-
Accelerating proton arc therapy delivery through dosimetry-guided energy layer filtering
Authors:
S. Wuyckens,
V. Wase,
O. Marthin,
J. Sundström,
G. Janssens,
E. Borderias-Villarroel,
K. Souris,
E. Sterpin,
E. Engwall,
J. A. Lee
Abstract:
Proton arc therapy has emerged as a promising approach for faster treatment delivery in comparison to conventional proton treatments. However, unexpected prolonged treatment times in several proton arc planning studies have raised concerns. In this study, we aim to address the challenge of minimizing delivery time through dosimetry-guided energy layer filtering, comparing its performance to a base…
▽ More
Proton arc therapy has emerged as a promising approach for faster treatment delivery in comparison to conventional proton treatments. However, unexpected prolonged treatment times in several proton arc planning studies have raised concerns. In this study, we aim to address the challenge of minimizing delivery time through dosimetry-guided energy layer filtering, comparing its performance to a baseline approach without filtering. We developed three methods of energy layer (EL) filtering: unrestricted, switch-up (SU), and switch-up gap (SU gap) filtering. The unrestricted method filters the lowest weighted EL while the SU gap filtering removes in priority the EL around a new SU to minimize the gantry rotation braking. The SU filtering removes the lowest weighted group of EL that includes a SU. These post-processing filters were used in conjunction with the RayStation dynamic proton arc optimization framework (ELSA). Four bilateral oropharyngeal cancer patients' data were used for evaluation. Objective function values, target coverage robustness, organ-at-risk doses and NTCP evaluations, as well as comparisons to IMPT plans, were used to assess plan quality. The SU gap filtering algorithm performed best in three out of the four cases, maintaining plan quality within tolerance while significantly reducing beam delivery time. It achieved up to approximately 22% reduction in delivery time. The unrestricted filtering algorithm followed closely. In contrast, the SU filtering showed limited improvement, suppressing hardly a few SU without substantial delivery time shortening. Robust target coverage was kept within 1% of variation compared to the ELSA baseline plan while OAR doses slighlty decreased in all four patients. Both arc plans present large reductions in NTCP values for dysphagia and xerostomia compared to the reference IMPT plan.
△ Less
Submitted 15 September, 2023;
originally announced September 2023.
-
Beamlet-free optimization for Monte Carlo based treatment planning in proton therapy
Authors:
D. Pross,
S. Wuyckens,
S. Deffet,
E. Sterpin,
J. A. Lee,
K. Souris
Abstract:
Background: Dose calculation and optimization algorithms in proton therapy treatment planning often have high computational requirements regarding time and memory. This can hinder the implementation of efficient workflows in clinics and prevent the use of new, elaborate treatment techniques aiming to improve clinical outcomes like robust optimization, arc and adaptive proton therapy. Purpose: A ne…
▽ More
Background: Dose calculation and optimization algorithms in proton therapy treatment planning often have high computational requirements regarding time and memory. This can hinder the implementation of efficient workflows in clinics and prevent the use of new, elaborate treatment techniques aiming to improve clinical outcomes like robust optimization, arc and adaptive proton therapy. Purpose: A new method, namely, the beamlet-free algorithm, is presented to address the aforementioned issue by combining Monte Carlo dose calculation and optimization into a single algorithm and omitting the calculation of the time-consuming and costly dose influence matrix. Methods: The beamlet-free algorithm simulates the dose in proton batches of randomly chosen spots and evaluates their relative impact on the objective function at each iteration. Based on the approximated gradient, the spot weights are then updated and used to generate a new spot probability distribution. The beamlet-free method is compared against a conventional, beamlet-based treatment planning algorithm on a brain case. Results: The beamlet-free algorithm maintained a comparable plan quality while reducing the computation time by 70% and the peak memory usage by 95%. Conclusion: The implementation of a beamlet-free treatment planning algorithm for proton therapy is feasible and capable of achieving a considerable reduction of time and memory requirements.
△ Less
Submitted 17 April, 2023;
originally announced April 2023.
-
OpenTPS -- Open-source treatment planning system for research in proton therapy
Authors:
S. Wuyckens,
D. Dasnoy,
G. Janssens,
V. Hamaide,
M. Huet,
E. Loÿen,
G. Rotsart de Hertaing,
B. Macq,
E. Sterpin,
J. A. Lee,
K. Souris,
S. Deffet
Abstract:
Introduction. Treatment planning systems (TPS) are an essential component for simulating and optimizing a radiation therapy treatment before administering it to the patient. It ensures that the tumor is well covered and the dose to the healthy tissues is minimized. However, the TPS provided by commercial companies often come with a large panel of tools, each implemented in the form of a black-box…
▽ More
Introduction. Treatment planning systems (TPS) are an essential component for simulating and optimizing a radiation therapy treatment before administering it to the patient. It ensures that the tumor is well covered and the dose to the healthy tissues is minimized. However, the TPS provided by commercial companies often come with a large panel of tools, each implemented in the form of a black-box making it difficult for researchers to use them for implementing and testing new ideas. To address this issue, we have developed an open-source TPS. Approach. We have developed an open-source software platform, OpenTPS (opentps.org), to generate treatment plans for external beam radiation therapy, and in particular for proton therapy. It is designed to be a flexible and user-friendly platform (coded with the freely usable Python language) that can be used by medical physicists, radiation oncologists, and other members of the radiation therapy community to create customized treatment plans for educational and research purposes. Result. OpenTPS includes a range of tools and features that can be used to analyze patient anatomy, simulate the delivery of the radiation beam, and optimize the treatment plan to achieve the desired dose distribution. It can be used to create treatment plans for a variety of cancer types and was designed to be extended to other treatment modalities. Significance. A new open-source treatment planning system has been built for research in proton therapy. Its flexibility allows an easy integration of new techniques and customization of treatment plans. It is freely available for use and is regularly updated and supported by a community of users and developers who contribute to the ongoing development and improvement of the software.
△ Less
Submitted 1 March, 2023;
originally announced March 2023.
-
Towards portable muography with small-area, gas-tight glass Resistive Plate Chambers
Authors:
S. Basnet,
E. Cortina Gil,
P. Demin,
R. M. I. D. Gamage,
A. Giammanco,
M. Moussawi,
M. Tytgat,
S. Wuyckens
Abstract:
Imaging techniques that use atmospheric muons, collectively named under the neologism "muography", have seen a tremendous growth in recent times, mainly due to their diverse range of applications. The most well-known ones include but are not limited to: volcanology, archaeology, civil engineering, nuclear reactor monitoring, nuclear waste characterization, underground map**, etc. These methods a…
▽ More
Imaging techniques that use atmospheric muons, collectively named under the neologism "muography", have seen a tremendous growth in recent times, mainly due to their diverse range of applications. The most well-known ones include but are not limited to: volcanology, archaeology, civil engineering, nuclear reactor monitoring, nuclear waste characterization, underground map**, etc. These methods are based on the attenuation or deviation of muons to image large and/or dense objects where conventional techniques cannot work or their use becomes challenging.
In this context, we have constructed a muography telescope based on "mini glass-RPC planes" following a design similar to the glass-RPC detectors developed by the CALICE Collaboration and used by the TOMUVOL experiment in the context of volcano radiography, but with smaller active area (16 $\times$ 16 cm$^{2}$). The compact size makes it an attractive choice with respect to other detectors previously employed for imaging on similar scales. An important innovation in this design is that the detectors are sealed. This makes the detector more portable and solves the usual safety and logistic issues for gas detectors operated underground and/or inside small rooms. This paper provides an overview on our guiding principles, the detector development and our operational experiences. Drawing on the lessons learnt from the first prototype, we also discuss our future direction for an improved second prototype, focusing primarily on a recently adopted serigraphy technique for the resistive coating of the glass plates.
△ Less
Submitted 8 December, 2020; v1 submitted 19 May, 2020;
originally announced May 2020.
-
A portable muon telescope based on small and gas-tight Resistive Plate Chambers
Authors:
Sophie Wuyckens,
Andrea Giammanco,
Pavel Demin,
Eduardo Cortina Gil
Abstract:
We report on the first steps in the development of a small-size muon telescope based on glass Resistive Plate Chambers with small active area ($16\times 16~{\rm cm}^2$). The long-term goal of this project is to focus on applications of muography where the telescope may have to be operated underground and/or inside small rooms, and in challenging logistic situations. Driving principles in our desig…
▽ More
We report on the first steps in the development of a small-size muon telescope based on glass Resistive Plate Chambers with small active area ($16\times 16~{\rm cm}^2$). The long-term goal of this project is to focus on applications of muography where the telescope may have to be operated underground and/or inside small rooms, and in challenging logistic situations. Driving principles in our design are therefore compact size, light weight, gas tightness, and robustness. The first data-taking experiences have been encouraging, and we elaborate on the lessons learnt and future directions for development.
△ Less
Submitted 18 December, 2018; v1 submitted 18 June, 2018;
originally announced June 2018.