Skip to main content

Showing 1–20 of 20 results for author: Walding, J

Searching in archive physics. Search in all archives.
.
  1. arXiv:2406.18597  [pdf, other

    physics.ins-det hep-ex

    Relative Measurement and Extrapolation of the Scintillation Quenching Factor of $α$-Particles in Liquid Argon using DEAP-3600 Data

    Authors: The DEAP Collaboration, P. Adhikari, M. Alpízar-Venegas, P. -A. Amaudruz, J. Anstey, D. J. Auty, M. Batygov, B. Beltran, C. E. Bina, W. Bonivento, M. G. Boulay, J. F. Bueno, B. Cai, M. Cárdenas-Montes, S. Choudhary, B. T. Cleveland, R. Crampton, S. Daugherty, P. DelGobbo, P. Di Stefano, G. Dolganov, L. Doria, F. A. Duncan, M. Dunford, E. Ellingwood , et al. (73 additional authors not shown)

    Abstract: The knowledge of scintillation quenching of $α$-particles plays a paramount role in understanding $α$-induced backgrounds and improving the sensitivity of liquid argon-based direct detection of dark matter experiments. We performed a relative measurement of scintillation quenching in the MeV energy region using radioactive isotopes ($^{222}$Rn, $^{218}$Po and $^{214}$Po isotopes) present in trace… ▽ More

    Submitted 12 June, 2024; originally announced June 2024.

    Comments: Submitted to Eur. Phys. J. C

  2. arXiv:2305.08822  [pdf, other

    physics.ins-det hep-ex

    First operation of an ALICE OROC operated in high pressure Ar-CO$_{2}$ and Ar-CH$_{4}$

    Authors: A. Ritchie-Yates, A. Deisting, G. Barker, S. Boyd, D. Brailsford, Z. Chen-Wishart, L. Cremonesi, P. Dunne, J. Eeles, P. Hamilton, A. C. Kaboth, N. Khan, A. Klustová, J. Monroe, J. Nowak, P. Singh, A. V. Waldron, J. Walding, L. Warsame, M. O. Wascko, I. Xiotidis

    Abstract: New neutrino-nucleus interaction cross-section measurements are required to improve nuclear models sufficiently for future long-baseline neutrino experiments to meet their sensitivity goals. A time projection chamber (TPC) filled with a high-pressure gas is a promising detector to characterise the neutrino sources planned for such experiments. A gas-filled TPC is ideal for measuring low-energy par… ▽ More

    Submitted 15 May, 2023; originally announced May 2023.

  3. arXiv:2302.14639  [pdf, other

    physics.ins-det hep-ex

    Precision Measurement of the Specific Activity of $^{39}$Ar in Atmospheric Argon with the DEAP-3600 Detector

    Authors: P. Adhikari, R. Ajaj, M. Alpízar-Venegas, P. -A. Amaudruz, J. Anstey, G. R. Araujo, D. J. Auty, M. Baldwin, M. Batygov, B. Beltran, H. Benmansour, C. E. Bina, J. Bonatt, W. Bonivento, M. G. Boulay, B. Broerman, J. F. Bueno, P. M. Burghardt, A. Butcher, M. Cadeddu, B. Cai, M. Cárdenas-Montes, S. Cavuoti, M. Chen, Y. Chen , et al. (125 additional authors not shown)

    Abstract: The specific activity of the beta decay of $^{39}$Ar in atmospheric argon is measured using the DEAP-3600 detector. DEAP-3600, located 2 km underground at SNOLAB, uses a total of (3269 $\pm$ 24) kg of liquid argon distilled from the atmosphere to search for dark matter. This detector with very low background uses pulseshape discrimination to differentiate between nuclear recoils and electron recoi… ▽ More

    Submitted 10 October, 2023; v1 submitted 27 February, 2023; originally announced February 2023.

    Journal ref: Eur. Phys. J. C 83, 642 (2023)

  4. arXiv:2206.11441  [pdf, other

    physics.comp-ph nucl-ex physics.ins-det

    Contextual Isotope Ranking Criteria for Peak Identification in Gamma Spectroscopy Using a Large Database

    Authors: Alexis Aguilar-Arevalo, Xavier Bertou, Carles Canet, Miguel A. Cruz-Pérez, Alexander Deisting, Adriana Dias, Juan Carlos D'Olivo, J. Francisco Favela-Pérez, Estela A. Garcés, Adiv González Muñoz, Jaime Octavio Guerra-Pulido, Javier Mancera-Alejandrez, Daniel José Marín-Lámbarri, Mauricio Martínez-Montero, Jocelyn Monroe, Sean Paling, Simon Peeters, Paul R. Scovell, Cenk Türkoglu, Eric Vázquez-Jáuregui, Joseph Walding

    Abstract: Isotope identification is a recurrent problem in gamma spectroscopy with high purity germanium detectors. In this work, new strategies are introduced to facilitate this type of analysis. Five criteria are used to identify the parent isotopes making a query on a large database of gamma-lines from a multitude of isotopes producing an output list whose entries are sorted so that the gamma-lines with… ▽ More

    Submitted 22 June, 2022; originally announced June 2022.

    Comments: 12 pages, 7 tables, 7 figures

    Journal ref: IEEE Transactions on Nuclear Science, 2022

  5. Volume reduction of water samples to increase sensitivity for radioassay of lead contamination

    Authors: A. Aguilar-Arevalo, C. Canet, M. A. Cruz-Pérez, A. Deisting, A. Dias, J. C. D'Olivo, F. Favela-Pérez, E. A. Garcés, A. González Muñoz, J. O. Guerra-Pulido, J. Mancera-Alejandrez, D. J. Marín-Lámbarri, M. Martinez Montero, J. R. Monroe, S. Paling, S. J. M. Peeters, P. R. Scovell, C. Türkoğlu, E. Vázquez-Jáuregui, J. Walding

    Abstract: The World Health Organisation (WHO) presents an upper limit for lead in drinking water of 10 parts per billion ppb. Typically, to reach this level of sensitivity, expensive metrology is required. To increase the sensitivity of low cost devices, this paper explores the prospects of using a volume reduction technique of a boiled water sample doped with Lead-210 ($^{210}Pb$), as a means to increase t… ▽ More

    Submitted 9 May, 2022; originally announced May 2022.

  6. arXiv:2103.12202  [pdf, other

    physics.ins-det astro-ph.IM

    Pulseshape discrimination against low-energy Ar-39 beta decays in liquid argon with 4.5 tonne-years of DEAP-3600 data

    Authors: The DEAP Collaboration, P. Adhikari, R. Ajaj, M. Alpízar-Venegas, P. -A. Amaudruz, D. J. Auty, M. Batygov, B. Beltran, H. Benmansour, C. E. Bina, J. Bonatt, W. Bonivento, M. G. Boulay, B. Broerman, J. F. Bueno, P. M. Burghardt, A. Butcher, M. Cadeddu, B. Cai, M. Cárdenas-Montes, S. Cavuoti, M. Chen, Y. Chen, B. T. Cleveland, J. M. Corning , et al. (104 additional authors not shown)

    Abstract: The DEAP-3600 detector searches for the scintillation signal from dark matter particles scattering on a 3.3 tonne liquid argon target. The largest background comes from $^{39}$Ar beta decays and is suppressed using pulseshape discrimination (PSD). We use two types of PSD algorithm: the prompt-fraction, which considers the fraction of the scintillation signal in a narrow and a wide time window ar… ▽ More

    Submitted 6 April, 2021; v1 submitted 22 March, 2021; originally announced March 2021.

    Comments: 14 pages, 9 figures

    Journal ref: Eur. Phys. J. C 81, 823 (2021)

  7. arXiv:2009.11757  [pdf, other

    physics.ins-det hep-ex nucl-ex

    Characterization of Germanium Detectors for the First Underground Laboratory in Mexico

    Authors: A. Aguilar-Arevalo, S. Alvarado-Mijangos, X. Bertou, C. Canet, M. A. Cruz-Pérez, A. Deisting, A. Dias, J. C. D'Olivo, F. Favela-Pérez, E. A. Garcés, A. González Muñoz, J. O. Guerra-Pulido, J. Mancera-Alejandrez, D. J. Marín-Lámbarri, M. Martínez Montero, J. Monroe, C. Iván Ortega-Hernández, S. Paling, S. Peeters, D. Ruíz Esparza Rodríguez, P. R. Scovell, C. Türkoğlu, E. Vázquez-Jáuregui, J. Walding

    Abstract: This article reports the characterization of two High Purity Germanium detectors performed by extracting and comparing their efficiencies using experimental data and Monte Carlo simulations. The efficiencies were calculated for pointlike $γ$-ray sources as well as for extended calibration sources. Characteristics of the detectors such as energy linearity, energy resolution, and full energy peak ef… ▽ More

    Submitted 24 September, 2020; originally announced September 2020.

    Comments: 18 pages, 13 figures

  8. arXiv:2009.11227  [pdf, other

    physics.ins-det physics.app-ph

    Dosimetry and calorimetry performance of a scientific CMOS camera for environmental monitoring

    Authors: Alexis Aguilar-Arevalo, Xavier Bertou, Carles Canet, Miguel Angel Cruz-Perez, Alexander Deisting, Adriana Dias, Juan Carlos D'Olivo, Francisco Favela-Perez, Estela A. Garces, Adiv Gonzalez Munoz, Jaime Octavio Guerra-Pulido, Javier Mancera-Alejandrez, Daniel Jose Marin-Lambarri, Mauricio Martinez Montero, Jocelyn Monroe, Sean Paling, Simon J. M. Peeters, Paul Scovell, Cenk Turkoglu, Eric Vazquez-Jauregui, Joseph Walding

    Abstract: This paper explores the prospect of CMOS devices to assay lead in drinking water, using calorimetry. Lead occurs together with traces of radioisotopes, e.g. Lead-210, producing $γ$-emissions with energies ranging from 10 keV to several 100 keV when they decay; this range is detectable in silicon sensors. In this paper we test a CMOS camera (Oxford Instruments Neo 5.5) for its general performance a… ▽ More

    Submitted 23 September, 2020; originally announced September 2020.

  9. arXiv:2004.02024  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    SiPM-matrix readout of two-phase argon detectors using electroluminescence in the visible and near infrared range

    Authors: The DarkSide collaboration, C. E. Aalseth, S. Abdelhakim, P. Agnes, R. Ajaj, I. F. M. Albuquerque, T. Alexander, A. Alici, A. K. Alton, P. Amaudruz, F. Ameli, J. Anstey, P. Antonioli, M. Arba, S. Arcelli, R. Ardito, I. J. Arnquist, P. Arpaia, D. M. Asner, A. Asunskis, M. Ave, H. O. Back, V. Barbaryan, A. Barrado Olmedo, G. Batignani , et al. (290 additional authors not shown)

    Abstract: Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The "standard" EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition, there are two alternative mechanisms, producing light in the… ▽ More

    Submitted 26 February, 2021; v1 submitted 4 April, 2020; originally announced April 2020.

    Comments: 26 pages, 22 figures, 3 tables

    Journal ref: Eur. Phys. J. C (2021) 81: 153

  10. The liquid-argon scintillation pulseshape in DEAP-3600

    Authors: The DEAP collaboration, P. Adhikari, R. Ajaj, G. R. Araujoand M. Batygov, B. Beltran, C. E. Bina, M. G. Boulay, B. Broerman, J. F. Bueno, A. Butcher, B. Cai, M. Cárdenas-Montes, S. Cavuoti, Y. Chen, B. T. Cleveland, J. M. Corning, S. J. Daughertyand K. Dering, L. Doria, F. A. Duncan andM. Dunford, A. Erlandson, N. Fatemighomi, G. Fiorillo, A. Flower, R. J. Ford, R. Gagnon , et al. (76 additional authors not shown)

    Abstract: DEAP-3600 is a liquid-argon scintillation detector looking for dark matter. Scintillation events in the liquid argon (LAr) are registered by 255 photomultiplier tubes (PMTs), and pulseshape discrimination (PSD) is used to suppress electromagnetic background events. The excellent PSD performance of LAr makes it a viable target for dark matter searches, and the LAr scintillation pulseshape discussed… ▽ More

    Submitted 8 June, 2020; v1 submitted 27 January, 2020; originally announced January 2020.

    Journal ref: Eur. Phys. J. C 80, 303 (2020)

  11. arXiv:2001.08106  [pdf, other

    astro-ph.IM physics.ins-det

    Design and construction of a new detector to measure ultra-low radioactive-isotope contamination of argon

    Authors: The DarkSide Collaboration, C. E. Aalseth, S. Abdelhakim, F. Acerbi, P. Agnes, R. Ajaj, I. F. M. Albuquerque, T. Alexander, A. Alici, A. K. Alton, P. Amaudruz, F. Ameli, J. Anstey, P. Antonioli, M. Arba, S. Arcelli, R. Ardito, I. J. Arnquist, P. Arpaia, D. M. Asner, A. Asunskis, M. Ave, H. O. Back, A. Barrado Olmedo, G. Batignani , et al. (306 additional authors not shown)

    Abstract: Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioa… ▽ More

    Submitted 22 January, 2020; originally announced January 2020.

    Comments: 13 pages, 8 figures. Corresponding author: E. Sánchez García

  12. arXiv:1805.04163  [pdf, other

    physics.ins-det astro-ph.SR hep-ex

    Hyper-Kamiokande Design Report

    Authors: Hyper-Kamiokande Proto-Collaboration, :, K. Abe, Ke. Abe, H. Aihara, A. Aimi, R. Akutsu, C. Andreopoulos, I. Anghel, L. H. V. Anthony, M. Antonova, Y. Ashida, V. Aushev, M. Barbi, G. J. Barker, G. Barr, P. Beltrame, V. Berardi, M. Bergevin, S. Berkman, L. Berns, T. Berry, S. Bhadra, D. Bravo-Berguño, F. d. M. Blaszczyk , et al. (291 additional authors not shown)

    Abstract: On the strength of a double Nobel prize winning experiment (Super)Kamiokande and an extremely successful long baseline neutrino programme, the third generation Water Cherenkov detector, Hyper-Kamiokande, is being developed by an international collaboration as a leading worldwide experiment based in Japan. The Hyper-Kamiokande detector will be hosted in the Tochibora mine, about 295 km away from th… ▽ More

    Submitted 28 November, 2018; v1 submitted 9 May, 2018; originally announced May 2018.

    Comments: 325 pages

  13. DarkSide-20k: A 20 Tonne Two-Phase LAr TPC for Direct Dark Matter Detection at LNGS

    Authors: C. E. Aalseth, F. Acerbi, P. Agnes, I. F. M. Albuquerque, T. Alexander, A. Alici, A. K. Alton, P. Antonioli, S. Arcelli, R. Ardito, I. J. Arnquist, D. M. Asner, M. Ave, H. O. Back, A. I. Barrado Olmedo, G. Batignani, E. Bertoldo, S. Bettarini, M. G. Bisogni, V. Bocci, A. Bondar, G. Bonfini, W. Bonivento, M. Bossa, B. Bottino , et al. (260 additional authors not shown)

    Abstract: Building on the successful experience in operating the DarkSide-50 detector, the DarkSide Collaboration is going to construct DarkSide-20k, a direct WIMP search detector using a two-phase Liquid Argon Time Projection Chamber (LArTPC) with an active (fiducial) mass of 23 t (20 t). The DarkSide-20k LArTPC will be deployed within a shield/veto with a spherical Liquid Scintillator Veto (LSV) inside a… ▽ More

    Submitted 25 July, 2017; originally announced July 2017.

    Report number: FERMILAB-PUB-17-298-PPD

    Journal ref: Aalseth, C.E., Acerbi, F., Agnes, P. et al. Eur. Phys. J. Plus (2018) 133: 131

  14. In-situ characterization of the Hamamatsu R5912-HQE photomultiplier tubes used in the DEAP-3600 experiment

    Authors: DEAP Collaboration, P. -A. Amaudruz, M. Batygov, B. Beltran, C. E. Bina, D. Bishop, J. Bonatt, G. Boorman, M. G. Boulay, B. Broerman, T. Bromwich, J. F. Bueno, A. Butcher, B. Cai, S. Chan, M. Chen, R. Chouinard, S. Churchwell, B. T. Cleveland, D. Cranshaw, K. Dering, S. Dittmeier, F. A. Duncan, M. Dunford, A. Erlandson , et al. (77 additional authors not shown)

    Abstract: The Hamamatsu R5912-HQE photomultiplier-tube (PMT) is a novel high-quantum efficiency PMT. It is currently used in the DEAP-3600 dark matter detector and is of significant interest for future dark matter and neutrino experiments where high signal yields are needed. We report on the methods developed for in-situ characterization and monitoring of DEAP's 255 R5912-HQE PMTs. This includes a detaile… ▽ More

    Submitted 29 January, 2019; v1 submitted 29 May, 2017; originally announced May 2017.

    Journal ref: Nucl. Instrum. Methods Phys. Res. A 922, 373-384 (2019)

  15. A method for characterizing after-pulsing and dark noise of PMTs and SiPMs

    Authors: A. Butcher, L. Doria, J. Monroe, F. Retiere, B. Smith, J. Walding

    Abstract: Photo-multiplier tubes (PMTs) and silicon photo-multipliers (SiPMs) are detectors sensitive to single photons that are widely used for the detection of scintillation and Cerenkov light in subatomic physics and medical imaging. This paper presents a method for characterizing two of the main noise sources that PMTs and SiPMs share: dark noise and correlated noise (after-pulsing). The proposed method… ▽ More

    Submitted 21 August, 2017; v1 submitted 17 March, 2017; originally announced March 2017.

    Comments: Accepted by Nucl. Instr. Meth. A. 11 pages, 8 figures. Added application of method to SiPM data in new version

  16. arXiv:1611.06118  [pdf, other

    hep-ex hep-ph physics.ins-det

    Physics Potentials with the Second Hyper-Kamiokande Detector in Korea

    Authors: Hyper-Kamiokande proto-collaboration, :, K. Abe, Ke. Abe, S. H. Ahn, H. Aihara, A. Aimi, R. Akutsu, C. Andreopoulos, I. Anghel, L. H. V. Anthony, M. Antonova, Y. Ashida, V. Aushev, M. Barbi, G. J. Barker, G. Barr, P. Beltrame, V. Berardi, M. Bergevin, S. Berkman, L. Berns, T. Berry, S. Bhadra, D. Bravo-Bergu no , et al. (331 additional authors not shown)

    Abstract: Hyper-Kamiokande consists of two identical water-Cherenkov detectors of total 520~kt with the first one in Japan at 295~km from the J-PARC neutrino beam with 2.5$^{\textrm{o}}$ Off-Axis Angles (OAAs), and the second one possibly in Korea in a later stage. Having the second detector in Korea would benefit almost all areas of neutrino oscillation physics mainly due to longer baselines. There are sev… ▽ More

    Submitted 26 March, 2018; v1 submitted 18 November, 2016; originally announced November 2016.

    Comments: 102 pages, 49 figures. Accepted by PTEP

    Journal ref: Prog Theor Exp Phys (2018)

  17. arXiv:1410.7673  [pdf, other

    physics.ins-det astro-ph.CO astro-ph.IM hep-ex

    DEAP-3600 Dark Matter Search

    Authors: DEAP Collaboration, P. -A. Amaudruz, M. Batygov, B. Beltran, J. Bonatt, M. G. Boulay, B. Broerman, J. F. Bueno, A. Butcher, B. Cai, M. Chen, R. Chouinard, B. T. Cleveland, K. Dering, J. DiGioseffo, F. Duncan, T. Flower, R. Ford, P. Giampa, P. Gorel, K. Graham, D. R. Grant, E. Guliyev, A. L. Hallin, M. Hamstra , et al. (32 additional authors not shown)

    Abstract: The DEAP-3600 experiment is located 2 km underground at SNOLAB, in Sudbury, Ontario. It is a single-phase detector that searches for dark matter particle interactions within a 1000-kg fiducial mass target of liquid argon. A first generation prototype detector (DEAP-1) with a 7-kg liquid argon target mass demonstrated a high level of pulse-shape discrimination (PSD) for reducing $β$/$γ$ backgrounds… ▽ More

    Submitted 25 August, 2015; v1 submitted 27 October, 2014; originally announced October 2014.

    Comments: International Conference on High Energy Physics (ICHEP 2014), Valencia, 2014

    Journal ref: Nuclear and Particle Physics Proceedings 273-275 (2016) 340-346

  18. arXiv:1408.1914  [pdf, other

    physics.ins-det astro-ph.IM hep-ex nucl-ex

    Improving Photoelectron Counting and Particle Identification in Scintillation Detectors with Bayesian Techniques

    Authors: M. Akashi-Ronquest, P. -A. Amaudruz, M. Batygov, B. Beltran, M. Bodmer, M. G. Boulay, B. Broerman, B. Buck, A. Butcher, B. Cai, T. Caldwell, M. Chen, Y. Chen, B. Cleveland, K. Coakley, K. Dering, F. A. Duncan, J. A. Formaggio, R. Gagnon, D. Gastler, F. Giuliani, M. Gold, V. V. Golovko, P. Gorel, K. Graham , et al. (57 additional authors not shown)

    Abstract: Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and particle identification capabilities of these detectors depend in part on the ability to accurately identify individual photoelectrons in PMT waveforms despite large variability in pulse amplitudes and pulse pileup. We… ▽ More

    Submitted 12 December, 2014; v1 submitted 8 August, 2014; originally announced August 2014.

    Comments: 16 pages, 16 figures

  19. arXiv:1403.4842  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Update on the MiniCLEAN Dark Matter Experiment

    Authors: K. Rielage, M. Akashi-Ronquest, M. Bodmer, R. Bourque, B. Buck, A. Butcher, T. Caldwell, Y. Chen, K. Coakley, E. Flores, J. A. Formaggio, D. Gastler, F. Giuliani, M. Gold, E. Grace, J. Griego, N. Guerrero, V. Guiseppe, R. Henning, A. Hime, S. Jaditz, C. Kachulis, E. Kearns, J. Kelsey, J. R. Klein , et al. (21 additional authors not shown)

    Abstract: The direct search for dark matter is entering a period of increased sensitivity to the hypothetical Weakly Interacting Massive Particle (WIMP). One such technology that is being examined is a scintillation only noble liquid experiment, MiniCLEAN. MiniCLEAN utilizes over 500 kg of liquid cryogen to detect nuclear recoils from WIMP dark matter and serves as a demonstration for a future detector of o… ▽ More

    Submitted 19 March, 2014; originally announced March 2014.

    Comments: To appear in the Proceedings of the TAUP 2013 Conference (F. Avignone & W. Haxton, editors, Physics Procedia, Elsevier)

    Report number: LA-UR-14-21626

  20. Measurements of the T2K neutrino beam properties using the INGRID on-axis near detector

    Authors: K. Abe, N. Abgrall, Y. Ajima, H. Aihara, J. B. Albert, C. Andreopoulos, B. Andrieu, M. D. Anerella, S. Aoki, O. Araoka, J. Argyriades, A. Ariga, T. Ariga, S. Assylbekov, D. Autiero, A. Badertscher, M. Barbi, G. J. Barker, G. Barr, M. Bass, M. Batkiewicz, F. Bay, S. Bentham, V. Berardi, B. E. Berger , et al. (407 additional authors not shown)

    Abstract: Precise measurement of neutrino beam direction and intensity was achieved based on a new concept with modularized neutrino detectors. INGRID (Interactive Neutrino GRID) is an on-axis near detector for the T2K long baseline neutrino oscillation experiment. INGRID consists of 16 identical modules arranged in horizontal and vertical arrays around the beam center. The module has a sandwich structure o… ▽ More

    Submitted 14 November, 2011; originally announced November 2011.

    Comments: 32 pages, 27 figures, submitted to Nucl. Instr. and Meth. A