High-resolution Compton spectroscopy using X-ray microcalorimeters
Authors:
U. Patel,
T. Guruswamy,
A. J. Krzysko,
H. Charalambous,
L. Gades,
K. Wiaderek,
O. Quaranta,
Y. Ren,
A. Yakovenko,
A. Miceli
Abstract:
X-ray Compton spectroscopy is one of the few direct probes of the electron momentum distribution of bulk materials in ambient and operando environments. We report high-resolution inelastic X-ray scattering experiments with high momentum and energy transfer performed at a storage-ring-based high-energy X-ray light source facility using an X-ray microcalorimeter detector. Compton profiles were measu…
▽ More
X-ray Compton spectroscopy is one of the few direct probes of the electron momentum distribution of bulk materials in ambient and operando environments. We report high-resolution inelastic X-ray scattering experiments with high momentum and energy transfer performed at a storage-ring-based high-energy X-ray light source facility using an X-ray microcalorimeter detector. Compton profiles were measured for lithium and cobalt oxide powders relevant to lithium-ion battery research. Spectroscopic analysis of the measured Compton profiles shows high-sensitivity to the low-Z elements and oxidation states. The lineshape analysis of the measured Compton profiles in comparison with computed Hartree-Fock profiles is limited by the resolution of the energy-resolving semiconductor detector. We have characterized an X-ray transition-edge sensor microcalorimeter detector for high-resolution Compton scattering experiments using a bending magnet source at the Advanced Photon Source (APS) with a double crystal monochromator providing monochromatic photon energies near 27.5 keV. The momentum resolution below 0.16 atomic units was measured yielding an improvement of more than a factor of 7 over a state-of-the-art silicon drift detector for the same scattering geometry. Furthermore, the lineshapes of narrow valence and broad core electron profiles of sealed lithium metal were clearly resolved using an X-ray microcalorimeter detector compared to smeared and broadened lineshapes observed when using a silicon drift detector. High-resolution Compton scattering using the energy-resolving detector shown here presents new opportunities for spatial imaging of electron momentum distributions for a wide class of materials with applications ranging from electrochemistry to condensed matter physics.
△ Less
Submitted 1 April, 2022;
originally announced April 2022.
Experimental observations of a new information channal in nature with aim of quartz resonators system
Authors:
Yu. A. Baurov,
V. A. Yakovenko,
A. V. Komissarov,
V. G. Verzhikovski,
A. Yu. Baurov,
A. A. Konradov,
T. A. Zenchenko
Abstract:
The results of long-term (two-year) experimental observations of frequencies of two quartz resonators, one of which is placed in special magnetic system that creates vector potential field, another (calibration one) is placed outside this system, have been presented. Changes with different periodicity: 24 h, high-definite 7 days complex-form period, 27 days and year periods were detected during…
▽ More
The results of long-term (two-year) experimental observations of frequencies of two quartz resonators, one of which is placed in special magnetic system that creates vector potential field, another (calibration one) is placed outside this system, have been presented. Changes with different periodicity: 24 h, high-definite 7 days complex-form period, 27 days and year periods were detected during the observation of differences of these quartz resonators frequencies. The tangents which have been drawn to a terrestrial parallel at the moment of near-daily observation of measured quantity minima form the basic, most powerful subset of directions of tangents having a sharp corner with dipole component of vector potential of the Sun' magnetic field in a range from $50^\circ$ up to $80^\circ$ at annual rotation of laboratory around the Sun together with the Earth. Also there are three subsets of directions similarly drawn tangents fixed in physical space that coincide with similar subsets of tangents directions drawn in the same way to points of radioactive elements $β$-decay count rate minimum under the long $β$-decay research during daily and annual rotation of laboratory together with the Earth. It is necessary to point out that the form of the curves of quartzes frequencies difference changes in scales of the 7-day's period with reliability coincides next year, and observable minima of frequencies in co-phase points of space coincide to within several tens minutes. It is shown that the amplitude of the signal was $5\div10$ times lesser in the period from 20-th, July, till 20-th, January, than from 20-th, January, till 20-th, July.
△ Less
Submitted 29 May, 2005;
originally announced May 2005.