-
Study of the decay and production properties of $D_{s1}(2536)$ and $D_{s2}^*(2573)$
Authors:
M. Ablikim,
M. N. Achasov,
P. Adlarson,
O. Afedulidis,
X. C. Ai,
R. Aliberti,
A. Amoroso,
Q. An,
Y. Bai,
O. Bakina,
I. Balossino,
Y. Ban,
H. -R. Bao,
V. Batozskaya,
K. Begzsuren,
N. Berger,
M. Berlowski,
M. Bertani,
D. Bettoni,
F. Bianchi,
E. Bianco,
A. Bortone,
I. Boyko,
R. A. Briere,
A. Brueggemann
, et al. (645 additional authors not shown)
Abstract:
The $e^+e^-\rightarrow D_s^+D_{s1}(2536)^-$ and $e^+e^-\rightarrow D_s^+D^*_{s2}(2573)^-$ processes are studied using data samples collected with the BESIII detector at center-of-mass energies from 4.530 to 4.946~GeV. The absolute branching fractions of $D_{s1}(2536)^- \rightarrow \bar{D}^{*0}K^-$ and $D_{s2}^*(2573)^- \rightarrow \bar{D}^0K^-$ are measured for the first time to be…
▽ More
The $e^+e^-\rightarrow D_s^+D_{s1}(2536)^-$ and $e^+e^-\rightarrow D_s^+D^*_{s2}(2573)^-$ processes are studied using data samples collected with the BESIII detector at center-of-mass energies from 4.530 to 4.946~GeV. The absolute branching fractions of $D_{s1}(2536)^- \rightarrow \bar{D}^{*0}K^-$ and $D_{s2}^*(2573)^- \rightarrow \bar{D}^0K^-$ are measured for the first time to be $(35.9\pm 4.8\pm 3.5)\%$ and $(37.4\pm 3.1\pm 4.6)\%$, respectively. The measurements are in tension with predictions based on the assumption that the $D_{s1}(2536)$ and $D_{s2}^*(2573)$ are dominated by a bare $c\bar{s}$ component. The $e^+e^-\rightarrow D_s^+D_{s1}(2536)^-$ and $e^+e^-\rightarrow D_s^+D^*_{s2}(2573)^-$ cross sections are measured, and a resonant structure at around 4.6~GeV with a width of 50~MeV is observed for the first time with a statistical significance of $15σ$ in the $e^+e^-\rightarrow D_s^+D^*_{s2}(2573)^-$ process. It could be the $Y(4626)$ found by the Belle collaboration in the $D_s^+D_{s1}(2536)^{-}$ final state, since they have similar masses and widths. There is also evidence for a structure at around 4.75~GeV in both processes.
△ Less
Submitted 10 July, 2024;
originally announced July 2024.
-
Construction and commissioning of the collinear laser spectroscopy system at BRIF
Authors:
S. J. Wang,
X. F. Yang,
S. W. Bai,
Y. C. Liu,
P. Zhang,
Y. S. Liu,
H. R. Hu,
H. W. Li,
B. Tang,
B. Q. Cui,
C. Y. He,
X. Ma,
Q. T. Li,
J. H. Chen,
K. Ma,
L. S. Yang,
Z. Y. Hu,
W. L. Pu,
Y. Chen,
Y. F. Guo,
Z. Y. Du,
Z. Yan,
F. L. Liu,
H. R. Wang,
G. Q. Yang
, et al. (2 additional authors not shown)
Abstract:
We have constructed a collinear laser spectroscopy (CLS) system installed at the Bei**g Radioactive Ion-beam Facility (BRIF), aiming to investigate the nuclear properties of unstable nuclei. The first on-line commissioning experiment of this system was performed using the continuous stable ($^{39}$K) and unstable ($^{38}$K) ion beams produced by im**ing a 100-MeV proton beam on a CaO target. Hy…
▽ More
We have constructed a collinear laser spectroscopy (CLS) system installed at the Bei**g Radioactive Ion-beam Facility (BRIF), aiming to investigate the nuclear properties of unstable nuclei. The first on-line commissioning experiment of this system was performed using the continuous stable ($^{39}$K) and unstable ($^{38}$K) ion beams produced by im**ing a 100-MeV proton beam on a CaO target. Hyperfine structure spectra of these two isotopes are reasonably reproduced, and the extracted magnetic dipole hyperfine parameters and isotope shift agree with the literature values. The on-line experiment demonstrates the overall functioning of this CLS system, opening new opportunities for laser spectroscopy measurement of unstable isotopes at BRIF and other radioactive ion beam facilities in China.
△ Less
Submitted 11 March, 2022;
originally announced March 2022.
-
Property investigation for different wedge-shaped CsI(Tl)s
Authors:
G. Li,
J. L. Lou,
Y. L. Ye,
H. Hua,
H. Wang,
J. X. Han,
W. Liu,
S. W. Bai,
Z. W. Tan,
K. Ma,
J. H. Chen,
L. S. Yang,
S. J. Wang,
Z. Y. Hu,
H. Z. Yu,
H. Y. Zhu,
B. L. Xia,
Y. Jiang,
Y. Liu,
X. F. Yang,
Q. T. Li,
J. Y. Xu,
J. S. Wang,
Y. Y. Yang,
J. B. Ma
, et al. (10 additional authors not shown)
Abstract:
Two types of wedge-shaped CsI(Tl)s were designed to be placed behind the annular double-sided silicon detectors (ADSSDs) to identify the light charged particles with the $ΔE-E$ method. The properties of CsI(Tl)s with different shapes and sizes, such as energy resolution, light output non-uniformity and particle identification capability, were compared by using a $α$-source and a radioactive beam o…
▽ More
Two types of wedge-shaped CsI(Tl)s were designed to be placed behind the annular double-sided silicon detectors (ADSSDs) to identify the light charged particles with the $ΔE-E$ method. The properties of CsI(Tl)s with different shapes and sizes, such as energy resolution, light output non-uniformity and particle identification capability, were compared by using a $α$-source and a radioactive beam of $^{15}$C. The big-size CsI(Tl) was finally adopted to form the $ΔE-E$ telescope due to better properties. The property differences of these two types of CsI(Tl)s can be interpreted based on the Geant4 simulation results.
△ Less
Submitted 2 March, 2021;
originally announced March 2021.