-
A Novel Diamond-like Carbon based photocathode for PICOSEC Micromegas detectors
Authors:
X. Wang,
R. Aleksan,
Y. Angelis,
J. Bortfeldt,
F. Brunbauer,
M. Brunoldi,
E. Chatzianagnostou,
J. Datta,
K. Degmelt,
G. Fanourakis,
D. Fiorina,
K. J. Floethner,
M. Gallinaro,
F. Garcia,
I. Giomataris,
K. Gnanvo,
F. J. Iguaz,
D. Janssens,
A. Kallitsopoulou,
M. Kovacic,
B. Kross,
P. Legou,
M. Lisowska,
J. Liu,
I. Maniatis
, et al. (26 additional authors not shown)
Abstract:
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes equipped with cesium iodide (CsI) photocathodes have shown promising time resolutions as precise as 24 picoseconds (ps) for Minimum Ionizing Particles. However, due to the high hygroscopicity and susceptibility to ion bomb…
▽ More
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes equipped with cesium iodide (CsI) photocathodes have shown promising time resolutions as precise as 24 picoseconds (ps) for Minimum Ionizing Particles. However, due to the high hygroscopicity and susceptibility to ion bombardment of the CsI photocathodes, alternative photocathode materials are needed to improve the robustness of PICOSEC MM. Diamond-like Carbon (DLC) film have been introduced as a novel robust photocathode material, which have shown promising results. A batch of DLC photocathodes with different thicknesses were produced and evaluated using ultraviolet light. The quantum efficiency measurements indicate that the optimized thickness of the DLC photocathode is approximately 3 nm. Furthermore, DLC photocathodes show good resistance to ion bombardment in aging test compared to the CsI photocathode. Finally, a PICOSEC MM prototype equipped with DLC photocathodes was tested in muon beams. A time resolution of around 42 ps with a detection efficiency of 97% for 150 GeV/c muons were obtained. These results indicate the great potential of DLC as a photocathode for the PICOSEC MM detector.
△ Less
Submitted 25 June, 2024; v1 submitted 12 June, 2024;
originally announced June 2024.
-
Single channel PICOSEC Micromegas detector with improved time resolution
Authors:
A. Utrobicic,
R. Aleksan,
Y. Angelis,
J. Bortfeldt,
F. Brunbauer,
M. Brunoldi,
E. Chatzianagnostou,
J. Datta,
K. Dehmelt,
G. Fanourakis,
D. Fiorina,
K. J. Floethner,
M. Gallinaro,
F. Garcia,
I. Giomataris,
K. Gnanvo,
F. J. Iguaz,
D. Janssens,
A. Kallitsopoulou,
M. Kovacic,
B. Kross,
P. Legou,
M. Lisowska,
J. Liu,
M. Lupberger
, et al. (25 additional authors not shown)
Abstract:
This paper presents design guidelines and experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and electrical connectivity for high voltage (HV) and signals, focusing on improving stability, reducing noise, and ensuring signal integrity to optimize timing perfo…
▽ More
This paper presents design guidelines and experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and electrical connectivity for high voltage (HV) and signals, focusing on improving stability, reducing noise, and ensuring signal integrity to optimize timing performance. A notable feature is the simple and fast reassembly procedure, facilitating quick replacement of detector internal components that allows for an efficient measurement strategy involving different detector components. The paper also examines the influence of parasitics on the output signal integrity. To validate the design, a prototype assembly and three interchangeable detector boards with varying readout pad diameters were manufactured. The detectors were initially tested in the laboratory environment. Finally, the timing performance of detectors with different pad sizes was verified using a Minimum Ionizing Particle (MIP) beam test. Notably, a record time resolution for a PICOSEC Micromegas detector technology with a CsI photocathode of 12.5$\pm$0.8 ps was achieved with a 10 mm diameter readout pad size detector.
△ Less
Submitted 9 June, 2024;
originally announced June 2024.
-
A minimal physical model for curvotaxis driven by curved protein complexes at the cell's leading edge
Authors:
Raj Kumar Sadhu,
Marine Luciano,
Wang Xi,
Cristina Martinez-Torres,
Marcel Schröder,
Christoph Blum,
Marco Tarantola,
Samo Penič,
Aleš Iglič,
Carsten Beta,
Oliver Steinbock,
Eberhard Bodenschatz,
Benoît Ladoux,
Sylvain Gabriele,
Nir S. Gov
Abstract:
Cells often migrate on curved surfaces inside the body, such as curved tissues, blood vessels or highly curved protrusions of other cells. Recent \textit{in-vitro} experiments provide clear evidence that motile cells are affected by the curvature of the substrate on which they migrate, preferring certain curvatures to others, termed ``curvotaxis". The origin and underlying mechanism that gives ris…
▽ More
Cells often migrate on curved surfaces inside the body, such as curved tissues, blood vessels or highly curved protrusions of other cells. Recent \textit{in-vitro} experiments provide clear evidence that motile cells are affected by the curvature of the substrate on which they migrate, preferring certain curvatures to others, termed ``curvotaxis". The origin and underlying mechanism that gives rise to this curvature sensitivity are not well understood. Here, we employ a ``minimal cell" model which is composed of a vesicle that contains curved membrane protein complexes, that exert protrusive forces on the membrane (representing the pressure due to actin polymerization). This minimal-cell model gives rise to spontaneous emergence of a motile phenotype, driven by a lamellipodia-like leading edge. By systematically screening the behaviour of this model on different types of curved substrates (sinusoidal, cylinder and tube), we show that minimal ingredients and energy terms capture the experimental data. The model recovers the observed migration on the sinusoidal substrate, where cells move along the grooves (minima), while avoiding motion along the ridges. In addition, the model predicts the tendency of cells to migrate circumferentially on convex substrates and axially on concave ones. Both of these predictions are verified experimentally, on several cell types. Altogether, our results identify the minimization of membrane-substrate adhesion energy and binding energy between the membrane protein complexes as key players of curvotaxis in cell migration.
△ Less
Submitted 19 April, 2023;
originally announced April 2023.
-
A two-dimensional position-sensitive microchannel plate detector realized with two independent one-dimensional resistive anodes
Authors:
Yuezhao Zhang,
Deyang Yu,
Junliang Liu,
Li** Yang,
Wei Wang,
Xiaoxiao Li,
Xiaona Zhu,
Xiaoxun Song,
Xinfei Hui,
Wei Xi,
Xin Li,
Hui** Liu,
Xiaohong Cai
Abstract:
A two-dimensional position-sensitive microchannel plate detector, with a Ø100 mm sensitive area and equipped with four integrated amplifiers, is realized with a new anode scheme. The anode is constructed by two independent one-dimensional resistive anodes, each consisting of an array of parallel copper strips connected by resistors in series on a printed circuit board. The arrays are perpendicular…
▽ More
A two-dimensional position-sensitive microchannel plate detector, with a Ø100 mm sensitive area and equipped with four integrated amplifiers, is realized with a new anode scheme. The anode is constructed by two independent one-dimensional resistive anodes, each consisting of an array of parallel copper strips connected by resistors in series on a printed circuit board. The arrays are perpendicularly aligned to realize two-dimensional position resolution, with the intervals between the adjacent strips on the PCB nearer to the MCP cut out to allow electrons passing through. The detector is tested with an 55Fe x-ray source, and a position resolution of 0.38 mm is achieved.
△ Less
Submitted 19 June, 2018;
originally announced June 2018.
-
Observation of Multiphoton-induced Fluorescence from Nano Graphene Oxide and Its Applications in In vitro and In vivo Bioimaging
Authors:
Jun Qian,
Dan Wang,
Li Peng,
Wang Xi,
Fu-Hong Cai,
Zhen-Feng Zhu,
Hao He,
Ming-Lie Hu,
Sailing He
Abstract:
In the present paper, we observed both two-photon and three-photon induced distinct photoluminescence from GO nanoparticles under fs laser excitation. Conjugated with PEG molecules, GO nanoparticles exhibited high chemical stability, and could effectively label HeLa cells. Imaged with a two-photon scanning microscope, GO nanoparticles were observed to localize in the mitochondria, endoplasmic reti…
▽ More
In the present paper, we observed both two-photon and three-photon induced distinct photoluminescence from GO nanoparticles under fs laser excitation. Conjugated with PEG molecules, GO nanoparticles exhibited high chemical stability, and could effectively label HeLa cells. Imaged with a two-photon scanning microscope, GO nanoparticles were observed to localize in the mitochondria, endoplasmic reticulum, Golgi and lysosome of HeLa cells. Furthermore, GO nanoparticles were micro-injected into the brain of a black mouse, and in vivo two-photon luminescence imaging illustrated that GO nanoparticles located at 300 μm depth in the brain could be clearly distinguished.
△ Less
Submitted 9 February, 2012;
originally announced February 2012.
-
Development of a mini-PET Detector based on Silicon Photomultiplier Arrays for Plant Imaging Applications
Authors:
F. Barbosa,
H. Dong,
B. Kross,
S. J. Lee,
Y. Mack,
J. McKisson,
J. McKisson,
A Weisenberger,
W. Xi,
C. Zorn,
S. Majewsk,
A. Stolin,
C. R. Howell,
A. S. Crowell,
C. D. Reis,
M. F. Smith
Abstract:
A mini-PET style detector system is being developed for a plant imaging application with a compact array of silicon photomultipliers (SiPM) replacing position sensitive photomultipliers (PSPMT). In addition to compactness, the use of SiPMs will allow imaging setups involving high strength MRI-type magnetic fields. The latter will allow for better position resolution of the initial positron annihil…
▽ More
A mini-PET style detector system is being developed for a plant imaging application with a compact array of silicon photomultipliers (SiPM) replacing position sensitive photomultipliers (PSPMT). In addition to compactness, the use of SiPMs will allow imaging setups involving high strength MRI-type magnetic fields. The latter will allow for better position resolution of the initial positron annihilations in the plant tissue. In the present work, prototype arrays are tested for the uniformity of their response as it is known that PSPMTs require significant gain compensation on the individual channels to achieve an improved uniformity in response. The initial tests indicate a high likelihood that the SiPM arrays can be used without any gain compensation.
△ Less
Submitted 13 January, 2011;
originally announced January 2011.