-
Continuous Generation of Volumetric Images During Stereotactic Body Radiation Therapy Using Periodic kV Imaging and an External Respiratory Surrogate
Authors:
Matthieu Lafrenière,
Nitin Mahadeo,
John Lewis,
Joerg Rottmann,
Christopher L. Williams
Abstract:
We present a technique for continuous generation of volumetric images during SBRT using periodic kV imaging and an external respiratory surrogate signal to drive a patient-specific PCA motion model. Using the on-board imager, kV radiographs are acquired every 3 seconds and used to fit the parameters of a motion model so that it matches observed changes in internal patient anatomy. A multi-dimensio…
▽ More
We present a technique for continuous generation of volumetric images during SBRT using periodic kV imaging and an external respiratory surrogate signal to drive a patient-specific PCA motion model. Using the on-board imager, kV radiographs are acquired every 3 seconds and used to fit the parameters of a motion model so that it matches observed changes in internal patient anatomy. A multi-dimensional correlation model is established between the motion model parameters and the external surrogate position and velocity, enabling volumetric image reconstruction between kV imaging time points. Performance of the algorithm was evaluated using 10 realistic eXtended CArdiac-Torso (XCAT) digital phantoms including 3D anatomical respiratory deformation programmed with 3D tumor positions measured with orthogonal kV imaging of implanted fiducial gold markers. The clinically measured ground truth 3D tumor positions provided a dataset with realistic breathing irregularities, and the combination of periodic on-board kV imaging with recorded external respiratory surrogate signal was used for correlation modeling to account for any changes in internal-external correlation. The three-dimensional tumor positions are reconstructed with an average root mean square error (RMSE) of 1.47 mm, and an average 95th percentile 3D positional error of 2.80 mm compared with the clinically measured ground truth 3D tumor positions. This technique enables continuous 3D anatomical image generation based on periodic kV imaging of internal anatomy without the additional dose of continuous kV imaging. The 3D anatomical images produced using this method can be used for treatment verification and delivered dose computation in the presence of irregular respiratory motion.
△ Less
Submitted 26 April, 2019; v1 submitted 24 August, 2018;
originally announced August 2018.
-
Generalized Fourier transform method for nonlinear anomalous diffusion equation
Authors:
Jie Yao,
Cameron L. Williams,
Fazle Hussain,
Donald J. Kouri
Abstract:
The solution of a nonlinear diffusion equation is numerically investigated using the generalized Fourier transform method. This equation includes fractal dimensions and power-law dependence on the radial variable and on the diffusion function. The generalized Fourier transform approach is the extension of the Fourier transform method used for normal diffusion equation. The feasibility of the appro…
▽ More
The solution of a nonlinear diffusion equation is numerically investigated using the generalized Fourier transform method. This equation includes fractal dimensions and power-law dependence on the radial variable and on the diffusion function. The generalized Fourier transform approach is the extension of the Fourier transform method used for normal diffusion equation. The feasibility of the approach is validated by comparing the numerical result with the exact solution for point-source. The merit of numerical method is that it provide a way to calculate anomalous diffusion with an arbitrary initial condition.
△ Less
Submitted 9 November, 2019; v1 submitted 12 January, 2017;
originally announced January 2017.
-
Power spectrum analysis of ionospheric fluctuations with the Murchison Widefield Array
Authors:
Shyeh T**g Loi,
Cathryn M. Trott,
Tara Murphy,
Iver H. Cairns,
Martin Bell,
Natasha Hurley-Walker,
John Morgan,
Emil Lenc,
A. R. Offringa,
L. Feng,
P. J. Hancock,
D. L. Kaplan,
N. Kudryavtseva,
G. Bernardi,
J. D. Bowman,
F. Briggs,
R. J. Cappallo,
B. E. Corey,
A. A. Deshpande,
D. Emrich,
B. M. Gaensler,
R. Goeke,
L. J. Greenhill,
B. J. Hazelton,
M. Johnston-Hollitt
, et al. (23 additional authors not shown)
Abstract:
Low-frequency, wide field-of-view (FoV) radio telescopes such as the Murchison Widefield Array (MWA) enable the ionosphere to be sampled at high spatial completeness. We present the results of the first power spectrum analysis of ionospheric fluctuations in MWA data, where we examined the position offsets of radio sources appearing in two datasets. The refractive shifts in the positions of celesti…
▽ More
Low-frequency, wide field-of-view (FoV) radio telescopes such as the Murchison Widefield Array (MWA) enable the ionosphere to be sampled at high spatial completeness. We present the results of the first power spectrum analysis of ionospheric fluctuations in MWA data, where we examined the position offsets of radio sources appearing in two datasets. The refractive shifts in the positions of celestial sources are proportional to spatial gradients in the electron column density transverse to the line of sight. These can be used to probe plasma structures and waves in the ionosphere. The regional (10-100 km) scales probed by the MWA, determined by the size of its FoV and the spatial density of radio sources (typically thousands in a single FoV), complement the global (100-1000 km) scales of GPS studies and local (0.01-1 km) scales of radar scattering measurements. Our data exhibit a range of complex structures and waves. Some fluctuations have the characteristics of travelling ionospheric disturbances (TIDs), while others take the form of narrow, slowly-drifting bands aligned along the Earth's magnetic field.
△ Less
Submitted 5 June, 2015;
originally announced June 2015.
-
Real-time imaging of density ducts between the plasmasphere and ionosphere
Authors:
Shyeh T**g Loi,
Tara Murphy,
Iver H. Cairns,
Frederick W. Menk,
Colin L. Waters,
Philip J. Erickson,
Cathryn M. Trott,
Natasha Hurley-Walker,
John Morgan,
Emil Lenc,
Andre R. Offringa,
Martin E. Bell,
Ronald D. Ekers,
B. M. Gaensler,
Colin J. Lonsdale,
Lu Feng,
Paul J. Hancock,
David L. Kaplan,
G. Bernardi,
J. D. Bowman,
F. Briggs,
R. J. Cappallo,
A. A. Deshpande,
L. J. Greenhill,
B. J. Hazelton
, et al. (16 additional authors not shown)
Abstract:
Ionization of the Earth's atmosphere by sunlight forms a complex, multi-layered plasma environment within the Earth's magnetosphere, the innermost layers being the ionosphere and plasmasphere. The plasmasphere is believed to be embedded with cylindrical density structures (ducts) aligned along the Earth's magnetic field, but direct evidence for these remains scarce. Here we report the first direct…
▽ More
Ionization of the Earth's atmosphere by sunlight forms a complex, multi-layered plasma environment within the Earth's magnetosphere, the innermost layers being the ionosphere and plasmasphere. The plasmasphere is believed to be embedded with cylindrical density structures (ducts) aligned along the Earth's magnetic field, but direct evidence for these remains scarce. Here we report the first direct wide-angle observation of an extensive array of field-aligned ducts bridging the upper ionosphere and inner plasmasphere, using a novel ground-based imaging technique. We establish their heights and motions by feature-tracking and parallax analysis. The structures are strikingly organized, appearing as regularly-spaced, alternating tubes of overdensities and underdensities strongly aligned with the Earth's magnetic field. These findings represent the first direct visual evidence for the existence of such structures.
△ Less
Submitted 24 April, 2015;
originally announced April 2015.
-
A Mass-Conserving 4D XCAT Phantom for Dose Calculation and Accumulation
Authors:
Christopher L. Williams,
Pankaj Mishra,
Joao Seco,
Sara St. James,
Raymond H. Mak,
Ross I. Berbeco,
John H. Lewis
Abstract:
The XCAT phantom is a realistic 4D digital torso phantom that is widely used in imaging and therapy research. However, lung mass is not conserved between respiratory phases of the phantom, making detailed dosimetric simulations and dose accumulation unphysical. A framework is developed to correct this issue by enforcing local mass conservation in the XCAT lung. Dose calculations are performed to a…
▽ More
The XCAT phantom is a realistic 4D digital torso phantom that is widely used in imaging and therapy research. However, lung mass is not conserved between respiratory phases of the phantom, making detailed dosimetric simulations and dose accumulation unphysical. A framework is developed to correct this issue by enforcing local mass conservation in the XCAT lung. Dose calculations are performed to assess the implications of neglecting mass conservation, and to demonstrate an application of the phantom to calculate the accumulated delivered dose in an irregularly breathing patient. Monte Carlo methods are used to simulate conventional and SBRT treatment delivery. The spatial distribution of the lung dose was qualitatively changed by the use of mass conservation; however the corresponding DVH did not change significantly. Comparison of the delivered dose with 4DCT-based predictions shows similar lung metric results, however dose differences of 10% can be seen in some spatial regions. Using this tool to simulate patient treatments reveals differences between the planned dose and the calculated delivered dose for the full treatment. The software is freely available from the authors.
△ Less
Submitted 18 June, 2013;
originally announced June 2013.
-
Realisation of a low frequency SKA Precursor: The Murchison Widefield Array
Authors:
S. J. Tingay,
R. Goeke,
J. N. Hewitt,
E. Morgan,
R. A Remillard,
C. L. Williams,
J. D. Bowman,
D. Emrich,
S. M. Ord,
T. Booler,
B. Crosse,
D. Pallot,
W. Arcus,
T. Colegate,
P. J. Hall,
D. Herne,
M. J. Lynch,
F. Schlagenhaufer,
S. Tremblay,
R. B. Wayth,
M. Waterson,
D. A. Mitchell,
R. J. Sault,
R. L. Webster,
J. S. B. Wyithe
, et al. (34 additional authors not shown)
Abstract:
The Murchison Widefield Array is a low frequency (80 - 300 MHz) SKA Precursor, comprising 128 aperture array elements distributed over an area of 3 km diameter. The MWA is located at the extraordinarily radio quiet Murchison Radioastronomy Observatory in the mid-west of Western Australia, the selected home for the Phase 1 and Phase 2 SKA low frequency arrays. The MWA science goals include: 1) dete…
▽ More
The Murchison Widefield Array is a low frequency (80 - 300 MHz) SKA Precursor, comprising 128 aperture array elements distributed over an area of 3 km diameter. The MWA is located at the extraordinarily radio quiet Murchison Radioastronomy Observatory in the mid-west of Western Australia, the selected home for the Phase 1 and Phase 2 SKA low frequency arrays. The MWA science goals include: 1) detection of fluctuations in the brightness temperature of the diffuse redshifted 21 cm line of neutral hydrogen from the epoch of reionisation; 2) studies of Galactic and extragalactic processes based on deep, confusion-limited surveys of the full sky visible to the array; 3) time domain astrophysics through exploration of the variable radio sky; and 4) solar imaging and characterisation of the heliosphere and ionosphere via propagation effects on background radio source emission. This paper will focus on a brief discussion of the as-built MWA system, highlighting several novel characteristics of the instrument, and a brief progress report (as of June 2012) on the final construction phase. Practical completion of the MWA is expected in November 2012, with commissioning commencing from approximately August 2012 and operations commencing near mid 2013. A brief description of recent science results from the MWA prototype instrument is given.
△ Less
Submitted 6 December, 2012;
originally announced December 2012.