-
From the digital twins in healthcare to the Virtual Human Twin: a moon-shot project for digital health research
Authors:
Marco Viceconti,
Maarten De Vos,
Sabato Mellone,
Liesbet Geris
Abstract:
The idea of a systematic digital representation of the entire known human pathophysiology, which we could call the Virtual Human Twin, has been around for decades. To date, most research groups focused instead on develo** highly specialised, highly focused patient-specific models able to predict specific quantities of clinical relevance. While it has facilitated harvesting the low-hanging fruits…
▽ More
The idea of a systematic digital representation of the entire known human pathophysiology, which we could call the Virtual Human Twin, has been around for decades. To date, most research groups focused instead on develo** highly specialised, highly focused patient-specific models able to predict specific quantities of clinical relevance. While it has facilitated harvesting the low-hanging fruits, this narrow focus is, in the long run, leaving some significant challenges that slow the adoption of digital twins in healthcare. This position paper lays the conceptual foundations for develo** the Virtual Human Twin (VHT). The VHT is intended as a distributed and collaborative infrastructure, a collection of technologies and resources (data, models) that enable it, and a collection of Standard Operating Procedures (SOP) that regulate its use. The VHT infrastructure aims to facilitate academic researchers, public organisations, and the biomedical industry in develo** and validating new digital twins in healthcare solutions with the possibility of integrating multiple resources if required by the specific context of use. Healthcare professionals and patients can also use the VHT infrastructure for clinical decision support or personalised health forecasting. As the European Commission launched the EDITH coordination and support action to develop a roadmap for the development of the Virtual Human Twin, this position paper is intended as a starting point for the consensus process and a call to arms for all stakeholders.
△ Less
Submitted 12 August, 2023; v1 submitted 27 March, 2023;
originally announced April 2023.
-
The International Linear Collider: Report to Snowmass 2021
Authors:
Alexander Aryshev,
Ties Behnke,
Mikael Berggren,
James Brau,
Nathaniel Craig,
Ayres Freitas,
Frank Gaede,
Spencer Gessner,
Stefania Gori,
Christophe Grojean,
Sven Heinemeyer,
Daniel Jeans,
Katja Kruger,
Benno List,
Jenny List,
Zhen Liu,
Shinichiro Michizono,
David W. Miller,
Ian Moult,
Hitoshi Murayama,
Tatsuya Nakada,
Emilio Nanni,
Mihoko Nojiri,
Hasan Padamsee,
Maxim Perelstein
, et al. (487 additional authors not shown)
Abstract:
The International Linear Collider (ILC) is on the table now as a new global energy-frontier accelerator laboratory taking data in the 2030s. The ILC addresses key questions for our current understanding of particle physics. It is based on a proven accelerator technology. Its experiments will challenge the Standard Model of particle physics and will provide a new window to look beyond it. This docu…
▽ More
The International Linear Collider (ILC) is on the table now as a new global energy-frontier accelerator laboratory taking data in the 2030s. The ILC addresses key questions for our current understanding of particle physics. It is based on a proven accelerator technology. Its experiments will challenge the Standard Model of particle physics and will provide a new window to look beyond it. This document brings the story of the ILC up to date, emphasizing its strong physics motivation, its readiness for construction, and the opportunity it presents to the US and the global particle physics community.
△ Less
Submitted 16 January, 2023; v1 submitted 14 March, 2022;
originally announced March 2022.
-
Assessment of Data Consistency through Cascades of Independently Recurrent Inference Machines for fast and robust accelerated MRI reconstruction
Authors:
D. Karkalousos,
S. Noteboom,
H. E. Hulst,
F. M. Vos,
M. W. A. Caan
Abstract:
Machine Learning methods can learn how to reconstruct Magnetic Resonance Images and thereby accelerate acquisition, which is of paramount importance to the clinical workflow. Physics-informed networks incorporate the forward model of accelerated MRI reconstruction in the learning process. With increasing network complexity, robustness is not ensured when reconstructing data unseen during training.…
▽ More
Machine Learning methods can learn how to reconstruct Magnetic Resonance Images and thereby accelerate acquisition, which is of paramount importance to the clinical workflow. Physics-informed networks incorporate the forward model of accelerated MRI reconstruction in the learning process. With increasing network complexity, robustness is not ensured when reconstructing data unseen during training. We aim to embed data consistency (DC) in deep networks while balancing the degree of network complexity. While doing so, we will assess whether either explicit or implicit enforcement of DC in varying network architectures is preferred to optimize performance. We propose a scheme called Cascades of Independently Recurrent Inference Machines (CIRIM) to assess DC through unrolled optimization. Herein we assess DC both implicitly by gradient descent and explicitly by a designed term. Extensive comparison of the CIRIM to CS as well as to other methods is performed: the E2EVN, CascadeNet, KIKINet, LPDNet, RIM, IRIM, and UNet. Models were trained and evaluated on T1-weighted and FLAIR contrast brain data, and T2-weighted knee data. Both 1D and 2D undersampling patterns were evaluated. Robustness was tested by reconstructing 7.5x prospectively undersampled 3D FLAIR MRI data of Multiple Sclerosis (MS) patients with white matter lesions. The CIRIM performed best when implicitly enforcing DC, while the E2EVN required an explicit DC formulation. In reconstructing MS patient data, prospectively acquired with a sampling pattern unseen during model training, the CIRIM maintained lesion contrast while efficiently denoising the images. The CIRIM showed highly promising generalization capabilities maintaining a very fair trade-off between reconstructed image quality and fast reconstruction times, which is crucial in the clinical workflow.
△ Less
Submitted 4 April, 2022; v1 submitted 30 November, 2021;
originally announced November 2021.
-
An Efficient Method for Multi-Parameter Map** in Quantitative MRI using B-Spline Interpolation
Authors:
Willem van Valenberg,
Stefan Klein,
Frans M. Vos,
Kirsten Koolstra,
Lucas J. van Vliet,
Dirk H. J. Poot
Abstract:
Quantitative MRI methods that estimate multiple physical parameters simultaneously often require the fitting of a computational complex signal model defined through the Bloch equations. Repeated Bloch simulations can be avoided by matching the measured signal with a precomputed signal dictionary on a discrete parameter grid, as used in MR Fingerprinting. However, accurate estimation requires discr…
▽ More
Quantitative MRI methods that estimate multiple physical parameters simultaneously often require the fitting of a computational complex signal model defined through the Bloch equations. Repeated Bloch simulations can be avoided by matching the measured signal with a precomputed signal dictionary on a discrete parameter grid, as used in MR Fingerprinting. However, accurate estimation requires discretizing each parameter with a high resolution and consequently high computational and memory costs for dictionary generation, storage, and matching. Here, we reduce the required parameter resolution by approximating the signal between grid points through B-spline interpolation. The interpolant and its gradient are evaluated efficiently which enables a least-squares fitting method for parameter map**. The resolution of each parameter was minimized while obtaining a user-specified interpolation accuracy. The method was evaluated by phantom and in-vivo experiments using fully-sampled and undersampled unbalanced (FISP) MR fingerprinting acquisitions. Bloch simulations incorporated relaxation effects ($T_1,T_2$), proton density ($PD$), receiver phase ($φ_0$), transmit field inhomogeneity ($B_1^+$), and slice profile. Parameter maps were compared with those obtained from dictionary matching, where the parameter resolution was chosen to obtain similar signal (interpolation) accuracy. For both the phantom and the in-vivo acquisition, the proposed method approximated the parameter maps obtained through dictionary matching while reducing the parameter resolution in each dimension ($T_1,T_2,B_1^+$) by, on average, an order of magnitude. In effect, the applied dictionary was reduced from 1.47 GB to 464 KB. Dictionary fitting with B-spline interpolation reduces the computational and memory costs of dictionary-based methods and is therefore a promising method for multi-parametric map**.
△ Less
Submitted 18 November, 2019;
originally announced November 2019.
-
High-resolution conversion electron spectroscopy of the 125I electron-capture decay
Authors:
B. P. E. Tee,
A. E. Stuchbery,
M. Vos,
J. T. H. Dowie,
B. Q. Lee,
M. Alotiby,
I. Greguric,
T. Kibedi
Abstract:
The conversion electrons from the decay of the 35.5-keV excited state of 125Te following the electron capture decay of 125I have been investigated at high resolution using an electrostatic spectrometer. The penetration parameter lambda = -1.2(6) and mixing ratio |delta| = 0.015(2) were deduced by fitting to literature values and present data. The shake probability of the conversion electrons is es…
▽ More
The conversion electrons from the decay of the 35.5-keV excited state of 125Te following the electron capture decay of 125I have been investigated at high resolution using an electrostatic spectrometer. The penetration parameter lambda = -1.2(6) and mixing ratio |delta| = 0.015(2) were deduced by fitting to literature values and present data. The shake probability of the conversion electrons is estimated to be 0.5, more than two times larger than the predicted value of 0.2.
△ Less
Submitted 3 September, 2019;
originally announced September 2019.
-
Detector Technologies for CLIC
Authors:
A. C. Abusleme Hoffman,
G. Parès,
T. Fritzsch,
M. Rothermund,
H. Jansen,
K. Krüger,
F. Sefkow,
A. Velyka,
J. Schwandt,
I. Perić,
L. Emberger,
C. Graf,
A. Macchiolo,
F. Simon,
M. Szalay,
N. van der Kolk,
H. Abramowicz,
Y. Benhammou,
O. Borysov,
M. Borysova,
A. Joffe,
S. Kananov,
A. Levy,
I. Levy,
G. Eigen
, et al. (107 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a high-energy high-luminosity linear electron-positron collider under development. It is foreseen to be built and operated in three stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. It offers a rich physics program including direct searches as well as the probing of new physics through a broad set of precision measurements of Stan…
▽ More
The Compact Linear Collider (CLIC) is a high-energy high-luminosity linear electron-positron collider under development. It is foreseen to be built and operated in three stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. It offers a rich physics program including direct searches as well as the probing of new physics through a broad set of precision measurements of Standard Model processes, particularly in the Higgs-boson and top-quark sectors. The precision required for such measurements and the specific conditions imposed by the beam dimensions and time structure put strict requirements on the detector design and technology. This includes low-mass vertexing and tracking systems with small cells, highly granular imaging calorimeters, as well as a precise hit-time resolution and power-pulsed operation for all subsystems. A conceptual design for the CLIC detector system was published in 2012. Since then, ambitious R&D programmes for silicon vertex and tracking detectors, as well as for calorimeters have been pursued within the CLICdp, CALICE and FCAL collaborations, addressing the challenging detector requirements with innovative technologies. This report introduces the experimental environment and detector requirements at CLIC and reviews the current status and future plans for detector technology R&D.
△ Less
Submitted 7 May, 2019;
originally announced May 2019.
-
The International Linear Collider: A Global Project
Authors:
Philip Bambade,
Tim Barklow,
Ties Behnke,
Mikael Berggren,
James Brau,
Philip Burrows,
Dmitri Denisov,
Angeles Faus-Golfe,
Brian Foster,
Keisuke Fujii,
Juan Fuster,
Frank Gaede,
Paul Grannis,
Christophe Grojean,
Andrew Hutton,
Benno List,
Jenny List,
Shinichiro Michizono,
Akiya Miyamoto,
Olivier Napoly,
Michael Peskin,
Roman Poeschl,
Frank Simon,
Jan Strube,
Jun** Tian
, et al. (7 additional authors not shown)
Abstract:
The International Linear Collider (ILC) is now under consideration as the next global project in particle physics. In this report, we review of all aspects of the ILC program: the physics motivation, the accelerator design, the run plan, the proposed detectors, the experimental measurements on the Higgs boson, the top quark, the couplings of the W and Z bosons, and searches for new particles. We r…
▽ More
The International Linear Collider (ILC) is now under consideration as the next global project in particle physics. In this report, we review of all aspects of the ILC program: the physics motivation, the accelerator design, the run plan, the proposed detectors, the experimental measurements on the Higgs boson, the top quark, the couplings of the W and Z bosons, and searches for new particles. We review the important role that polarized beams play in the ILC program. The first stage of the ILC is planned to be a Higgs factory at 250 GeV in the centre of mass. Energy upgrades can naturally be implemented based on the concept of a linear collider. We discuss in detail the ILC program of Higgs boson measurements and the expected precision in the determination of Higgs couplings. We compare the ILC capabilities to those of the HL-LHC and to those of other proposed e+e- Higgs factories. We emphasize throughout that the readiness of the accelerator and the estimates of ILC performance are based on detailed simulations backed by extensive RandD and, for the accelerator technology, operational experience.
△ Less
Submitted 5 April, 2019; v1 submitted 4 March, 2019;
originally announced March 2019.
-
The International Linear Collider. A Global Project
Authors:
Hiroaki Aihara,
Jonathan Bagger,
Philip Bambade,
Barry Barish,
Ties Behnke,
Alain Bellerive,
Mikael Berggren,
James Brau,
Martin Breidenbach,
Ivanka Bozovic-Jelisavcic,
Philip Burrows,
Massimo Caccia,
Paul Colas,
Dmitri Denisov,
Gerald Eigen,
Lyn Evans,
Angeles Faus-Golfe,
Brian Foster,
Keisuke Fujii,
Juan Fuster,
Frank Gaede,
Jie Gao,
Paul Grannis,
Christophe Grojean,
Andrew Hutton
, et al. (37 additional authors not shown)
Abstract:
A large, world-wide community of physicists is working to realise an exceptional physics program of energy-frontier, electron-positron collisions with the International Linear Collider (ILC). This program will begin with a central focus on high-precision and model-independent measurements of the Higgs boson couplings. This method of searching for new physics beyond the Standard Model is orthogonal…
▽ More
A large, world-wide community of physicists is working to realise an exceptional physics program of energy-frontier, electron-positron collisions with the International Linear Collider (ILC). This program will begin with a central focus on high-precision and model-independent measurements of the Higgs boson couplings. This method of searching for new physics beyond the Standard Model is orthogonal to and complements the LHC physics program. The ILC at 250 GeV will also search for direct new physics in exotic Higgs decays and in pair-production of weakly interacting particles. Polarised electron and positron beams add unique opportunities to the physics reach. The ILC can be upgraded to higher energy, enabling precision studies of the top quark and measurement of the top Yukawa coupling and the Higgs self-coupling. The key accelerator technology, superconducting radio-frequency cavities, has matured. Optimised collider and detector designs, and associated physics analyses, were presented in the ILC Technical Design Report, signed by 2400 scientists. There is a strong interest in Japan to host this international effort. A detailed review of the many aspects of the project is nearing a conclusion in Japan. Now the Japanese government is preparing for a decision on the next phase of international negotiations, that could lead to a project start within a few years. The potential timeline of the ILC project includes an initial phase of about 4 years to obtain international agreements, complete engineering design and prepare construction, and form the requisite international collaboration, followed by a construction phase of 9 years.
△ Less
Submitted 28 January, 2019;
originally announced January 2019.
-
The International Linear Collider. A European Perspective
Authors:
Philip Bambade,
Ties Behnke,
Mikael Berggren,
Ivanka Bozovic-Jelisavcic,
Philip Burrows,
Massimo Caccia,
Paul Colas,
Gerald Eigen,
Lyn Evans,
Angeles Faus-Golfe,
Brian Foster,
Juan Fuster,
Frank Gaede,
Christophe Grojean,
Marek Idzik,
Andrea Jeremie,
Tadeusz Lesiak,
Aharon Levy,
Benno List,
Jenny List,
Joachim Mnich,
Olivier Napoly,
Carlo Pagani,
Roman Poeschl,
Francois Richard
, et al. (9 additional authors not shown)
Abstract:
The International Linear Collider (ILC) being proposed in Japan is an electron-positron linear collider with an initial energy of 250 GeV. The ILC accelerator is based on the technology of superconducting radio-frequency cavities. This technology has reached a mature stage in the European XFEL project and is now widely used. The ILC will start by measuring the Higgs properties, providing high-prec…
▽ More
The International Linear Collider (ILC) being proposed in Japan is an electron-positron linear collider with an initial energy of 250 GeV. The ILC accelerator is based on the technology of superconducting radio-frequency cavities. This technology has reached a mature stage in the European XFEL project and is now widely used. The ILC will start by measuring the Higgs properties, providing high-precision and model-independent determinations of its parameters. The ILC at 250 GeV will also search for direct new physics in exotic Higgs decays and in pair-production of weakly interacting particles. The use of polarised electron and positron beams opens new capabilities and scenarios that add to the physics reach. The ILC can be upgraded to higher energy, enabling precision studies of the top quark and measurement of the top Yukawa coupling and the Higgs self-coupling. The international -- including European -- interest for the project is very strong. Europe has participated in the ILC project since its early conception and plays a major role in its present development covering most of its scientific and technological aspects: physics studies, accelerator and detectors. The potential for a wide participation of European groups and laboratories is thus high, including important opportunities for European industry. Following decades of technical development, R&D, and design optimisation, the project is ready for construction and the European particle physics community, technological centers and industry are prepared to participate in this challenging endeavour.
△ Less
Submitted 28 January, 2019;
originally announced January 2019.
-
Quantitative electron spectroscopy of $^{125}$I over an extended energy range
Authors:
M. Alotiby,
I Greguric,
T. Kibedi,
I Greguric,
B. Tee,
M. Vos
Abstract:
Auger electrons emitted after nuclear decay have potential application in targeted cancer therapy. For this purpose it is important to know the Auger electron yield per nuclear decay. In this work we measure the ratio of the number of conversion electrons (emitted as part of the nuclear decay process) and the number of Auger electrons (emitted as part of the atomic relaxation process after the nuc…
▽ More
Auger electrons emitted after nuclear decay have potential application in targeted cancer therapy. For this purpose it is important to know the Auger electron yield per nuclear decay. In this work we measure the ratio of the number of conversion electrons (emitted as part of the nuclear decay process) and the number of Auger electrons (emitted as part of the atomic relaxation process after the nuclear decay) for the case of $^{125}$I. Results are compared with Monte-Carlo type simulations of the relaxation cascade using the BrIccEmis code. With the appropriate choice of parameters this program describes the observed spectra quite well over the whole energy range.
△ Less
Submitted 10 January, 2019;
originally announced January 2019.
-
The Compact Linear Collider (CLIC) - 2018 Summary Report
Authors:
The CLIC,
CLICdp collaborations,
:,
T. K. Charles,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
M. Volpi,
C. Balazs,
K. Afanaciev,
V. Makarenko,
A. Patapenka,
I. Zhuk,
C. Collette,
M. J. Boland,
A. C. Abusleme Hoffman,
M. A. Diaz,
F. Garay,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu,
X. Wang,
J. Zhang
, et al. (671 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the…
▽ More
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the detector. CLIC is foreseen to be built and operated in stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. CLIC uses a two-beam acceleration scheme, in which 12 GHz accelerating structures are powered via a high-current drive beam. For the first stage, an alternative with X-band klystron powering is also considered. CLIC accelerator optimisation, technical developments and system tests have resulted in an increased energy efficiency (power around 170 MW) for the 380 GeV stage, together with a reduced cost estimate at the level of 6 billion CHF. The detector concept has been refined using improved software tools. Significant progress has been made on detector technology developments for the tracking and calorimetry systems. A wide range of CLIC physics studies has been conducted, both through full detector simulations and parametric studies, together providing a broad overview of the CLIC physics potential. Each of the three energy stages adds cornerstones of the full CLIC physics programme, such as Higgs width and couplings, top-quark properties, Higgs self-coupling, direct searches, and many precision electroweak measurements. The interpretation of the combined results gives crucial and accurate insight into new physics, largely complementary to LHC and HL-LHC. The construction of the first CLIC energy stage could start by 2026. First beams would be available by 2035, marking the beginning of a broad CLIC physics programme spanning 25-30 years.
△ Less
Submitted 6 May, 2019; v1 submitted 14 December, 2018;
originally announced December 2018.
-
Measurement of the intensity ratio of Auger and conversion electrons for the electron capture decay of $^{125}$I
Authors:
M. Alotiby,
I. Greguric,
T. Kibédi,
B. Q. Lee,
M. Roberts,
A. E. Stuchbery,
Pi Tee,
T. Tornyi,
M. Vos
Abstract:
Auger electrons emitted after nuclear decay have potential application in targeted cancer therapy. For this purpose it is important to know the Auger electron yield per nuclear decay. In this work we describe a measurement of the ratio of the number of conversion electrons (emitted as part of the nuclear decay process) to the number of Auger electrons (emitted as part of the atomic relaxation proc…
▽ More
Auger electrons emitted after nuclear decay have potential application in targeted cancer therapy. For this purpose it is important to know the Auger electron yield per nuclear decay. In this work we describe a measurement of the ratio of the number of conversion electrons (emitted as part of the nuclear decay process) to the number of Auger electrons (emitted as part of the atomic relaxation process after the nuclear decay) for the case of $^{125}$I. Results are compared with Monte-Carlo type simulations of the relaxation cascade using the BrIccEmis code. Our results indicate that for $^{125}$I the calculations based on rates from the Evaluated Atomic Data Library (EADL) underestimate the K Auger yields by 20\%.
△ Less
Submitted 3 March, 2018; v1 submitted 12 February, 2018;
originally announced February 2018.
-
Updated baseline for a staged Compact Linear Collider
Authors:
The CLIC,
CLICdp collaborations,
:,
M. J. Boland,
U. Felzmann,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
C. Balazs,
T. K. Charles,
K. Afanaciev,
I. Emeliantchik,
A. Ignatenko,
V. Makarenko,
N. Shumeiko,
A. Patapenka,
I. Zhuk,
A. C. Abusleme Hoffman,
M. A. Diaz Gutierrez,
M. Vogel Gonzalez,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu
, et al. (493 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-q…
▽ More
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-quark measurements. Subsequent stages will focus on measurements of rare Higgs processes, as well as searches for new physics processes and precision measurements of new states, e.g. states previously discovered at LHC or at CLIC itself. In the 2012 CLIC Conceptual Design Report, a fully optimised 3 TeV collider was presented, while the proposed lower energy stages were not studied to the same level of detail. This report presents an updated baseline staging scenario for CLIC. The scenario is the result of a comprehensive study addressing the performance, cost and power of the CLIC accelerator complex as a function of centre-of-mass energy and it targets optimal physics output based on the current physics landscape. The optimised staging scenario foresees three main centre-of-mass energy stages at 380 GeV, 1.5 TeV and 3 TeV for a full CLIC programme spanning 22 years. For the first stage, an alternative to the CLIC drive beam scheme is presented in which the main linac power is produced using X-band klystrons.
△ Less
Submitted 27 March, 2017; v1 submitted 26 August, 2016;
originally announced August 2016.
-
Integrated cooling channels in position-sensitive silicon detectors
Authors:
L. Andricek,
M. Boronat,
J. Fuster,
I. Garcia,
P. Gomis,
C. Marinas,
J. Ninkovic,
M. Perello Rosello,
M. A. Villarejo,
M. Vos
Abstract:
We present an approach to construct position-sensitive silicon detectors with an integrated cooling circuit. Tests on samples demonstrate that a very modest liquid flow very effectively cool the devices up to a power dissipation of over 10~W/cm$^2$. The liquid flow is found to have a negligible impact on the mechanical performance. A finite-element simulation predicts the cooling performance to an…
▽ More
We present an approach to construct position-sensitive silicon detectors with an integrated cooling circuit. Tests on samples demonstrate that a very modest liquid flow very effectively cool the devices up to a power dissipation of over 10~W/cm$^2$. The liquid flow is found to have a negligible impact on the mechanical performance. A finite-element simulation predicts the cooling performance to an accuracy of approximately 10~\%.
△ Less
Submitted 13 May, 2016; v1 submitted 29 April, 2016;
originally announced April 2016.
-
Physical limitations to the spatial resolution of solid-state detectors
Authors:
M. Boronat,
C. Marinas,
A. Frey,
I. Garcia,
B. Schwenker,
M. Vos,
F. Wilk
Abstract:
In this paper we explore the effect of $δ$-ray emission, fluctuations in th e signal deposition on the detection of charged particles in silicon-based detec tors. We show that these two effects ultimately limit the resolution that can be achieved by interpolation of the signal in finely segmented position-sensitive solid-state devices.
In this paper we explore the effect of $δ$-ray emission, fluctuations in th e signal deposition on the detection of charged particles in silicon-based detec tors. We show that these two effects ultimately limit the resolution that can be achieved by interpolation of the signal in finely segmented position-sensitive solid-state devices.
△ Less
Submitted 10 November, 2014; v1 submitted 17 April, 2014;
originally announced April 2014.
-
The brightness and spatial distributions of terrestrial radio sources
Authors:
A. R. Offringa,
A. G. de Bruyn,
S. Zaroubi,
L. V. E. Koopmans,
S. J. Wijnholds,
F. B. Abdalla,
W. N. Brouw,
B. Ciardi,
I. T. Iliev,
G. J. A. Harker,
G. Mellema,
G. Bernardi,
P. Zarka,
A. Ghosh,
A. Alexov,
J. Anderson,
A. Asgekar,
I. M. Avruch,
R. Beck,
M. E. Bell,
M. R. Bell,
M. J. Bentum,
P. Best,
L. Bîrzan,
F. Breitling
, et al. (53 additional authors not shown)
Abstract:
Faint undetected sources of radio-frequency interference (RFI) might become visible in long radio observations when they are consistently present over time. Thereby, they might obstruct the detection of the weak astronomical signals of interest. This issue is especially important for Epoch of Reionisation (EoR) projects that try to detect the faint redshifted HI signals from the time of the earlie…
▽ More
Faint undetected sources of radio-frequency interference (RFI) might become visible in long radio observations when they are consistently present over time. Thereby, they might obstruct the detection of the weak astronomical signals of interest. This issue is especially important for Epoch of Reionisation (EoR) projects that try to detect the faint redshifted HI signals from the time of the earliest structures in the Universe. We explore the RFI situation at 30-163 MHz by studying brightness histograms of visibility data observed with LOFAR, similar to radio-source-count analyses that are used in cosmology. An empirical RFI distribution model is derived that allows the simulation of RFI in radio observations. The brightness histograms show an RFI distribution that follows a power-law distribution with an estimated exponent around -1.5. With several assumptions, this can be explained with a uniform distribution of terrestrial radio sources whose radiation follows existing propagation models. Extrapolation of the power law implies that the current LOFAR EoR observations should be severely RFI limited if the strength of RFI sources remains strong after time integration. This is in contrast with actual observations, which almost reach the thermal noise and are thought not to be limited by RFI. Therefore, we conclude that it is unlikely that there are undetected RFI sources that will become visible in long observations. Consequently, there is no indication that RFI will prevent an EoR detection with LOFAR.
△ Less
Submitted 21 July, 2013;
originally announced July 2013.
-
Physics at the CLIC e+e- Linear Collider -- Input to the Snowmass process 2013
Authors:
Halina Abramowicz,
Angel Abusleme,
Konstatin Afanaciev,
Gideon Alexander,
Niloufar Alipour Tehrani,
Oscar Alonso,
Kristoffer K. Andersen,
Samir Arfaoui,
Csaba Balazs,
Tim Barklow,
Marco Battaglia,
Mathieu Benoit,
Burak Bilki,
Jean-Jacques Blaising,
Mark Boland,
Marça Boronat,
Ivanka Božović Jelisavčić,
Philip Burrows,
Maximilien Chefdeville,
Roberto Contino,
Dominik Dannheim,
Marcel Demarteau,
Marco Aurelio Diaz Gutierrez,
Angel Diéguez,
Jorge Duarte Campderros
, et al. (98 additional authors not shown)
Abstract:
This paper summarizes the physics potential of the CLIC high-energy e+e- linear collider. It provides input to the Snowmass 2013 process for the energy-frontier working groups on The Higgs Boson (HE1), Precision Study of Electroweak Interactions (HE2), Fully Understanding the Top Quark (HE3), as well as The Path Beyond the Standard Model -- New Particles, Forces, and Dimensions (HE4). It is accomp…
▽ More
This paper summarizes the physics potential of the CLIC high-energy e+e- linear collider. It provides input to the Snowmass 2013 process for the energy-frontier working groups on The Higgs Boson (HE1), Precision Study of Electroweak Interactions (HE2), Fully Understanding the Top Quark (HE3), as well as The Path Beyond the Standard Model -- New Particles, Forces, and Dimensions (HE4). It is accompanied by a paper describing the CLIC accelerator study, submitted to the Frontier Capabilities group of the Snowmass process.
△ Less
Submitted 30 September, 2013; v1 submitted 19 July, 2013;
originally announced July 2013.
-
Forward tracking at the next \boldmath{$e^+e^-$} collider Part II: experimental challenges and detector design
Authors:
Steve Aplin,
Marça Boronat,
Dominik Dannheim,
Jordi Duarte,
F. Gaede,
Alberto Ruiz-Jimeno,
Andre Sailer,
Manfred Valentan,
Ivan Vila,
Marcel Vos
Abstract:
We present the second in a series of studies into the forward tracking system for a future linear $ e^+ e^- $ collider with a center-of-mass energy in the range from 250 GeV to 3 TeV. In this note a number of specific challenges are investigated, that have caused a degradation of the tracking and vertexing performance in the forward region in previous experiments. We perform a quantitative analysi…
▽ More
We present the second in a series of studies into the forward tracking system for a future linear $ e^+ e^- $ collider with a center-of-mass energy in the range from 250 GeV to 3 TeV. In this note a number of specific challenges are investigated, that have caused a degradation of the tracking and vertexing performance in the forward region in previous experiments. We perform a quantitative analysis of the dependence of the tracking performance on detector design parameters and identify several ways to mitigate the performance loss for charged particles emitted at shallow angle.
△ Less
Submitted 26 March, 2013; v1 submitted 13 March, 2013;
originally announced March 2013.
-
DEPFET active pixel detectors for a future linear $e^+e^-$ collider
Authors:
O. Alonso,
R. Casanova,
A. Dieguez,
J. Dingfelder,
T. Hemperek,
T. Kishishita amd T. Kleinohl,
M. Koch,
H. Krueger,
M. Lemarenko,
F. Luetticke,
C. Marinas,
M. Schnell,
N. Wermes,
A. Campbell,
T. Ferber,
C. Kleinwort,
C. Niebuhr,
Y. Soloviev,
M. Steder,
R. Volkenborn,
S. Yaschenko,
P. Fischer,
C. Kreidl,
I. Peric,
J. Knopf
, et al. (62 additional authors not shown)
Abstract:
The DEPFET collaboration develops highly granular, ultra-transparent active pixel detectors for high-performance vertex reconstruction at future collider experiments. The characterization of detector prototypes has proven that the key principle, the integration of a first amplification stage in a detector-grade sensor material, can provide a comfortable signal to noise ratio of over 40 for a senso…
▽ More
The DEPFET collaboration develops highly granular, ultra-transparent active pixel detectors for high-performance vertex reconstruction at future collider experiments. The characterization of detector prototypes has proven that the key principle, the integration of a first amplification stage in a detector-grade sensor material, can provide a comfortable signal to noise ratio of over 40 for a sensor thickness of 50-75 $\mathrm{\mathbf{μm}}$. ASICs have been designed and produced to operate a DEPFET pixel detector with the required read-out speed. A complete detector concept is being developed, including solutions for mechanical support, cooling and services. In this paper the status of DEPFET R & D project is reviewed in the light of the requirements of the vertex detector at a future linear $\mathbf{e^+ e^-}$ collider.
△ Less
Submitted 10 December, 2012;
originally announced December 2012.
-
CLIC Background Studies and optimization of the innermost tracker elements
Authors:
D. Dannheim,
A. Sailer,
J. Trenado,
M. Vos
Abstract:
The harsh machine background at the Compact Linear Collider (CLIC) forms a strong constraint on the design of the innermost part of the tracker. For the CLIC Conceptual Design Report, the detector concepts developed for the International Linear Collider (ILC) were adapted to the CLIC environment. We present the new layout for the Vertex Detector and the Forward Tracking Disks of the CLIC detector…
▽ More
The harsh machine background at the Compact Linear Collider (CLIC) forms a strong constraint on the design of the innermost part of the tracker. For the CLIC Conceptual Design Report, the detector concepts developed for the International Linear Collider (ILC) were adapted to the CLIC environment. We present the new layout for the Vertex Detector and the Forward Tracking Disks of the CLIC detector concepts, as well as the background levels in these detectors. We also study the dependence of the background rates on technology parameters like thickness of the active layer and detection threshold.
△ Less
Submitted 5 March, 2012;
originally announced March 2012.
-
Geiger-Mode Avalanche Photodiodes in Particle Detection
Authors:
E. Vilella,
O. Alonso,
J. Trenado,
A. Vilà,
M. Vos,
L. Garrido,
A. Diéguez
Abstract:
It is well known that avalanche photodiodes operated in the Geiger mode above the breakdown voltage offer a virtually infinite sensitivity and time accuracy in the picosecond range that can be used for single photon detection. However, their performance in particle detection remains still unexplored. In this contribution, we are going to expose the different steps that we have taken in order to pr…
▽ More
It is well known that avalanche photodiodes operated in the Geiger mode above the breakdown voltage offer a virtually infinite sensitivity and time accuracy in the picosecond range that can be used for single photon detection. However, their performance in particle detection remains still unexplored. In this contribution, we are going to expose the different steps that we have taken in order to prove the efficiency of Geiger mode avalanche photodiodes in the aforementioned field. In particular, we will present an array of pixels of 1mmx1mm fabricated with a standard CMOS technology for characterization in a test beam.
△ Less
Submitted 27 January, 2012;
originally announced January 2012.
-
Belle II Technical Design Report
Authors:
T. Abe,
I. Adachi,
K. Adamczyk,
S. Ahn,
H. Aihara,
K. Akai,
M. Aloi,
L. Andricek,
K. Aoki,
Y. Arai,
A. Arefiev,
K. Arinstein,
Y. Arita,
D. M. Asner,
V. Aulchenko,
T. Aushev,
T. Aziz,
A. M. Bakich,
V. Balagura,
Y. Ban,
E. Barberio,
T. Barvich,
K. Belous,
T. Bergauer,
V. Bhardwaj
, et al. (387 additional authors not shown)
Abstract:
The Belle detector at the KEKB electron-positron collider has collected almost 1 billion Y(4S) events in its decade of operation. Super-KEKB, an upgrade of KEKB is under construction, to increase the luminosity by two orders of magnitude during a three-year shutdown, with an ultimate goal of 8E35 /cm^2 /s luminosity. To exploit the increased luminosity, an upgrade of the Belle detector has been pr…
▽ More
The Belle detector at the KEKB electron-positron collider has collected almost 1 billion Y(4S) events in its decade of operation. Super-KEKB, an upgrade of KEKB is under construction, to increase the luminosity by two orders of magnitude during a three-year shutdown, with an ultimate goal of 8E35 /cm^2 /s luminosity. To exploit the increased luminosity, an upgrade of the Belle detector has been proposed. A new international collaboration Belle-II, is being formed. The Technical Design Report presents physics motivation, basic methods of the accelerator upgrade, as well as key improvements of the detector.
△ Less
Submitted 1 November, 2010;
originally announced November 2010.
-
Summary of the Linear Collider Testbeam Workshop 2009 - LCTW09
Authors:
V. Boudry,
G. Fisk,
R. E. Frey,
F. Gaede,
C. Hast,
J. Hauptman,
K. Kawagoe,
L. Linssen,
R. Lipton,
W. Lohmann,
T. Matsuda,
T. Nelson,
R. Poeschl,
E. Ramberg,
F. Sefkow,
M. Vos,
M. Wing,
J. Yu
Abstract:
This note summarises the workshop LCTW09 held between the 3.11.2009 and 5.11.2009 at LAL Orsay. The workshop was dedicated to discuss the beam tests in the years 2010 up to 2013 for detectors to be operated at a future linear electron positron collider. The document underlines the rich R&D program on these detectors in the coming years. Large synergies were identified in the DAQ and software syste…
▽ More
This note summarises the workshop LCTW09 held between the 3.11.2009 and 5.11.2009 at LAL Orsay. The workshop was dedicated to discuss the beam tests in the years 2010 up to 2013 for detectors to be operated at a future linear electron positron collider. The document underlines the rich R&D program on these detectors in the coming years. Large synergies were identified in the DAQ and software systems. Considerable consolidation of resources are expected from the establishment of semi-permanent beam lines for linear collider detector R&D at major centres like CERN and FNAL. Reproducing a beam structure as foreseen for the International Linear Collider (ILC) would clearly enhance the value of the obtained beam test results. Although not ultimately needed for every research program, all groups would exploit such a feature if it is available.
△ Less
Submitted 7 October, 2010;
originally announced October 2010.
-
A Comparative Study of the Valence Electronic Excitations of N_2 by Inelastic X-ray and Electron Scattering
Authors:
J. A. Bradley,
G. T. Seidler,
G. Cooper,
M. Vos,
A. P. Hitchcock,
A. P. Sorini,
C. Schlimmer,
K. P. Nagle
Abstract:
Bound state, valence electronic excitation spectra of N_2 are probed by nonresonant inelastic x-ray and electron scattering. Within the usual theoretical treatments, dynamical structure factors derived from the two probes should be identical. However, we find strong disagreements outside the dipole scattering limit, even at high probe energies. This suggests an unexpectedly important contributi…
▽ More
Bound state, valence electronic excitation spectra of N_2 are probed by nonresonant inelastic x-ray and electron scattering. Within the usual theoretical treatments, dynamical structure factors derived from the two probes should be identical. However, we find strong disagreements outside the dipole scattering limit, even at high probe energies. This suggests an unexpectedly important contribution from intra-molecular multiple scattering of the probe electron from core electrons or the nucleus. These effects should grow progressively stronger as the atomic number of the target species increases.
△ Less
Submitted 12 May, 2010;
originally announced May 2010.
-
SiLC simulation status report
Authors:
Marcel Vos
Abstract:
The SiLC - Silicon for the Linear Collider - collaboration aims to develop silicon detector technology for tracking in the international linear collider experiments. The R & D programme involves a substantial effort in simulation of the response of detector designs. In this contribution, an overview of ongoing efforts in this area is given.
The SiLC - Silicon for the Linear Collider - collaboration aims to develop silicon detector technology for tracking in the international linear collider experiments. The R & D programme involves a substantial effort in simulation of the response of detector designs. In this contribution, an overview of ongoing efforts in this area is given.
△ Less
Submitted 29 January, 2008;
originally announced January 2008.