Design and test of 704 MHz and 2.1 GHz normal conducting cavities for Low Energy RHIC electron Cooler
Authors:
S. Belomestnykh,
J. M. Brennan,
J. C. Brutus,
G. McIntyre,
K. Mernick,
C. Pai,
K. Smith,
T. Xin,
A. Zaltsman,
V. Veshcherevich
Abstract:
The Low Energy RHIC electron Cooler (LEReC) is currently under commissioning at BNL to improve RHIC luminosity for heavy ion beam energies below 10 GeV/nucleon. The linac of LEReC consists of a DC photoemission gun, one 704 MHz superconducting radio frequency (SRF) booster cavity, and three normal conducting cavities. It is designed to deliver a 1.6 MeV to 2.6 MeV electron beam, with peak-to-peak…
▽ More
The Low Energy RHIC electron Cooler (LEReC) is currently under commissioning at BNL to improve RHIC luminosity for heavy ion beam energies below 10 GeV/nucleon. The linac of LEReC consists of a DC photoemission gun, one 704 MHz superconducting radio frequency (SRF) booster cavity, and three normal conducting cavities. It is designed to deliver a 1.6 MeV to 2.6 MeV electron beam, with peak-to-peak momentum spread dp/p of less than 7e4. Two of the three normal conducting cavities will be used in LEReC for energy spread correction. A single-cell 704 MHz cavity for energy de-chir** and a three-cell 2.1 GHz third harmonic cavity for RF curvature correction. In this paper, we present the designs and RF test results of these two cavities.
△ Less
Submitted 5 April, 2018;
originally announced April 2018.
-
CBETA Design Report, Cornell-BNL ERL Test Accelerator
Authors:
G. H. Hoffstaetter,
D. Trbojevic,
C. Mayes,
N. Banerjee,
J. Barley,
I. Bazarov,
A. Bartnik,
J. S. Berg,
S. Brooks,
D. Burke,
J. Crittenden,
L. Cultrera,
J. Dobbins,
D. Douglas,
B. Dunham,
R. Eichhorn,
S. Full,
F. Furuta,
C. Franck,
R. Gallagher,
M. Ge,
C. Gulliford,
B. Heltsley,
D. Jusic,
R. Kaplan
, et al. (29 additional authors not shown)
Abstract:
This design report describes the construction plans for the world's first multi-pass SRF ERL. It is a 4-pass recirculating linac that recovers the beam's energy by 4 additional, decelerating passes. All beams are returned for deceleration in a single beam pipe with a large-momentum-aperture permanent magnet FFAG optics. Cornell University has been pioneering a new class of accelerators, Energy Rec…
▽ More
This design report describes the construction plans for the world's first multi-pass SRF ERL. It is a 4-pass recirculating linac that recovers the beam's energy by 4 additional, decelerating passes. All beams are returned for deceleration in a single beam pipe with a large-momentum-aperture permanent magnet FFAG optics. Cornell University has been pioneering a new class of accelerators, Energy Recovery Linacs (ERLs), with a new characteristic set of beam parameters. Technology has been prototyped that is essential for any high brightness electron ERL. This includes a DC electron source and an SRF injector Linac with world-record current and normalized brightness in a bunch train, a high-current linac cryomodule, and a high-power beam stop, and several diagnostics tools for high-current and high-brightness beams. All these are now being used to construct a novel one-cryomodule ERL in Cornell's Wilson Lab. Brookhaven National Laboratory (BNL) has designed a multi-turn ERL for eRHIC, where beam is transported more than 20 times around the 4km long RHIC tunnel. The number of transport lines is minimized by using two arcs with strongly-focusing permanent magnets that can control many beams of different energies. A collaboration between BNL and Cornell has been formed to investigate this multi-turn eRHIC ERL design by building a 4-turn, one-cryomodule ERL at Cornell. It also has a return loop built with strongly focusing permanent magnets and is meant to accelerate 40mA beam to 150MeV. This high-brightness beam will have applications beyond accelerator research, in industry, in nuclear physics, and in X-ray science.
△ Less
Submitted 13 June, 2017;
originally announced June 2017.
-
Thermocurrents and their Role in high Q Cavity Performance
Authors:
R. Eichhorn,
C. Daly,
F. Furuta,
A. Ganshyn,
D. Gonnella,
D. Hall,
V. Ho,
G. H. Hoffstaetter,
M. Liepe,
J. May-Mann,
T. O'Connell,
S. Posen,
P. Quigley,
J. Sears,
V. Veshcherevich
Abstract:
Over the past years it became evident that the quality factor of a superconducting cavity is not only determined by its surface preparation procedure, but is also influenced by the way the cavity is cooled down. Moreover, different data sets exists, some of them indicate that a slow cool-down through the critical temperature is favourable while other data states the exact opposite. Even so there w…
▽ More
Over the past years it became evident that the quality factor of a superconducting cavity is not only determined by its surface preparation procedure, but is also influenced by the way the cavity is cooled down. Moreover, different data sets exists, some of them indicate that a slow cool-down through the critical temperature is favourable while other data states the exact opposite. Even so there where speculations and some models about the role of thermo-currents and flux-pinning, the difference in behaviour remained a mystery. In this paper we will for the first time present a consistent theoretical model which we confirmed by data that describes the role of thermo-currents, driven by temperature gradients and material transitions. We will clearly show how they impact the quality factor of a cavity, discuss our findings, relate it to findings at other labs and develop mitigation strategies which especially addresses the issue of achieving high quality factors of so-called nitrogen doped cavities in horizontal test.
△ Less
Submitted 12 January, 2015; v1 submitted 19 November, 2014;
originally announced November 2014.
-
Nitrogen-Doped 9-Cell Cavity Performance in a Test Cryomodule for LCLS-II
Authors:
Dan Gonnella,
Ralf Eichhorn,
Fumio Furuta,
Mingqi Ge,
Daniel Hall,
Vivian Ho,
Georg Hoffstaetter,
Matthias Liepe,
Tim O'Connell,
Sam Posen,
Peter Quigley,
James Sears,
Vadim Veshcherevich,
Anna Grassellino,
Alexander Romanenko,
Dmitri Sergatskov
Abstract:
The superconducting RF linac for LCLS-II calls for 1.3 GHz 9-cell cavities with an average intrinsic quality factor Q0 of 2.7x10^10 at 2 K and 16 MV/m accelerating gradient. Two niobium 9-cell cavities, prepared with nitrogen-do** at Fermilab, were assembled into the Cornell Horizontal Test Cryomodule (HTC) to test cavity performance in a cryomodule that is very similar to a full LCLS-II cryomod…
▽ More
The superconducting RF linac for LCLS-II calls for 1.3 GHz 9-cell cavities with an average intrinsic quality factor Q0 of 2.7x10^10 at 2 K and 16 MV/m accelerating gradient. Two niobium 9-cell cavities, prepared with nitrogen-do** at Fermilab, were assembled into the Cornell Horizontal Test Cryomodule (HTC) to test cavity performance in a cryomodule that is very similar to a full LCLS-II cryomodule. The cavities met LCLS-II specifications with an average quench field of 17 MV/m and an average Q0 of 3x10^10. The sensitivity of the cavities' residual resistance to ambient magnetic field was determined to be 0.5 nOhm/mG during fast cool down. In two cool downs, a heater attached to one of the cavity beam tubes was used to induce large horizontal temperature gradients. Here we report on the results of these first tests of nitrogen-doped cavities in cryomodule, which provide critical information for the LCLS-II project.
△ Less
Submitted 13 November, 2014; v1 submitted 6 November, 2014;
originally announced November 2014.
-
Photocathode Behavior During High Current Running in the Cornell ERL Photoinjector
Authors:
Luca Cultrera,
Jared Maxson,
Ivan Bazarov,
Sergey Belomestnykh,
John Dobbins,
Bruce Dunham,
Siddharth Karkare,
Roger Kaplan,
Vaclav Kostroun,
Yulin Li,
Xianghong Liu,
Florian Löhl,
Karl Smolenski,
Zhi Zhao,
David Rice,
Peter Quigley,
Maury Tigner,
Vadim Veshcherevich,
Kenneth Finkelstein,
Darren Dale,
Benjamin Pichler
Abstract:
The Cornell University Energy Recovery Linac (ERL) photoinjector has recently demonstrated operation at 20 mA for approximately 8 hours, utilizing a multialkali photocathode deposited on a Si substrate. We describe the recipe for photocathode deposition, and will detail the parameters of the run. Post-run analysis of the photocathode indicates the presence of significant damage to the substrate, p…
▽ More
The Cornell University Energy Recovery Linac (ERL) photoinjector has recently demonstrated operation at 20 mA for approximately 8 hours, utilizing a multialkali photocathode deposited on a Si substrate. We describe the recipe for photocathode deposition, and will detail the parameters of the run. Post-run analysis of the photocathode indicates the presence of significant damage to the substrate, perhaps due to ion back-bombardment from the residual beamline gas. While the exact cause of the substrate damage remains unknown, we describe multiple surface characterization techniques (X-ray fluorescence spectroscopy, X-ray diffraction, atomic force and scanning electron microscopy) used to study the interesting morphological and crystallographic features of the photocathode surface after its use for high current beam production. Finally, we present a simple model of crystal damage due to ion back-bombardment, which agrees qualitatively with the distribution of damage on the substrate surface.
△ Less
Submitted 16 October, 2011;
originally announced October 2011.