-
Study of the decay and production properties of $D_{s1}(2536)$ and $D_{s2}^*(2573)$
Authors:
M. Ablikim,
M. N. Achasov,
P. Adlarson,
O. Afedulidis,
X. C. Ai,
R. Aliberti,
A. Amoroso,
Q. An,
Y. Bai,
O. Bakina,
I. Balossino,
Y. Ban,
H. -R. Bao,
V. Batozskaya,
K. Begzsuren,
N. Berger,
M. Berlowski,
M. Bertani,
D. Bettoni,
F. Bianchi,
E. Bianco,
A. Bortone,
I. Boyko,
R. A. Briere,
A. Brueggemann
, et al. (645 additional authors not shown)
Abstract:
The $e^+e^-\rightarrow D_s^+D_{s1}(2536)^-$ and $e^+e^-\rightarrow D_s^+D^*_{s2}(2573)^-$ processes are studied using data samples collected with the BESIII detector at center-of-mass energies from 4.530 to 4.946~GeV. The absolute branching fractions of $D_{s1}(2536)^- \rightarrow \bar{D}^{*0}K^-$ and $D_{s2}^*(2573)^- \rightarrow \bar{D}^0K^-$ are measured for the first time to be…
▽ More
The $e^+e^-\rightarrow D_s^+D_{s1}(2536)^-$ and $e^+e^-\rightarrow D_s^+D^*_{s2}(2573)^-$ processes are studied using data samples collected with the BESIII detector at center-of-mass energies from 4.530 to 4.946~GeV. The absolute branching fractions of $D_{s1}(2536)^- \rightarrow \bar{D}^{*0}K^-$ and $D_{s2}^*(2573)^- \rightarrow \bar{D}^0K^-$ are measured for the first time to be $(35.9\pm 4.8\pm 3.5)\%$ and $(37.4\pm 3.1\pm 4.6)\%$, respectively. The measurements are in tension with predictions based on the assumption that the $D_{s1}(2536)$ and $D_{s2}^*(2573)$ are dominated by a bare $c\bar{s}$ component. The $e^+e^-\rightarrow D_s^+D_{s1}(2536)^-$ and $e^+e^-\rightarrow D_s^+D^*_{s2}(2573)^-$ cross sections are measured, and a resonant structure at around 4.6~GeV with a width of 50~MeV is observed for the first time with a statistical significance of $15σ$ in the $e^+e^-\rightarrow D_s^+D^*_{s2}(2573)^-$ process. It could be the $Y(4626)$ found by the Belle collaboration in the $D_s^+D_{s1}(2536)^{-}$ final state, since they have similar masses and widths. There is also evidence for a structure at around 4.75~GeV in both processes.
△ Less
Submitted 10 July, 2024;
originally announced July 2024.
-
Development of the front-end electronics for a cost-effective PET-like detector system
Authors:
Josephine Oppotsch,
Nadia Böhle,
Thomas Held,
Mario Fink,
Miriam Fritsch,
Fritz-Herbert Heinsius,
Matthias Steinke,
Ulrich Wiedner
Abstract:
Most detector systems used for positron emission particle tracking (PEPT) are very expensive due to the use of inorganic plastic scintillators combined with a high number of readout electronic channels. This work aims to reduce the overall cost of a PEPT-capable detector system by using large and cost-effective plastic scintillators and develo** custom 2 x 2 silicon photomultiplier (SiPM) arrays…
▽ More
Most detector systems used for positron emission particle tracking (PEPT) are very expensive due to the use of inorganic plastic scintillators combined with a high number of readout electronic channels. This work aims to reduce the overall cost of a PEPT-capable detector system by using large and cost-effective plastic scintillators and develo** custom 2 x 2 silicon photomultiplier (SiPM) arrays, preamplifiers, and discriminators. The use of long (20 mm x 20 mm x 1000 mm) plastic scintillator bars read out with photodetectors only at their respective ends allows an overall smaller number of photodetectors and associated readout electronics, which in turn reduces the overall cost of the system. In addition, the development of a custom SiPM array and preamplifier allows a free selection of interconnection and readout, as most commercial producers only offer specific types of interconnections and therefore lack other connections such as serial or hybrid. Thus, several common circuit types for SiPMs and preamplifiers were tested and compared in this work, and it was found that a serial connection implemented in a hybrid interconnection for the SiPMs and an inverting preamplifier based on a high-frequency operational amplifier provided the best results for the proposed detector system. Measured with a Na-22 source, the combination of SiPM array and preamplifier led to a rise time of 3.7 ns and a signal amplitude of 175 mV.
△ Less
Submitted 28 October, 2023; v1 submitted 30 June, 2023;
originally announced June 2023.
-
A simulation study on spatial and time resolution for a cost-effective positron emission particle tracking system
Authors:
Josephine Oppotsch,
Matthias Steinke,
Miriam Fritsch,
Fritz-Herbert Heinsius,
Thomas Held,
Nikoline Hilse,
Viktor Scherer,
Ulrich Wiedner
Abstract:
This work is the second part of a simulation study investigating the processing of densely packed and moving granular assemblies by positron emission particle tracking (PEPT). Since medical PET scanners commonly used for PEPT are very expensive, a PET-like detector system based on cost-effective organic plastic scintillator bars is being developed and tested for its capabilities. In this context,…
▽ More
This work is the second part of a simulation study investigating the processing of densely packed and moving granular assemblies by positron emission particle tracking (PEPT). Since medical PET scanners commonly used for PEPT are very expensive, a PET-like detector system based on cost-effective organic plastic scintillator bars is being developed and tested for its capabilities. In this context, the spatial resolution of a resting positron source, a source moving on a freely designed model path, and a particle motion given by a DEM (Discrete Element Method) simulation is studied using Monte Carlo simulations and the software toolkit Geant4. This not only extended the simulation and reconstruction to a moving source but also significantly improved the spatial resolution compared to previous work by adding oversampling and iteration to the reconstruction algorithm. Furthermore, in the case of a source following a trajectory developed from DEM simulations, a very good resolution of about 1 mm in all three directions and an average three-dimensional deviation between simulated and reconstructed events of 2.3 mm could be determined. Thus, the resolution for a realistic particle motion within the generic grate system (which is the test rig for further experimental studies) is well below the smallest particle size. The simulation of the dependence of the reconstruction accuracy on tracer particle location revealed a nearly constant efficiency within the entire detector system, which demonstrates that boundary effects can be neglected.
△ Less
Submitted 15 November, 2023; v1 submitted 30 June, 2023;
originally announced June 2023.
-
The new APD-Based Readout of the Crystal Barrel Calorimeter -- An Overview
Authors:
CBELSA/TAPS Collaboration,
:,
C. Honisch,
P. Klassen,
J. Müllers,
M. Urban,
F. Afzal,
J. Bieling,
S. Ciupka,
J. Hartmann,
P. Hoffmeister,
M. Lang,
D. Schaab,
C. Schmidt,
M. Steinacher,
D. Walther,
R. Beck,
K. -T. Brinkmann,
V. Crede,
H. Dutz,
D. Elsner,
W. Erni,
E. Fix,
F. Frommberger,
M. Grüner
, et al. (26 additional authors not shown)
Abstract:
The Crystal Barrel is an electromagnetic calorimeter consisting of 1380 CsI(Tl) scintillators, and is currently installed at the CBELSA/TAPS experiment where it is used to detect decay products from photoproduction of mesons. The readout of the Crystal Barrel has been upgraded in order to integrate the detector into the first level of the trigger and to increase its sensitivity for neutral final s…
▽ More
The Crystal Barrel is an electromagnetic calorimeter consisting of 1380 CsI(Tl) scintillators, and is currently installed at the CBELSA/TAPS experiment where it is used to detect decay products from photoproduction of mesons. The readout of the Crystal Barrel has been upgraded in order to integrate the detector into the first level of the trigger and to increase its sensitivity for neutral final states. The new readout uses avalanche photodiodes in the front-end and a dual back-end with branches optimized for energy and time measurement, respectively. An FPGA-based cluster finder processes the whole hit pattern within less than 100 ns. The important downside of APDs -- the temperature dependence of their gain -- is handled with a temperature stabilization and a compensating bias voltage supply. Additionally, a light pulser system allows the APDs' gains to be measured during beamtimes.
△ Less
Submitted 16 January, 2023; v1 submitted 23 December, 2022;
originally announced December 2022.
-
Technical Design Report for the PANDA Endcap Disc DIRC
Authors:
Panda Collaboration,
F. Davi,
W. Erni,
B. Krusche,
M. Steinacher,
N. Walford,
H. Liu,
Z. Liu,
B. Liu,
X. Shen,
C. Wang,
J. Zhao,
M. Albrecht,
T. Erlen,
F. Feldbauer,
M. Fink,
V. Freudenreich,
M. Fritsch,
F. H. Heinsius,
T. Held,
T. Holtmann,
I. Keshk,
H. Koch,
B. Kopf,
M. Kuhlmann
, et al. (441 additional authors not shown)
Abstract:
PANDA (anti-Proton ANnihiliation at DArmstadt) is planned to be one of the four main experiments at the future international accelerator complex FAIR (Facility for Antiproton and Ion Research) in Darmstadt, Germany. It is going to address fundamental questions of hadron physics and quantum chromodynamics using cooled antiproton beams with a high intensity and and momenta between 1.5 and 15 GeV/c.…
▽ More
PANDA (anti-Proton ANnihiliation at DArmstadt) is planned to be one of the four main experiments at the future international accelerator complex FAIR (Facility for Antiproton and Ion Research) in Darmstadt, Germany. It is going to address fundamental questions of hadron physics and quantum chromodynamics using cooled antiproton beams with a high intensity and and momenta between 1.5 and 15 GeV/c. PANDA is designed to reach a maximum luminosity of 2x10^32 cm^2 s. Most of the physics programs require an excellent particle identification (PID). The PID of hadronic states at the forward endcap of the target spectrometer will be done by a fast and compact Cherenkov detector that uses the detection of internally reflected Cherenkov light (DIRC) principle. It is designed to cover the polar angle range from 5° to 22° and to provide a separation power for the separation of charged pions and kaons up to 3 standard deviations (s.d.) for particle momenta up to 4 GeV/c in order to cover the important particle phase space. This document describes the technical design and the expected performance of the novel PANDA Disc DIRC detector that has not been used in any other high energy physics experiment (HEP) before. The performance has been studied with Monte-Carlo simulations and various beam tests at DESY and CERN. The final design meets all PANDA requirements and guarantees suffcient safety margins.
△ Less
Submitted 29 December, 2019;
originally announced December 2019.
-
Luminosity measurements for the R scan experiment at BESIII
Authors:
M. Ablikim,
M. N. Achasov,
S. Ahmed,
X. C. Ai,
O. Albayrak,
M. Albrecht,
D. J. Ambrose,
A. Amoroso,
F. F. An,
Q. An,
J. Z. Bai,
O. Bakina,
R. Baldini Ferroli,
Y. Ban,
D. W. Bennett,
J. V. Bennett,
N. Berger,
M. Bertani,
D. Bettoni,
J. M. Bian,
F. Bianchi,
E. Boger,
I. Boyko,
R. A. Briere,
H. Cai
, et al. (405 additional authors not shown)
Abstract:
By analyzing the large-angle Bhabha scattering events $e^{+}e^{-}$ $\to$ ($γ$)$e^{+}e^{-}$ and diphoton events $e^{+}e^{-}$ $\to$ $γγ$ for the data sets collected at center-of-mass (c.m.) energies between 2.2324 and 4.5900 GeV (131 energy points in total) with the upgraded Bei**g Spectrometer (BESIII) at the Bei**g Electron-Positron Collider (BEPCII), the integrated luminosities have been measur…
▽ More
By analyzing the large-angle Bhabha scattering events $e^{+}e^{-}$ $\to$ ($γ$)$e^{+}e^{-}$ and diphoton events $e^{+}e^{-}$ $\to$ $γγ$ for the data sets collected at center-of-mass (c.m.) energies between 2.2324 and 4.5900 GeV (131 energy points in total) with the upgraded Bei**g Spectrometer (BESIII) at the Bei**g Electron-Positron Collider (BEPCII), the integrated luminosities have been measured at the different c.m. energies, individually. The results are the important inputs for R value and $J/ψ$ resonance parameter measurements.
△ Less
Submitted 11 February, 2017;
originally announced February 2017.
-
Feasibility study for the measurement of $πN$ TDAs at PANDA in $\bar{p}p\to J/ψπ^0$
Authors:
PANDA Collaboration,
B. Singh,
W. Erni,
B. Krusche,
M. Steinacher,
N. Walford,
H. Liu,
Z. Liu,
B. Liu,
X. Shen,
C. Wang,
J. Zhao,
M. Albrecht,
T. Erlen,
M. Fink,
F. H. Heinsius,
T. Held,
T. Holtmann,
S. Jasper,
I. Keshk,
H. Koch,
B. Kopf,
M. Kuhlmann,
M. Kümmel,
S. Leiber
, et al. (488 additional authors not shown)
Abstract:
The exclusive charmonium production process in $\bar{p}p$ annihilation with an associated $π^0$ meson $\bar{p}p\to J/ψπ^0$ is studied in the framework of QCD collinear factorization. The feasibility of measuring this reaction through the $J/ψ\to e^+e^-$ decay channel with the PANDA (AntiProton ANnihilation at DArmstadt) experiment is investigated. Simulations on signal reconstruction efficiency as…
▽ More
The exclusive charmonium production process in $\bar{p}p$ annihilation with an associated $π^0$ meson $\bar{p}p\to J/ψπ^0$ is studied in the framework of QCD collinear factorization. The feasibility of measuring this reaction through the $J/ψ\to e^+e^-$ decay channel with the PANDA (AntiProton ANnihilation at DArmstadt) experiment is investigated. Simulations on signal reconstruction efficiency as well as the background rejection from various sources including the $\bar{p}p\toπ^+π^-π^0$ and $\bar{p}p\to J/ψπ^0π^0$ reactions are performed with PandaRoot, the simulation and analysis software framework of the PANDA experiment. It is shown that the measurement can be done at PANDA with significant constraining power under the assumption of an integrated luminosity attainable in four to five months of data taking at the maximum design luminosity.
△ Less
Submitted 7 October, 2016;
originally announced October 2016.
-
Measurements of Baryon Pair Decays of $χ_{cJ}$ Mesons
Authors:
M. Ablikim,
M. N. Achasov,
O. Albayrak,
D. J. Ambrose,
F. F. An,
Q. An,
J. Z. Bai,
Y. Ban,
J. Becker,
J. V. Bennett,
M. Bertani,
J. M. Bian,
E. Boger,
O. Bondarenko,
I. Boyko,
R. A. Briere,
V. Bytev,
X. Cai,
O. Cakir,
A. Calcaterra,
G. F. Cao,
S. A. Cetin,
J. F. Chang,
G. Chelkov,
G. Chen
, et al. (326 additional authors not shown)
Abstract:
Using 106 $\times 10^{6}$ $ψ^{\prime}$ decays collected with the BESIII detector at the BEPCII, three decays of $χ_{cJ}$ ($J=0,1,2$) with baryon pairs ($\llb$, $\ssb$, $\SSB$) in the final state have been studied. The branching fractions are measured to be $\cal{B}$$(χ_{c0,1,2}\rightarrowΛ\barΛ) =(33.3 \pm 2.0 \pm 2.6)\times 10^{-5}$, $(12.2 \pm 1.1 \pm 1.1)\times 10^{-5}$,…
▽ More
Using 106 $\times 10^{6}$ $ψ^{\prime}$ decays collected with the BESIII detector at the BEPCII, three decays of $χ_{cJ}$ ($J=0,1,2$) with baryon pairs ($\llb$, $\ssb$, $\SSB$) in the final state have been studied. The branching fractions are measured to be $\cal{B}$$(χ_{c0,1,2}\rightarrowΛ\barΛ) =(33.3 \pm 2.0 \pm 2.6)\times 10^{-5}$, $(12.2 \pm 1.1 \pm 1.1)\times 10^{-5}$, $(20.8 \pm 1.6 \pm 2.3)\times 10^{-5}$; $\cal{B}$$(χ_{c0,1,2}\rightarrowΣ^{0}\barΣ^{0})$ = $(47.8 \pm 3.4 \pm 3.9)\times 10^{-5}$, $(3.8 \pm 1.0 \pm 0.5)\times 10^{-5}$, $(4.0 \pm 1.1 \pm 0.5) \times 10^{-5}$; and $\cal{B}$$(χ_{c0,1,2}\rightarrowΣ^{+}\barΣ^{-})$ = $(45.4 \pm 4.2 \pm 3.0)\times 10^{-5}$, $(5.4 \pm 1.5 \pm 0.5)\times 10^{-5}$, $(4.9 \pm 1.9 \pm 0.7)\times 10^{-5}$, where the first error is statistical and the second is systematic. Upper limits on the branching fractions for the decays of $χ_{c1,2}\rightarrowΣ^{0}\barΣ^{0}$, $Σ^{+}\barΣ^{-}$, are estimated to be $\cal{B}$$(χ_{c1}\rightarrowΣ^{0}\barΣ^{0}) < 6.2\times 10^{-5}$, $\cal{B}$$(χ_{c2}\rightarrowΣ^{0}\barΣ^{0}) < 6.5\times 10^{-5}$, $\cal{B}$$(χ_{c1}\rightarrowΣ^{+}\barΣ^{-}) < 8.7\times 10^{-5}$ and $\cal{B}$$(χ_{c2}\rightarrowΣ^{+}\barΣ^{-}) < 8.8\times 10^{-5}$ at the 90% confidence level.
△ Less
Submitted 4 March, 2013; v1 submitted 9 November, 2012;
originally announced November 2012.
-
Technical Design Report for the: PANDA Micro Vertex Detector
Authors:
PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
Q. Wang,
H. Xu,
M. Albrecht,
J. Becker,
K. Eickel,
F. Feldbauer,
M. Fink,
P. Friedel,
F. H. Heinsius,
T. Held,
H. Koch,
B. Kopf,
M. Leyhe,
C. Motzko,
M. Pelizäus,
J. Pychy
, et al. (436 additional authors not shown)
Abstract:
This document illustrates the technical layout and the expected performance of the Micro Vertex Detector (MVD) of the PANDA experiment. The MVD will detect charged particles as close as possible to the interaction zone. Design criteria and the optimisation process as well as the technical solutions chosen are discussed and the results of this process are subjected to extensive Monte Carlo physics…
▽ More
This document illustrates the technical layout and the expected performance of the Micro Vertex Detector (MVD) of the PANDA experiment. The MVD will detect charged particles as close as possible to the interaction zone. Design criteria and the optimisation process as well as the technical solutions chosen are discussed and the results of this process are subjected to extensive Monte Carlo physics studies. The route towards realisation of the detector is outlined.
△ Less
Submitted 10 August, 2012; v1 submitted 27 July, 2012;
originally announced July 2012.
-
Technical Design Report for the: PANDA Straw Tube Tracker
Authors:
PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
Q. Wang,
H. Xu,
A. Aab,
M. Albrecht,
J. Becker,
A. Csapó,
F. Feldbauer,
M. Fink,
P. Friedel,
F. H. Heinsius,
T. Held,
L. Klask,
H. Koch,
B. Kopf,
S. Leiber,
M. Leyhe
, et al. (451 additional authors not shown)
Abstract:
This document describes the technical layout and the expected performance of the Straw Tube Tracker (STT), the main tracking detector of the PANDA target spectrometer. The STT encloses a Micro-Vertex-Detector (MVD) for the inner tracking and is followed in beam direction by a set of GEM-stations. The tasks of the STT are the measurement of the particle momentum from the reconstructed trajectory an…
▽ More
This document describes the technical layout and the expected performance of the Straw Tube Tracker (STT), the main tracking detector of the PANDA target spectrometer. The STT encloses a Micro-Vertex-Detector (MVD) for the inner tracking and is followed in beam direction by a set of GEM-stations. The tasks of the STT are the measurement of the particle momentum from the reconstructed trajectory and the measurement of the specific energy-loss for a particle identification. Dedicated simulations with full analysis studies of certain proton-antiproton reactions, identified as being benchmark tests for the whole PANDA scientific program, have been performed to test the STT layout and performance. The results are presented, and the time lines to construct the STT are described.
△ Less
Submitted 4 June, 2012; v1 submitted 24 May, 2012;
originally announced May 2012.
-
Technical Design Report for the PANDA Solenoid and Dipole Spectrometer Magnets
Authors:
The PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
O. Wang,
H. Xu,
J. Becker,
F. Feldbauer,
F. -H. Heinsius,
T. Held,
H. Koch,
B. Kopf,
M. Pelizaeus,
T. Schroeder,
M. Steinke,
U. Wiedner,
J. Zhong,
A. Bianconi,
M. Bragadireanu,
D. Pantea
, et al. (387 additional authors not shown)
Abstract:
This document is the Technical Design Report covering the two large spectrometer magnets of the PANDA detector set-up. It shows the conceptual design of the magnets and their anticipated performance. It precedes the tender and procurement of the magnets and, hence, is subject to possible modifications arising during this process.
This document is the Technical Design Report covering the two large spectrometer magnets of the PANDA detector set-up. It shows the conceptual design of the magnets and their anticipated performance. It precedes the tender and procurement of the magnets and, hence, is subject to possible modifications arising during this process.
△ Less
Submitted 1 July, 2009;
originally announced July 2009.
-
Technical Design Report for PANDA Electromagnetic Calorimeter (EMC)
Authors:
PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
O. Wang,
H. Xu,
J. Becker,
F. Feldbauer,
F. -H. Heinsius,
T. Held,
H. Koch,
B. Kopf,
M. Pelizaeus,
T. Schroeder,
M. Steinke,
U. Wiedner,
J. Zhong,
A. Bianconi,
M. Bragadireanu,
D. Pantea
, et al. (387 additional authors not shown)
Abstract:
This document presents the technical layout and the envisaged performance of the Electromagnetic Calorimeter (EMC) for the PANDA target spectrometer. The EMC has been designed to meet the physics goals of the PANDA experiment, which is being developed for the Facility for Antiproton and Ion Research (FAIR) at Darmstadt, Germany. The performance figures are based on extensive prototype tests and…
▽ More
This document presents the technical layout and the envisaged performance of the Electromagnetic Calorimeter (EMC) for the PANDA target spectrometer. The EMC has been designed to meet the physics goals of the PANDA experiment, which is being developed for the Facility for Antiproton and Ion Research (FAIR) at Darmstadt, Germany. The performance figures are based on extensive prototype tests and radiation hardness studies. The document shows that the EMC is ready for construction up to the front-end electronics interface.
△ Less
Submitted 7 October, 2008;
originally announced October 2008.
-
Tracked pellets - a way to improve the efficiency of charmonium studies
Authors:
O. Nordhage,
I. Lehmann,
J. Lith,
C. -J. Friden,
U. Wiedner
Abstract:
We investigate the possibility of tracking individual hydrogen micro-spheres from an internal pellet target. Such a method aims to provide the primary vertex of a reaction to within about 100 micrometres, without utilizing any detector response. Apart from background considerations the knowledge of the reaction vertex may be essential for the reconstruction of many physics channels. This is in p…
▽ More
We investigate the possibility of tracking individual hydrogen micro-spheres from an internal pellet target. Such a method aims to provide the primary vertex of a reaction to within about 100 micrometres, without utilizing any detector response. Apart from background considerations the knowledge of the reaction vertex may be essential for the reconstruction of many physics channels. This is in particular true for the study of the Psi(3770) decay into D-mesons planned at the PANDA detector at the future FAIR facility. Here, the reconstruction of displaced vertices is especially difficult since neutral particles are involved.
Studies with a pellet target at The Svedberg Laboratory, Uppsala, show the technical feasibility of a tracking system utilizing fast CCD line-scan cameras. Simulations for the reaction p-bar p to Psi(3770) to D+ D- prove the large impact such a system would have on the data taking and reconstruction at PANDA.
△ Less
Submitted 8 January, 2007;
originally announced January 2007.
-
Vacuum Predictions and Measurements for an Internal Pellet Target
Authors:
Inti Lehmann,
Orjan Nordhage,
Carl-Johan Friden,
Gunar Norman,
Curt Ekstrom,
Tord Johansson,
Ulrich Wiedner
Abstract:
Measurements with low Z targets at internal experiments typically imply a gas load which deteriorates the ring vacuum. Future experiments need reliable estimates for the expected vacuum conditions in order to design 4-pi detectors closely surrounding the interaction area.
We present a method for the calculation of the resulting vacuum of such a complex system using a Pellet Target. In order to…
▽ More
Measurements with low Z targets at internal experiments typically imply a gas load which deteriorates the ring vacuum. Future experiments need reliable estimates for the expected vacuum conditions in order to design 4-pi detectors closely surrounding the interaction area.
We present a method for the calculation of the resulting vacuum of such a complex system using a Pellet Target. In order to test the method, a vacuum system with diagnostic tools has been set up and a Pellet Target was operated under realistic conditions. The results for the absolute vacuum agree within factors of two with the expected pressures.
△ Less
Submitted 4 January, 2007;
originally announced January 2007.
-
On the behavior of micro-spheres in a hydrogen pellet target
Authors:
O. Nordhage,
Z. -K. Li,
C. -J. Friden,
G. Norman,
U. Wiedner
Abstract:
A pellet target produces micro-spheres of different materials, which are used as an internal target for nuclear and particle physics studies. We will describe the pellet hydrogen behavior by means of fluid dynamics and thermodynamics. In particular one aim is to theoretically understand the cooling effect in order to find an effective method to optimize the working conditions of a pellet target.…
▽ More
A pellet target produces micro-spheres of different materials, which are used as an internal target for nuclear and particle physics studies. We will describe the pellet hydrogen behavior by means of fluid dynamics and thermodynamics. In particular one aim is to theoretically understand the cooling effect in order to find an effective method to optimize the working conditions of a pellet target. During the droplet formation the evaporative cooling is best described by a multi-droplet diffusion-controlled model, while in vacuum, the evaporation follows the (revised) Hertz-Knudsen formula. Experimental observations compared with calculations clearly indicated the presence of supercooling, the effect of which is discussed as well.
△ Less
Submitted 8 March, 2005;
originally announced March 2005.