-
First Demonstration of a Combined Light and Charge Pixel Readout on the Anode Plane of a LArTPC
Authors:
N. Anfimov,
A. Branca,
J. Bürgi,
L. Calivers,
C. Cuesta,
R. Diurba,
P. Dunne,
D. A. Dwyer,
J. J. Evans,
A. C. Ezeribe,
A. Gauch,
I. Gil-Botella,
S. Greenberg,
D. Guffanti,
A. Karcher,
I. Kreslo,
J. Kunzmann,
N. Lane,
S. Manthey Corchado,
N. McConkey,
A. Navrer-Agasson,
S. Parsa,
G. Ruiz Ferreira,
B. Russell,
A. Selyunin
, et al. (8 additional authors not shown)
Abstract:
The novel SoLAr concept aims to extend sensitivities of liquid-argon neutrino detectors down to the MeV scale for next-generation detectors. SoLAr plans to accomplish this with a liquid-argon time projection chamber that employs an anode plane with dual charge and light readout, which enables precision matching of light and charge signals for data acquisition and reconstruction purposes. We presen…
▽ More
The novel SoLAr concept aims to extend sensitivities of liquid-argon neutrino detectors down to the MeV scale for next-generation detectors. SoLAr plans to accomplish this with a liquid-argon time projection chamber that employs an anode plane with dual charge and light readout, which enables precision matching of light and charge signals for data acquisition and reconstruction purposes. We present the results of a first demonstration of the SoLAr detector concept with a small-scale prototype detector integrating a pixel-based charge readout and silicon photomultipliers on a shared printed circuit board. We discuss the design of the prototype, and its operation and performance, highlighting the capability of such a detector design.
△ Less
Submitted 20 June, 2024;
originally announced June 2024.
-
Improving neutrino energy estimation of charged-current interaction events with recurrent neural networks in MicroBooNE
Authors:
MicroBooNE collaboration,
P. Abratenko,
O. Alterkait,
D. Andrade Aldana,
L. Arellano,
J. Asaadi,
A. Ashkenazi,
S. Balasubramanian,
B. Baller,
A. Barnard,
G. Barr,
D. Barrow,
J. Barrow,
V. Basque,
J. Bateman,
O. Benevides Rodrigues,
S. Berkman,
A. Bhanderi,
A. Bhat,
M. Bhattacharya,
M. Bishai,
A. Blake,
B. Bogart,
T. Bolton,
J. Y. Book
, et al. (164 additional authors not shown)
Abstract:
We present a deep learning-based method for estimating the neutrino energy of charged-current neutrino-argon interactions. We employ a recurrent neural network (RNN) architecture for neutrino energy estimation in the MicroBooNE experiment, utilizing liquid argon time projection chamber (LArTPC) detector technology. Traditional energy estimation approaches in LArTPCs, which largely rely on reconstr…
▽ More
We present a deep learning-based method for estimating the neutrino energy of charged-current neutrino-argon interactions. We employ a recurrent neural network (RNN) architecture for neutrino energy estimation in the MicroBooNE experiment, utilizing liquid argon time projection chamber (LArTPC) detector technology. Traditional energy estimation approaches in LArTPCs, which largely rely on reconstructing and summing visible energies, often experience sizable biases and resolution smearing because of the complex nature of neutrino interactions and the detector response. The estimation of neutrino energy can be improved after considering the kinematics information of reconstructed final-state particles. Utilizing kinematic information of reconstructed particles, the deep learning-based approach shows improved resolution and reduced bias for the muon neutrino Monte Carlo simulation sample compared to the traditional approach. In order to address the common concern about the effectiveness of this method on experimental data, the RNN-based energy estimator is further examined and validated with dedicated data-simulation consistency tests using MicroBooNE data. We also assess its potential impact on a neutrino oscillation study after accounting for all statistical and systematic uncertainties and show that it enhances physics sensitivity. This method has good potential to improve the performance of other physics analyses.
△ Less
Submitted 14 June, 2024;
originally announced June 2024.
-
Scintillation Light in SBND: Simulation, Reconstruction, and Expected Performance of the Photon Detection System
Authors:
SBND Collaboration,
P. Abratenko,
R. Acciarri,
C. Adams,
L. Aliaga-Soplin,
O. Alterkait,
R. Alvarez-Garrote,
C. Andreopoulos,
A. Antonakis,
L. Arellano,
J. Asaadi,
W. Badgett,
S. Balasubramanian,
V. Basque,
A. Beever,
B. Behera,
E. Belchior,
M. Betancourt,
A. Bhat,
M. Bishai,
A. Blake,
B. Bogart,
J. Bogenschuetz,
D. Brailsford,
A. Brandt
, et al. (158 additional authors not shown)
Abstract:
SBND is the near detector of the Short-Baseline Neutrino program at Fermilab. Its location near to the Booster Neutrino Beam source and relatively large mass will allow the study of neutrino interactions on argon with unprecedented statistics. This paper describes the expected performance of the SBND photon detection system, using a simulated sample of beam neutrinos and cosmogenic particles. Its…
▽ More
SBND is the near detector of the Short-Baseline Neutrino program at Fermilab. Its location near to the Booster Neutrino Beam source and relatively large mass will allow the study of neutrino interactions on argon with unprecedented statistics. This paper describes the expected performance of the SBND photon detection system, using a simulated sample of beam neutrinos and cosmogenic particles. Its design is a dual readout concept combining a system of 120 photomultiplier tubes, used for triggering, with a system of 192 X-ARAPUCA devices, located behind the anode wire planes. Furthermore, covering the cathode plane with highly-reflective panels coated with a wavelength-shifting compound recovers part of the light emitted towards the cathode, where no optical detectors exist. We show how this new design provides a high light yield and a more uniform detection efficiency, an excellent timing resolution and an independent 3D-position reconstruction using only the scintillation light. Finally, the whole reconstruction chain is applied to recover the temporal structure of the beam spill, which is resolved with a resolution on the order of nanoseconds.
△ Less
Submitted 11 June, 2024;
originally announced June 2024.
-
Optimal Demodulation Domain for Microwave SQUID Multiplexers in Presence of Readout System Noise
Authors:
M. E. García Redondo,
N. A. Müller,
J. M. Salum,
L. P. Ferreyro,
J. D. Bonilla-Neira,
J. M. Geria,
J. J. Bonaparte,
T. Muscheid,
R. Gartmann,
A. Almela,
M. R. Hampel,
A. E. Fuster,
L. E. Ardila-Perez,
M. Wegner,
M. Platino,
O. Sander,
S. Kempf,
M. Weber
Abstract:
The Microwave SQUID Multiplexer (μMUX) is the device of choice for the readout of a large number of Low-Temperature Detectors in a wide variety of experiments within the fields of astronomy and particle physics. While it offers large multiplexing factors, the system noise performance is highly dependent on the cold and warm-readout electronic systems used to read it out, as well as the demodulatio…
▽ More
The Microwave SQUID Multiplexer (μMUX) is the device of choice for the readout of a large number of Low-Temperature Detectors in a wide variety of experiments within the fields of astronomy and particle physics. While it offers large multiplexing factors, the system noise performance is highly dependent on the cold and warm-readout electronic systems used to read it out, as well as the demodulation domain and parameters chosen. In order to understand the impact of the readout systems in the overall noise performance, first we extended the available μMUX simulation frameworks including additive and multiplicative noise sources in the probing tones (i.e. phase and amplitude noise), along with the capability of demodulating the scientific data, either in resonator's phase or amplitude. Then, considering the additive noise as a dominant noise source, the optimum readout parameters to achieve minimum system noise were found for both open-loop and flux-ramp demodulation schemes in the aforementioned domains. Later, we evaluated the system noise sensitivity to multiplicative noise sources under the optimum readout parameters. Finally, as a case study, we evaluated the optimal demodulation domain and expected system noise level for a typical Software-Defined Radio (SDR) readout system. This work leads to an improved system performance prediction and noise engineering based on the available readout electronics and selected demodulation domain.
△ Less
Submitted 10 June, 2024;
originally announced June 2024.
-
Ferroelectrically-enhanced Schottky barrier transistors for Logic-in-Memory applications
Authors:
Daniele Nazzari,
Lukas Wind,
Masiar Sistani,
Dominik Mayr,
Kihye Kim,
Walter M. Weber
Abstract:
Artificial neural networks (ANNs) have had an enormous impact on a multitude of sectors, from research to industry, generating an unprecedented demand for tailor-suited hardware platforms. Their training and execution is highly memory-intensive, clearly evidencing the limitations affecting the currently available hardware based on the von Neumann architecture, which requires frequent data shuttlin…
▽ More
Artificial neural networks (ANNs) have had an enormous impact on a multitude of sectors, from research to industry, generating an unprecedented demand for tailor-suited hardware platforms. Their training and execution is highly memory-intensive, clearly evidencing the limitations affecting the currently available hardware based on the von Neumann architecture, which requires frequent data shuttling due to the physical separation of logic and memory units. This does not only limit the achievable performances but also greatly increases the energy consumption, hindering the integration of ANNs into low-power platforms. New Logic in Memory (LiM) architectures, able to unify memory and logic functionalities into a single component, are highly promising for overcoming these limitations, by drastically reducing the need of data transfers. Recently, it has been shown that a very flexible platform for logic applications can be realized recurring to a multi-gated Schottky-Barrier Field Effect Transistor (SBFET). If equipped with memory capabilities, this architecture could represent an ideal building block for versatile LiM hardware. To reach this goal, here we investigate the integration of a ferroelectric Hf$_{0.5}$Zr$_{0.5}$O$_2$ (HZO) layer onto Dual Top Gated SBFETs. We demonstrate that HZO polarization charges can be successfully employed to tune the height of the two Schottky barriers, influencing the injection behavior, thus defining the transistor mode, switching it between n and p-type transport. The modulation strength is strongly dependent on the polarization pulse height, allowing for the selection of multiple current levels. All these achievable states can be well retained over time, thanks to the HZO stability. The presented result show how ferroelectric-enhanced SBFETs are promising for the realization of novel LiM hardware, enabling low-power circuits for ANNs execution.
△ Less
Submitted 30 April, 2024;
originally announced April 2024.
-
Capturing the Macroscopic Behaviour of Molecular Dynamics with Membership Functions
Authors:
Alexander Sikorski,
Robert Julian Rabben,
Surahit Chewle,
Marcus Weber
Abstract:
Markov processes serve as foundational models in many scientific disciplines, such as molecular dynamics, and their simulation forms a common basis for analysis. While simulations produce useful trajectories, obtaining macroscopic information directly from microstate data presents significant challenges. This paper addresses this gap by introducing the concept of membership functions being the mac…
▽ More
Markov processes serve as foundational models in many scientific disciplines, such as molecular dynamics, and their simulation forms a common basis for analysis. While simulations produce useful trajectories, obtaining macroscopic information directly from microstate data presents significant challenges. This paper addresses this gap by introducing the concept of membership functions being the macrostates themselves. We derive equations for the holding times of these macrostates and demonstrate their consistency with the classical definition. Furthermore, we discuss the application of the ISOKANN method for learning these quantities from simulation data. In addition, we present a novel method for extracting transition paths from simulations based on the ISOKANN results and demonstrate its efficacy by applying it to simulations of the μ-opioid receptor. With this approach we provide a new perspective on the analysis of macroscopic behaviour of Markov systems.
△ Less
Submitted 10 June, 2024; v1 submitted 16 April, 2024;
originally announced April 2024.
-
Measurement of the differential cross section for neutral pion production in charged-current muon neutrino interactions on argon with the MicroBooNE detector
Authors:
MicroBooNE collaboration,
P. Abratenko,
O. Alterkait,
D. Andrade Aldana,
L. Arellano,
J. Asaadi,
A. Ashkenazi,
S. Balasubramanian,
B. Baller,
G. Barr,
D. Barrow,
J. Barrow,
V. Basque,
O. Benevides Rodrigues,
S. Berkman,
A. Bhanderi,
A. Bhat,
M. Bhattacharya,
M. Bishai,
A. Blake,
B. Bogart,
T. Bolton,
J. Y. Book,
M. B. Brunetti,
L. Camilleri
, et al. (163 additional authors not shown)
Abstract:
We present a measurement of neutral pion production in charged-current interactions using data recorded with the MicroBooNE detector exposed to Fermilab's booster neutrino beam. The signal comprises one muon, one neutral pion, any number of nucleons, and no charged pions. Studying neutral pion production in the MicroBooNE detector provides an opportunity to better understand neutrino-argon interac…
▽ More
We present a measurement of neutral pion production in charged-current interactions using data recorded with the MicroBooNE detector exposed to Fermilab's booster neutrino beam. The signal comprises one muon, one neutral pion, any number of nucleons, and no charged pions. Studying neutral pion production in the MicroBooNE detector provides an opportunity to better understand neutrino-argon interactions, and is crucial for future accelerator-based neutrino oscillation experiments. Using a dataset corresponding to $6.86 \times 10^{20}$ protons on target, we present single-differential cross sections in muon and neutral pion momenta, scattering angles with respect to the beam for the outgoing muon and neutral pion, as well as the opening angle between the muon and neutral pion. Data extracted cross sections are compared to generator predictions. We report good agreement between the data and the models for scattering angles, except for an over-prediction by generators at muon forward angles. Similarly, the agreement between data and the models as a function of momentum is good, except for an underprediction by generators in the medium momentum ranges, $200-400$ MeV for muons and $100-200$ MeV for pions.
△ Less
Submitted 6 May, 2024; v1 submitted 15 April, 2024;
originally announced April 2024.
-
Performance of a modular ton-scale pixel-readout liquid argon time projection chamber
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
T. Alves,
H. Amar,
P. Amedo,
J. Anderson,
D. A. Andrade
, et al. (1340 additional authors not shown)
Abstract:
The Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmi…
▽ More
The Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmic ray events collected in the spring of 2021. We use this sample to demonstrate the imaging performance of the charge and light readout systems as well as the signal correlations between the two. We also report argon purity and detector uniformity measurements, and provide comparisons to detector simulations.
△ Less
Submitted 5 March, 2024;
originally announced March 2024.
-
Do** Liquid Argon with Xenon in ProtoDUNE Single-Phase: Effects on Scintillation Light
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
H. Amar Es-sghir,
P. Amedo,
J. Anderson,
D. A. Andrade,
C. Andreopoulos
, et al. (1300 additional authors not shown)
Abstract:
Do** of liquid argon TPCs (LArTPCs) with a small concentration of xenon is a technique for light-shifting and facilitates the detection of the liquid argon scintillation light. In this paper, we present the results of the first do** test ever performed in a kiloton-scale LArTPC. From February to May 2020, we carried out this special run in the single-phase DUNE Far Detector prototype (ProtoDUN…
▽ More
Do** of liquid argon TPCs (LArTPCs) with a small concentration of xenon is a technique for light-shifting and facilitates the detection of the liquid argon scintillation light. In this paper, we present the results of the first do** test ever performed in a kiloton-scale LArTPC. From February to May 2020, we carried out this special run in the single-phase DUNE Far Detector prototype (ProtoDUNE-SP) at CERN, featuring 770 t of total liquid argon mass with 410 t of fiducial mass. The goal of the run was to measure the light and charge response of the detector to the addition of xenon, up to a concentration of 18.8 ppm. The main purpose was to test the possibility for reduction of non-uniformities in light collection, caused by deployment of photon detectors only within the anode planes. Light collection was analysed as a function of the xenon concentration, by using the pre-existing photon detection system (PDS) of ProtoDUNE-SP and an additional smaller set-up installed specifically for this run. In this paper we first summarize our current understanding of the argon-xenon energy transfer process and the impact of the presence of nitrogen in argon with and without xenon dopant. We then describe the key elements of ProtoDUNE-SP and the injection method deployed. Two dedicated photon detectors were able to collect the light produced by xenon and the total light. The ratio of these components was measured to be about 0.65 as 18.8 ppm of xenon were injected. We performed studies of the collection efficiency as a function of the distance between tracks and light detectors, demonstrating enhanced uniformity of response for the anode-mounted PDS. We also show that xenon do** can substantially recover light losses due to contamination of the liquid argon by nitrogen.
△ Less
Submitted 9 February, 2024; v1 submitted 2 February, 2024;
originally announced February 2024.
-
The Kramers turnover in terms of a macro-state projection on phase space
Authors:
Luca Donati,
Christof Schutte,
Marcus Weber
Abstract:
We have investigated how Langevin dynamics is affected by the friction coefficient using the novel algorithm ISOKANN, which combines the transfer operator approach with modern machine learning techniques. ISOKANN describes the dynamics in terms of an invariant subspace projection of the Koopman operator defined in the entire state space, avoiding approximations due to dimensionality reduction and…
▽ More
We have investigated how Langevin dynamics is affected by the friction coefficient using the novel algorithm ISOKANN, which combines the transfer operator approach with modern machine learning techniques. ISOKANN describes the dynamics in terms of an invariant subspace projection of the Koopman operator defined in the entire state space, avoiding approximations due to dimensionality reduction and discretization. Our results are consistent with the Kramers turnover and show that in the low and moderate friction regimes, metastable macro-states and transition rates are defined in phase space, not only in position space.
△ Less
Submitted 10 May, 2024; v1 submitted 31 January, 2024;
originally announced February 2024.
-
The DUNE Far Detector Vertical Drift Technology, Technical Design Report
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
H. Amar,
P. Amedo,
J. Anderson,
D. A. Andrade,
C. Andreopoulos
, et al. (1304 additional authors not shown)
Abstract:
DUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on a near and a far detector as it aims to determine the neutrino mass hierarchy and to make high-precisi…
▽ More
DUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on a near and a far detector as it aims to determine the neutrino mass hierarchy and to make high-precision measurements of the PMNS matrix parameters, including the CP-violating phase. It will also stand ready to observe supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model.
The DUNE far detector implements liquid argon time-projection chamber (LArTPC) technology, and combines the many tens-of-kiloton fiducial mass necessary for rare event searches with the sub-centimeter spatial resolution required to image those events with high precision. The addition of a photon detection system enhances physics capabilities for all DUNE physics drivers and opens prospects for further physics explorations. Given its size, the far detector will be implemented as a set of modules, with LArTPC designs that differ from one another as newer technologies arise.
In the vertical drift LArTPC design, a horizontal cathode bisects the detector, creating two stacked drift volumes in which ionization charges drift towards anodes at either the top or bottom. The anodes are composed of perforated PCB layers with conductive strips, enabling reconstruction in 3D. Light-trap-style photon detection modules are placed both on the cryostat's side walls and on the central cathode where they are optically powered.
This Technical Design Report describes in detail the technical implementations of each subsystem of this LArTPC that, together with the other far detector modules and the near detector, will enable DUNE to achieve its physics goals.
△ Less
Submitted 5 December, 2023;
originally announced December 2023.
-
Tensor-SqRA: Modeling the Transition Rates of Interacting Molecular Systems in terms of Potential Energies
Authors:
Alexander Sikorski,
Amir Niknejad,
Marcus Weber,
Luca Donati
Abstract:
Estimating the rate of rare conformational changes in molecular systems is one of the goals of Molecular Dynamics simulations. In the past decades, a lot of progress has been done in data-based approaches towards this problem. In contrast, model-based methods such as the Square Root Approximation (SqRA), directly derive these quantities from the potential energy functions. In this article we demon…
▽ More
Estimating the rate of rare conformational changes in molecular systems is one of the goals of Molecular Dynamics simulations. In the past decades, a lot of progress has been done in data-based approaches towards this problem. In contrast, model-based methods such as the Square Root Approximation (SqRA), directly derive these quantities from the potential energy functions. In this article we demonstrate how the SqRA formalism naturally blends with the tensor structure obtained by coupling multiple systems, resulting in the tensor-based Square Root Approximation (tSqRA). It enables efficient treatment of high-dimensional systems using the SqRA and provides an algebraic expression of the impact of coupling energies between molecular subsystems. Based on the tSqRA, we also develop the Projected Rate Estimation (PRE), a hybrid data-model-based algorithm that efficiently estimates the slowest rates for coupled systems. In addition, we investigate the possibility of integrating low-rank approximations within this framework to maximize the potential of the tSqRA.
△ Less
Submitted 16 November, 2023;
originally announced November 2023.
-
RFSoC Gen3-Based Software-Defined Radio Characterization for the Readout System of Low-Temperature Bolometers
Authors:
M. E. García Redondo,
T. Muscheid,
R. Gartmann,
J. M. Salum,
L. P. Ferreyro,
N. A. Müller,
J. D. Bonilla-Neira,
J. M. Geria,
J. J. Bonaparte,
A. Almela,
L. E. Ardila-Perez,
M. R. Hampel,
A. E. Fuster,
M. Platino,
O. Sander,
M. Weber,
A. Etchegoyen
Abstract:
This work reports the performance evaluation of an SDR readout system based on the latest generation (Gen3) of the AMD's Radio Frequency System-on-Chip (RFSoC) processing platform, which integrates a full-stack processing system and a powerful FPGA with up to 32 high-speed and high-resolution 14-bit Digital-to-Analog Converters (DACs) and Analog-to-Digital Converters (ADCs). The proposed readout s…
▽ More
This work reports the performance evaluation of an SDR readout system based on the latest generation (Gen3) of the AMD's Radio Frequency System-on-Chip (RFSoC) processing platform, which integrates a full-stack processing system and a powerful FPGA with up to 32 high-speed and high-resolution 14-bit Digital-to-Analog Converters (DACs) and Analog-to-Digital Converters (ADCs). The proposed readout system uses a previously developed multi-band, double-conversion IQ RF-mixing board targeting a multiplexing factor of approximately 1,000 bolometers in a bandwidth between 4 and 8 GHz, in line with state-of-the-art microwave SQUID multiplexers ($μ$MUX). The characterization of the system was performed in two stages, under the conditions typically imposed by the multiplexer and the cold readout circuit. First, in transmission, showing that noise and spurious levels of the generated tones are close to the values imposed by the cold readout. Second, in RF loopback, presenting noise values better than -100 dBc/Hz totally in agreement with the state-of-the-art readout systems. It was demonstrated that the RFSoC Gen3 device is a suitable enabling technology for the next generation of superconducting detector readout systems, reducing system complexity, increasing system integration, and achieving these goals without performance degradation.
△ Less
Submitted 8 May, 2024; v1 submitted 6 November, 2023;
originally announced November 2023.
-
Search for heavy neutral leptons in electron-positron and neutral-pion final states with the MicroBooNE detector
Authors:
MicroBooNE collaboration,
P. Abratenko,
O. Alterkait,
D. Andrade Aldana,
L. Arellano,
J. Asaadi,
A. Ashkenazi,
S. Balasubramanian,
B. Baller,
G. Barr,
D. Barrow,
J. Barrow,
V. Basque,
O. Benevides Rodrigues,
S. Berkman,
A. Bhanderi,
A. Bhat,
M. Bhattacharya,
M. Bishai,
A. Blake,
B. Bogart,
T. Bolton,
J. Y. Book,
M. B. Brunetti,
L. Camilleri
, et al. (163 additional authors not shown)
Abstract:
We present the first search for heavy neutral leptons (HNL) decaying into $νe^+e^-$ or $νπ^0$ final states in a liquid-argon time projection chamber using data collected with the MicroBooNE detector. The data were recorded synchronously with the NuMI neutrino beam from Fermilab's Main Injector corresponding to a total exposure of $7.01 \times 10^{20}$ protons on target. We set upper limits at the…
▽ More
We present the first search for heavy neutral leptons (HNL) decaying into $νe^+e^-$ or $νπ^0$ final states in a liquid-argon time projection chamber using data collected with the MicroBooNE detector. The data were recorded synchronously with the NuMI neutrino beam from Fermilab's Main Injector corresponding to a total exposure of $7.01 \times 10^{20}$ protons on target. We set upper limits at the $90\%$ confidence level on the mixing parameter $\lvert U_{μ4}\rvert^2$ in the mass ranges $10\le m_{\rm HNL}\le 150$ MeV for the $νe^+e^-$ channel and $150\le m_{\rm HNL}\le 245$ MeV for the $νπ^0$ channel, assuming $\lvert U_{e 4}\rvert^2 = \lvert U_{τ4}\rvert^2 = 0$. These limits represent the most stringent constraints in the mass range $35<m_{\rm HNL}<175$ MeV and the first constraints from a direct search for $νπ^0$ decays.
△ Less
Submitted 12 January, 2024; v1 submitted 11 October, 2023;
originally announced October 2023.
-
Measurement of triple-differential inclusive muon-neutrino charged-current cross section on argon with the MicroBooNE detector
Authors:
MicroBooNE Collaboration,
P. Abratenko,
O. Alterkait,
D. Andrade Aldana,
L. Arellano,
J. Asaadi,
A. Ashkenazi,
S. Balasubramanian,
B. Baller,
G. Barr,
D. Barrow,
J. Barrow,
V. Basque,
O. Benevides Rodrigues,
S. Berkman,
A. Bhanderi,
A. Bhat,
M. Bhattacharya,
M. Bishai,
A. Blake,
B. Bogart,
T. Bolton,
J. Y. Book,
L. Camilleri,
Y. Cao
, et al. (165 additional authors not shown)
Abstract:
We report the first measurement of the differential cross section $d^{2}σ(E_ν)/ d\cos(θ_μ) dP_μ$ for inclusive muon-neutrino charged-current scattering on argon. This measurement utilizes data from 6.4$\times10^{20}$ protons on target of exposure collected using the MicroBooNE liquid argon time projection chamber located along the Fermilab Booster Neutrino Beam with a mean neutrino energy of appro…
▽ More
We report the first measurement of the differential cross section $d^{2}σ(E_ν)/ d\cos(θ_μ) dP_μ$ for inclusive muon-neutrino charged-current scattering on argon. This measurement utilizes data from 6.4$\times10^{20}$ protons on target of exposure collected using the MicroBooNE liquid argon time projection chamber located along the Fermilab Booster Neutrino Beam with a mean neutrino energy of approximately 0.8~GeV. The map** from reconstructed kinematics to truth quantities, particularly from reconstructed to true neutrino energy, is validated by comparing the distribution of reconstructed hadronic energy in data to that of the model prediction in different muon scattering angle bins after conditional constraint from the muon momentum distribution in data. The success of this validation gives confidence that the missing energy in the MicroBooNE detector is well-modeled in simulation, enabling the unfolding to a triple-differential measurement over muon momentum, muon scattering angle, and neutrino energy. The unfolded measurement covers an extensive phase space, providing a wealth of information useful for future liquid argon time projection chamber experiments measuring neutrino oscillations. Comparisons against a number of commonly used model predictions are included and their performance in different parts of the available phase-space is discussed.
△ Less
Submitted 10 December, 2023; v1 submitted 12 July, 2023;
originally announced July 2023.
-
Efficient Estimation of Transition Rates as Functions of pH
Authors:
Luca Donati,
Marcus Weber
Abstract:
Extracting the kinetic properties of a system whose dynamics depend on the pH of the environment with which it exchanges energy and atoms requires sampling the Grand Canonical Ensemble. As an alternative, we present a novel strategy that requires simulating only the most recurrent Canonical Ensembles that compose the Grand Canonical Ensemble. The simulations are used to estimate the Gran Canonical…
▽ More
Extracting the kinetic properties of a system whose dynamics depend on the pH of the environment with which it exchanges energy and atoms requires sampling the Grand Canonical Ensemble. As an alternative, we present a novel strategy that requires simulating only the most recurrent Canonical Ensembles that compose the Grand Canonical Ensemble. The simulations are used to estimate the Gran Canonical distribution for a specific pH value by reweighting and to construct the transition rate matrix by discretizing the Fokker-Planck equation by Square Root Approximation and robust Perron Cluster Cluster Analysis. As an application, we have studied the tripeptide Ala-Asp-Ala.
△ Less
Submitted 10 July, 2023;
originally announced July 2023.
-
Measurement of ambient radon progeny decay rates and energy spectra in liquid argon using the MicroBooNE detector
Authors:
MicroBooNE collaboration,
P. Abratenko,
O. Alterkait,
D. Andrade Aldana,
L. Arellano,
J. Asaadi,
A. Ashkenazi,
S. Balasubramanian,
B. Baller,
G. Barr,
D. Barrow,
J. Barrow,
V. Basque,
O. Benevides Rodrigues,
S. Berkman,
A. Bhanderi,
A. Bhat,
M. Bhattacharya,
M. Bishai,
A. Blake,
B. Bogart,
T. Bolton,
J. Y. Book,
L. Camilleri,
Y. Cao
, et al. (166 additional authors not shown)
Abstract:
We report measurements of radon progeny in liquid argon within the MicroBooNE time projection chamber (LArTPC). The presence of specific radon daughters in MicroBooNE's 85 metric tons of active liquid argon bulk is probed with newly developed charge-based low-energy reconstruction tools and analysis techniques to detect correlated $^{214}$Bi-$^{214}$Po radioactive decays. Special datasets taken du…
▽ More
We report measurements of radon progeny in liquid argon within the MicroBooNE time projection chamber (LArTPC). The presence of specific radon daughters in MicroBooNE's 85 metric tons of active liquid argon bulk is probed with newly developed charge-based low-energy reconstruction tools and analysis techniques to detect correlated $^{214}$Bi-$^{214}$Po radioactive decays. Special datasets taken during periods of active radon do** enable new demonstrations of the calorimetric capabilities of single-phase neutrino LArTPCs for $β$ and $α$ particles with electron-equivalent energies ranging from 0.1 to 3.0 MeV. By applying $^{214}$Bi-$^{214}$Po detection algorithms to data recorded over a 46-day period, no statistically significant presence of radioactive $^{214}$Bi is detected, and a limit on the activity is placed at $<0.35$ mBq/kg at the 95% confidence level. This bulk $^{214}$Bi radiopurity limit -- the first ever reported for a liquid argon detector incorporating liquid-phase purification -- is then further discussed in relation to the targeted upper limit of 1 mBq/kg on bulk $^{222}$Rn activity for the DUNE neutrino detector.
△ Less
Submitted 22 March, 2024; v1 submitted 6 July, 2023;
originally announced July 2023.
-
Surface Protection and Activation of Mid-IR Plasmonic Waveguides for Spectroscopy of Liquids
Authors:
Mauro David,
Ismael C. Doganlar,
Daniele Nazzari,
Elena Arigliani,
Dominik Wacht,
Masiar Sistani,
Hermann Detz,
Georg Ramer,
Bernhard Lendl,
Walter M. Weber,
Gottfried Strasser,
Borislav Hinkov
Abstract:
Liquid spectroscopy in the mid-infrared spectral range is a very powerful, yet premature technique for selective and sensitive molecule detection. Due to the lack of suitable concepts and materials for versatile miniaturized sensors, it is often still limited to bulky systems and offline analytics. Mid-infrared plasmonics is a promising field of current research for such compact and surface-sensit…
▽ More
Liquid spectroscopy in the mid-infrared spectral range is a very powerful, yet premature technique for selective and sensitive molecule detection. Due to the lack of suitable concepts and materials for versatile miniaturized sensors, it is often still limited to bulky systems and offline analytics. Mid-infrared plasmonics is a promising field of current research for such compact and surface-sensitive structures, enabling new pathways for much-needed photonic integrated sensors. In this work, we focus on extending the concept of Ge/Au-based mid-infrared plasmonic waveguides to enable broadband liquid detection. Through the implementation of high-quality dielectric passivation layers deposited by atomic layer deposition (ALD), we cover the weak and water-soluble Ge native oxide. We show that approximately 10 nm of e.g. Al2O3 or ZrO2 can already protect the plasmonic waveguides for up to 90 min of direct water exposure. This unlocks integrated sensing schemes for broadband molecule detection based on mid-infrared plasmonics. In a proof-of-concept experiment, we further demonstrate that the ZrO2 coated waveguides can be activated by surface functionalization, allowing the selective measurement of diethyl ether at a wavelength of 9.38 μm.
△ Less
Submitted 25 May, 2023;
originally announced May 2023.
-
First measurement of $η$ production in neutrino interactions on argon with MicroBooNE
Authors:
MicroBooNE collaboration,
P. Abratenko,
O. Alterkait,
D. Andrade Aldana,
J. Anthony,
L. Arellano,
J. Asaadi,
A. Ashkenazi,
S. Balasubramanian,
B. Baller,
G. Barr,
J. Barrow,
V. Basque,
O. Benevides Rodrigues,
S. Berkman,
A. Bhanderi,
A. Bhat,
M. Bhattacharya,
M. Bishai,
A. Blake,
B. Bogart,
T. Bolton,
J. Y. Book,
L. Camilleri,
Y. Cao
, et al. (164 additional authors not shown)
Abstract:
We present a measurement of $η$ production from neutrino interactions on argon with the MicroBooNE detector. The modeling of resonant neutrino interactions on argon is a critical aspect of the neutrino oscillation physics program being carried out by the DUNE and Short Baseline Neutrino programs. $η$ production in neutrino interactions provides a powerful new probe of resonant interactions, comple…
▽ More
We present a measurement of $η$ production from neutrino interactions on argon with the MicroBooNE detector. The modeling of resonant neutrino interactions on argon is a critical aspect of the neutrino oscillation physics program being carried out by the DUNE and Short Baseline Neutrino programs. $η$ production in neutrino interactions provides a powerful new probe of resonant interactions, complementary to pion channels, and is particularly suited to the study of higher-order resonances beyond the $Δ(1232)$. We measure a flux-integrated cross section for neutrino-induced $η$ production on argon of $3.22 \pm 0.84 \; \textrm{(stat.)} \pm 0.86 \; \textrm{(syst.)}$ $10^{-41}{\textrm{cm}}^{2}$/nucleon. By demonstrating the successful reconstruction of the two photons resulting from $η$ production, this analysis enables a novel calibration technique for electromagnetic showers in GeV accelerator neutrino experiments.
△ Less
Submitted 4 May, 2024; v1 submitted 25 May, 2023;
originally announced May 2023.
-
Synthesis and scintillation properties of some dense X-ray phosphors
Authors:
C Dujardin,
A. Garcia-Murillo,
C. Pedrini,
C. Madej,
C. Goutaudier,
A. Koch,
A. G. Petrosyan,
M. J. Weber
Abstract:
Many ultra-dense lutetium or gadolinium based compounds doped with Eu 3+ have been prepared. This paper reports on the major scintillation performances of these compounds. One of them (Lu 2 O 3 :Eu) is particularly promising and have been deposited on a screen. Performances of such a screen are presented.
Many ultra-dense lutetium or gadolinium based compounds doped with Eu 3+ have been prepared. This paper reports on the major scintillation performances of these compounds. One of them (Lu 2 O 3 :Eu) is particularly promising and have been deposited on a screen. Performances of such a screen are presented.
△ Less
Submitted 15 May, 2023;
originally announced May 2023.
-
First demonstration of $\mathcal{O}(1\,\text{ns})$ timing resolution in the MicroBooNE liquid argon time projection chamber
Authors:
MicroBooNE collaboration,
P. Abratenko,
O. Alterkait,
D. Andrade Aldana,
J. Anthony,
L. Arellano,
J. Asaadi,
A. Ashkenazi,
S. Balasubramanian,
B. Baller,
G. Barr,
J. Barrow,
V. Basque,
O. Benevides Rodrigues,
S. Berkman,
A. Bhanderi,
M. Bhattacharya,
M. Bishai,
A. Blake,
B. Bogart,
T. Bolton,
J. Y. Book,
L. Camilleri,
Y. Cao,
D. Caratelli
, et al. (163 additional authors not shown)
Abstract:
MicroBooNE is a neutrino experiment located in the Booster Neutrino Beamline (BNB) at Fermilab, which collected data from 2015 to 2021. MicroBooNE's liquid argon time projection chamber (LArTPC) is accompanied by a photon detection system consisting of 32 photomultiplier tubes used to measure the argon scintillation light and determine the timing of neutrino interactions. Analysis techniques combi…
▽ More
MicroBooNE is a neutrino experiment located in the Booster Neutrino Beamline (BNB) at Fermilab, which collected data from 2015 to 2021. MicroBooNE's liquid argon time projection chamber (LArTPC) is accompanied by a photon detection system consisting of 32 photomultiplier tubes used to measure the argon scintillation light and determine the timing of neutrino interactions. Analysis techniques combining light signals and reconstructed tracks are applied to achieve a neutrino interaction time resolution of $\mathcal{O}(1\,\text{ns})$. The result obtained allows MicroBooNE to access the ns neutrino pulse structure of the BNB for the first time. The timing resolution achieved will enable significant enhancement of cosmic background rejection for all neutrino analyses. Furthermore, the ns timing resolution opens new avenues to search for long-lived-particles such as heavy neutral leptons in MicroBooNE, as well as in future large LArTPC experiments, namely the SBN program and DUNE.
△ Less
Submitted 29 August, 2023; v1 submitted 4 April, 2023;
originally announced April 2023.
-
Additive manufacturing of solid diffractive optical elements via near index matching
Authors:
Reut Kedem Orange,
Nadav Opatovski,
Dafei Xiao,
Boris Ferdman,
Onit Alalouf,
Sushanta Kumar Pal,
Ziyun Wang,
Henrik von der Emde,
Michael Weber,
Steffen J. Sahl,
Aleks Ponjavic,
Ady Arie,
Stefan W. Hell,
Yoav Shechtman
Abstract:
Diffractive optical elements (DOEs) have a wide range of applications in optics and photonics, thanks to their capability to perform complex wavefront sha** in a compact form. However, widespread applicability of DOEs is still limited, because existing fabrication methods are cumbersome and expensive. Here, we present a simple and cost-effective fabrication approach for solid, high-performance D…
▽ More
Diffractive optical elements (DOEs) have a wide range of applications in optics and photonics, thanks to their capability to perform complex wavefront sha** in a compact form. However, widespread applicability of DOEs is still limited, because existing fabrication methods are cumbersome and expensive. Here, we present a simple and cost-effective fabrication approach for solid, high-performance DOEs. The method is based on conjugating two nearly refractive index-matched solidifiable transparent materials. The index matching allows for extreme scaling up of the elements in the axial dimension, which enables simple fabrication of a template using commercially available 3D printing at tens-of-micrometer resolution. We demonstrated the approach by fabricating and using DOEs serving as microlens arrays, vortex plates, including for highly sensitive applications such as vector beam generation and super-resolution microscopy using MINSTED, and phase-masks for three-dimensional single-molecule localization microscopy. Beyond the advantage of making DOEs widely accessible by drastically simplifying their production, the method also overcomes difficulties faced by existing methods in fabricating highly complex elements, such as high-order vortex plates, and spectrum-encoding phase masks for microscopy.
△ Less
Submitted 27 March, 2023;
originally announced March 2023.
-
Disparity in the Evolving COVID-19 Collaboration Network
Authors:
Huimin Xu,
Redoan Rahman,
Ajay Jaiswal,
Julia Fensel,
Abhinav Peri,
Ka-mesh Peri,
Griffin M Weber,
Ying Ding
Abstract:
The COVID 19 pandemic has paused many ongoing research projects and unified researchers' attention to focus on COVID 19 related issues. Our project traces 712294 scientists' publications related to COVID 19 for two years, from January 2020 to December 2021, to detect the dynamic evolution patterns of the COVID 19 collaboration network over time. By studying the collaboration network of COVID 19 sc…
▽ More
The COVID 19 pandemic has paused many ongoing research projects and unified researchers' attention to focus on COVID 19 related issues. Our project traces 712294 scientists' publications related to COVID 19 for two years, from January 2020 to December 2021, to detect the dynamic evolution patterns of the COVID 19 collaboration network over time. By studying the collaboration network of COVID 19 scientists, we observe how a new scientific community has been built in preparation for a sudden shock. The number of newcomers grows incrementally, and the connectivity of the collaboration network shifts from loose to tight promptly. Even though every scientist has an equal opportunity to start a study, collaboration disparity still exists. Following the scale-free distribution, only a few top authors are highly connected with other authors. These top authors are more likely to attract newcomers and work with each other. As the collaboration network evolves, the increase rate in the probability of attracting newcomers for authors with higher degrees increases, whereas the increase rates in the likelihood of forming new links among authors with higher degrees decreases. This highlights the interesting trend that the COVID pandemic alters the research collaboration trends that star scientists are starting to collaborate more with newcomers but less with existing collaborators, which, in a certain way, reduces the collaboration disparity.
△ Less
Submitted 4 March, 2023;
originally announced March 2023.
-
Effect of iron thicknesses on spin transport in a Fe/Au bilayer system
Authors:
J. Briones,
M. Weber,
B. Stadtmüller,
H. C. Schneider,
B. Rethfeld
Abstract:
This paper is concerned with a theoretical analysis of the behavior of optically excited spin currents in bilayer and multilayer systems of ferromagnetic and normal metals. As the propagation, control and manipulation of the spin currents created in ferromagnets by femtosecond optical pulses is of particular interest, we examine the influence of different thicknesses of the constituent layers for…
▽ More
This paper is concerned with a theoretical analysis of the behavior of optically excited spin currents in bilayer and multilayer systems of ferromagnetic and normal metals. As the propagation, control and manipulation of the spin currents created in ferromagnets by femtosecond optical pulses is of particular interest, we examine the influence of different thicknesses of the constituent layers for the case of electrons excited several electronvolts above the Fermi level. Using a Monte-Carlo simulation framework for such highly excited electrons, we first examine the spatio-temporal characteristics of the spin current density driven in a Fe layer, where the absorption profile of the light pulses plays an important role. Further, we examine how the combination of light absorption profiles, spin-dependent transmission probabilities, and iron layer thicknesses affect spin current density in a Fe/Au bilayer system. For high-energy electrons studied here, the interface and secondary electron generation have a small influence on spin transport in the bilayer system. However, we find that spin injection from one layer to another is most effective within a certain range of iron layer thicknesses.
△ Less
Submitted 2 February, 2023;
originally announced February 2023.
-
Surface-Sensitive Raman Scattering by Transferable Nanoporous Plasmonic Membranes
Authors:
Roman M. Wyss,
Günter Kewes,
Martin Frimmer,
Karl-Philipp Schlichting,
Markus Parzefall,
Eric Bonvin,
Martin F. Sarott,
Morgan Trassin,
Lala Habibova,
Giorgia Marcelli,
Jan Vermant,
Lukas Novotny,
Mads C. Weber,
Sebastian Heeg
Abstract:
Raman spectroscopy is a powerful technique to characterize materials. It probes non-destructively chemical composition, crystallinity, defects, strain and coupling phenomena. However, the Raman response of surfaces or thin films is often weak and obscured by dominant bulk signals. Here we overcome this limitation by placing a transferable porous gold membrane (PAuM) on top of the surface of intere…
▽ More
Raman spectroscopy is a powerful technique to characterize materials. It probes non-destructively chemical composition, crystallinity, defects, strain and coupling phenomena. However, the Raman response of surfaces or thin films is often weak and obscured by dominant bulk signals. Here we overcome this limitation by placing a transferable porous gold membrane (PAuM) on top of the surface of interest. Slot-like nanopores in the membrane act as plasmonic slot antennas and enhance the Raman response of the surface or thin film underneath. Simultaneously, the PAuM suppresses the penetration of the excitation laser into the bulk, efficiently blocking the bulk Raman signal. Using graphene as a model surface, we show that these two simultaneous effects lead to an increase in the surface-to-bulk Raman signal ratio by three orders of magnitude. We find that 90% of the Raman enhancement occurs within the top 2.5 of the material, demonstrating truly surface-sensitive Raman scattering. To validate our approach, we analyze the surface of a LaNiO3 thin film. We observe a Raman mode splitting for the LaNiO3 surface-layer, which is spectroscopic evidence that the surface structure differs from the bulk. This result underpins that PAuM give direct access to Raman signatures of surfaces and their structural properties.
△ Less
Submitted 10 January, 2023;
originally announced January 2023.
-
Highly-parallelized simulation of a pixelated LArTPC on a GPU
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo,
J. Anderson
, et al. (1282 additional authors not shown)
Abstract:
The rapid development of general-purpose computing on graphics processing units (GPGPU) is allowing the implementation of highly-parallelized Monte Carlo simulation chains for particle physics experiments. This technique is particularly suitable for the simulation of a pixelated charge readout for time projection chambers, given the large number of channels that this technology employs. Here we pr…
▽ More
The rapid development of general-purpose computing on graphics processing units (GPGPU) is allowing the implementation of highly-parallelized Monte Carlo simulation chains for particle physics experiments. This technique is particularly suitable for the simulation of a pixelated charge readout for time projection chambers, given the large number of channels that this technology employs. Here we present the first implementation of a full microphysical simulator of a liquid argon time projection chamber (LArTPC) equipped with light readout and pixelated charge readout, developed for the DUNE Near Detector. The software is implemented with an end-to-end set of GPU-optimized algorithms. The algorithms have been written in Python and translated into CUDA kernels using Numba, a just-in-time compiler for a subset of Python and NumPy instructions. The GPU implementation achieves a speed up of four orders of magnitude compared with the equivalent CPU version. The simulation of the current induced on $10^3$ pixels takes around 1 ms on the GPU, compared with approximately 10 s on the CPU. The results of the simulation are compared against data from a pixel-readout LArTPC prototype.
△ Less
Submitted 28 February, 2023; v1 submitted 19 December, 2022;
originally announced December 2022.
-
Simultaneous MMC readout using a tailored μMUX based readout system
Authors:
Daniel Richter,
Mathias Wegner,
Felix Ahrens,
Christian Enss,
Nick Karcher,
Oliver Sander,
Constantin Schuster,
Marc Weber,
Thomas Wolber,
Sebastian Kempf
Abstract:
Magnetic microcalorimeters (MMCs) are cryogenic, energy-dispersive single-particle detectors providing excellent energy resolution, intrinsically fast signal rise time, quantum efficiency close to 100\%, large dynamic range as well as almost ideal linear response. One of the remaining challenges to be overcome to ultimately allow for the utilization of large-scale MMC based detector arrays with th…
▽ More
Magnetic microcalorimeters (MMCs) are cryogenic, energy-dispersive single-particle detectors providing excellent energy resolution, intrinsically fast signal rise time, quantum efficiency close to 100\%, large dynamic range as well as almost ideal linear response. One of the remaining challenges to be overcome to ultimately allow for the utilization of large-scale MMC based detector arrays with thousands to millions of individual pixels is the realization of a SQUID based multiplexing technique particularly tailored for MMC readout. Within this context, we report on the first truly multiplexed readout of an MMC based detector array using a frequency-division multiplexing approach realized by a custom microwave SQUID multiplexer based readout system.
△ Less
Submitted 27 March, 2023; v1 submitted 14 November, 2022;
originally announced November 2022.
-
Identification and reconstruction of low-energy electrons in the ProtoDUNE-SP detector
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo,
J. Anderson
, et al. (1235 additional authors not shown)
Abstract:
Measurements of electrons from $ν_e$ interactions are crucial for the Deep Underground Neutrino Experiment (DUNE) neutrino oscillation program, as well as searches for physics beyond the standard model, supernova neutrino detection, and solar neutrino measurements. This article describes the selection and reconstruction of low-energy (Michel) electrons in the ProtoDUNE-SP detector. ProtoDUNE-SP is…
▽ More
Measurements of electrons from $ν_e$ interactions are crucial for the Deep Underground Neutrino Experiment (DUNE) neutrino oscillation program, as well as searches for physics beyond the standard model, supernova neutrino detection, and solar neutrino measurements. This article describes the selection and reconstruction of low-energy (Michel) electrons in the ProtoDUNE-SP detector. ProtoDUNE-SP is one of the prototypes for the DUNE far detector, built and operated at CERN as a charged particle test beam experiment. A sample of low-energy electrons produced by the decay of cosmic muons is selected with a purity of 95%. This sample is used to calibrate the low-energy electron energy scale with two techniques. An electron energy calibration based on a cosmic ray muon sample uses calibration constants derived from measured and simulated cosmic ray muon events. Another calibration technique makes use of the theoretically well-understood Michel electron energy spectrum to convert reconstructed charge to electron energy. In addition, the effects of detector response to low-energy electron energy scale and its resolution including readout electronics threshold effects are quantified. Finally, the relation between the theoretical and reconstructed low-energy electron energy spectrum is derived and the energy resolution is characterized. The low-energy electron selection presented here accounts for about 75% of the total electron deposited energy. After the addition of lost energy using a Monte Carlo simulation, the energy resolution improves from about 40% to 25% at 50~MeV. These results are used to validate the expected capabilities of the DUNE far detector to reconstruct low-energy electrons.
△ Less
Submitted 31 May, 2023; v1 submitted 2 November, 2022;
originally announced November 2022.
-
A review of Girsanov Reweighting and of Square Root Approximation for building molecular Markov State Models
Authors:
Luca Donati,
Marcus Weber,
Bettina G. Keller
Abstract:
Dynamical reweighting methods permit to estimate kinetic observables of a stochastic process governed by a target potential $\tilde{V}(x)$ from trajectories that have been generated at a different potential $V(x)$. In this article, we present Girsanov reweighting and Square Root Approximation (SqRA): the first method reweights path probabilities exploiting the Girsanov theorem and can be applied t…
▽ More
Dynamical reweighting methods permit to estimate kinetic observables of a stochastic process governed by a target potential $\tilde{V}(x)$ from trajectories that have been generated at a different potential $V(x)$. In this article, we present Girsanov reweighting and Square Root Approximation (SqRA): the first method reweights path probabilities exploiting the Girsanov theorem and can be applied to Markov State Models (MSMs) to reweight transition probabilities; the second method was originally developed to discretize the Fokker-Planck operator into a transition rate matrix, but here we implement it into a reweighting scheme for transition rates. We begin by reviewing the theoretical background of the methods, then present two applications relevant to Molecular Dynamics (MD), highlighting their strengths and weaknesses.
△ Less
Submitted 23 November, 2022; v1 submitted 21 September, 2022;
originally announced September 2022.
-
Assessing transition rates as functions of environmental variables
Authors:
Luca Donati,
Marcus Weber
Abstract:
We present a method to estimate the transition rates of molecular systems under different environmental conditions which cause the formation or the breaking of bonds and require the sampling of the Grand Canonical Ensemble. For this purpose, we model the molecular system in terms of probable "scenarios", governed by different potential energy functions, which are separately sampled by classical MD…
▽ More
We present a method to estimate the transition rates of molecular systems under different environmental conditions which cause the formation or the breaking of bonds and require the sampling of the Grand Canonical Ensemble. For this purpose, we model the molecular system in terms of probable "scenarios", governed by different potential energy functions, which are separately sampled by classical MD simulations. Reweighting the canonical distribution of each scenario according to specific environmental variables, we estimate the grand canonical distribution, then we use the Square Root Approximation (SqRA) method to discretize the Fokker-Planck operator into a rate matrix and the robust Perron Cluster Cluster Analysis (PCCA+) method to coarse-grain the kinetic model. This permits to efficiently estimate the transition rates of conformational states as functions of environmental variables, for example, the local pH at a cell membrane. In this work we formalize the theoretical framework of the procedure and we present a numerical experiment comparing the results with those provided by a constant-pH method based on non-equilibrium Molecular Dynamics Monte Carlo simulations. The method is relevant for the development of new drug design strategies which take into account how the cellular environment influences biochemical processes.
△ Less
Submitted 6 November, 2022; v1 submitted 13 July, 2022;
originally announced July 2022.
-
Reconstruction of interactions in the ProtoDUNE-SP detector with Pandora
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
F. Akbar,
B. Ali-Mohammadzadeh,
K. Allison,
S. Alonso Monsalve,
M. AlRashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo
, et al. (1203 additional authors not shown)
Abstract:
The Pandora Software Development Kit and algorithm libraries provide pattern-recognition logic essential to the reconstruction of particle interactions in liquid argon time projection chamber detectors. Pandora is the primary event reconstruction software used at ProtoDUNE-SP, a prototype for the Deep Underground Neutrino Experiment far detector. ProtoDUNE-SP, located at CERN, is exposed to a char…
▽ More
The Pandora Software Development Kit and algorithm libraries provide pattern-recognition logic essential to the reconstruction of particle interactions in liquid argon time projection chamber detectors. Pandora is the primary event reconstruction software used at ProtoDUNE-SP, a prototype for the Deep Underground Neutrino Experiment far detector. ProtoDUNE-SP, located at CERN, is exposed to a charged-particle test beam. This paper gives an overview of the Pandora reconstruction algorithms and how they have been tailored for use at ProtoDUNE-SP. In complex events with numerous cosmic-ray and beam background particles, the simulated reconstruction and identification efficiency for triggered test-beam particles is above 80% for the majority of particle type and beam momentum combinations. Specifically, simulated 1 GeV/$c$ charged pions and protons are correctly reconstructed and identified with efficiencies of 86.1$\pm0.6$% and 84.1$\pm0.6$%, respectively. The efficiencies measured for test-beam data are shown to be within 5% of those predicted by the simulation.
△ Less
Submitted 17 July, 2023; v1 submitted 29 June, 2022;
originally announced June 2022.
-
Separation of track- and shower-like energy deposits in ProtoDUNE-SP using a convolutional neural network
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
B. Ali-Mohammadzadeh,
T. Alion,
K. Allison,
S. Alonso Monsalve,
M. AlRashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo,
J. Anderson
, et al. (1204 additional authors not shown)
Abstract:
Liquid argon time projection chamber detector technology provides high spatial and calorimetric resolutions on the charged particles traversing liquid argon. As a result, the technology has been used in a number of recent neutrino experiments, and is the technology of choice for the Deep Underground Neutrino Experiment (DUNE). In order to perform high precision measurements of neutrinos in the det…
▽ More
Liquid argon time projection chamber detector technology provides high spatial and calorimetric resolutions on the charged particles traversing liquid argon. As a result, the technology has been used in a number of recent neutrino experiments, and is the technology of choice for the Deep Underground Neutrino Experiment (DUNE). In order to perform high precision measurements of neutrinos in the detector, final state particles need to be effectively identified, and their energy accurately reconstructed. This article proposes an algorithm based on a convolutional neural network to perform the classification of energy deposits and reconstructed particles as track-like or arising from electromagnetic cascades. Results from testing the algorithm on data from ProtoDUNE-SP, a prototype of the DUNE far detector, are presented. The network identifies track- and shower-like particles, as well as Michel electrons, with high efficiency. The performance of the algorithm is consistent between data and simulation.
△ Less
Submitted 30 June, 2022; v1 submitted 31 March, 2022;
originally announced March 2022.
-
Scintillation light detection in the 6-m drift-length ProtoDUNE Dual Phase liquid argon TPC
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
B. Ali-Mohammadzadeh,
T. Alion,
K. Allison,
S. Alonso Monsalve,
M. AlRashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo,
J. Anderson
, et al. (1202 additional authors not shown)
Abstract:
DUNE is a dual-site experiment for long-baseline neutrino oscillation studies, neutrino astrophysics and nucleon decay searches. ProtoDUNE Dual Phase (DP) is a 6x6x6m3 liquid argon time-projection-chamber (LArTPC) that recorded cosmic-muon data at the CERN Neutrino Platform in 2019-2020 as a prototype of the DUNE Far Detector. Charged particles propagating through the LArTPC produce ionization and…
▽ More
DUNE is a dual-site experiment for long-baseline neutrino oscillation studies, neutrino astrophysics and nucleon decay searches. ProtoDUNE Dual Phase (DP) is a 6x6x6m3 liquid argon time-projection-chamber (LArTPC) that recorded cosmic-muon data at the CERN Neutrino Platform in 2019-2020 as a prototype of the DUNE Far Detector. Charged particles propagating through the LArTPC produce ionization and scintillation light. The scintillation light signal in these detectors can provide the trigger for non-beam events. In addition, it adds precise timing capabilities and improves the calorimetry measurements. In ProtoDUNE-DP, scintillation and electroluminescence light produced by cosmic muons in the LArTPC is collected by photomultiplier tubes placed up to 7 m away from the ionizing track. In this paper, the ProtoDUNE-DP photon detection system performance is evaluated with a particular focus on the different wavelength shifters, such as PEN and TPB, and the use of Xe-doped LAr, considering its future use in giant LArTPCs. The scintillation light production and propagation processes are analyzed and a comparison of simulation to data is performed, improving understanding of the liquid argon properties
△ Less
Submitted 3 June, 2022; v1 submitted 30 March, 2022;
originally announced March 2022.
-
Observation of Radon Mitigation in MicroBooNE by a Liquid Argon Filtration System
Authors:
MicroBooNE collaboration,
P. Abratenko,
J. Anthony,
L. Arellano,
J. Asaadi,
A. Ashkenazi,
S. Balasubramanian,
B. Baller,
C. Barnes,
G. Barr,
J. Barrow,
V. Basque,
L. Bathe-Peters,
O. Benevides Rodrigues,
S. Berkman,
A. Bhanderi,
A. Bhat,
M. Bhattacharya,
M. Bishai,
A. Blake,
T. Bolton,
J. Y. Book,
L. Camilleri,
D. Caratelli,
I. Caro Terrazas
, et al. (168 additional authors not shown)
Abstract:
The MicroBooNE liquid argon time projection chamber (LArTPC) maintains a high level of liquid argon purity through the use of a filtration system that removes electronegative contaminants in continuously-circulated liquid, recondensed boil off, and externally supplied argon gas. We use the MicroBooNE LArTPC to reconstruct MeV-scale radiological decays. Using this technique we measure the liquid ar…
▽ More
The MicroBooNE liquid argon time projection chamber (LArTPC) maintains a high level of liquid argon purity through the use of a filtration system that removes electronegative contaminants in continuously-circulated liquid, recondensed boil off, and externally supplied argon gas. We use the MicroBooNE LArTPC to reconstruct MeV-scale radiological decays. Using this technique we measure the liquid argon filtration system's efficacy at removing radon. This is studied by placing a 500 kBq $^{222}$Rn source upstream of the filters and searching for a time-dependent increase in the number of radiological decays in the LArTPC. In the context of two models for radon mitigation via a liquid argon filtration system, a slowing mechanism and a trap** mechanism, MicroBooNE data supports a radon reduction factor of greater than 99.999% or 97%, respectively. Furthermore, a radiological survey of the filters found that the copper-based filter material was the primary medium that removed the $^{222}$Rn. This is the first observation of radon mitigation in liquid argon with a large-scale copper-based filter and could offer a radon mitigation solution for future large LArTPCs.
△ Less
Submitted 26 October, 2022; v1 submitted 18 March, 2022;
originally announced March 2022.
-
Low-Energy Physics in Neutrino LArTPCs
Authors:
D. Caratelli,
W. Foreman,
A. Friedland,
S. Gardiner,
I. Gil-Botella,
G. Karagiorgi,
M. Kirby,
G. Lehmann Miotto,
B. R. Littlejohn,
M. Mooney,
J. Reichenbacher,
A. Sousa,
K. Scholberg,
J. Yu,
T. Yang,
S. Andringa,
J. Asaadi,
T. J. C. Bezerra,
F. Capozzi,
F. Cavanna,
E. Church,
A. Himmel,
T. Junk,
J. Klein,
I. Lepetic
, et al. (264 additional authors not shown)
Abstract:
In this white paper, we outline some of the scientific opportunities and challenges related to detection and reconstruction of low-energy (less than 100 MeV) signatures in liquid argon time-projection chamber (LArTPC) detectors. Key takeaways are summarized as follows. 1) LArTPCs have unique sensitivity to a range of physics and astrophysics signatures via detection of event features at and below…
▽ More
In this white paper, we outline some of the scientific opportunities and challenges related to detection and reconstruction of low-energy (less than 100 MeV) signatures in liquid argon time-projection chamber (LArTPC) detectors. Key takeaways are summarized as follows. 1) LArTPCs have unique sensitivity to a range of physics and astrophysics signatures via detection of event features at and below the few tens of MeV range. 2) Low-energy signatures are an integral part of GeV-scale accelerator neutrino interaction final states, and their reconstruction can enhance the oscillation physics sensitivities of LArTPC experiments. 3) BSM signals from accelerator and natural sources also generate diverse signatures in the low-energy range, and reconstruction of these signatures can increase the breadth of BSM scenarios accessible in LArTPC-based searches. 4) Neutrino interaction cross sections and other nuclear physics processes in argon relevant to sub-hundred-MeV LArTPC signatures are poorly understood. Improved theory and experimental measurements are needed. Pion decay-at-rest sources and charged particle and neutron test beams are ideal facilities for experimentally improving this understanding. 5) There are specific calibration needs in the low-energy range, as well as specific needs for control and understanding of radiological and cosmogenic backgrounds. 6) Novel ideas for future LArTPC technology that enhance low-energy capabilities should be explored. These include novel charge enhancement and readout systems, enhanced photon detection, low radioactivity argon, and xenon do**. 7) Low-energy signatures, whether steady-state or part of a supernova burst or larger GeV-scale event topology, have specific triggering, DAQ and reconstruction requirements that must be addressed outside the scope of conventional GeV-scale data collection and analysis pathways.
△ Less
Submitted 1 March, 2022;
originally announced March 2022.
-
A facility for radiation hardness studies based on a medical cyclotron
Authors:
John Anders,
Saverio Braccini,
Tommaso Stefano Carzaniga,
Pierluigi Casolaro,
Meghranjana Chatterjee,
Gaia Dellepiane,
Laura Franconi,
Lea Halser,
Armin Ilg,
Isidre Mateu,
Federico Meloni,
Claudia Merlassino,
Antonio Miucci,
Roman Müller,
Marco Rimoldi,
Michele Weber
Abstract:
The development of instrumentation for operation in high-radiation environments represents a challenge in various research fields, particularly in particle physics experiments and space missions, and drives an ever-increasing demand for irradiation facilities dedicated to radiation hardness studies. Depending on the application, different needs arise in terms of particle type, energy and dose rate…
▽ More
The development of instrumentation for operation in high-radiation environments represents a challenge in various research fields, particularly in particle physics experiments and space missions, and drives an ever-increasing demand for irradiation facilities dedicated to radiation hardness studies. Depending on the application, different needs arise in terms of particle type, energy and dose rate. In this article, we present a versatile installation based on a medical cyclotron located at the Bern University Hospital (Inselspital), which is used as a controlled 18-MeV proton source. This accelerator is used for daily production of medical radioisotopes, as well as for multidisciplinary research, thanks to a 6.5-meter long beam transfer line that terminates in an independent bunker, dedicated only to scientific activities. The facility offers a wide range of proton fluxes, due to an adjustable beam current from approximately 10 pA to the micro-ampere range, together with a series of steering and focusing magnets along the beamline that allow for the beam spot to be focused down to a few mm^2. The beamline can be instrumented with a variety of beam monitoring detectors, collimators, and beam current measurement devices to precisely control the irradiation conditions. The facility also hosts a well equipped laboratory dedicated to the characterisation of samples after irradiation. An experimental validation of the irradiation setup, with proton fluxes ranging from $5\times10^9$ cm$^{-2}$s$^{-1}$ to $4\times10^{11}$ cm$^{-2}$s$^{-1}$, is reported in this article.
△ Less
Submitted 22 March, 2022; v1 submitted 11 January, 2022;
originally announced January 2022.
-
The accomplishment of the Engineering Design Activities of IFMIF/EVEDA: The European Japanese project towards a Li(d,xn) fusion relevant neutron source
Authors:
J. Knaster,
A. Ibarra,
J. Abal,
A. Abou Sena,
F. Arbeiter,
F. Arranz,
J. M. Arroyo,
E. Bargallo,
P. Y. Beauvais,
D. Bernardi,
N. Casal,
J. M. Carmona,
N. Chauvin,
M. Comunian,
O. Delferriere,
A. Delgado,
P. Diaz Arocas,
U. Fischer,
M. Frisoni,
A. Garcia,
P. Garin,
R. Gobin,
P. Gouat,
F. Groesche,
R. Heidinger
, et al. (42 additional authors not shown)
Abstract:
The International Fusion Materials Irradiation Facility (IFMIF), presently in its Engineering Validation and Engineering Design Activities (EVEDA) phase under the frame of the Broader Approach Agreement between Europe and Japan, accomplished in summer 2013, on schedule, its EDA phase with the release of the engineering design report of the IFMIF plant, which is here described. Many improvements of…
▽ More
The International Fusion Materials Irradiation Facility (IFMIF), presently in its Engineering Validation and Engineering Design Activities (EVEDA) phase under the frame of the Broader Approach Agreement between Europe and Japan, accomplished in summer 2013, on schedule, its EDA phase with the release of the engineering design report of the IFMIF plant, which is here described. Many improvements of the design from former phases are implemented, particularly a reduction of beam losses and operational costs thanks to the superconducting accelerator concept, the re-location of the quench tank outside the test cell (TC) with a reduction of tritium inventory and a simplification on its replacement in case of failure, the separation of the irradiation modules from the shielding block gaining irradiation flexibility and enhancement of the remote handling equipment reliability and cost reduction, and the water cooling of the liner and biological shielding of the TC, enhancing the efficiency and economy of the related sub-systems. In addition, the maintenance strategy has been modified to allow a shorter yearly stop of the irradiation operations and a more careful management of the irradiated samples. The design of the IFMIF plant is intimately linked with the EVA phase carried out since the entry into force of IFMIF/EVEDA in June 2007.
△ Less
Submitted 28 December, 2021;
originally announced December 2021.
-
Compensating the delayed electro-optical deflector response
Authors:
Marcel Leutenegger,
Michael Weber,
Henrik von der Emde,
Stefan W. Hell
Abstract:
Due to its immediate response, the electro-optic effect is exploited for high-frequency phase and power modulation and for beam deflection. Besides the immediate response, electro-optic materials exhibit creep due to relaxation processes in the material, which results in a gradual settling of the response when a voltage is applied for tens of milliseconds. A bi-exponential filter can compensate th…
▽ More
Due to its immediate response, the electro-optic effect is exploited for high-frequency phase and power modulation and for beam deflection. Besides the immediate response, electro-optic materials exhibit creep due to relaxation processes in the material, which results in a gradual settling of the response when a voltage is applied for tens of milliseconds. A bi-exponential filter can compensate this behavior, reported here for electro-optic deflectors made of AD*P, such that these deflectors can be used over the entire frequency range of the driver with a residual settling error <0.001 of the deflection.
△ Less
Submitted 1 December, 2021;
originally announced December 2021.
-
Novel Approach for Evaluating Detector-Related Uncertainties in a LArTPC Using MicroBooNE Data
Authors:
MicroBooNE collaboration,
P. Abratenko,
R. An,
J. Anthony,
L. Arellano,
J. Asaadi,
A. Ashkenazi,
S. Balasubramanian,
B. Baller,
C. Barnes,
G. Barr,
V. Basque,
L. Bathe-Peters,
O. Benevides Rodrigues,
S. Berkman,
A. Bhanderi,
A. Bhat,
M. Bishai,
A. Blake,
T. Bolton,
J. Y. Book,
L. Camilleri,
D. Caratelli,
I. Caro Terrazas,
F. Cavanna
, et al. (161 additional authors not shown)
Abstract:
Primary challenges for current and future precision neutrino experiments using liquid argon time projection chambers (LArTPCs) include understanding detector effects and quantifying the associated systematic uncertainties. This paper presents a novel technique for assessing and propagating LArTPC detector-related systematic uncertainties. The technique makes modifications to simulation waveforms b…
▽ More
Primary challenges for current and future precision neutrino experiments using liquid argon time projection chambers (LArTPCs) include understanding detector effects and quantifying the associated systematic uncertainties. This paper presents a novel technique for assessing and propagating LArTPC detector-related systematic uncertainties. The technique makes modifications to simulation waveforms based on a parameterization of observed differences in ionization signals from the TPC between data and simulation, while remaining insensitive to the details of the detector model. The modifications are then used to quantify the systematic differences in low- and high-level reconstructed quantities. This approach could be applied to future LArTPC detectors, such as those used in SBN and DUNE.
△ Less
Submitted 16 June, 2022; v1 submitted 5 November, 2021;
originally announced November 2021.
-
Wire-Cell 3D Pattern Recognition Techniques for Neutrino Event Reconstruction in Large LArTPCs: Algorithm Description and Quantitative Evaluation with MicroBooNE Simulation
Authors:
MicroBooNE collaboration,
P. Abratenko,
R. An,
J. Anthony,
L. Arellano,
J. Asaadi,
A. Ashkenazi,
S. Balasubramanian,
B. Baller,
C. Barnes,
G. Barr,
V. Basque,
L. Bathe-Peters,
O. Benevides Rodrigues,
S. Berkman,
A. Bhanderi,
A. Bhat,
M. Bishai,
A. Blake,
T. Bolton,
J. Y. Book,
L. Camilleri,
D. Caratelli,
I. Caro Terrazas,
R. Castillo Fernandez
, et al. (163 additional authors not shown)
Abstract:
Wire-Cell is a 3D event reconstruction package for liquid argon time projection chambers. Through geometry, time, and drifted charge from multiple readout wire planes, 3D space points with associated charge are reconstructed prior to the pattern recognition stage. Pattern recognition techniques, including track trajectory and $dQ/dx$ (ionization charge per unit length) fitting, 3D neutrino vertex…
▽ More
Wire-Cell is a 3D event reconstruction package for liquid argon time projection chambers. Through geometry, time, and drifted charge from multiple readout wire planes, 3D space points with associated charge are reconstructed prior to the pattern recognition stage. Pattern recognition techniques, including track trajectory and $dQ/dx$ (ionization charge per unit length) fitting, 3D neutrino vertex fitting, track and shower separation, particle-level clustering, and particle identification are then applied on these 3D space points as well as the original 2D projection measurements. A deep neural network is developed to enhance the reconstruction of the neutrino interaction vertex. Compared to traditional algorithms, the deep neural network boosts the vertex efficiency by a relative 30\% for charged-current $ν_e$ interactions. This pattern recognition achieves 80-90\% reconstruction efficiencies for primary leptons, after a 65.8\% (72.9\%) vertex efficiency for charged-current $ν_e$ ($ν_μ$) interactions. Based on the resulting reconstructed particles and their kinematics, we also achieve 15-20\% energy reconstruction resolutions for charged-current neutrino interactions.
△ Less
Submitted 26 December, 2021; v1 submitted 26 October, 2021;
originally announced October 2021.
-
First Measurement of Inclusive Electron-Neutrino and Antineutrino Charged Current Differential Cross Sections in Charged Lepton Energy on Argon in MicroBooNE
Authors:
MicroBooNE collaboration,
P. Abratenko,
R. An,
J. Anthony,
L. Arellano,
J. Asaadi,
A. Ashkenazi,
S. Balasubramanian,
B. Baller,
C. Barnes,
G. Barr,
V. Basque,
L. Bathe-Peters,
O. Benevides Rodrigues,
S. Berkman,
A. Bhanderi,
A. Bhat,
M. Bishai,
A. Blake,
T. Bolton,
J. Y. Book,
L. Camilleri,
D. Caratelli,
I. Caro Terrazas,
R. Castillo Fernandez
, et al. (163 additional authors not shown)
Abstract:
We present the first measurement of the single-differential $ν_e + \barν_e$ charged-current inclusive cross sections on argon in electron or positron energy and in electron or positron scattering cosine over the full angular range. Data were collected using the MicroBooNE liquid argon time projection chamber located off-axis from the Fermilab Neutrinos at the Main Injector beam over an exposure of…
▽ More
We present the first measurement of the single-differential $ν_e + \barν_e$ charged-current inclusive cross sections on argon in electron or positron energy and in electron or positron scattering cosine over the full angular range. Data were collected using the MicroBooNE liquid argon time projection chamber located off-axis from the Fermilab Neutrinos at the Main Injector beam over an exposure of $2.0\times10^{20}$ protons on target. The signal definition includes a 60 MeV threshold on the $ν_e$ or $\barν_e$ energy and a 120 MeV threshold on the electron or positron energy. The measured total and differential cross sections are found to be in agreement with the GENIE, NuWro, and GiBUU neutrino generators.
△ Less
Submitted 3 February, 2022; v1 submitted 14 September, 2021;
originally announced September 2021.
-
Calorimetric classification of track-like signatures in liquid argon TPCs using MicroBooNE data
Authors:
MicroBooNE collaboration,
P. Abratenko,
R. An,
J. Anthony,
J. Asaadi,
A. Ashkenazi,
S. Balasubramanian,
B. Baller,
C. Barnes,
G. Barr,
V. Basque,
L. Bathe-Peters,
O. Benevides Rodrigues,
S. Berkman,
A. Bhanderi,
A. Bhat,
M. Bishai,
A. Blake,
T. Bolton,
L. Camilleri,
D. Caratelli,
I. Caro Terrazas,
R. Castillo Fernandez,
F. Cavanna,
G. Cerati
, et al. (157 additional authors not shown)
Abstract:
The MicroBooNE liquid argon time projection chamber located at Fermilab is a neutrino experiment dedicated to the study of short-baseline oscillations, the measurements of neutrino cross sections in liquid argon, and to the research and development of this novel detector technology. Accurate and precise measurements of calorimetry are essential to the event reconstruction and are achieved by lever…
▽ More
The MicroBooNE liquid argon time projection chamber located at Fermilab is a neutrino experiment dedicated to the study of short-baseline oscillations, the measurements of neutrino cross sections in liquid argon, and to the research and development of this novel detector technology. Accurate and precise measurements of calorimetry are essential to the event reconstruction and are achieved by leveraging the TPC to measure deposited energy per unit length along the particle trajectory, with mm resolution. We describe the non-uniform calorimetric reconstruction performance in the detector, showing dependence on the angle of the particle trajectory. Such non-uniform reconstruction directly affects the performance of the particle identification algorithms which infer particle type from calorimetric measurements. This work presents a new particle identification method which accounts for and effectively addresses such non-uniformity. The newly developed method shows improved performance compared to previous algorithms, illustrated by a 94% proton selection efficiency and a 10% muon mis-identification rate, with a fairly loose selection of tracks performed on beam data. The performance is further demonstrated by identifying exclusive final states in $ν_μ CC$ interactions. While developed using MicroBooNE data and simulation, this method is easily applicable to future LArTPC experiments, such as SBND, ICARUS, and DUNE.
△ Less
Submitted 4 January, 2022; v1 submitted 31 August, 2021;
originally announced September 2021.
-
Low exposure long-baseline neutrino oscillation sensitivity of the DUNE experiment
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
B. Ali-Mohammadzadeh,
T. Alion,
K. Allison,
S. Alonso Monsalve,
M. AlRashed,
C. Alt,
A. Alton,
P. Amedo,
J. Anderson,
C. Andreopoulos,
M. Andreotti
, et al. (1132 additional authors not shown)
Abstract:
The Deep Underground Neutrino Experiment (DUNE) will produce world-leading neutrino oscillation measurements over the lifetime of the experiment. In this work, we explore DUNE's sensitivity to observe charge-parity violation (CPV) in the neutrino sector, and to resolve the mass ordering, for exposures of up to 100 kiloton-megawatt-years (kt-MW-yr). The analysis includes detailed uncertainties on t…
▽ More
The Deep Underground Neutrino Experiment (DUNE) will produce world-leading neutrino oscillation measurements over the lifetime of the experiment. In this work, we explore DUNE's sensitivity to observe charge-parity violation (CPV) in the neutrino sector, and to resolve the mass ordering, for exposures of up to 100 kiloton-megawatt-years (kt-MW-yr). The analysis includes detailed uncertainties on the flux prediction, the neutrino interaction model, and detector effects. We demonstrate that DUNE will be able to unambiguously resolve the neutrino mass ordering at a 3$σ$ (5$σ$) level, with a 66 (100) kt-MW-yr far detector exposure, and has the ability to make strong statements at significantly shorter exposures depending on the true value of other oscillation parameters. We also show that DUNE has the potential to make a robust measurement of CPV at a 3$σ$ level with a 100 kt-MW-yr exposure for the maximally CP-violating values $δ_{\rm CP}} = \pmπ/2$. Additionally, the dependence of DUNE's sensitivity on the exposure taken in neutrino-enhanced and antineutrino-enhanced running is discussed. An equal fraction of exposure taken in each beam mode is found to be close to optimal when considered over the entire space of interest.
△ Less
Submitted 3 September, 2021;
originally announced September 2021.
-
Gaussian mixture model clustering algorithms for the analysis of high-precision mass measurements
Authors:
Colin M. Weber,
Dwaipayan Ray,
Adrian A. Valverde,
Jason A. Clark,
Kumar S. Sharma
Abstract:
The development of the phase-imaging ion-cyclotron resonance (PI-ICR) technique for use in Penning trap mass spectrometry (PTMS) increased the speed and precision with which PTMS experiments can be carried out. In PI-ICR, data sets of the locations of individual ion hits on a detector are created showing how ions cluster together into spots according to their cyclotron frequency. Ideal data sets w…
▽ More
The development of the phase-imaging ion-cyclotron resonance (PI-ICR) technique for use in Penning trap mass spectrometry (PTMS) increased the speed and precision with which PTMS experiments can be carried out. In PI-ICR, data sets of the locations of individual ion hits on a detector are created showing how ions cluster together into spots according to their cyclotron frequency. Ideal data sets would consist of a single, 2D-spherical spot with no other noise, but in practice data sets typically contain multiple spots, non-spherical spots, or significant noise, all of which can make determining the locations of spot centers non-trivial. A method for assigning groups of ions to their respective spots and determining the spot centers is therefore essential for further improving precision and confidence in PI-ICR experiments. We present the class of Gaussian mixture model (GMM) clustering algorithms as an optimal solution. We show that on simulated PI-ICR data, several types of GMM clustering algorithms perform better than other clustering algorithms over a variety of typical scenarios encountered in PI-ICR. The mass spectra of $^{163}\text{Gd}$, $^{163m}\text{Gd}$, $^{162}\text{Tb}$, and $^{162m}\text{Tb}$ measured using PI-ICR at the Canadian Penning trap mass spectrometer were checked using GMMs, producing results that were in close agreement with the previously published values.
△ Less
Submitted 11 December, 2021; v1 submitted 18 August, 2021;
originally announced August 2021.
-
Design, construction and operation of the ProtoDUNE-SP Liquid Argon TPC
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Ali-Mohammadzadeh,
T. Alion,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
A. Alton,
P. Amedo,
J. Anderson,
C. Andreopoulos,
M. Andreotti,
M. P. Andrews
, et al. (1158 additional authors not shown)
Abstract:
The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber (LArTPC) that was constructed and operated in the CERN North Area at the end of the H4 beamline. This detector is a prototype for the first far detector module of the Deep Underground Neutrino Experiment (DUNE), which will be constructed at the Sandford Underground Research Facility (SURF) in Lead, South Dakota, USA.…
▽ More
The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber (LArTPC) that was constructed and operated in the CERN North Area at the end of the H4 beamline. This detector is a prototype for the first far detector module of the Deep Underground Neutrino Experiment (DUNE), which will be constructed at the Sandford Underground Research Facility (SURF) in Lead, South Dakota, USA. The ProtoDUNE-SP detector incorporates full-size components as designed for DUNE and has an active volume of $7\times 6\times 7.2$~m$^3$. The H4 beam delivers incident particles with well-measured momenta and high-purity particle identification. ProtoDUNE-SP's successful operation between 2018 and 2020 demonstrates the effectiveness of the single-phase far detector design. This paper describes the design, construction, assembly and operation of the detector components.
△ Less
Submitted 23 September, 2021; v1 submitted 4 August, 2021;
originally announced August 2021.
-
Three-dimensional assessment of susceptibility-induced signal voids caused by active cardiac implants in the setting of 3.0T CMR
Authors:
Theresa Reiter,
Ingo Weiss,
Oliver M. Weber,
Wolfgang R. Bauer
Abstract:
Recent technical advancements allow cardiac MRI (CMR) examinations in the presence of so-called MRI conditional active cardiac implants at 3.0T. However, the artifact burden caused by susceptibility effects remain an obstacle. All measurements were obtained at a clinical 3.0T scanner using an in-house designed cubic phantom and optimized sequences for artifact evaluation (3D gradient echo sequence…
▽ More
Recent technical advancements allow cardiac MRI (CMR) examinations in the presence of so-called MRI conditional active cardiac implants at 3.0T. However, the artifact burden caused by susceptibility effects remain an obstacle. All measurements were obtained at a clinical 3.0T scanner using an in-house designed cubic phantom and optimized sequences for artifact evaluation (3D gradient echo sequence, multi-slice 2D turbo spin echo sequence), as well as reference sequences according to the ASTM were applied. Four representative active cardiac devices and a generic setup were analysed regarding volume and shape of the signal void. For analysis, a threshold operation applied to the grey value profle of each data data set was used. The presented approach allows the evaluation of signal void and shape even for larger implants such as ICDs. The void shape is influenced by the orientation of the B0-field and the chosen sequence type, as well as the distribution of magnetic material within the implants. The void volume depends both on the device itself, and the sequence type. Disturbances in the B0 and B1 fields exceed the visual signal void. This work presents a reproducible and highly defined approach towards characterising both signal void artifacts at 3.0T and their influencing factors.
△ Less
Submitted 2 April, 2022; v1 submitted 1 August, 2021;
originally announced August 2021.
-
The EXO-200 detector, part II: Auxiliary Systems
Authors:
N. Ackerman,
J. Albert,
M. Auger,
D. J. Auty,
I. Badhrees,
P. S. Barbeau,
L. Bartoszek,
E. Baussan,
V. Belov,
C. Benitez-Medina,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
R. Conley,
S. Cook,
M. Coon,
W. Craddock,
A. Craycraft,
W. Cree,
T. Daniels,
L. Darroch
, et al. (135 additional authors not shown)
Abstract:
The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector op…
▽ More
The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector operation, including cryogenics, xenon handling, and controls. Novel features of the system were driven by the need to protect the thin-walled detector chamber containing the liquid xenon, to achieve high chemical purity of the Xe, and to maintain thermal uniformity across the detector.
△ Less
Submitted 22 October, 2021; v1 submitted 13 July, 2021;
originally announced July 2021.
-
Least-squares fitting of Gaussian spots on graphics processing units
Authors:
Marcel Leutenegger,
Michael Weber
Abstract:
The investigation of samples with a spatial resolution in the nanometer range relies on the precise and stable positioning of the sample. Due to inherent mechanical instabilities of typical sample stages in optical microscopes, it is usually required to control and/or monitor the sample position during the acquisition. The tracking of sparsely distributed fiducial markers at high speed allows stab…
▽ More
The investigation of samples with a spatial resolution in the nanometer range relies on the precise and stable positioning of the sample. Due to inherent mechanical instabilities of typical sample stages in optical microscopes, it is usually required to control and/or monitor the sample position during the acquisition. The tracking of sparsely distributed fiducial markers at high speed allows stabilizing the sample position at millisecond time scales. For this purpose, we present a scalable fitting algorithm with significantly improved performance for two-dimensional Gaussian fits as compared to Gpufit.
△ Less
Submitted 3 June, 2021;
originally announced June 2021.
-
Measurement of the Longitudinal Diffusion of Ionization Electrons in the MicroBooNE Detector
Authors:
P. Abratenko,
R. An,
J. Anthony,
J. Asaadi,
A. Ashkenazi,
S. Balasubramanian,
B. Baller,
C. Barnes,
G. Barr,
V. Basque,
L. Bathe-Peters,
O. Benevides Rodrigues,
S. Berkman,
A. Bhanderi,
A. Bhat,
M. Bishai,
A. Blake,
T. Bolton,
L. Camilleri,
D. Caratelli,
I. Caro Terrazas,
R. Castillo Fernandez,
F. Cavanna,
G. Cerati,
Y. Chen
, et al. (157 additional authors not shown)
Abstract:
Accurate knowledge of electron transport properties is vital to understanding the information provided by liquid argon time projection chambers (LArTPCs). Ionization electron drift-lifetime, local electric field distortions caused by positive ion accumulation, and electron diffusion can all significantly impact the measured signal waveforms. This paper presents a measurement of the effective longi…
▽ More
Accurate knowledge of electron transport properties is vital to understanding the information provided by liquid argon time projection chambers (LArTPCs). Ionization electron drift-lifetime, local electric field distortions caused by positive ion accumulation, and electron diffusion can all significantly impact the measured signal waveforms. This paper presents a measurement of the effective longitudinal electron diffusion coefficient, $D_L$, in MicroBooNE at the nominal electric field strength of 273.9 V/cm. Historically, this measurement has been made in LArTPC prototype detectors. This represents the first measurement in a large-scale (85 tonne active volume) LArTPC operating in a neutrino beam. This is the largest dataset ever used for this measurement. Using a sample of $\sim$70,000 through-going cosmic ray muon tracks tagged with MicroBooNE's cosmic ray tagger system, we measure $D_L = 3.74^{+0.28}_{-0.29}$ cm$^2$/s.
△ Less
Submitted 25 June, 2021; v1 submitted 13 April, 2021;
originally announced April 2021.
-
Deep Underground Neutrino Experiment (DUNE) Near Detector Conceptual Design Report
Authors:
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
G. Adamov,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
Z. Ahmad,
J. Ahmed,
T. Alion,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
A. Alton,
P. Amedo,
J. Anderson,
C. Andreopoulos,
M. P. Andrews,
F. Andrianala,
S. Andringa,
N. Anfimov,
A. Ankowski,
M. Antonova,
S. Antusch
, et al. (1041 additional authors not shown)
Abstract:
This report describes the conceptual design of the DUNE near detector
This report describes the conceptual design of the DUNE near detector
△ Less
Submitted 25 March, 2021;
originally announced March 2021.