa beam Fabry-Perot cavity having thermoelastically deformed mirrors. We calculate the intensity profile of the fundamental cavity eigenmode in the presence of thermal perturbations, and the associated changes in thermal noise. We also outline an idealized method of correcting for such effects. At each stage we contrast our results with those of a comparable Gaussian beam cavity. Although we focus on mesa beams the techniques described are applicable to any azimuthally symmetric system.
△ Less
Submitted 11 April, 2017;
originally announced April 2017.
-
Photoresponse of La$_{1.85}$Sr$_{0.15}$CuO$_{4}$ nanostrip
Authors:
H. Shibata,
N. Kirigane,
K. Fukao,
D. Sakai,
S. Karimoto,
H. Yamamoto
Abstract:
We report the fabrication and photoresponse of 5 nm thick La$_{1.85}$Sr$_{0.15}$CuO$_{4}$ nanostrip with a width of 100nm. The I-V characteristics of the nanostrip show a hysteresis and a sharp voltage jump at $I_{c}$. The $J_{c}$(3K) of the nanostrip is 2.3 x 10$^{7}$ A/cm$^{2}$. The nanostrip exhibits photoresponse signals when illuminated by a pulse laser at 1560 nm wavelength with a bias curre…
▽ More
We report the fabrication and photoresponse of 5 nm thick La$_{1.85}$Sr$_{0.15}$CuO$_{4}$ nanostrip with a width of 100nm. The I-V characteristics of the nanostrip show a hysteresis and a sharp voltage jump at $I_{c}$. The $J_{c}$(3K) of the nanostrip is 2.3 x 10$^{7}$ A/cm$^{2}$. The nanostrip exhibits photoresponse signals when illuminated by a pulse laser at 1560 nm wavelength with a bias current just below $I_{c}$. The height of the signal reduces as the optical intensity decreases and disappears below -10 dBm. The signal also decreases as the temperature increases, but it exists up to 30 K. These results suggest the possibility of La$_{1.85}$Sr$_{0.15}$CuO$_{4}$ nanostrip as single-photon detector (SSPD, SNSPD) working at high temperature by further reducing the cross-section of the strip.
△ Less
Submitted 30 March, 2017;
originally announced March 2017.
-
Radiation tolerance of FPCCD vertex detector for the ILC
Authors:
Shunsuke Murai,
Akimasa Ishikawa,
Tomoyuki Sanuki,
Akiya Miyamoto,
Yasuhiro Sugimoto,
Hisao Sato,
Hirokazu Ikeda,
Hitoshi Yamamoto
Abstract:
The Fine Pixel CCD (FPCCD) is one of the candidate sensor technologies for the ILC vertex detector. The vertex detector is located near the interaction point, thus high radiation tolerance is required. Charge transfer efficiency of CCD is degraded by radiation damage which makes traps in pixels. We measured charge transfer inefficiency (CTI) of a neutron irradiated FPCCD prototype. We observed a d…
▽ More
The Fine Pixel CCD (FPCCD) is one of the candidate sensor technologies for the ILC vertex detector. The vertex detector is located near the interaction point, thus high radiation tolerance is required. Charge transfer efficiency of CCD is degraded by radiation damage which makes traps in pixels. We measured charge transfer inefficiency (CTI) of a neutron irradiated FPCCD prototype. We observed a degradation of CTI compared with non-irradiated CCD. To improve the CTI of irradiated CCD, we performed the fat-zero charge injection to fill the traps. In this paper, we report a status of CTI improvement.
△ Less
Submitted 16 March, 2017;
originally announced March 2017.
-
A norm knockout method on indirect reciprocity to reveal indispensable norms
Authors:
Hitoshi Yamamoto,
Isamu Okada,
Satoshi Uchida,
Tatsuya Sasaki
Abstract:
Although various norms for reciprocity-based cooperation have been suggested that are evolutionarily stable against invasion from free riders, the process of alternation of norms and the role of diversified norms remain unclear in the evolution of cooperation. We clarify the co-evolutionary dynamics of norms and cooperation in indirect reciprocity and also identify the indispensable norms for the…
▽ More
Although various norms for reciprocity-based cooperation have been suggested that are evolutionarily stable against invasion from free riders, the process of alternation of norms and the role of diversified norms remain unclear in the evolution of cooperation. We clarify the co-evolutionary dynamics of norms and cooperation in indirect reciprocity and also identify the indispensable norms for the evolution of cooperation. Inspired by the gene knockout method, a genetic engineering technique, we developed the norm knockout method and clarified the norms necessary for the establishment of cooperation. The results of numerical investigations revealed that the majority of norms gradually transitioned to tolerant norms after defectors are eliminated by strict norms. Furthermore, no cooperation emerges when specific norms that are intolerant to defectors are knocked out.
△ Less
Submitted 11 March, 2017;
originally announced March 2017.
-
Quantum correlation measurements in interferometric gravitational wave detectors
Authors:
D. V. Martynov,
V. V. Frolov,
S. Kandhasamy,
K. Izumi,
H. Miao,
N. Mavalvala,
E. D. Hall,
R. Lanza,
B. P. Abbott,
R. Abbott,
T. D. Abbott,
C. Adams,
R. X. Adhikari,
S. B. Anderson,
A. Ananyeva,
S. Appert,
K. Arai,
S. M. Aston,
S. W. Ballmer,
D. Barker,
B. Barr,
L. Barsotti,
J. Bartlett,
I. Bartos,
J. C. Batch
, et al. (177 additional authors not shown)
Abstract:
Quantum fluctuations in the phase and amplitude quadratures of light set limitations on the sensitivity of modern optical instruments. The sensitivity of the interferometric gravitational wave detectors, such as the Advanced Laser Interferometer Gravitational wave Observatory (LIGO), is limited by quantum shot noise, quantum radiation pressure noise, and a set of classical noises. We show how the…
▽ More
Quantum fluctuations in the phase and amplitude quadratures of light set limitations on the sensitivity of modern optical instruments. The sensitivity of the interferometric gravitational wave detectors, such as the Advanced Laser Interferometer Gravitational wave Observatory (LIGO), is limited by quantum shot noise, quantum radiation pressure noise, and a set of classical noises. We show how the quantum properties of light can be used to distinguish these noises using correlation techniques. Particularly, in the first part of the paper we show estimations of the coating thermal noise and gas phase noise, hidden below the quantum shot noise in the Advanced LIGO sensitivity curve. We also make projections on the observatory sensitivity during the next science runs. In the second part of the paper we discuss the correlation technique that reveals the quantum radiation pressure noise from the background of classical noises and shot noise. We apply this technique to the Advanced LIGO data, collected during the first science run, and experimentally estimate the quantum correlations and quantum radiation pressure noise in the interferometer for the first time.
△ Less
Submitted 10 February, 2017;
originally announced February 2017.
-
The Evolution of Reputation-Based Cooperation in Regular Networks
Authors:
Tatsuya Sasaki,
Hitoshi Yamamoto,
Isamu Okada,
Satoshi Uchida
Abstract:
Despite recent advances in reputation technologies, it is not clear how reputation systems can affect human cooperation in social networks. Although it is known that two of the major mechanisms in the evolution of cooperation are spatial selection and reputation-based reciprocity, theoretical study of the interplay between both mechanisms remains almost uncharted. Here, we present a new individual…
▽ More
Despite recent advances in reputation technologies, it is not clear how reputation systems can affect human cooperation in social networks. Although it is known that two of the major mechanisms in the evolution of cooperation are spatial selection and reputation-based reciprocity, theoretical study of the interplay between both mechanisms remains almost uncharted. Here, we present a new individual-based model for the evolution of reciprocal cooperation between reputation and networks. We comparatively analyze four of the leading moral assessment rules---shunning, image scoring, stern judging, and simple standing---and base the model on the giving game in regular networks for Cooperators, Defectors, and Discriminators. Discriminators rely on a proper moral assessment rule. By using individual-based models, we show that the four assessment rules are differently characterized in terms of how cooperation evolves, depending on the benefit-to-cost ratio, the network-node degree, and the observation and error conditions. Our findings show that the most tolerant rule---simple standing---is the most robust among the four assessment rules in promoting cooperation in regular networks.
△ Less
Submitted 22 January, 2017;
originally announced January 2017.
-
The Sensitivity of the Advanced LIGO Detectors at the Beginning of Gravitational Wave Astronomy
Authors:
D. V. Martynov,
E. D. Hall,
B. P. Abbott,
R. Abbott,
T. D. Abbott,
C. Adams,
R. X. Adhikari,
R. A. Anderson,
S. B. Anderson,
K. Arai,
M. A. Arain,
S. M. Aston,
L. Austin,
S. W. Ballmer,
M. Barbet,
D. Barker,
B. Barr,
L. Barsotti,
J. Bartlett,
M. A. Barton,
I. Bartos,
J. C. Batch,
A. S. Bell,
I. Belopolski,
J. Bergman
, et al. (239 additional authors not shown)
Abstract:
The Laser Interferometer Gravitational Wave Observatory (LIGO) consists of two widely separated 4 km laser interferometers designed to detect gravitational waves from distant astrophysical sources in the frequency range from 10 Hz to 10 kHz. The first observation run of the Advanced LIGO detectors started in September 2015 and ended in January 2016. A strain sensitivity of better than…
▽ More
The Laser Interferometer Gravitational Wave Observatory (LIGO) consists of two widely separated 4 km laser interferometers designed to detect gravitational waves from distant astrophysical sources in the frequency range from 10 Hz to 10 kHz. The first observation run of the Advanced LIGO detectors started in September 2015 and ended in January 2016. A strain sensitivity of better than $10^{-23}/\sqrt{\text{Hz}}$ was achieved around 100 Hz. Understanding both the fundamental and the technical noise sources was critical for increasing the observable volume in the universe. The average distance at which coalescing binary black hole systems with individual masses of 30 $M_\odot$ could be detected was 1.3 Gpc. Similarly, the range for binary neutron star inspirals was about 75 Mpc. With respect to the initial detectors, the observable volume of Universe increased respectively by a factor 69 and 43. These improvements allowed Advanced LIGO to detect the gravitational wave signal from the binary black hole coalescence, known as GW150914.
△ Less
Submitted 10 February, 2018; v1 submitted 1 April, 2016;
originally announced April 2016.
-
Calibration of the Advanced LIGO detectors for the discovery of the binary black-hole merger GW150914
Authors:
The LIGO Scientific Collaboration,
B. P. Abbott,
R. Abbott,
T. D. Abbott,
M. R. Abernathy,
K. Ackley,
C. Adams,
P. Addesso,
R. X. Adhikari,
V. B. Adya,
C. Affeldt,
N. Aggarwal,
O. D. Aguiar,
A. Ain,
P. Ajith,
B. Allen,
P. A. Altin,
D. V. Amariutei,
S. B. Anderson,
W. G. Anderson,
K. Arai,
M. C. Araya,
C. C. Arceneaux,
J. S. Areeda,
K. G. Arun
, et al. (702 additional authors not shown)
Abstract:
In Advanced LIGO, detection and astrophysical source parameter estimation of the binary black hole merger GW150914 requires a calibrated estimate of the gravitational-wave strain sensed by the detectors. Producing an estimate from each detector's differential arm length control loop readout signals requires applying time domain filters, which are designed from a frequency domain model of the detec…
▽ More
In Advanced LIGO, detection and astrophysical source parameter estimation of the binary black hole merger GW150914 requires a calibrated estimate of the gravitational-wave strain sensed by the detectors. Producing an estimate from each detector's differential arm length control loop readout signals requires applying time domain filters, which are designed from a frequency domain model of the detector's gravitational-wave response. The gravitational-wave response model is determined by the detector's opto-mechanical response and the properties of its feedback control system. The measurements used to validate the model and characterize its uncertainty are derived primarily from a dedicated photon radiation pressure actuator, with cross-checks provided by optical and radio frequency references. We describe how the gravitational-wave readout signal is calibrated into equivalent gravitational-wave-induced strain and how the statistical uncertainties and systematic errors are assessed. Detector data collected over 38 calendar days, from September 12 to October 20, 2015, contain the event GW150914 and approximately 16 of coincident data used to estimate the event false alarm probability. The calibration uncertainty is less than 10% in magnitude and 10 degrees in phase across the relevant frequency band 20 Hz to 1 kHz.
△ Less
Submitted 28 February, 2017; v1 submitted 11 February, 2016;
originally announced February 2016.
-
Optical Gravitational Wave Antenna with Increased Power Handling Capability
Authors:
Andrey B. Matsko,
Mikhail V. Poplavskiy,
Hiroaki Yamamoto,
Sergey P. Vyatchanin
Abstract:
Fundamental sensitivity of an optical interferometric gravitational wave detector increases with increase of the optical power which, in turn, limited because of the opto-mechanical parametric instabilities of the interferometer. We propose to optimize geometrical shape of the mirrors of the detector to reduce the diffraction-limited finesse of unessential optical modes of the interferometer resul…
▽ More
Fundamental sensitivity of an optical interferometric gravitational wave detector increases with increase of the optical power which, in turn, limited because of the opto-mechanical parametric instabilities of the interferometer. We propose to optimize geometrical shape of the mirrors of the detector to reduce the diffraction-limited finesse of unessential optical modes of the interferometer resulting in increase of the threshold of the opto-mechanical instabilities and subsequent increase of the measurement sensitivity. Utilizing parameters of the LIGO interferometer we found that the proposed technique allows constructing a Fabry-Perot interferometer with round trip diffraction loss of the fundamental mode not exceeding $5$~ppm, whereas the loss of the first dipole as well as the other high order modes exceed $1,000$~ppm and $8,000$~ppm, respectively. The optimization comes at the price of tighter tolerances on the mirror tilt stability, but does not result in a significant modification of the optical beam profile and does not require changes in the the gravity detector read-out system. The cavity with proposed mirrors is also stable with respect to the slight modification of the mirror shape.
△ Less
Submitted 18 December, 2015;
originally announced December 2015.
-
Physics Case for the International Linear Collider
Authors:
Keisuke Fujii,
Christophe Grojean,
Michael E. Peskin,
Tim Barklow,
Yuanning Gao,
Shinya Kanemura,
Hyungdo Kim,
Jenny List,
Mihoko Nojiri,
Maxim Perelstein,
Roman Poeschl,
Juergen Reuter,
Frank Simon,
Tomohiko Tanabe,
Jaehoon Yu,
James D. Wells,
Hitoshi Murayama,
Hitoshi Yamamoto
Abstract:
We summarize the physics case for the International Linear Collider (ILC). We review the key motivations for the ILC presented in the literature, updating the projected measurement uncertainties for the ILC experiments in accord with the expected schedule of operation of the accelerator and the results of the most recent simulation studies.
We summarize the physics case for the International Linear Collider (ILC). We review the key motivations for the ILC presented in the literature, updating the projected measurement uncertainties for the ILC experiments in accord with the expected schedule of operation of the accelerator and the results of the most recent simulation studies.
△ Less
Submitted 26 June, 2015; v1 submitted 19 June, 2015;
originally announced June 2015.
-
Observation of Parametric Instability in Advanced LIGO
Authors:
Matthew Evans,
Slawek Gras,
Peter Fritschel,
John Miller,
Lisa Barsotti,
Denis Martynov,
Aidan Brooks,
Dennis Coyne,
Rich Abbott,
Rana Adhikari,
Koji Arai,
Rolf Bork,
Bill Kells,
Jameson Rollins,
Nicolas Smith-Lefebvre,
Gabriele Vajente,
Hiroaki Yamamoto,
Ryan Derosa,
Anamaria Effler,
Keiko Kokeyama,
Joseph Betzweiser,
Valera Frolov,
Adam Mullavey,
Sheila Dwyer,
Kiwamu Izumi
, et al. (19 additional authors not shown)
Abstract:
Parametric instabilities have long been studied as a potentially limiting effect in high-power interferometric gravitational wave detectors. Until now, however, these instabilities have never been observed in a kilometer-scale interferometer. In this work we describe the first observation of parametric instability in an Advanced LIGO detector, and the means by which it has been removed as a barrie…
▽ More
Parametric instabilities have long been studied as a potentially limiting effect in high-power interferometric gravitational wave detectors. Until now, however, these instabilities have never been observed in a kilometer-scale interferometer. In this work we describe the first observation of parametric instability in an Advanced LIGO detector, and the means by which it has been removed as a barrier to progress.
△ Less
Submitted 27 February, 2015; v1 submitted 20 February, 2015;
originally announced February 2015.
-
In-situ characterization of the thermal state of resonant optical interferometers via tracking of their higher-order mode resonances
Authors:
Chris L. Mueller,
Paul Fulda,
Rana X. Adhikari,
Koji Arai,
Aidan F. Brooks,
Rijuparna Chakraborty,
Valery V. Frolov,
Peter Fritschel,
Eleanor J. King,
David B. Tanner,
Hiroaki Yamamoto,
Guido Mueller
Abstract:
Thermal lensing in resonant optical interferometers such as those used for gravitational wave detection is a concern due to the negative impact on control signals and instrument sensitivity. In this paper we describe a method for monitoring the thermal state of such interferometers by probing the higher-order spatial mode resonances of the cavities within them. We demonstrate the use of this techn…
▽ More
Thermal lensing in resonant optical interferometers such as those used for gravitational wave detection is a concern due to the negative impact on control signals and instrument sensitivity. In this paper we describe a method for monitoring the thermal state of such interferometers by probing the higher-order spatial mode resonances of the cavities within them. We demonstrate the use of this technique to measure changes in the Advanced LIGO input mode cleaner cavity geometry as a function of input power, and subsequently infer the optical absorption at the mirror surfaces at the level of 1 ppm per mirror. We also demonstrate the generation of a useful error signal for thermal state of the Advanced LIGO power recycling cavity by continuously tracking the first order spatial mode resonance frequency. Such an error signal could be used as an input to thermal compensation systems to maintain the interferometer cavity geometries in the presence of transients in circulating light power levels, thereby maintaining optimal sensitivity and maximizing the duty-cycle of the detectors.
△ Less
Submitted 8 February, 2015;
originally announced February 2015.
-
Real-time absolute frequency measurement of continuous-wave terahertz wave based on dual terahertz combs of photocarriers with different frequency spacings
Authors:
Takeshi Yasui,
Kenta Hayashi,
Ryuji Ichikawa,
Harsono Cahyadi,
Yi-Da Hsieh,
Yasuhiro Mizutani,
Hirotsugu Yamamoto,
Tetsuo Iwata,
Hajime Inaba,
Kaoru Minoshima
Abstract:
Real-time measurement of the absolute frequency of continuous-wave terahertz (CW-THz) waves is required for characterization and frequency calibration of practical CW-THz sources. We proposed a method for real-time monitoring of the absolute frequency of CW-THz waves involving temporally parallel, i.e., simultaneous, measurement of two pairs of beat frequencies and laser repetition frequencies bas…
▽ More
Real-time measurement of the absolute frequency of continuous-wave terahertz (CW-THz) waves is required for characterization and frequency calibration of practical CW-THz sources. We proposed a method for real-time monitoring of the absolute frequency of CW-THz waves involving temporally parallel, i.e., simultaneous, measurement of two pairs of beat frequencies and laser repetition frequencies based on dual THz combs of photocarriers (PC-THz combs) with different frequency spacings. To demonstrate the method, THz-comb-referenced spectrum analyzers were constructed with a dual configuration based on dual femtosecond lasers. Regardless of the presence or absence of frequency control in the PC-THz combs, a frequency precision of 10-11 was achieved at a measurement rate of 100 Hz. Furthermore, large fluctuation of the CW-THz frequencies, crossing several modes of the PC-THz combs, was correctly monitored in real time. The proposed method will be a powerful tool for the research and development of practical CW-THz sources, and other applications.
△ Less
Submitted 25 January, 2015;
originally announced January 2015.
-
Parametric Instability in Long Optical Cavities and Suppression by Dynamic Transverse Mode Frequency Modulation
Authors:
Chunnong Zhao,
Li Ju,
Qi Fang,
Carl Blair,
Jiayi Qin,
David Blair,
Jerome Degallaix,
Hiroaki Yamamoto
Abstract:
Three mode parametric instability has been predicted in Advanced gravitational wave detectors. Here we present the first observation of this phenomenon in a large scale suspended optical cavity designed to be comparable to those of advanced gravitational wave detectors. Our results show that previous modelling assumptions that transverse optical modes are stable in frequency except for frequency d…
▽ More
Three mode parametric instability has been predicted in Advanced gravitational wave detectors. Here we present the first observation of this phenomenon in a large scale suspended optical cavity designed to be comparable to those of advanced gravitational wave detectors. Our results show that previous modelling assumptions that transverse optical modes are stable in frequency except for frequency drifts on a thermal deformation time scale is unlikely to be valid for suspended mass optical cavities. We demonstrate that mirror figure errors cause a dependence of transverse mode offset frequency on spot position. Combined with low frequency residual motion of suspended mirrors, this leads to transverse mode frequency modulation which suppresses the effective parametric gain. We show that this gain suppression mechanism can be enhanced by laser spot dithering or fast thermal modulation. Using Advanced LIGO test mass data and thermal modelling we show that gain suppression factors of 10-20 could be achieved for individual modes, sufficient to greatly ameliorate the parametric instability problem.
△ Less
Submitted 13 January, 2015; v1 submitted 7 January, 2015;
originally announced January 2015.