-
Optimal Demodulation Domain for Microwave SQUID Multiplexers in Presence of Readout System Noise
Authors:
M. E. García Redondo,
N. A. Müller,
J. M. Salum,
L. P. Ferreyro,
J. D. Bonilla-Neira,
J. M. Geria,
J. J. Bonaparte,
T. Muscheid,
R. Gartmann,
A. Almela,
M. R. Hampel,
A. E. Fuster,
L. E. Ardila-Perez,
M. Wegner,
M. Platino,
O. Sander,
S. Kempf,
M. Weber
Abstract:
The Microwave SQUID Multiplexer (μMUX) is the device of choice for the readout of a large number of Low-Temperature Detectors in a wide variety of experiments within the fields of astronomy and particle physics. While it offers large multiplexing factors, the system noise performance is highly dependent on the cold and warm-readout electronic systems used to read it out, as well as the demodulatio…
▽ More
The Microwave SQUID Multiplexer (μMUX) is the device of choice for the readout of a large number of Low-Temperature Detectors in a wide variety of experiments within the fields of astronomy and particle physics. While it offers large multiplexing factors, the system noise performance is highly dependent on the cold and warm-readout electronic systems used to read it out, as well as the demodulation domain and parameters chosen. In order to understand the impact of the readout systems in the overall noise performance, first we extended the available μMUX simulation frameworks including additive and multiplicative noise sources in the probing tones (i.e. phase and amplitude noise), along with the capability of demodulating the scientific data, either in resonator's phase or amplitude. Then, considering the additive noise as a dominant noise source, the optimum readout parameters to achieve minimum system noise were found for both open-loop and flux-ramp demodulation schemes in the aforementioned domains. Later, we evaluated the system noise sensitivity to multiplicative noise sources under the optimum readout parameters. Finally, as a case study, we evaluated the optimal demodulation domain and expected system noise level for a typical Software-Defined Radio (SDR) readout system. This work leads to an improved system performance prediction and noise engineering based on the available readout electronics and selected demodulation domain.
△ Less
Submitted 10 June, 2024;
originally announced June 2024.
-
High precision measurement of the $^{99}$Tc $β$ spectrum
Authors:
Michael Paulsen,
Philipp Ranitzsch,
Martin Loidl,
Matias Rodrigues,
Karsten Kossert,
Xavier Mougeot,
Abilasha Singh,
Sylvain Leblond,
Jörn Beyer,
Lina Bockhorn,
Christian Enss,
Mathias Wegner,
Sebastian Kempf,
Ole Nähle
Abstract:
Highly precise measurements of the $^{99}$Tc beta spectrum were performed in two laboratories using metallic magnetic calorimeters. Independent sample preparations, evaluation methods and analyses yield consistent results and the spectrum could be measured down to less than 1 keV. Consistent beta spectra were also obtained via cross-evaluations of the experimental data sets. An additional independ…
▽ More
Highly precise measurements of the $^{99}$Tc beta spectrum were performed in two laboratories using metallic magnetic calorimeters. Independent sample preparations, evaluation methods and analyses yield consistent results and the spectrum could be measured down to less than 1 keV. Consistent beta spectra were also obtained via cross-evaluations of the experimental data sets. An additional independent measurement with silicon detectors in a $4π$ configuration confirms the spectrum shape above 25 keV. Detailed theoretical calculations were performed including nuclear structure and atomic effects. The spectrum shape was found to be sensitive to the effective value of the axial-vector coupling constant. Combining measurements and predictions, we extracted $Q_β=$295.82(16) keV and $g_A^{\text{eff}} = 1.530 (83)$. Furthermore, we derived the mean energy of the beta spectrum $\overline{E}_β$=98.45(20) keV, $\log f = -0.47660 (22)$ and $\log ft = 12.3478 (23)$.
△ Less
Submitted 4 October, 2023; v1 submitted 25 September, 2023;
originally announced September 2023.
-
Simultaneous MMC readout using a tailored μMUX based readout system
Authors:
Daniel Richter,
Mathias Wegner,
Felix Ahrens,
Christian Enss,
Nick Karcher,
Oliver Sander,
Constantin Schuster,
Marc Weber,
Thomas Wolber,
Sebastian Kempf
Abstract:
Magnetic microcalorimeters (MMCs) are cryogenic, energy-dispersive single-particle detectors providing excellent energy resolution, intrinsically fast signal rise time, quantum efficiency close to 100\%, large dynamic range as well as almost ideal linear response. One of the remaining challenges to be overcome to ultimately allow for the utilization of large-scale MMC based detector arrays with th…
▽ More
Magnetic microcalorimeters (MMCs) are cryogenic, energy-dispersive single-particle detectors providing excellent energy resolution, intrinsically fast signal rise time, quantum efficiency close to 100\%, large dynamic range as well as almost ideal linear response. One of the remaining challenges to be overcome to ultimately allow for the utilization of large-scale MMC based detector arrays with thousands to millions of individual pixels is the realization of a SQUID based multiplexing technique particularly tailored for MMC readout. Within this context, we report on the first truly multiplexed readout of an MMC based detector array using a frequency-division multiplexing approach realized by a custom microwave SQUID multiplexer based readout system.
△ Less
Submitted 27 March, 2023; v1 submitted 14 November, 2022;
originally announced November 2022.
-
Simulation framework for microwave SQUID multiplexer optimization
Authors:
Constantin Schuster,
Mathias Wegner,
Sebastian Kempf
Abstract:
So far, performance prediction and optimization of microwave SQUID multiplexers has largely been based on simple approximate analytical models and experimental results. This is caused by the complexity of the underlying physics and the intricacy of operation and readout parameters. As a simplified description can never account for all potential effects occurring in a real device, we have developed…
▽ More
So far, performance prediction and optimization of microwave SQUID multiplexers has largely been based on simple approximate analytical models and experimental results. This is caused by the complexity of the underlying physics and the intricacy of operation and readout parameters. As a simplified description can never account for all potential effects occurring in a real device, we have developed a software framework to simulate the characteristics and performance of a microwave SQUID multiplexer. Our simulation framework is a powerful tool to guide understanding and optimization of microwave SQUID multiplexers and other related devices. It includes common readout schemes such as open-loop or flux ramp modulated readout as well as the nonlinear behavior of Josephson tunnel junctions. Moreover, it accounts for the non-zero response time of superconducting microwave resonators with high loaded quality factors as well as the most significant noise contributions such as amplifier noise, resonator noise as well as SQUID noise. This ultimately leads to a prediction of device performance that is significantly better as compared simple analytical methods. Using the simulation framework, we discuss first steps towards a full microwave SQUID multiplexer optimization and highlight some other applications which our simulation framework can be used for.
△ Less
Submitted 10 January, 2023; v1 submitted 3 August, 2022;
originally announced August 2022.
-
Flux ramp modulation based hybrid microwave SQUID multiplexer
Authors:
Constantin Schuster,
Mathias Wegner,
Christian Enss,
Sebastian Kempf
Abstract:
We present a hybrid microwave SQUID multiplexer that combines two frequency-division multiplexing techniques to allow multiplexing a given number of cryogenic detectors with only a fraction of frequency encoding resonators. Similar to conventional microwave SQUID multiplexing, our multiplexer relies on inductively coupling non-hysteretic, unshunted rf-SQUIDs to superconducting microwave resonators…
▽ More
We present a hybrid microwave SQUID multiplexer that combines two frequency-division multiplexing techniques to allow multiplexing a given number of cryogenic detectors with only a fraction of frequency encoding resonators. Similar to conventional microwave SQUID multiplexing, our multiplexer relies on inductively coupling non-hysteretic, unshunted rf-SQUIDs to superconducting microwave resonators as well as applying flux ramp modulation for output signal linearization. However, instead of utilizing one resonator per SQUID, we couple multiple SQUIDs to a common readout resonator and encode the SQUID input signals in sidebands of the microwave carrier by varying the flux ramp modulation frequency for each SQUID. We prove the suitability of our approach using a prototype device and argue by means of fundamental information theory that our approach is particularly suited for reading out large cryogenic bolometer arrays.
△ Less
Submitted 11 February, 2022;
originally announced February 2022.
-
Analytical model of the readout power and SQUID hysteresis parameter dependence of the resonator characteristics of microwave SQUID multiplexers
Authors:
Mathias Wegner,
Christian Enss,
Sebastian Kempf
Abstract:
We report on the development of an analytical model describing the readout power and SQUID hysteresis parameter dependence of the resonator characteristics used for frequency encoding in microwave SQUID multiplexers. Within the context of this model, we derived the different dependencies by analyzing the Fourier components of the non-linear response of the non-hysteretic rf-SQUID. We show that our…
▽ More
We report on the development of an analytical model describing the readout power and SQUID hysteresis parameter dependence of the resonator characteristics used for frequency encoding in microwave SQUID multiplexers. Within the context of this model, we derived the different dependencies by analyzing the Fourier components of the non-linear response of the non-hysteretic rf-SQUID. We show that our model contains the existing model as a limiting case, leading to identical analytical expressions for small readout powers. Considering the approximations we made, our model is valid for rf-SQUID hysteresis parameters $β_{\mathrm{L}} < 0.6$ which fully covers the parameter range of existing multiplexer devices. We conclude our work with an experimental verification of the model. In particular, we demonstrate a very good agreement between measured multiplexer characteristics and predictions based on our model.
△ Less
Submitted 15 December, 2021;
originally announced December 2021.
-
Metallic magnetic calorimeter arrays for the first phase of the ECHo experiment
Authors:
F. Mantegazzini,
A. Barth,
H. Dorrer,
Ch. E. Düllmann,
C. Enss,
A. Fleischmann,
R. Hammann,
S. Kempf,
T. Kieck,
N. Kovac,
C. Velte,
M. Wegner,
K. Wendt,
T. Wickenhäuser,
L. Gastaldo
Abstract:
The ECHo experiment has been designed for the determination of the effective electron neutrino mass by means of the analysis of the end-point region of the Ho-163 electron capture spectrum. Metallic magnetic calorimeters enclosing Ho-163 are used for the high energy resolution calorimetric measurement of the Ho-163 spectrum. For the first phase of the experiment, ECHo-1k, a 72-pixel MMC array has…
▽ More
The ECHo experiment has been designed for the determination of the effective electron neutrino mass by means of the analysis of the end-point region of the Ho-163 electron capture spectrum. Metallic magnetic calorimeters enclosing Ho-163 are used for the high energy resolution calorimetric measurement of the Ho-163 spectrum. For the first phase of the experiment, ECHo-1k, a 72-pixel MMC array has been developed. The single-pixel design has been optimised to reach 100% stop** power for the radiation emitted in the Ho-163 electron capture process (besides the electron neutrino) and an energy resolution < 10 eV FWHM. We describe the design of the ECHo-1k detector chip, the fabrication steps and the characterisation at room temperature, at 4 K and at the final operation temperatures. In particular, a detailed analysis of the results from these tests allowed to define a quality check protocol based on parameters measurable at room temperature. We discuss the performance achieved with the two ECHo-1k detector chips - the first one with Ho-163 implanted in gold and the second one with Ho-163 implanted in silver - which have been used for the high statistics measurement of the ECHo-1k experiment. An average activity per pixel of 0.81 Bq and 0.71 Bq and an average energy resolution of 6.07 eV FWHM and 5.55 eV FWHM have been achieved with these two detectors, fulfilling the requirements for the first phase of the ECHo experiment.
△ Less
Submitted 18 November, 2021;
originally announced November 2021.
-
Multichannel read-out for arrays of metallic magnetic calorimeters
Authors:
F. Mantegazzini,
S. Allgeier,
A. Barth,
C. Enss,
A. Ferring-Siebert,
A. Fleischmann,
L. Gastaldo,
R. Hammann,
D. Hengstler,
S. Kempf,
D. Richter,
D. Schulz,
D. Unger,
C. Velte,
M. Wegner
Abstract:
Metallic magnetic micro-calorimeters (MMCs) operated at millikelvin temperature offer the possibility to achieve eV-scale energy resolution with high stop** power for X-rays and massive particles in an energy range up to several tens of keV. This motivates their use in a wide range of applications in fields as particle physics, atomic and molecular physics. Present detector systems consist of MM…
▽ More
Metallic magnetic micro-calorimeters (MMCs) operated at millikelvin temperature offer the possibility to achieve eV-scale energy resolution with high stop** power for X-rays and massive particles in an energy range up to several tens of keV. This motivates their use in a wide range of applications in fields as particle physics, atomic and molecular physics. Present detector systems consist of MMC arrays read out by 32 two-stage SQUID read-out channels. In contrast to the design of the detector array and consequently the design of the front-end SQUIDs, which need to be optimised for the physics case and the particles to be detected in a given experiment, the read-out chain can be standardised. We present our new standardised 32-channel parallel read-out for the operation of MMC arrays to be operated in a dilution refrigerator. The read-out system consists of a detector module, whose design depends on the particular application, an amplifier module, ribbon cables from room temperature to the millikelvin platform and a data acquisition system. In particular, we describe the realisation of the read-out system prepared for the ECHo-1k experiment for the operation of two 64-pixel arrays. The same read-out concept is also used for the maXs detector systems, developed for the study of the de-excitation of highly charged heavy ions by X-rays, as well as for the MOCCA system, developed for the energy and position sensitive detection of neutral molecular fragments for the study of fragmentation when molecular ions recombine with electrons. The choice of standard modular components for the operation of 32-channel MMC arrays offer the flexibility to upgrade detector modules without the need of any changes in the read-out system and the possibility to individually exchange parts in case of damages or failures.
△ Less
Submitted 13 October, 2021; v1 submitted 22 February, 2021;
originally announced February 2021.
-
Battery Detached Energy Conversion by Pyroelectric Effect
Authors:
Chenbo Zhang,
Yintao Song,
Maike Wegner,
Eckhard Quandt,
Xian Chen
Abstract:
We propose a pyroelectric energy conversion device that converts heat directly to electricity. In contrast to conventional pyroelectric energy conversion designs, this energy harvesting system is detached from any external power sources, operating only under periodically varying temperature. Such detachment unambiguously attributes the converted electricity to heat that drives the change of polari…
▽ More
We propose a pyroelectric energy conversion device that converts heat directly to electricity. In contrast to conventional pyroelectric energy conversion designs, this energy harvesting system is detached from any external power sources, operating only under periodically varying temperature. Such detachment unambiguously attributes the converted electricity to heat that drives the change of polarization in the pyroelectric material, not to the electric field alternation caused by the external battery. Using pure and Zr doped BaTiO$_3$, we demonstrate the electricity generation in consecutive temperature cycles. We further develop a thermodynamic model for the energy conversion system. Our model suggests that the work output is rate dependent: the work output per cycle is linearly dependent on the heat/cooling frequency below the predicted threshold. The linearity is confirmed by experiments, and the threshold frequency is derived by theory. Finally we propose a figure of merit that separates the materials intrinsic properties from the system design parameters. The figure of merit guides the future material development and device improvement. Our work clears out confusions and reforms the foundation for pyroelectric materials' resurgence as a competitor for green electricity.
△ Less
Submitted 11 February, 2019;
originally announced February 2019.
-
Software-defined Radio Readout System for the ECHo Experiment
Authors:
Oliver Sander,
Nick Karcher,
Oliver Krömer,
Marc Weber,
Sebastian Kempf,
Mathias Wegner,
Christian Enss
Abstract:
Metallic magnetic calorimeters (MMCs) are cryogenic detectors that offer an excellent energy resolution, a signal rise time of <100 ns, a high dynamic range and almost optimal linearity. MMCs are of high interest for many experiments. One of them, the ECHo experiment, requires the utilization of large MMC detector arrays. The readout of such MMC arrays is a challenging task, which can be tackled u…
▽ More
Metallic magnetic calorimeters (MMCs) are cryogenic detectors that offer an excellent energy resolution, a signal rise time of <100 ns, a high dynamic range and almost optimal linearity. MMCs are of high interest for many experiments. One of them, the ECHo experiment, requires the utilization of large MMC detector arrays. The readout of such MMC arrays is a challenging task, which can be tackled using software-defined radios (SDRs). Though SDR is a well-known approach in communications engineering, a dedicated implementation for frequency division multiplexed readout of MMCs is new and one of the technological key elements of the ECHo project. ECHo will be the first experiment to use microwave SQUID multiplexed MMC detectors and therefore pioneering the hardware, firmware and software development in this domain. This paper presents the detailed concepts and current status of the development.
△ Less
Submitted 24 June, 2018;
originally announced June 2018.
-
Maxent-Stress Optimization of 3D Biomolecular Models
Authors:
Michael Wegner,
Oskar Taubert,
Alexander Schug,
Henning Meyerhenke
Abstract:
Knowing a biomolecule's structure is inherently linked to and a prerequisite for any detailed understanding of its function. Significant effort has gone into develo** technologies for structural characterization. These technologies do not directly provide 3D structures; instead they typically yield noisy and erroneous distance information between specific entities such as atoms or residues, whic…
▽ More
Knowing a biomolecule's structure is inherently linked to and a prerequisite for any detailed understanding of its function. Significant effort has gone into develo** technologies for structural characterization. These technologies do not directly provide 3D structures; instead they typically yield noisy and erroneous distance information between specific entities such as atoms or residues, which have to be translated into consistent 3D models.
Here we present an approach for this translation process based on maxent-stress optimization. Our new approach extends the original graph drawing method for the new application's specifics by introducing additional constraints and confidence values as well as algorithmic components. Extensive experiments demonstrate that our approach infers structural models (i. e., sensible 3D coordinates for the molecule's atoms) that correspond well to the distance information, can handle noisy and error-prone data, and is considerably faster than established tools. Our results promise to allow domain scientists nearly-interactive structural modeling based on distance constraints.
△ Less
Submitted 21 June, 2017;
originally announced June 2017.
-
First Calorimetric Measurement of OI-line in the Electron Capture Spectrum of $^{163}$Ho
Authors:
P. C. -O. Ranitzsch,
C. Hassel,
M. Wegner,
S. Kempf,
A. Fleischmann,
C. Enss,
L. Gastaldo,
A. Herlert,
K. Johnston
Abstract:
The isotope $^{163}$Ho undergoes an electron capture process with a recommended value for the energy available to the decay, $Q_{\rm EC}$, of about 2.5 keV. According to the present knowledge, this is the lowest $Q_{\rm EC}$ value for electron capture processes. Because of that, $^{163}$Ho is the best candidate to perform experiments to investigate the value of the electron neutrino mass based on…
▽ More
The isotope $^{163}$Ho undergoes an electron capture process with a recommended value for the energy available to the decay, $Q_{\rm EC}$, of about 2.5 keV. According to the present knowledge, this is the lowest $Q_{\rm EC}$ value for electron capture processes. Because of that, $^{163}$Ho is the best candidate to perform experiments to investigate the value of the electron neutrino mass based on the analysis of the calorimetrically measured spectrum.
We present for the first time the calorimetric measurement of the atomic de-excitation of the $^{163}$Dy daughter atom upon the capture of an electron from the 5s shell in $^{163}$Ho, OI-line. The measured peak energy is 48 eV. This measurement was performed using low temperature metallic magnetic calorimeters with the $^{163}$Ho ion implanted in the absorber.
We demonstrate that the calorimetric spectrum of $^{163}$Ho can be measured with high precision and that the parameters describing the spectrum can be learned from the analysis of the data. Finally, we discuss the implications of this result for the Electron Capture $^{163}$Ho experiment, ECHo, aiming to reach sub-eV sensitivity on the electron neutrino mass by a high precision and high statistics calorimetric measurement of the $^{163}$Ho spectrum.
△ Less
Submitted 29 August, 2014;
originally announced September 2014.
-
The Electron Capture $^{163}$Ho Experiment ECHo: an overview
Authors:
L. Gastaldo,
K. Blaum,
A. Doerr,
Ch. E. Duellmann,
K. Eberhardt,
S. Eliseev,
C. Enss,
Amand Faessler,
A. Fleischmann,
S. Kempf,
M. Krivoruchenko,
S. Lahiri,
M. Maiti,
Yu. N. Novikov,
P. C. -O. Ranitzsch,
F. Simkovic,
Z. Szusc,
M. Wegner
Abstract:
The determination of the absolute scale of the neutrino masses is one of the most challenging present questions in particle physics. The most stringent limit, $m(\barν_{\mathrm{e}})<2$eV, was achieved for the electron anti-neutrino mass \cite{numass}. Different approaches are followed to achieve a sensitivity on neutrino masses in the sub-eV range. Among them, experiments exploring the beta decay…
▽ More
The determination of the absolute scale of the neutrino masses is one of the most challenging present questions in particle physics. The most stringent limit, $m(\barν_{\mathrm{e}})<2$eV, was achieved for the electron anti-neutrino mass \cite{numass}. Different approaches are followed to achieve a sensitivity on neutrino masses in the sub-eV range. Among them, experiments exploring the beta decay or electron capture of suitable nuclides can provide information on the electron neutrino mass value. We present the Electron Capture $^{163}$Ho experiment ECHo, which aims to investigate the electron neutrino mass in the sub-eV range by means of the analysis of the calorimetrically measured energy spectrum following electron capture of $^{163}$Ho. A high precision and high statistics spectrum will be measured with arrays of metallic magnetic calorimeters. We discuss some of the essential aspects of ECHo to reach the proposed sensitivity: detector optimization and performance, multiplexed readout, $^{163}$Ho source production and purification, as well as a precise theoretical and experimental parameterization of the calorimetric EC spectrum including in particular the value of $Q_{\mathrm{EC}}$. We present preliminary results obtained with a first prototype of single channel detectors as well as a first 64-pixel chip with integrated micro-wave SQUID multiplexer, which will already allow to investigate $m(ν_{\mathrm{e}})$ in the eV range.
△ Less
Submitted 20 September, 2013;
originally announced September 2013.
-
Multiplexed readout of MMC detector arrays using non-hysteretic rf-SQUIDs
Authors:
S. Kempf,
M. Wegner,
L. Gastaldo,
A. Fleischmann,
C. Enss
Abstract:
Metallic magnetic calorimeters (MMCs) are widely used for various experiments in fields ranging from atomic and nuclear physics to x-ray spectroscopy, laboratory astrophysics or material science. Whereas in previous experiments single pixel detectors or small arrays have been used, for future applications large arrays are needed. Therefore, suitable multiplexing techniques for MMC arrays are curre…
▽ More
Metallic magnetic calorimeters (MMCs) are widely used for various experiments in fields ranging from atomic and nuclear physics to x-ray spectroscopy, laboratory astrophysics or material science. Whereas in previous experiments single pixel detectors or small arrays have been used, for future applications large arrays are needed. Therefore, suitable multiplexing techniques for MMC arrays are currently under development. A promising approach for the readout of large arrays is the microwave SQUID multiplexer that operates in the frequency domain and that employs non-hysteretic rf-SQUIDs to transduce the detector signals into a frequency shift of high $Q$ resonators which can be monitored by using standard microwave measurement techniques. In this paper we discuss the design and the expected performance of a recently developed and fabricated 64 pixel detector array with integrated microwave SQUID multiplexer. First experimental data were obtained characterizing dc-SQUIDs with virtually identical washer design.
△ Less
Submitted 19 September, 2013;
originally announced September 2013.
-
The Electron Capture $^{163}$Ho Experiment ECHo
Authors:
K. Blaum,
A. Doerr,
C. E. Duellmann,
K. Eberhardt,
S. Eliseev,
C. Enss,
A. Faessler,
A. Fleischmann,
L. Gastaldo,
S. Kempf,
M. Krivoruchenko,
S. Lahiri,
M. Maiti,
Yu. N. Novikov,
P. C. -O. Ranitzsch,
F. Simkovic,
Z. Szusc,
M. Wegner
Abstract:
The determination of the absolute scale of the neutrino masses is one of the most challenging questions in particle physics. Different approaches are followed to achieve a sensitivity on neutrino masses in the sub-eV range. Among them, experiments exploring the beta decay and electron capture processes of suitable nuclides can provide necessary information on the electron neutrino mass value. In t…
▽ More
The determination of the absolute scale of the neutrino masses is one of the most challenging questions in particle physics. Different approaches are followed to achieve a sensitivity on neutrino masses in the sub-eV range. Among them, experiments exploring the beta decay and electron capture processes of suitable nuclides can provide necessary information on the electron neutrino mass value. In this talk we present the Electron Capture 163-Ho experiment ECHo, which aims to investigate the electron neutrino mass in the sub-eV range by means of the analysis of the calorimetrically measured energy spectrum following the electron capture process of 163-Ho. A high precision and high statistics spectrum will be measured by means of low temperature magnetic calorimeter arrays. We present preliminary results obtained with a first prototype of single channel detectors as well as the participating groups and their on-going developments.
△ Less
Submitted 11 June, 2013;
originally announced June 2013.