-
The OLYMPUS Experiment
Authors:
R. Milner,
D. K. Hasell,
M. Kohl,
U. Schneekloth,
N. Akopov,
R. Alarcon,
V. A. Andreev,
O. Ates,
A. Avetisyan,
D. Bayadilov,
R. Beck,
S. Belostotski,
J. C. Bernauer,
J. Bessuille,
F. Brinker,
B. Buck,
J. R. Calarco,
V. Carassiti,
E. Cisbani,
G. Ciullo,
M. Contalbrigo,
N. D'Ascenzo,
R. De Leo,
J. Diefenbach,
T. W. Donnelly
, et al. (48 additional authors not shown)
Abstract:
The OLYMPUS experiment was designed to measure the ratio between the positron-proton and electron-proton elastic scattering cross sections, with the goal of determining the contribution of two-photon exchange to the elastic cross section. Two-photon exchange might resolve the discrepancy between measurements of the proton form factor ratio, $μ_p G^p_E/G^p_M$, made using polarization techniques and…
▽ More
The OLYMPUS experiment was designed to measure the ratio between the positron-proton and electron-proton elastic scattering cross sections, with the goal of determining the contribution of two-photon exchange to the elastic cross section. Two-photon exchange might resolve the discrepancy between measurements of the proton form factor ratio, $μ_p G^p_E/G^p_M$, made using polarization techniques and those made in unpolarized experiments. OLYMPUS operated on the DORIS storage ring at DESY, alternating between 2.01~GeV electron and positron beams incident on an internal hydrogen gas target. The experiment used a toroidal magnetic spectrometer instrumented with drift chambers and time-of-flight detectors to measure rates for elastic scattering over the polar angular range of approximately $25^\circ$--$75^\circ$. Symmetric Møller/Bhabha calorimeters at $1.29^\circ$ and telescopes of GEM and MWPC detectors at $12^\circ$ served as luminosity monitors. A total luminosity of approximately 4.5~fb$^{-1}$ was collected over two running periods in 2012. This paper provides details on the accelerator, target, detectors, and operation of the experiment.
△ Less
Submitted 5 December, 2013;
originally announced December 2013.
-
DarkLight: A Search for Dark Forces at the Jefferson Laboratory Free-Electron Laser Facility
Authors:
J. Balewski,
J. Bernauer,
W. Bertozzi,
J. Bessuille,
B. Buck,
R. Cowan,
K. Dow,
C. Epstein,
P. Fisher,
S. Gilad,
E. Ihloff,
Y. Kahn,
A. Kelleher,
J. Kelsey,
R. Milner,
C. Moran,
L. Ou,
R. Russell,
B. Schmookler,
J. Thaler,
C. Tschalär,
C. Vidal,
A. Winnebeck,
S. Benson,
C. Gould
, et al. (42 additional authors not shown)
Abstract:
We give a short overview of the DarkLight detector concept which is designed to search for a heavy photon A' with a mass in the range 10 MeV/c^2 < m(A') < 90 MeV/c^2 and which decays to lepton pairs. We describe the intended operating environment, the Jefferson Laboratory free electon laser, and a way to extend DarkLight's reach using A' --> invisible decays.
We give a short overview of the DarkLight detector concept which is designed to search for a heavy photon A' with a mass in the range 10 MeV/c^2 < m(A') < 90 MeV/c^2 and which decays to lepton pairs. We describe the intended operating environment, the Jefferson Laboratory free electon laser, and a way to extend DarkLight's reach using A' --> invisible decays.
△ Less
Submitted 19 July, 2013; v1 submitted 16 July, 2013;
originally announced July 2013.
-
Technical Design Report for the: PANDA Micro Vertex Detector
Authors:
PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
Q. Wang,
H. Xu,
M. Albrecht,
J. Becker,
K. Eickel,
F. Feldbauer,
M. Fink,
P. Friedel,
F. H. Heinsius,
T. Held,
H. Koch,
B. Kopf,
M. Leyhe,
C. Motzko,
M. Pelizäus,
J. Pychy
, et al. (436 additional authors not shown)
Abstract:
This document illustrates the technical layout and the expected performance of the Micro Vertex Detector (MVD) of the PANDA experiment. The MVD will detect charged particles as close as possible to the interaction zone. Design criteria and the optimisation process as well as the technical solutions chosen are discussed and the results of this process are subjected to extensive Monte Carlo physics…
▽ More
This document illustrates the technical layout and the expected performance of the Micro Vertex Detector (MVD) of the PANDA experiment. The MVD will detect charged particles as close as possible to the interaction zone. Design criteria and the optimisation process as well as the technical solutions chosen are discussed and the results of this process are subjected to extensive Monte Carlo physics studies. The route towards realisation of the detector is outlined.
△ Less
Submitted 10 August, 2012; v1 submitted 27 July, 2012;
originally announced July 2012.
-
Development of a GEM-TPC prototype
Authors:
Heinz Angerer,
Reinhard Beck,
Martin Berger,
Felix Boehmer,
K. -T. Brinkmann,
Paul Buehler,
Michael Carnegie,
Sverre Dorheim,
Laura Fabbietti,
Chr. Funke,
F. Cusanno,
Joerg Hehner,
Andreas Heinz,
Markus Henske,
Christian Hoeppner,
David Kaiser,
Bernhard Ketzer,
Igor Konorov,
Jochen Kunkel,
Michael Lang,
Johann Marton,
Sebastian Neubert,
Stephan Paul,
Alexander Schmah,
Christian Schmidt
, et al. (15 additional authors not shown)
Abstract:
The use of GEM foils for the amplification stage of a TPC instead of a con- ventional MWPC allows one to bypass the necessity of gating, as the backdrift is suppressed thanks to the asymmetric field configuration. This way, a novel continuously running TPC, which represents one option for the PANDA central tracker, can be realized. A medium sized prototype with a diameter of 300 mm and a length…
▽ More
The use of GEM foils for the amplification stage of a TPC instead of a con- ventional MWPC allows one to bypass the necessity of gating, as the backdrift is suppressed thanks to the asymmetric field configuration. This way, a novel continuously running TPC, which represents one option for the PANDA central tracker, can be realized. A medium sized prototype with a diameter of 300 mm and a length of 600 mm will be tested inside the FOPI spectrometer at GSI using a carbon or lithium beam at intermediate energies (E = 1-3AGeV). This detector test under realistic experimental conditions should allow us to verify the spatial resolution for single tracks and the reconstruction capability for displaced vertexes. A series of physics measurement implying pion beams is scheduled with the FOPI spectrometer together with the GEM-TPC as well.
△ Less
Submitted 4 November, 2009;
originally announced November 2009.