Additive Manufacturing of functionalised atomic vapour cells for next-generation quantum technologies
Authors:
Feiran Wang,
Nathan Cooper,
Yinfeng He,
Benjamin Hopton,
David Johnson,
Peng Zhao,
T. Mark Fromhold,
Christopher J. Tuck,
Richard Hague,
Ricky D. Wildman,
Lyudmila Turyanska,
Lucia Hackermüller
Abstract:
Atomic vapour cells are an indispensable tool for quantum technologies (QT), but potential improvements are limited by the capacities of conventional manufacturing methods. Using an additive manufacturing (AM) technique - vat polymerisation by digital light processing - we demonstrate, for the first time, a 3D-printed glass vapour cell. The exploitation of AM capacities allows intricate internal a…
▽ More
Atomic vapour cells are an indispensable tool for quantum technologies (QT), but potential improvements are limited by the capacities of conventional manufacturing methods. Using an additive manufacturing (AM) technique - vat polymerisation by digital light processing - we demonstrate, for the first time, a 3D-printed glass vapour cell. The exploitation of AM capacities allows intricate internal architectures, overprinting of 2D optoelectronical materials to create integrated sensors and surface functionalisation, while also showing the ability to tailor the optical properties of the AM glass by in-situ growth of gold nanoparticles. The produced cells achieve ultra-high vacuum of $2 \times 10^{-9}$ mbar and enable Doppler-free spectroscopy; we demonstrate laser frequency stabilisation as a QT application. These results highlight the transformative role that AM can play for QT in enabling compact, optimised and integrated multi-material components and devices.
△ Less
Submitted 21 June, 2024;
originally announced June 2024.
-
Additively manufactured ultra-high vacuum chamber below $10^{-10}$ mbar
Authors:
N. Cooper,
L. A. Coles,
S. Everton,
R. P. Campion,
S. Madkhaly,
C. Morley,
W. Evans,
R. Saint,
P. Krüger,
F. Oručević,
C. Tuck,
R. D. Wildman,
T. M. Fromhold,
L. Hackermueller
Abstract:
Metal-based additive manufacturing (AM) represents a paradigm change in engineering and production methods across multiple industries and sectors. AM methods enable mass reduction and performance optimisation well beyond that achievable via conventional manufacturing, thereby impacting significantly on aerospace and space technologies. Technologies relying on high and ultra-high vacuum (UHV), such…
▽ More
Metal-based additive manufacturing (AM) represents a paradigm change in engineering and production methods across multiple industries and sectors. AM methods enable mass reduction and performance optimisation well beyond that achievable via conventional manufacturing, thereby impacting significantly on aerospace and space technologies. Technologies relying on high and ultra-high vacuum (UHV), such as x-ray photo-electron spectroscopy, photo-sensors, cameras and cryostats, could also benefit greatly from AM. Despite recent advances in AM processing of metals, additively manufactured UHV chambers have so far not been achieved. Reducing the mass of UHV equipment is particularly critical for the development of portable cold atom systems, which are expected to underpin the next generation of sensing and timekee** technologies and to allow novel space-based sensors for fundamental research. We demonstrate here an additively manufactured UHV chamber reaching a pressure below $10^{-10}$ mbar, enabling a cloud of cold $^{85}$Rb atoms to be trapped - the starting point for many precision timekee** and sensing devices. The chamber is manufactured from aluminium alloy AlSi10Mg by laser powder bed fusion and has a mass of less than a third of a commercially-available equivalent. Outgassing analysis based on mass spectrometry was performed and it was demonstrated that even without active pum** the system remains in the $10^{-9}$ mbar regime for up to 48 hours.
△ Less
Submitted 12 December, 2019; v1 submitted 15 March, 2019;
originally announced March 2019.
-
First measurement of muon-neutrino disappearance in NOvA
Authors:
P. Adamson,
C. Ader,
M. Andrews,
N. Anfimov,
I. Anghel,
K. Arms,
E. Arrieta-Diaz,
A. Aurisano,
D. Ayres,
C. Backhouse,
M. Baird,
B. A. Bambah,
K. Bays,
R. Bernstein,
M. Betancourt,
V. Bhatnagar,
B. Bhuyan,
J. Bian,
K. Biery,
T. Blackburn,
V. Bocean,
D. Bogert,
A. Bolshakova,
M. Bowden,
C. Bower
, et al. (235 additional authors not shown)
Abstract:
This paper reports the first measurement using the NOvA detectors of $ν_μ$ disappearance in a $ν_μ$ beam. The analysis uses a 14 kton-equivalent exposure of $2.74 \times 10^{20}$ protons-on-target from the Fermilab NuMI beam. Assuming the normal neutrino mass hierarchy, we measure $Δm^{2}_{32}=(2.52^{+0.20}_{-0.18})\times 10^{-3}$ eV$^{2}$ and $\sin^2θ_{23}$ in the range 0.38-0.65, both at the 68%…
▽ More
This paper reports the first measurement using the NOvA detectors of $ν_μ$ disappearance in a $ν_μ$ beam. The analysis uses a 14 kton-equivalent exposure of $2.74 \times 10^{20}$ protons-on-target from the Fermilab NuMI beam. Assuming the normal neutrino mass hierarchy, we measure $Δm^{2}_{32}=(2.52^{+0.20}_{-0.18})\times 10^{-3}$ eV$^{2}$ and $\sin^2θ_{23}$ in the range 0.38-0.65, both at the 68% confidence level, with two statistically-degenerate best fit points at $\sin^2θ_{23} = $ 0.43 and 0.60. Results for the inverted mass hierarchy are also presented.
△ Less
Submitted 20 January, 2016; v1 submitted 19 January, 2016;
originally announced January 2016.
-
First measurement of electron neutrino appearance in NOvA
Authors:
P. Adamson,
C. Ader,
M. Andrews,
N. Anfimov,
I. Anghel,
K. Arms,
E. Arrieta-Diaz,
A. Aurisano,
D. S. Ayres,
C. Backhouse,
M. Baird,
B. A. Bambah,
K. Bays,
R. Bernstein,
M. Betancourt,
V. Bhatnagar,
B. Bhuyan,
J. Bian,
K. Biery,
T. Blackburn,
V. Bocean,
D. Bogert,
A. Bolshakova,
M. Bowden,
C. Bower
, et al. (235 additional authors not shown)
Abstract:
We report results from the first search for $ν_μ\toν_e$ transitions by the NOvA experiment. In an exposure equivalent to $2.74\times10^{20}$ protons-on-target in the upgraded NuMI beam at Fermilab, we observe 6 events in the Far Detector, compared to a background expectation of $0.99\pm0.11$ (syst.) events based on the Near Detector measurement. A secondary analysis observes 11 events with a backg…
▽ More
We report results from the first search for $ν_μ\toν_e$ transitions by the NOvA experiment. In an exposure equivalent to $2.74\times10^{20}$ protons-on-target in the upgraded NuMI beam at Fermilab, we observe 6 events in the Far Detector, compared to a background expectation of $0.99\pm0.11$ (syst.) events based on the Near Detector measurement. A secondary analysis observes 11 events with a background of $1.07\pm0.14$ (syst.). The $3.3σ$ excess of events observed in the primary analysis disfavors $0.1π< δ_{CP} < 0.5π$ in the inverted mass hierarchy at the 90% C.L.
△ Less
Submitted 2 May, 2016; v1 submitted 19 January, 2016;
originally announced January 2016.
-
Design and High Power Testing of 52.809 MHz RF Cavities for Slip Stacking in the Fermilab Recycler
Authors:
R. Madrak,
D. Wildman
Abstract:
For NOvA and future experiments requiring high intensity proton beams, Fermilab is in the process of upgrading the existing accelerator complex for increased proton production. One such improvement is to reduce the Main Injector cycle time, by performing slip stacking, previously done in the Main Injector, in the now repurposed Recycler Ring. Recycler slip stacking requires two new RF cavities ope…
▽ More
For NOvA and future experiments requiring high intensity proton beams, Fermilab is in the process of upgrading the existing accelerator complex for increased proton production. One such improvement is to reduce the Main Injector cycle time, by performing slip stacking, previously done in the Main Injector, in the now repurposed Recycler Ring. Recycler slip stacking requires two new RF cavities operating at slightly different frequencies (df = 1260Hz). These are copper, coaxial, quarter wave cavities with R/Q =13 ohms. They operate at a peak gap voltage of 150 kV with 150 kW peak drive power (60% duty factor), and are resonant at 52.809 MHz with a 10 kHz tuning range. Two have been completed and installed. The design, high power test results, and status of the cavities are presented.
△ Less
Submitted 19 September, 2014;
originally announced September 2014.
-
Perpendicularly Biased YIG Tuners for the Fermilab Recycler 52.809 MHz Cavities
Authors:
R. Madrak,
V. Kashikhin,
A. Makarov,
D. Wildman
Abstract:
For NOvA and future experiments requiring high intensity proton beams, Fermilab is in the process of upgrading the existing accelerator complex for increased proton production. One such improvement is to reduce the Main Injector cycle time, by performing slip stacking, previously done in the Main Injector, in the now repurposed Recycler Ring. Recycler slip stacking requires new tuneable RF cavitie…
▽ More
For NOvA and future experiments requiring high intensity proton beams, Fermilab is in the process of upgrading the existing accelerator complex for increased proton production. One such improvement is to reduce the Main Injector cycle time, by performing slip stacking, previously done in the Main Injector, in the now repurposed Recycler Ring. Recycler slip stacking requires new tuneable RF cavities, discussed separately in these proceedings. These are quarter wave cavities resonant at 52.809 MHz with a 10 kHz tuning range. The 10 kHz range is achieved by use of a tuner which has an electrical length of approximately one half wavelength at 52.809 MHz. The tuner is constructed from 3 1/8 inch diameter rigid coaxial line, with 5 inches of its length containing perpendicularly biased, Al doped Yttrium Iron Garnet (YIG). The tuner design, measurements, and high power test results are presented.
△ Less
Submitted 19 September, 2014;
originally announced September 2014.
-
The Six-Cavity Test - Demonstrated Acceleration of Beam with Multiple RF Cavities and a Single Klystron
Authors:
J. Steimel,
J. -P. Carneiro,
B. Chase,
E. Cullerton,
B. M. Hanna,
R. L. Madrak,
R. J. Pasquinelli,
L. R. Prost,
L. Ristori,
V. E. Scarpine,
P. Varghese,
R. C. Webber,
D. Wildman
Abstract:
The High Intensity Neutrino Source (HINS) Six-Cavity Test has demonstrated the use of high power RF vector modulators to control multiple RF cavities driven by a single high power klystron to accelerate a non-relativistic beam. Installation of 6 cavities in the existing HINS beamline has been completed and beam measurements have started. We present data showing the energy stability of the 7 mA pro…
▽ More
The High Intensity Neutrino Source (HINS) Six-Cavity Test has demonstrated the use of high power RF vector modulators to control multiple RF cavities driven by a single high power klystron to accelerate a non-relativistic beam. Installation of 6 cavities in the existing HINS beamline has been completed and beam measurements have started. We present data showing the energy stability of the 7 mA proton beam accelerated through the six cavities from 2.5 MeV to 3.4 MeV.
△ Less
Submitted 29 January, 2013;
originally announced January 2013.
-
Status and specifications of a Project X front-end accelerator test facility at Fermilab
Authors:
J. Steimel,
R. Webber,
R. Madrak,
D. Wildman,
R. Pasquinelli,
E. Evans-Peoples
Abstract:
This paper describes the construction and operational status of an accelerator test facility for Project X. The purpose of this facility is for Project X component development activities that benefit from beam tests and any development activities that require 325 MHz or 650 MHz RF power. It presently includes an H- beam line, a 325 MHz superconducting cavity test facility, a 325 MHz (pulsed) RF po…
▽ More
This paper describes the construction and operational status of an accelerator test facility for Project X. The purpose of this facility is for Project X component development activities that benefit from beam tests and any development activities that require 325 MHz or 650 MHz RF power. It presently includes an H- beam line, a 325 MHz superconducting cavity test facility, a 325 MHz (pulsed) RF power source, and a 650 MHz (CW) RF power source. The paper also discusses some specific Project X components that will be tested in the facility.
△ Less
Submitted 16 August, 2012;
originally announced August 2012.
-
Design Methodology and Considerations for NOVA 53 MHZ RF Cavities
Authors:
C. Ader,
D. W. Wildman
Abstract:
The NOνA Experiment will construct a detector optimized for electron neutrino detection in the existing Neutrino at Main Injector (NuMI) beamline. This beamline is capable of operating at 400 kW of primary beam power and the upgrade will allow up to 700 kW. The cavities will operate at 53 MHz and three of them will be installed in the Recycler beamline. Thermal stability of the cavities is crucial…
▽ More
The NOνA Experiment will construct a detector optimized for electron neutrino detection in the existing Neutrino at Main Injector (NuMI) beamline. This beamline is capable of operating at 400 kW of primary beam power and the upgrade will allow up to 700 kW. The cavities will operate at 53 MHz and three of them will be installed in the Recycler beamline. Thermal stability of the cavities is crucial since this affects the tuning. Results of finite element thermal and structural analysis involving the copper RF cavity will be presented.
△ Less
Submitted 17 July, 2012;
originally announced July 2012.
-
First high power pulsed tests of a dressed 325 MHz superconducting single spoke resonator at Fermilab
Authors:
R. Madrak,
J. Branlard,
B. Chase,
C. Darve,
P. Joireman,
T. Khabiboulline,
A. Mukherjee,
T. Nicol,
E. Peoples-Evans,
D. Peterson,
Y. Pischalnikov,
L. Ristori,
W. Schappert,
D. Sergatskov,
W. Soyars,
J. Steimel,
I. Terechkine,
V. Tupikov,
R. Wagner,
R. C. Webber,
D. Wildman
Abstract:
In the recently commissioned superconducting RF cavity test facility at Fermilab (SCTF), a 325 MHz, β=0.22 superconducting single-spoke resonator (SSR1) has been tested for the first time with its input power coupler. Previously, this cavity had been tested CW with a low power, high Qext test coupler; first as a bare cavity in the Fermilab Vertical Test Stand and then fully dressed in the SCTF. Fo…
▽ More
In the recently commissioned superconducting RF cavity test facility at Fermilab (SCTF), a 325 MHz, β=0.22 superconducting single-spoke resonator (SSR1) has been tested for the first time with its input power coupler. Previously, this cavity had been tested CW with a low power, high Qext test coupler; first as a bare cavity in the Fermilab Vertical Test Stand and then fully dressed in the SCTF. For the tests described here, the design input coupler with Qext ~ 106 was used. Pulsed power was provided by a Toshiba E3740A 2.5 MW klystron.
△ Less
Submitted 17 February, 2012;
originally announced February 2012.
-
Experiences with the Fermilab HINS 325 MHz RFQ
Authors:
R. C. Webber,
T. Khabiboulline,
R. Madrak,
G. Romanov,
V. Scarpine,
J. Steimel,
D. Wildman
Abstract:
The Fermilab High Intensity Neutrino Source program has built and commissioned a pulsed 325 MHz RFQ. The RFQ has successfully accelerated a proton beam at the RFQ design RF power. Experiences encountered during RFQ conditioning, including the symptoms and cause of a run-away detuning problem, and the first beam results are first reported.
The Fermilab High Intensity Neutrino Source program has built and commissioned a pulsed 325 MHz RFQ. The RFQ has successfully accelerated a proton beam at the RFQ design RF power. Experiences encountered during RFQ conditioning, including the symptoms and cause of a run-away detuning problem, and the first beam results are first reported.
△ Less
Submitted 7 February, 2012;
originally announced February 2012.
-
Tevatron Electron Lenses: Design and Operation
Authors:
Vladimir Shiltsev,
Kip Bishofberger,
Vsevolod Kamerdzhiev,
Sergei Kozub,
Matthew Kufer,
Gennady Kuznetsov,
Alexander Martinez,
Marvin Olson,
Howard Pfeffer,
Greg Saewert,
Vic Scarpine,
Andrey Seryi,
Nikolai Solyak,
Veniamin Sytnik,
Mikhail Tiunov,
Leonid Tkachenko,
David Wildman,
Daniel Wolff,
Xiao-Long Zhang
Abstract:
The beam-beam effects have been the dominating sources of beam loss and lifetime limitations in the Tevatron proton-antiproton collider [1]. Electron lenses were originally proposed for compensation of electromagnetic long-range and head-on beam-beam interactions of proton and antiproton beams [2]. Results of successful employment of two electron lenses built and installed in the Tevatron are re…
▽ More
The beam-beam effects have been the dominating sources of beam loss and lifetime limitations in the Tevatron proton-antiproton collider [1]. Electron lenses were originally proposed for compensation of electromagnetic long-range and head-on beam-beam interactions of proton and antiproton beams [2]. Results of successful employment of two electron lenses built and installed in the Tevatron are reported in [3,4,5]. In this paper we present design features of the Tevatron electron lenses (TELs), discuss the generation of electron beams, describe different modes of operation and outline the technical parameters of various subsystems.
△ Less
Submitted 11 August, 2008;
originally announced August 2008.
-
Fast beam stacking using RF barriers
Authors:
W. Chou,
D. Capista,
J. Griffin,
K-Y. Ng,
D. Wildman
Abstract:
Two barrier RF systems were fabricated, tested and installed in the Fermilab Main Injector. Each can provide 8 kV rectangular pulses (the RF barriers) at 90 kHz. When a stationary barrier is combined with a moving barrier, injected beams from the Booster can be continuously deflected, folded and stacked in the Main Injector, which leads to doubling of the beam intensity. This paper gives a repor…
▽ More
Two barrier RF systems were fabricated, tested and installed in the Fermilab Main Injector. Each can provide 8 kV rectangular pulses (the RF barriers) at 90 kHz. When a stationary barrier is combined with a moving barrier, injected beams from the Booster can be continuously deflected, folded and stacked in the Main Injector, which leads to doubling of the beam intensity. This paper gives a report on the beam experiment using this novel technology.
△ Less
Submitted 26 February, 2008;
originally announced February 2008.
-
Experimental Studies of Compensation of Beam-Beam Effects with Tevatron Electron Lenses
Authors:
V. Shiltsev,
Yu. Alexahin,
K. Bishofberger,
V. Kamerdzhiev,
V. Parkhomchuk,
V. Reva,
N. Solyak,
D. Wildman,
X. -L. Zhang,
F. Zimmermann
Abstract:
Applying the space-charge forces of a low-energy electron beam can lead to a significant improvement of the beam-particle lifetime limit arising from the beam-beam interaction in a high-energy collider [1]. In this article we present the results of various beam experiments with electron lenses, novel instruments developed for the beam-beam compensation at the Tevatron, which collides 980-GeV pro…
▽ More
Applying the space-charge forces of a low-energy electron beam can lead to a significant improvement of the beam-particle lifetime limit arising from the beam-beam interaction in a high-energy collider [1]. In this article we present the results of various beam experiments with electron lenses, novel instruments developed for the beam-beam compensation at the Tevatron, which collides 980-GeV proton and antiproton beams. We study the dependencies of the particle betatron tunes on the electron beam current, energy and position; we explore the effects of electron-beam imperfections and noises; and we quantify the improvements of the high-energy beam intensity and the collider luminosity lifetime obtained by the action of the Tevatron Electron Lenses.
△ Less
Submitted 4 February, 2008;
originally announced February 2008.