Skip to main content

Showing 1–21 of 21 results for author: Voïgt, J

Searching in archive physics. Search in all archives.
.
  1. arXiv:2405.09159  [pdf, other

    physics.ins-det

    An indirect geometry crystal time-of-flight spectrometer for FRM II

    Authors: Ran Tang, Christoph Herb, Jörg Voigt, Robert Georgii

    Abstract: We present a concept for an indirect geometry crystal time-of-flight spectrometer, which we propose for the FRM-II reactor in Garching. Recently, crystal analyzer spectrometers at modern spallation sources have been proposed and are under construction. The secondary spectrometers of these instruments are evolutions of the flat cone multi-analyzer for three-axis spectrometers (TAS). The instruments… ▽ More

    Submitted 15 May, 2024; originally announced May 2024.

  2. arXiv:2309.16877  [pdf, other

    physics.ins-det hep-ex nucl-ex

    Achieving ultra-low and -uniform residual magnetic fields in a very large magnetically shielded room for fundamental physics experiments

    Authors: N. J. Ayres, G. Ban, G. Bison, K. Bodek, V. Bondar, T. Bouillaud, D. Bowles, E. Chanel, W. Chen, P. -J. Chiu, C. B. Crawford, O. Naviliat-Cuncic, C. B. Doorenbos, S. Emmenegger, M. Fertl, A. Fratangelo, W. C. Griffith, Z. D. Grujic, P. G. Harris, K. Kirch, V. Kletzl, J. Krempel, B. Lauss, T. Lefort, A. Lejuez , et al. (25 additional authors not shown)

    Abstract: High-precision searches for an electric dipole moment of the neutron (nEDM) require stable and uniform magnetic field environments. We present the recent achievements of degaussing and equilibrating the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute. We present the final degaussing configuration that will be used for n2EDM after numerous studies. The optim… ▽ More

    Submitted 28 September, 2023; originally announced September 2023.

  3. arXiv:2101.08730  [pdf, other

    physics.ins-det nucl-ex

    The design of the n2EDM experiment

    Authors: N. J. Ayres, G. Ban, L. Bienstman, G. Bison, K. Bodek, V. Bondar, T. Bouillaud, E. Chanel, J. Chen, P. -J. Chiu, B. Clément, C. Crawford, M. Daum, B. Dechenaux, C. B. Doorenbos, S. Emmenegger, L. Ferraris-Bouchez, M. Fertl, A. Fratangelo, P. Flaux, D. Goupillière, W. C. Griffith, Z. D. Grujic, P. G. Harris, K. Kirch , et al. (36 additional authors not shown)

    Abstract: We present the design of a next-generation experiment, n2EDM, currently under construction at the ultracold neutron source at the Paul Scherrer Institute (PSI) with the aim of carrying out a high-precision search for an electric dipole moment of the neutron. The project builds on experience gained with the previous apparatus operated at PSI until 2017, and is expected to deliver an order of magnit… ▽ More

    Submitted 22 January, 2021; v1 submitted 21 January, 2021; originally announced January 2021.

    Journal ref: Eur. Phys. J. C 81, 512 (2021)

  4. arXiv:2011.12617  [pdf, other

    physics.ins-det hep-ex

    Characterization of magnetic field noise in the ARIADNE source mass rotor

    Authors: Nancy Aggarwal, Allard Schnabel, Jens Voigt, Alex Brown, Josh C Long, L. Trahms, A. Fang, Andrew Geraci, A. Kapitulnik, D. Kim, Y. Kim, I. Lee, Y. H. Lee, C. Y. Liu, C. Lohmeyer, A. Reid, Y. Semertzidis, Y. Shin, J. Shortino, E. Smith, W. M. Snow, E. Weisman

    Abstract: ARIADNE is a nuclear-magnetic-resonance-based experiment that will search for novel axion-induced spin-dependent interactions between an unpolarized source mass rotor and a nearby sample of spin-polarized $^3$He gas. To detect feeble axion signals at the sub-atto-Tesla level, the experiment relies on low magnetic background and noise. We measure and characterize the magnetic field background from… ▽ More

    Submitted 25 November, 2020; originally announced November 2020.

    Comments: 6 pages, 5 figures

  5. arXiv:2011.10141  [pdf, other

    physics.ins-det hep-ex

    Source mass characterization in the ARIADNE axion experiment

    Authors: Chloe Lohmeyer, Nancy Aggarwal, Asimina Arvanitaki, Alex Brown, Alan Fang, Andrew A Geraci, Aharon Kapitulnik, Dongok Kim, Younggeun Kim, Inbum Lee, Yong Ho Lee, Eli Levenson-Falk, Chen Yu Liu, Josh C Long, Sam Mumford, Austin Reid, Allard Schnabel, Yannis Semertzidis, Yun Shin, Justin Shortino, Eric Smith, William M Snow, Lutz Trahms, Jens Voigt, Evan Weisman

    Abstract: The Axion Resonant InterAction Detection Experiment (ARIADNE) is a collaborative effort to search for the QCD axion using nuclear magnetic resonance (NMR), where the axion acts as a mediator of spin-dependent forces between an unpolarized tungsten source mass and a sample of polarized helium-3 gas. Since the experiment involves precision measurement of a small magnetization, it relies on limiting… ▽ More

    Submitted 19 November, 2020; originally announced November 2020.

    Comments: ARIADNE Collaboration

    Journal ref: Proceedings of the 3rd International Workshop on Microwave Cavities and Detectors for Axion Research 2020

  6. arXiv:2008.10886  [pdf, other

    physics.app-ph

    A Three-step Model for Optimizing Coil Spacings Inside Cuboid-shaped Magnetic Shields

    Authors: Tianhao Liu, Allard Schnabel, Jens Voigt, Zhiyin Sun, Liyi Li

    Abstract: A three-step model for calculating the magnetic field generated by coils inside cuboid-shaped shields like magnetically shielded rooms (MSRs) is presented. The shield is modelled as two parallel plates of infinite width and one tube of infinite height. We propose an improved mirror method which considers the effect of the parallel plates of finite thickness. A reaction factor is introduced to desc… ▽ More

    Submitted 25 August, 2020; originally announced August 2020.

    Journal ref: AIP Advances,2020

  7. arXiv:2008.07975  [pdf, other

    physics.atom-ph nucl-ex

    Revisiting $^{129}$Xe electric dipole moment measurements applying a new global phase fitting approach

    Authors: T. Liu, K. Rolfs, I. Fan, S. Haude, W. Kilian, L. Li, A. Schnabel, J. Voigt, L. Trahms

    Abstract: By measuring the nuclear magnetic spin precession frequencies of polarized $^{129}$Xe and $^{3}$He, a new upper limit on the $^{129}$Xe atomic electric dipole moment (EDM) $ d_\mathrm{A} (^{129}\mathrm{Xe})$ was reported in Phys. Rev. Lett. 123, 143003 (2019). Here, we propose a new evaluation method based on global phase fitting (GPF) for analyzing the continuous phase development of the $^{3}$He… ▽ More

    Submitted 15 November, 2020; v1 submitted 18 August, 2020; originally announced August 2020.

    Comments: Acknowledgement changed; Format changed and several wordings are modified to avoid potential confusions

  8. arXiv:2008.05279  [pdf

    physics.bio-ph physics.app-ph physics.atom-ph

    Action potentials induce biomagnetic fields in Venus flytrap plants

    Authors: Anne Fabricant, Geoffrey Z. Iwata, Sönke Scherzer, Lykourgos Bougas, Katharina Rolfs, Anna Jodko-Władzińska, Jens Voigt, Rainer Hedrich, Dmitry Budker

    Abstract: Upon stimulation, plants elicit electrical signals that can travel within a cellular network analogous to the animal nervous system. It is well-known that in the human brain, voltage changes in certain regions result from concerted electrical activity which, in the form of action potentials (APs), travels within nerve-cell arrays. Electrophysiological techniques like electroencephalography, magnet… ▽ More

    Submitted 18 August, 2020; v1 submitted 12 August, 2020; originally announced August 2020.

    Comments: 22 pages, 11 figures; updated figures and references, corrected typos and minor omissions, improved formatting

  9. arXiv:2001.11966  [pdf, other

    hep-ex nucl-ex physics.ins-det

    Measurement of the permanent electric dipole moment of the neutron

    Authors: C. Abel, S. Afach, N. J. Ayres, C. A. Baker, G. Ban, G. Bison, K. Bodek, V. Bondar, M. Burghoff, E. Chanel, Z. Chowdhuri, P. -J. Chiu, B. Clement, C. B. Crawford, M. Daum, S. Emmenegger, L. Ferraris-Bouchez, M. Fertl, P. Flaux, B. Franke, A. Fratangelo, P. Geltenbort, K. Green, W. C. Griffith, M. van der Grinten , et al. (59 additional authors not shown)

    Abstract: We present the result of an experiment to measure the electric dipole moment (EDM) of the neutron at the Paul Scherrer Institute using Ramsey's method of separated oscillating magnetic fields with ultracold neutrons (UCN). Our measurement stands in the long history of EDM experiments probing physics violating time reversal invariance. The salient features of this experiment were the use of a Hg-19… ▽ More

    Submitted 31 January, 2020; originally announced January 2020.

    Comments: 5 pages, 4 figures, submitted to PRL on 18.12.2019

    Journal ref: Phys. Rev. Lett. 124, 081803 (2020)

  10. New Limit on the Permanent Electric Dipole Moment of $^{129}$Xe using $^{3}$He Comagnetometry and SQUID Detection

    Authors: N. Sachdeva, I. Fan, E. Babcock, M. Burghoff, T. E. Chupp, S. Degenkolb, P. Fierlinger, S. Haude, E. Kraegeloh, W. Kilian, S. Knappe-Grüneberg, F. Kuchler, T. Liu, M. Marino, J. Meinel, K. Rolfs, Z. Salhi, A. Schnabel, J. T. Singh, S. Stuiber, W. A. Terrano, L. Trahms, J. Voigt

    Abstract: We report results of a new technique to measure the electric dipole moment of $^{129}$Xe with $^3$He comagnetometry. Both species are polarized using spin-exchange optical pum**, transferred to a measurement cell, and transported into a magnetically shielded room, where SQUID magnetometers detect free precession in applied electric and magnetic fields. The result from a one week measurement camp… ▽ More

    Submitted 26 September, 2019; originally announced September 2019.

    Comments: To be published in Physical Review Letters. arXiv admin note: substantial text overlap with arXiv:1902.02864

  11. arXiv:1903.01492  [pdf, other

    physics.ins-det physics.atom-ph

    PicoTesla absolute field readings with a hybrid 3He/87Rb magnetometer

    Authors: Christopher Abel, Georg Bison, W. Clark Griffith, Werner Heil, Klaus Kirch, Hans-Christian Koch, Bernhard Lauss, Alexander Mtchedlishvili, Martin Pototschnig, Philipp Schmidt-Wellenburg, Allard Schnabel, Duarte Vicente Pais, Jens Voigt

    Abstract: We demonstrate the use of a hybrid $^{3}$He / $^{87}$Rb magnetometer to measure absolute magnetic fields in the pT range. The measurements were undertaken by probing time-dependent $^3$He magnetisation using $^{87}$Rb zero-field magnetometers. Measurements were taken to demonstrate the use of the magnetometer in cancelling residual fields within a magnetic shield. It was shown that the absolute fi… ▽ More

    Submitted 4 March, 2019; originally announced March 2019.

  12. arXiv:1902.02864  [pdf, other

    physics.atom-ph physics.ins-det

    A new measurement of the permanent electric dipole moment of $^{129}$Xe using $^{3}$He comagnetometry and SQUID detection

    Authors: N. Sachdeva, I. Fan, E. Babcock, M. Burghoff, T. E. Chupp, S. Degenkolb, P. Fierlinger, E. Kraegeloh, W. Kilian, S. Knappe-Grüneberg, F. Kuchler, T. Liu, M. Marino, J. Meinel, Z. Salhi, A. Schnabel, J. T. Singh, S. Stuiber, W. A. Terrano, L. Trahms, J. Voigt

    Abstract: We describe a new technique to measure the EDM of $^{129}$Xe with $^3$He comagnetometry. Both species are polarized using spin-exchange optical pum**, transferred to a measurement cell, and transported into a magnetically shielded room, where SQUID magnetometers detect free precession in applied electric and magnetic fields. The result of a one week run combined with a detailed study of systemat… ▽ More

    Submitted 7 February, 2019; originally announced February 2019.

  13. arXiv:1811.04012  [pdf, other

    physics.ins-det nucl-ex

    nEDM experiment at PSI: data-taking strategy and sensitivity of the dataset

    Authors: C. Abel, N. J. Ayres, G. Ban, G. Bison, K. Bodek, V. Bondar, E. Chanel, P. -J. Chiu, M. Daum, S. Emmenegger, L. Ferraris-Bouchez, P. Flaux, W. C. Griffith P. G. Harris, N. Hild, Y. Kermaidic, K. Kirch, P. A. Koss, J. Krempel, B. Lauss, T. Lefort, Y. Lemiere, A. Leredde, P. Mohanmurthy, M. Musgrave, O. Naviliat-Cuncic , et al. (18 additional authors not shown)

    Abstract: We report on the strategy used to optimize the sensitivity of our search for a neutron electric dipole moment at the Paul Scherrer Institute. Measurements were made upon ultracold neutrons stored within a single chamber at the heart of our apparatus. A mercury cohabiting magnetometer together with an array of cesium magnetometers were used to monitor the magnetic field, which was controlled and sh… ▽ More

    Submitted 9 November, 2018; originally announced November 2018.

    Comments: Submitted as a web of conference proceedings paper for PPNS2018

  14. arXiv:1811.02340  [pdf, other

    physics.ins-det hep-ex nucl-ex

    The n2EDM experiment at the Paul Scherrer Institute

    Authors: C. Abel, N. J. Ayres, G. Ban, G. Bison, K. Bodek, V. Bondar, E. Chanel, P. -J. Chiu, B. Clement, C. Crawford, M. Daum, S. Emmenegger, P. Flaux, L. Ferraris-Bouchez, W. C. Griffith, Z. D. Grujić, P. G. Harris, W. Heil, N. Hild, K. Kirch, P. A. Koss, A. Kozela, J. Krempel, B. Lauss, T. Lefort , et al. (23 additional authors not shown)

    Abstract: We present the new spectrometer for the neutron electric dipole moment (nEDM) search at the Paul Scherrer Institute (PSI), called n2EDM. The setup is at room temperature in vacuum using ultracold neutrons. n2EDM features a large UCN double storage chamber design with neutron transport adapted to the PSI UCN source. The design builds on experience gained from the previous apparatus operated at PSI… ▽ More

    Submitted 27 February, 2019; v1 submitted 6 November, 2018; originally announced November 2018.

    Comments: Submitted as a web of conference proceedings paper

  15. arXiv:1809.02370  [pdf

    physics.ins-det cond-mat.mtrl-sci

    Neutron Scattering Instrumentation at Compact Neutron Sources

    Authors: Sarah Böhm, Tobias Cronert, Jan-Philipp Dabrück, Xavier Fabrèges, Thomas Gutberlet, Ferenc Mezei, Alain Letourneau, Alain Menelle, Frédéric Ott, Ulrich Rücker, Hoang Tran, Jorg Voïgt, Paul Zakalek

    Abstract: There is currently a strong interest in Compact Accelerator-based Neutron Source (CANS) as a possible new type of source for neutron scattering experiments. A workshop around the "Neutron scattering instrumentation around CANS" was organized in July 2017 between several European institutes. This report summarizes the main outcome of the discussions. The document is aiming at providing general guid… ▽ More

    Submitted 7 September, 2018; originally announced September 2018.

    Comments: Minutes of the "Neutron Scattering Instrumentation at CANS" workshop, Gif-sur-Yvette, France, Juillet 2018

  16. Design and performance of an absolute $^3$He/Cs magnetometer

    Authors: H. -C. Koch, G. Bison, Z. D. Grujić, W. Heil, M. Kasprzak, P. Knowles, A. Kraft, A. Pazgalev, A. Schnabel, J. Voigt, A. Weis

    Abstract: We report on the design and performance of a highly sensitive combined $^3$He/Cs magnetometer for the absolute measurement of magnetic fields. The magnetometer relies on the magnetometric detection of the free spin precession of nuclear spin polarized $^3$He gas by optically pumped cesium magnetometers. We plan to deploy this type of combined magnetometer in an experiment searching for a permanent… ▽ More

    Submitted 24 August, 2015; v1 submitted 23 February, 2015; originally announced February 2015.

    Comments: The final publication is available at Springer via http://dx.doi.org/10.1140/epjd/e2015-60018-7

    Journal ref: Eur. Phys. J. D (2015) 69: 202

  17. arXiv:1501.07861  [pdf, other

    physics.ins-det

    A large-scale magnetic shield with 10^6 dam** at mHz frequencies

    Authors: I. Altarev, M. Bales, D. H. Beck, T. Chupp, K. Fierlinger, P. Fierlinger, F. Kuchler, T. Lins, M. G. Marino, B. Niessen, G. Petzoldt, J. T. Singh, U. Schläpfer, A. Schnabel, R. Stoepler, S. Stuiber, M. Strum, B. Taubenheim, J. Voigt

    Abstract: We present a magnetically shielded environment with a dam** factor larger than one million at the mHz frequency regime and an extremely low field and gradient over an extended volume. This extraordinary shielding performance represents an improvement of the state of the art in dam** the difficult regime of very low-frequency distortions by more than an order of magnitude. This technology enabl… ▽ More

    Submitted 23 May, 2015; v1 submitted 30 January, 2015; originally announced January 2015.

    Comments: 7 pages, 5 figures, 1 table

    Journal ref: J. Appl. Phys. 117, 183903 (2015)

  18. arXiv:1410.8259  [pdf, other

    nucl-ex physics.atom-ph physics.ins-det

    A measurement of the neutron to 199Hg magnetic moment ratio

    Authors: S. Afach, C. A. Baker, G. Ban, G. Bison, K. Bodek, M. Burghoff, Z. Chowdhuri, M. Daum, M. Fertl, B. Franke, P. Geltenbort, K. Green, M. G. D. van der Grinten, Z. Grujic, P. G. Harris, W. Heil, V. Hélaine, R. Henneck, M. Horras, P. Iaydjiev, S. N. Ivanov, M. Kasprzak, Y. Kermaïdic, K. Kirch, A. Knecht , et al. (29 additional authors not shown)

    Abstract: The neutron gyromagnetic ratio has been measured relative to that of the 199Hg atom with an uncertainty of 0.8 ppm. We employed an apparatus where ultracold neutrons and mercury atoms are stored in the same volume and report the result $γ_{\rm n}/γ_{\rm Hg} = 3.8424574(30)$.

    Submitted 31 October, 2014; v1 submitted 30 October, 2014; originally announced October 2014.

    Journal ref: Physics Letters B 739, 128-132 (2014)

  19. arXiv:1408.6752  [pdf, other

    physics.ins-det nucl-ex physics.atom-ph

    Dynamic stabilization of the magnetic field surrounding the neutron electric dipole moment spectrometer at the Paul Scherrer Institute

    Authors: S. Afach, G. Bison, K. Bodek, F. Burri, Z. Chowdhuri, M. Daum, M. Fertl, B. Franke, Z. Grujic, V. Helaine, R. Henneck, M. Kasprzak, K. Kirch, H. -C. Koch, A. Kozela, J. Krempel, B. Lauss, T. Lefort, Y. Lemiere, M. Meier, O. Naviliat-Cuncic, F. M. Piegsa, G. Pignol, C. Plonka-Spehr, P. N. Prashanth , et al. (12 additional authors not shown)

    Abstract: The Surrounding Field Compensation (SFC) system described in this work is installed around the four-layer Mu-metal magnetic shield of the neutron electric dipole moment spectrometer located at the Paul Scherrer Institute. The SFC system reduces the DC component of the external magnetic field by a factor of about 20. Within a control volume of approximately 2.5m x 2.5m x 3m disturbances of the magn… ▽ More

    Submitted 28 August, 2014; originally announced August 2014.

    Comments: 33 pages, 18 figures

    Journal ref: J. Appl. Phys. 116, 084510 (2014)

  20. arXiv:1403.6467  [pdf, other

    physics.ins-det

    A magnetically shielded room with ultra low residual field and gradient

    Authors: I. Altarev, E. Babcock, D. Beck, M. Burghoff, S. Chesnevskaya, T. Chupp, S. Degenkolb, I. Fan, P. Fierlinger, A. Frei, E. Gutsmiedl, S. Knappe-Grüneberg, F. Kuchler, T. Lauer, P. Link, T. Lins, M. Marino, J. McAndrew, B. Niessen, S. Paul, G. Petzoldt, U. Schläpfer, A. Schnabel, S. Sharma, J. Singh , et al. (7 additional authors not shown)

    Abstract: A versatile and portable magnetically shielded room with a field of (700 \pm 200) pT within a central volume of 1m x 1m x 1m and a field gradient less than 300 pT/m is described. This performance represents more than a hundred-fold improvement of the state of the art for a two-layer magnetic shield and provides an environment suitable for a next generation of precision experiments in fundamental p… ▽ More

    Submitted 24 March, 2014; originally announced March 2014.

    Journal ref: Rev. Sci. Instrum. 85, 075106 (2014)

  21. arXiv:1308.2563  [pdf, other

    physics.ins-det

    Copper coated carbon fiber reinforced plastics for high and ultra high vacuum applications

    Authors: F. Burri, M. Fertl, P. Feusi, R. Henneck, K. Kirch, B. Lauss, P. Ruettimann, P. Schmidt-Wellenburg, A. Schnabel, J. Voigt, J. Zenner, G. Zsigmond

    Abstract: We have used copper-coated carbon fiber reinforced plastic (CuCFRP) for the construction of high and ultra-high vacuum recipients. The vacuum performance is found to be comparable to typical stainless steel used for this purpose. In test recipients we have reached pressures of 2E-8 mbar and measured a desorption rate of 1E-11 mbar*liter/s/cm^2; no degradation over time (2 years) has been found. Su… ▽ More

    Submitted 12 August, 2013; originally announced August 2013.

    Comments: 17 pages, 10 figures, to be published in NIMA