-
Technical Design Report of the Spin Physics Detector at NICA
Authors:
The SPD Collaboration,
V. Abazov,
V. Abramov,
L. Afanasyev,
R. Akhunzyanov,
A. Akindinov,
I. Alekseev,
A. Aleshko,
V. Alexakhin,
G. Alexeev,
L. Alimov,
A. Allakhverdieva,
A. Amoroso,
V. Andreev,
V. Andreev,
E. Andronov,
Yu. Anikin,
S. Anischenko,
A. Anisenkov,
V. Anosov,
E. Antokhin,
A. Antonov,
S. Antsupov,
A. Anufriev,
K. Asadova
, et al. (392 additional authors not shown)
Abstract:
The Spin Physics Detector collaboration proposes to install a universal detector in the second interaction point of the NICA collider under construction (JINR, Dubna) to study the spin structure of the proton and deuteron and other spin-related phenomena using a unique possibility to operate with polarized proton and deuteron beams at a collision energy up to 27 GeV and a luminosity up to…
▽ More
The Spin Physics Detector collaboration proposes to install a universal detector in the second interaction point of the NICA collider under construction (JINR, Dubna) to study the spin structure of the proton and deuteron and other spin-related phenomena using a unique possibility to operate with polarized proton and deuteron beams at a collision energy up to 27 GeV and a luminosity up to $10^{32}$ cm$^{-2}$ s$^{-1}$. As the main goal, the experiment aims to provide access to the gluon TMD PDFs in the proton and deuteron, as well as the gluon transversity distribution and tensor PDFs in the deuteron, via the measurement of specific single and double spin asymmetries using different complementary probes such as charmonia, open charm, and prompt photon production processes. Other polarized and unpolarized physics is possible, especially at the first stage of NICA operation with reduced luminosity and collision energy of the proton and ion beams. This document is dedicated exclusively to technical issues of the SPD setup construction.
△ Less
Submitted 28 May, 2024; v1 submitted 12 April, 2024;
originally announced April 2024.
-
Particle Identification at VAMOS++ with Machine Learning Techniques
Authors:
Y. Cho,
Y. H. Kim,
S. Choi,
J. Park,
S. Bae,
K. I. Hahn,
Y. Son,
A. Navin,
A. Lemasson,
M. Rejmund,
D. Ramos,
D. Ackermann,
A. Utepov,
C. Fourgeres,
J. C. Thomas,
J. Goupil,
G. Fremont,
G. de France,
Y. X. Watanabe,
Y. Hirayama,
S. Jeong,
T. Niwase,
H. Miyatake,
P. Schury,
M. Rosenbusch
, et al. (23 additional authors not shown)
Abstract:
Multi-nucleon transfer reaction between 136Xe beam and 198Pt target was performed using the VAMOS++ spectrometer at GANIL to study the structure of n-rich nuclei around N=126. Unambiguous charge state identification was obtained by combining two supervised machine learning methods, deep neural network (DNN) and positional correction using a gradient-boosting decision tree (GBDT). The new method re…
▽ More
Multi-nucleon transfer reaction between 136Xe beam and 198Pt target was performed using the VAMOS++ spectrometer at GANIL to study the structure of n-rich nuclei around N=126. Unambiguous charge state identification was obtained by combining two supervised machine learning methods, deep neural network (DNN) and positional correction using a gradient-boosting decision tree (GBDT). The new method reduced the complexity of the kinetic energy calibration and outperformed the conventional method, improving the charge state resolution by 8%
△ Less
Submitted 14 November, 2023; v1 submitted 13 November, 2023;
originally announced November 2023.
-
The LHCb upgrade I
Authors:
LHCb collaboration,
R. Aaij,
A. S. W. Abdelmotteleb,
C. Abellan Beteta,
F. Abudinén,
C. Achard,
T. Ackernley,
B. Adeva,
M. Adinolfi,
P. Adlarson,
H. Afsharnia,
C. Agapopoulou,
C. A. Aidala,
Z. Ajaltouni,
S. Akar,
K. Akiba,
P. Albicocco,
J. Albrecht,
F. Alessio,
M. Alexander,
A. Alfonso Albero,
Z. Aliouche,
P. Alvarez Cartelle,
R. Amalric,
S. Amato
, et al. (1298 additional authors not shown)
Abstract:
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their select…
▽ More
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their selection in real time. The experiment's tracking system has been completely upgraded with a new pixel vertex detector, a silicon tracker upstream of the dipole magnet and three scintillating fibre tracking stations downstream of the magnet. The whole photon detection system of the RICH detectors has been renewed and the readout electronics of the calorimeter and muon systems have been fully overhauled. The first stage of the all-software trigger is implemented on a GPU farm. The output of the trigger provides a combination of totally reconstructed physics objects, such as tracks and vertices, ready for final analysis, and of entire events which need further offline reprocessing. This scheme required a complete revision of the computing model and rewriting of the experiment's software.
△ Less
Submitted 17 May, 2023;
originally announced May 2023.
-
Lens free holographic imaging for urinary tract infection screening
Authors:
Gregory N. McKay,
Anisha Oommen,
Carolina Pacheco,
Mason T. Chen,
Stuart C. Ray,
René Vidal,
Benjamin D. Haeffele,
Nicholas J. Durr
Abstract:
Urinary tract infections (UTIs) are a common condition that can lead to serious complications including kidney injury, altered mental status, sepsis, and death. Laboratory tests such as urinalysis and urine culture are the mainstays of UTI diagnosis, whereby a urine specimen is collected and processed to reveal its cellular and chemical composition. This process requires precise specimen collectio…
▽ More
Urinary tract infections (UTIs) are a common condition that can lead to serious complications including kidney injury, altered mental status, sepsis, and death. Laboratory tests such as urinalysis and urine culture are the mainstays of UTI diagnosis, whereby a urine specimen is collected and processed to reveal its cellular and chemical composition. This process requires precise specimen collection, handling infectious human waste, controlled urine storage, and timely transportation to modern laboratory equipment for analysis. Holographic lens free imaging (LFI) can measure large volumes of urine via a simple and compact optical setup, potentially enabling automatic urine analysis at the patient bedside. We introduce an LFI system capable of resolving important urine clinical biomarkers such as red blood cells, white blood cells, crystals, casts, and E. Coli in urine phantoms. This approach is sensitive to the particulate concentrations relevant for detecting several clinical urine abnormalities such as hematuria, pyuria, and bacteriuria. We show bacteria concentrations across eight orders of magnitude can be estimated by analyzing LFI measurements. LFI measurements of blood cell concentrations are relatively insensitive to changes in bacteria concentrations of over seven orders of magnitude. Lastly, LFI reveals clear differences between UTI-positive and UTI-negative urine from human patients. Together, these results show promise for LFI as a tool for urine screening, potentially offering early, point-of-care detection of UTI and other pathological processes.
△ Less
Submitted 14 March, 2022;
originally announced March 2022.
-
The ferroelectric nematic phase: An optimum liquid crystal candidate for nonlinear optics
Authors:
C. L. Folcia,
J. Ortega,
R. Vidal,
T. Sierra,
J. Etxebarria
Abstract:
Materials that exhibit high nonlinear optical (NLO) susceptibilities are considered as promising candidates for a wide range of photonic and electronic applications. Here we argue that the ferroelectric nematic (NF) materials have sufficient potentialities to become materials for the next-generation of NLO devices. We have carried out a study of the efficiency of optical second-harmonic generation…
▽ More
Materials that exhibit high nonlinear optical (NLO) susceptibilities are considered as promising candidates for a wide range of photonic and electronic applications. Here we argue that the ferroelectric nematic (NF) materials have sufficient potentialities to become materials for the next-generation of NLO devices. We have carried out a study of the efficiency of optical second-harmonic generation in a prototype NF material, finding a nonlinear susceptibility of 5.6 pmV-1 in the transparent regime, one of the highest ever reported in ferroelectric liquid crystals. Given the fact that the studied molecule was not specifically designed for NLO applications we conclude there is still margin to obtain NF materials with enhanced properties that should allow their practical use.
△ Less
Submitted 11 December, 2021;
originally announced December 2021.
-
Extended space and time correlations in strongly magnetized plasmas
Authors:
Keith R. Vidal,
Scott D. Baalrud
Abstract:
Molecular dynamics simulations are used to show that strong magnetization significantly increases the space and time scales associated with interparticle correlations. The physical mechanism responsible is a channeling effect whereby particles are confined to move along narrow cylinders with a width characterized by the gyroradius and a length characterized by the collision mean free path. The pre…
▽ More
Molecular dynamics simulations are used to show that strong magnetization significantly increases the space and time scales associated with interparticle correlations. The physical mechanism responsible is a channeling effect whereby particles are confined to move along narrow cylinders with a width characterized by the gyroradius and a length characterized by the collision mean free path. The predominant interaction is $180^\circ$ collisions at the ends of the collision cylinders, resulting in a long-range correlation parallel to the magnetic field. Its influence is demonstrated via the dependence of the velocity autocorrelation functions and self-diffusion coefficients on the domain size and run time in simulations of the one-component plasma. A very large number of particles, and therefore domain size, must be used to resolve the long-range correlations, suggesting that the number of charged particles in the collection must increase in order to constitute a plasma. Correspondingly, this effect significantly delays the time it takes to reach a diffusive regime, in which the mean square displacement of particles increases linearly in time. This result presents challenges for connecting measurements in non-neutral and ultracold neutral plasma experiments, as well as molecular dynamics simulations, with fluid transport properties due to their finite size.
△ Less
Submitted 8 February, 2021;
originally announced February 2021.
-
Electromagnetic dipole moments of charged baryons with bent crystals at the LHC
Authors:
E. Bagli,
L. Bandiera,
G. Cavoto,
V. Guidi,
L. Henry,
D. Marangotto,
F. Martinez Vidal,
A. Mazzolari,
A. Merli,
N. Neri,
J. Ruiz Vidal
Abstract:
We propose a unique program of measurements of electric and magnetic dipole moments of charm, beauty and strange charged baryons at the LHC, based on the phenomenon of spin precession of channeled particles in bent crystals. Studies of crystal channeling and spin precession of positively- and negatively-charged particles are presented, along with feasibility studies and expected sensitivities for…
▽ More
We propose a unique program of measurements of electric and magnetic dipole moments of charm, beauty and strange charged baryons at the LHC, based on the phenomenon of spin precession of channeled particles in bent crystals. Studies of crystal channeling and spin precession of positively- and negatively-charged particles are presented, along with feasibility studies and expected sensitivities for the proposed experiment using a layout based on the LHCb detector.
△ Less
Submitted 10 February, 2018; v1 submitted 28 August, 2017;
originally announced August 2017.
-
Searches for the Violation of Pauli Exclusion Principle at LNGS in VIP(-2) experiment
Authors:
H Shi,
S. Bartalucci,
S. Bertolucci,
C. Berucci,
A. M. Bragadireanu,
M. Cargnelli,
A. Clozza,
C. Curceanu,
L. De Paolis,
S. Di Matteo,
A. d'Uffizi,
J. -P. Egger,
C. Guaraldo,
M. Iliescu,
T. Ishiwatari,
J. Marton,
M. Laubenstein,
E. Milotti,
D. Pietreanu,
K. Piscicchia,
T. Ponta,
A. Romero Vidal,
E. Sbardella,
A. Scordo,
D. L. Sirghi
, et al. (5 additional authors not shown)
Abstract:
The VIP (Violation of Pauli exclusion principle) experiment and its follow-up experiment VIP-2 at the Laboratori Nazionali del Gran Sasso (LNGS) search for X-rays from Cu atomic states that are prohibited by the Pauli Exclusion Principle (PEP). The candidate events, if they exist, will originate from the transition of a $2p$ orbit electron to the ground state which is already occupied by two elect…
▽ More
The VIP (Violation of Pauli exclusion principle) experiment and its follow-up experiment VIP-2 at the Laboratori Nazionali del Gran Sasso (LNGS) search for X-rays from Cu atomic states that are prohibited by the Pauli Exclusion Principle (PEP). The candidate events, if they exist, will originate from the transition of a $2p$ orbit electron to the ground state which is already occupied by two electrons. The present limit on the probability for PEP violation for electron is 4.7 $\times10^{-29}$ set by the VIP experiment. With upgraded detectors for high precision X-ray spectroscopy, the VIP-2 experiment will improve the sensitivity by two orders of magnitude.
△ Less
Submitted 21 January, 2016;
originally announced January 2016.
-
Recovery Time Measurements of Silicon Photomultipliers Using a Pulsed Laser
Authors:
L. Gruber,
S. E. Brunner,
C. Curceanu,
J. Marton,
A. Romero Vidal,
A. Scordo,
K. Suzuki,
O. Vazquez Doce
Abstract:
We performed an experimental study to determine the pixel recovery time of various Multi Pixel Photon Counters (MPPCs) in order to characterize their rate capability and double-hit resolution. The recovery time constant and its dependence on the operating voltage has been evaluated by measuring the photosensor response to two consecutive laser pulses with varying relative time differences of a few…
▽ More
We performed an experimental study to determine the pixel recovery time of various Multi Pixel Photon Counters (MPPCs) in order to characterize their rate capability and double-hit resolution. The recovery time constant and its dependence on the operating voltage has been evaluated by measuring the photosensor response to two consecutive laser pulses with varying relative time differences of a few ns (2-3 ns) up to some 100 ns using a waveform analysis technique. A Monte Carlo simulation tool is being developed to model the MPPC recovery process and interpret experimental data. In this context, the influence of after-pulsing, cross-talk and dark-noise on the recovery process can be studied.
△ Less
Submitted 23 October, 2015;
originally announced October 2015.
-
Measurement of the strong interaction induced shift and width of the 1s state of kaonic deuterium at J-PARC
Authors:
J. Zmeskal,
M. Sato,
S. Ajimura,
M. Bazzi,
G. Beer,
C. Berucci,
H. Bhang,
D. Bosnar,
M. Bragadireanu,
P. Buehler,
L. Busso,
M. Cargnelli,
S. Choi,
A. Clozza,
C. Curceanu,
A. D'uffizi,
S. Enomoto,
L. Fabbietti,
D. Faso,
C. Fiorini,
H. Fujioka,
F. Ghio,
R. Golser,
C. Guaraldo,
T. Hashimoto
, et al. (52 additional authors not shown)
Abstract:
The antikaon-nucleon interaction close to threshold provides crucial information on the interplay between spontaneous and explicit chiral symmetry breaking in low-energy QCD. In this context the importance of kaonic deuterium X-ray spectroscopy has been well recognized, but no experimental results have yet been obtained due to the difficulty of the measurement. We propose to measure the shift and…
▽ More
The antikaon-nucleon interaction close to threshold provides crucial information on the interplay between spontaneous and explicit chiral symmetry breaking in low-energy QCD. In this context the importance of kaonic deuterium X-ray spectroscopy has been well recognized, but no experimental results have yet been obtained due to the difficulty of the measurement. We propose to measure the shift and width of the kaonic deuterium 1s state with an accuracy of 60 eV and 140 eV respectively at J-PARC. These results together with the kaonic hydrogen data (KpX at KEK, DEAR and SIDDHARTA at DAFNE) will then permit the determination of values of both the isospin I=0 and I=1 antikaon-nucleon scattering lengths and will provide the most stringent constraints on the antikaon-nucleon interaction, promising a breakthrough. Refined Monte Carlo studies were performed, including the investigation of background suppression factors for the described setup. These studies have demonstrated the feasibility of determining the shift and width of the kaonic deuterium atom 1s state with the desired accuracy of 60 eV and 140 eV.
△ Less
Submitted 22 January, 2015;
originally announced January 2015.
-
Testing the Pauli Exclusion Principle for electrons at LNGS
Authors:
H. Shi,
S. Bartalucci,
S. Bertolucci,
C. Berucci,
A. M. Bragadireanu,
M. Cargnelli,
A. Clozza,
C. Curceanu,
L. De Paolis,
S. Di Matteo,
A. d'Uffizi,
J. -P. Egger,
C. Guaraldo,
M. Iliescu,
T. Ishiwatari,
J. Marton,
M. Laubenstein,
E. Milotti,
D. Pietreanu,
K. Piscicchia,
T. Ponta,
A. Romero Vidal,
E. Sbardella,
A. Scordo,
D. L. Sirghi
, et al. (5 additional authors not shown)
Abstract:
High-precision experiments have been done to test the Pauli exclusion principle (PEP) for electrons by searching for anomalous $K$-series X-rays from a Cu target supplied with electric current. With the highest sensitivity, the VIP (VIolation of Pauli Exclusion Principle) experiment set an upper limit at the level of $10^{-29}$ for the probability that an external electron captured by a Cu atom ca…
▽ More
High-precision experiments have been done to test the Pauli exclusion principle (PEP) for electrons by searching for anomalous $K$-series X-rays from a Cu target supplied with electric current. With the highest sensitivity, the VIP (VIolation of Pauli Exclusion Principle) experiment set an upper limit at the level of $10^{-29}$ for the probability that an external electron captured by a Cu atom can make the transition from the 2$p$ state to a 1$s$ state already occupied by two electrons. In a follow-up experiment at Gran Sasso, we aim to increase the sensitivity by two orders of magnitude. We show proofs that the proposed improvement factor is realistic based on the results from recent performance tests of the detectors we did at Laboratori Nazionali di Frascati (LNF).
△ Less
Submitted 7 May, 2014;
originally announced May 2014.
-
A GEM-based Time Projection Chamber for the AMADEUS experiment
Authors:
M. Poli Lener,
M. Bazzi,
G. Corradi,
C. Curceanu,
A. D'Uffizi,
C. Paglia,
E. Sbardella,
A. Scordo,
D. Tagnani,
A. Romero Vidal,
J. Zmeskal
Abstract:
In this paper we present the R&D activity on a new GEM-based TPC prototype for AMADEUS, a new experimental proposal at the DAΦNE Φ-factory at the Laboratori Nazionali di Frascati (INFN), aiming to perform measurements of the low-energy negative kaons interactions in nuclei. Such innovative detector will equip the inner part of the experiment in order to perfom a better reconstruction of the primar…
▽ More
In this paper we present the R&D activity on a new GEM-based TPC prototype for AMADEUS, a new experimental proposal at the DAΦNE Φ-factory at the Laboratori Nazionali di Frascati (INFN), aiming to perform measurements of the low-energy negative kaons interactions in nuclei. Such innovative detector will equip the inner part of the experiment in order to perfom a better reconstruction of the primary vertex and the secondary particles tracking. A 10x10 cm2 prototype with a drift gap up to 15 cm was realized and succesfully tested at the π M1 beam facility of the Paul Scherrer Institut (PSI) with low momentum hadrons. The measurements of the detector efficiency and spatial resolution have been performed. The results as a function of the gas gain, drift field, front-end electronic threshold and particle momentum are reported and discussed.
△ Less
Submitted 23 April, 2013;
originally announced April 2013.
-
Performances of a GEM-based Time Projection Chamber prototype for the AMADEUS experiment
Authors:
M. Poli Lener,
M. Bazzi,
G. Corradi,
C. Curceanu,
A. D'Uffizi,
C. Paglia,
A. Romero Vidal,
E. Sbardella,
A. Scordo,
D. Tagnani,
J. Zmeskal
Abstract:
A large number of high-energy and heavy-ion experiments successfully used Time Projection Chamber (TPC) as central tracker and particle identification detector. However, the performance requirements on TPC for new high-rate particle experiments greatly exceed the abilities of traditional TPC read out by multi-wire proportional chamber (MWPC). Gas Electron Multiplier (GEM) detector has great potent…
▽ More
A large number of high-energy and heavy-ion experiments successfully used Time Projection Chamber (TPC) as central tracker and particle identification detector. However, the performance requirements on TPC for new high-rate particle experiments greatly exceed the abilities of traditional TPC read out by multi-wire proportional chamber (MWPC). Gas Electron Multiplier (GEM) detector has great potential to improve TPC performances when used as amplification device. In this paper we present the R&D activity on a new GEM-based TPC detector built as a prototype for the inner part for AMADEUS, a new experimental proposal at the DAFNE collider at Laboratori Nazionali di Frascati (INFN), aiming to perform measurements of the low-energy negative kaons interactions in nuclei. In order to evaluate the GEM-TPC performances, a 10x10 cm2 prototype with a drift gap up to 15 cm has been realized. The detector was tested at the pM1 beam facility of the Paul Scherrer Institut (PSI) with low momentum pions and protons, without magnetic field. Drift properties of argonisobutane gas mixtures are measured and compared withMagboltz prediction. Detection efficiency and spatial resolution as a function of a large number of parameters, such as the gas gain, the drift field, the front-end electronic threshold and particle momentum, are illustrated and discussed. Particle identification capability and the measurement of the energy resolution in isobutane-based gas mixture are also reported.
△ Less
Submitted 13 February, 2013;
originally announced February 2013.
-
Characterization of a scintillating fibers read by MPPC detectors trigger prototype for the AMADEUS experiment
Authors:
A. Scordo,
M. Bazzi,
C. Berucci,
C. Curceanu,
A. D'Uffizi,
K. Piscicchia,
M. Poli Lener,
A. Romero Vidal,
E. Sbardella,
O. Vazquez Doce
Abstract:
Multi-Pixel Photon Counters (MPPC) consist of hundreds of micro silicon Avalanche PhotoDiodes (APD) working in Geiger mode. The high gain and the low noise, typical of these devices, together with their good performance in magnetic field, make them ideal readout detectors for scintillating fibers as trigger detectors in particle and nuclear physics experiments like AMADEUS, where such detectors ar…
▽ More
Multi-Pixel Photon Counters (MPPC) consist of hundreds of micro silicon Avalanche PhotoDiodes (APD) working in Geiger mode. The high gain and the low noise, typical of these devices, together with their good performance in magnetic field, make them ideal readout detectors for scintillating fibers as trigger detectors in particle and nuclear physics experiments like AMADEUS, where such detectors are planned to be used to trigger on charged kaon pairs. In order to investigate the detection efficiency of such a system, a prototype setup consisting of 32, 1 mm diameter scintillating fibers, arranged in two double layers of 16 fibers each, and read out by 64 MPPCs with an ad-hoc built readout electronics, was tested at the piM-1 line of the Paul Scherrer Institute (PSI) in Villigen, Switzerland. The detection efficiency and the trigger capability were measured on a beam containing protons, electrons, muons and pions with a momentum of 440 MeV/c. The measured average efficiency for protons for a double layer of scintillating fibers (96.9 +/-1.2%) represents a guarantee of the good performance of this system as a trigger for the AMADEUS experiment.
△ Less
Submitted 7 May, 2013; v1 submitted 30 January, 2013;
originally announced January 2013.
-
The K1.8BR spectrometer system at J-PARC
Authors:
Keizo Agari,
Shuhei Ajimura,
George Beer,
Hyoungchan Bhang,
Mario Bragadireanu,
Paul Buehler,
Luigi Busso,
Michael Cargnelli,
Seonho Choi,
Catalina Curceanu,
Shun Enomoto,
Diego Faso,
Hiroyuki Fujioka,
Yuya Fujiwara,
Tomokazu Fukuda,
Carlo Guaraldo,
Tadashi Hashimoto,
Ryugo S. Hayano,
Toshihiko Hiraiwa,
Erina Hirose,
Masaharu Ieiri,
Masami Iio,
Mihai Iliescu,
Kentaro Inoue,
Yosuke Ishiguro
, et al. (60 additional authors not shown)
Abstract:
A new spectrometer system was designed and constructed at the secondary beam line K1.8BR in the hadron hall of J-PARC to investigate $\bar K N$ interactions and $\bar K$-nuclear bound systems. The spectrometer consists of a high precision beam line spectrometer, a liquid $^3$He/$^4$He/D$_2$ target system, a Cylindrical Detector System that surrounds the target to detect the decay particles from th…
▽ More
A new spectrometer system was designed and constructed at the secondary beam line K1.8BR in the hadron hall of J-PARC to investigate $\bar K N$ interactions and $\bar K$-nuclear bound systems. The spectrometer consists of a high precision beam line spectrometer, a liquid $^3$He/$^4$He/D$_2$ target system, a Cylindrical Detector System that surrounds the target to detect the decay particles from the target region, and a neutron time-of-flight counter array located $\sim$15 m downstream from the target position. Details of the design, construction, and performance of the detector components are described.
△ Less
Submitted 21 November, 2012; v1 submitted 1 June, 2012;
originally announced June 2012.