Rapid thermal emittance and quantum efficiency map** of a cesium telluride cathode in an rf photoinjector using multiple laser beamlets
Authors:
Lianmin Zheng,
Jiahang Shao,
Eric E. Wisniewski,
John G. Power,
Yingchao Du,
Wanming Liu,
Charles E. Whiteford,
Manoel Conde,
Scott Doran,
Chunguang **g,
Chuanxiang Tang
Abstract:
Thermal emittance and quantum efficiency (QE) are key figures of merit of photocathodes, and their uniformity is critical to high-performance photoinjectors. Several QE map** technologies have been successfully developed; however, there is still a dearth of information on thermal emittance maps. This is because of the extremely time-consuming procedure to gather measurements by scanning a small…
▽ More
Thermal emittance and quantum efficiency (QE) are key figures of merit of photocathodes, and their uniformity is critical to high-performance photoinjectors. Several QE map** technologies have been successfully developed; however, there is still a dearth of information on thermal emittance maps. This is because of the extremely time-consuming procedure to gather measurements by scanning a small beam across the cathode with fine steps. To simplify the map** procedure, and to reduce the time required to take measurements, we propose a new method that requires only a single scan of the solenoid current to simultaneously obtain thermal emittance and QE distribution by using a pattern beam with multiple beamlets. In this paper, its feasibility has been confirmed by both beam dynamics simulation and theoretical analysis. The method has been successfully demonstrated in a proof-of-principle experiment using an L-band radiofrequency photoinjector with a cesium telluride cathode. In the experiment, seven beamlets were generated from a microlens array system and their corresponding thermal emittance and QE varied from 0.93 to 1.14 $μ$m/mm and from 4.6 to 8.7%, respectively. We also discuss the limitations and future improvements of the method in this paper.
△ Less
Submitted 5 May, 2020; v1 submitted 19 June, 2019;
originally announced June 2019.
-
Experimental demonstration of the correction of coupled transverse dynamics aberration in an rf photoinjector
Authors:
Lianmin Zheng,
Jiahang Shao,
Yingchao Du,
John G. Power,
Eric E. Wisniewski,
Wanming Liu,
Charles E. Whiteford,
Manoel Conde,
Scott Doran,
Chunguang **g,
Chuanxiang Tang,
Wei Gai
Abstract:
The production of electron bunches with low transverse emittance approaches the thermal emittance of the photocathode as various aberrations are corrected. Recently, the coupled transverse dynamics aberration was theoretically identified as a significant source of emittance growth and a corrector magnet was proposed for its elimination [D.H. Dowell, F. Zhou, and J. Schmerge, PRAB 21, 010101 (2018)…
▽ More
The production of electron bunches with low transverse emittance approaches the thermal emittance of the photocathode as various aberrations are corrected. Recently, the coupled transverse dynamics aberration was theoretically identified as a significant source of emittance growth and a corrector magnet was proposed for its elimination [D.H. Dowell, F. Zhou, and J. Schmerge, PRAB 21, 010101 (2018)]. This aberration arises when the beam acquires an asymmetric distribution that is then rotated with respect to the transverse reference axis thus introducing a correlation in the vertical and horizontal planes. The asymmetry is introduced by a weak quadrupole field in the rf gun or emittance compensation solenoid and the rotation is caused by the solenoid. This Letter presents an experimental study of the coupled transverse dynamics aberration in an rf photoinjector and demonstrates its elimination by a quadrupole corrector consisting of a normal and a skew quadrupole. The experimental results agree well with theoretical predictions and numerical simulations. The study also demonstrates the emittance of a low charge beam can be preserved during transportation at its thermal value, which was 1.05 mm mrad/mm, for the cesium telluride photocathode and 248 nm UV laser used.
△ Less
Submitted 13 February, 2019;
originally announced February 2019.
-
Overestimation of thermal emittance in solenoid scans due to coupled transverse motion
Authors:
Lianmin Zheng,
Jiahang Shao,
Yingchao Du,
John G. Power,
Eric E. Wisniewski,
Wanming Liu,
Charles E. Whiteford,
Manoel Conde,
Scott Doran,
Chunguang **g,
Chuanxiang Tang,
Wei Gai
Abstract:
The solenoid scan is a widely used method for the in-situ measurement of the thermal emittance in a photocathode gun. The popularity of this method is due to its simplicity and convenience since all rf photocathode guns are equipped with an emittance compensation solenoid. This paper shows that the solenoid scan measurement overestimates the thermal emittance in the ordinary measurement configurat…
▽ More
The solenoid scan is a widely used method for the in-situ measurement of the thermal emittance in a photocathode gun. The popularity of this method is due to its simplicity and convenience since all rf photocathode guns are equipped with an emittance compensation solenoid. This paper shows that the solenoid scan measurement overestimates the thermal emittance in the ordinary measurement configuration due to a weak quadrupole field (present in either the rf gun or gun solenoid) followed by a rotation in the solenoid. This coupled transverse dynamics aberration introduces a correlation between the beam's horizontal and vertical motion leading to an increase in the measured 2D transverse emittance, thus the overestimation of the thermal emittance. This effect was systematically studied using both analytic expressions and numerical simulations. These studies were experimentally verified using an L-band 1.6-cell rf photocathode gun with a cesium telluride cathode, which shows a thermal emittance overestimation of 35% with a rms laser spot size of 2.7 mm. The paper concludes by showing that the accuracy of the solenoid scan can be improved by using a quadrupole magnet corrector, consisting of a pair of normal and skew quadrupole magnets.
△ Less
Submitted 25 December, 2018; v1 submitted 17 September, 2018;