-
Mediastinal lymph nodes segmentation using 3D convolutional neural network ensembles and anatomical priors guiding
Authors:
David Bouget,
André Pedersen,
Johanna Vanel,
Haakon O. Leira,
Thomas Langø
Abstract:
As lung cancer evolves, the presence of enlarged and potentially malignant lymph nodes must be assessed to properly estimate disease progression and select the best treatment strategy. Following the clinical guidelines, estimation of short-axis diameter and mediastinum station are paramount for correct diagnosis. A method for accurate and automatic segmentation is hence decisive for quantitatively…
▽ More
As lung cancer evolves, the presence of enlarged and potentially malignant lymph nodes must be assessed to properly estimate disease progression and select the best treatment strategy. Following the clinical guidelines, estimation of short-axis diameter and mediastinum station are paramount for correct diagnosis. A method for accurate and automatic segmentation is hence decisive for quantitatively describing lymph nodes. In this study, the use of 3D convolutional neural networks, either through slab-wise schemes or the leveraging of downsampled entire volumes, is investigated. Furthermore, the potential impact from simple ensemble strategies is considered. As lymph nodes have similar attenuation values to nearby anatomical structures, we suggest using the knowledge of other organs as prior information to guide the segmentation task. To assess the segmentation and instance detection performances, a 5-fold cross-validation strategy was followed over a dataset of 120 contrast-enhanced CT volumes. For the 1178 lymph nodes with a short-axis diameter $\geq10$ mm, our best performing approach reached a patient-wise recall of 92%, a false positive per patient ratio of 5, and a segmentation overlap of 80.5%. The method performs similarly well across all stations. Fusing a slab-wise and a full volume approach within an ensemble scheme generated the best performances. The anatomical priors guiding strategy is promising, yet a larger set than four organs appears needed to generate an optimal benefit. A larger dataset is also mandatory, given the wide range of expressions a lymph node can exhibit (i.e., shape, location, and attenuation), and contrast uptake variations.
△ Less
Submitted 11 February, 2021;
originally announced February 2021.
-
Infrastructure for Detector Research and Development towards the International Linear Collider
Authors:
J. Aguilar,
P. Ambalathankandy,
T. Fiutowski,
M. Idzik,
Sz. Kulis,
D. Przyborowski,
K. Swientek,
A. Bamberger,
M. Köhli,
M. Lupberger,
U. Renz,
M. Schumacher,
Andreas Zwerger,
A. Calderone,
D. G. Cussans,
H. F. Heath,
S. Mandry,
R. F. Page,
J. J. Velthuis,
D. Attié,
D. Calvet,
P. Colas,
X. Coppolani,
Y. Degerli,
E. Delagnes
, et al. (252 additional authors not shown)
Abstract:
The EUDET-project was launched to create an infrastructure for develo** and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infras…
▽ More
The EUDET-project was launched to create an infrastructure for develo** and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infrastructures for tracking detectors as well as for calorimetry.
△ Less
Submitted 23 January, 2012;
originally announced January 2012.
-
The T2K Experiment
Authors:
T2K Collaboration,
K. Abe,
N. Abgrall,
H. Aihara,
Y. Ajima,
J. B. Albert,
D. Allan,
P. -A. Amaudruz,
C. Andreopoulos,
B. Andrieu,
M. D. Anerella,
C. Angelsen,
S. Aoki,
O. Araoka,
J. Argyriades,
A. Ariga,
T. Ariga,
S. Assylbekov,
J. P. A. M. de André,
D. Autiero,
A. Badertscher,
O. Ballester,
M. Barbi,
G. J. Barker,
P. Baron
, et al. (499 additional authors not shown)
Abstract:
The T2K experiment is a long-baseline neutrino oscillation experiment. Its main goal is to measure the last unknown lepton sector mixing angle θ_{13} by observing ν_e appearance in a ν_μ beam. It also aims to make a precision measurement of the known oscillation parameters, Δm^{2}_{23} and sin^{2} 2θ_{23}, via ν_μ disappearance studies. Other goals of the experiment include various neutrino cross…
▽ More
The T2K experiment is a long-baseline neutrino oscillation experiment. Its main goal is to measure the last unknown lepton sector mixing angle θ_{13} by observing ν_e appearance in a ν_μ beam. It also aims to make a precision measurement of the known oscillation parameters, Δm^{2}_{23} and sin^{2} 2θ_{23}, via ν_μ disappearance studies. Other goals of the experiment include various neutrino cross section measurements and sterile neutrino searches. The experiment uses an intense proton beam generated by the J-PARC accelerator in Tokai, Japan, and is composed of a neutrino beamline, a near detector complex (ND280), and a far detector (Super-Kamiokande) located 295 km away from J-PARC. This paper provides a comprehensive review of the instrumentation aspect of the T2K experiment and a summary of the vital information for each subsystem.
△ Less
Submitted 8 June, 2011; v1 submitted 6 June, 2011;
originally announced June 2011.
-
Study of the interactions of pions in the CALICE silicon-tungsten calorimeter prototype
Authors:
C. Adloff,
Y. Karyotakis,
J. Repond,
J. Yu,
G. Eigen,
Y. Mikami,
N. K. Watson,
J. A. Wilson,
T. Goto,
G. Mavromanolakis,
M. A. Thomson,
D. R. Ward,
W. Yan,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki,
J. Apostolakis,
A. Ribon,
V. Uzhinskiy,
M. Benyamna,
C. Cârloganu,
F. Fehr,
P. Gay,
G. C. Blazey,
D. Chakraborty
, et al. (133 additional authors not shown)
Abstract:
A prototype silicon-tungsten electromagnetic calorimeter for an ILC detector was tested in 2007 at the CERN SPS test beam. Data were collected with electron and hadron beams in the energy range 8 to 80 GeV. The analysis described here focuses on the interactions of pions in the calorimeter. One of the main objectives of the CALICE program is to validate the Monte Carlo tools available for the…
▽ More
A prototype silicon-tungsten electromagnetic calorimeter for an ILC detector was tested in 2007 at the CERN SPS test beam. Data were collected with electron and hadron beams in the energy range 8 to 80 GeV. The analysis described here focuses on the interactions of pions in the calorimeter. One of the main objectives of the CALICE program is to validate the Monte Carlo tools available for the design of a full-sized detector. The interactions of pions in the Si-W calorimeter are therefore confronted with the predictions of various physical models implemented in the GEANT4 simulation framework.
△ Less
Submitted 28 April, 2010;
originally announced April 2010.
-
Construction and Commissioning of the CALICE Analog Hadron Calorimeter Prototype
Authors:
C. Adloff,
Y. Karyotakis,
J. Repond,
A. Brandt,
H. Brown,
K. De,
C. Medina,
J. Smith,
J. Li,
M. Sosebee,
A. White,
J. Yu,
T. Buanes,
G. Eigen,
Y. Mikami,
O. Miller,
N. K. Watson,
J. A. Wilson,
T. Goto,
G. Mavromanolakis,
M. A. Thomson,
D. R. Ward,
W. Yan,
D. Benchekroun,
A. Hoummada
, et al. (205 additional authors not shown)
Abstract:
An analog hadron calorimeter (AHCAL) prototype of 5.3 nuclear interaction lengths thickness has been constructed by members of the CALICE Collaboration. The AHCAL prototype consists of a 38-layer sandwich structure of steel plates and highly-segmented scintillator tiles that are read out by wavelength-shifting fibers coupled to SiPMs. The signal is amplified and shaped with a custom-designed ASIC.…
▽ More
An analog hadron calorimeter (AHCAL) prototype of 5.3 nuclear interaction lengths thickness has been constructed by members of the CALICE Collaboration. The AHCAL prototype consists of a 38-layer sandwich structure of steel plates and highly-segmented scintillator tiles that are read out by wavelength-shifting fibers coupled to SiPMs. The signal is amplified and shaped with a custom-designed ASIC. A calibration/monitoring system based on LED light was developed to monitor the SiPM gain and to measure the full SiPM response curve in order to correct for non-linearity. Ultimately, the physics goals are the study of hadron shower shapes and testing the concept of particle flow. The technical goal consists of measuring the performance and reliability of 7608 SiPMs. The AHCAL was commissioned in test beams at DESY and CERN. The entire prototype was completed in 2007 and recorded hadron showers, electron showers and muons at different energies and incident angles in test beams at CERN and Fermilab.
△ Less
Submitted 12 March, 2010;
originally announced March 2010.
-
Design and Electronics Commissioning of the Physics Prototype of a Si-W Electromagnetic Calorimeter for the International Linear Collider
Authors:
CALICE Collaboration,
J. Repond,
J. Yu,
C. M. Hawkes,
Y. Mikami,
O. Miller,
N. K. Watson,
J. A. Wilson,
G. Mavromanolakis,
M. A. Thomson,
D. R. Ward,
W. Yan,
F. Badaud,
D. Boumediene,
C. Carloganu,
R. Cornat,
P. Gay,
Ph. Gris,
S. Manen,
F. Morisseau,
L. Royer,
G. C. Blazey,
D. Chakraborty,
A. Dyshkant,
K. Francis
, et al. (92 additional authors not shown)
Abstract:
The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the electromagnetic calorimeter, the current baseline choice is a high granularity sampling calorimeter with tungsten as absorber and silicon detectors as sensitive material. A ``physics prototype'' has been constructed, consisting…
▽ More
The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the electromagnetic calorimeter, the current baseline choice is a high granularity sampling calorimeter with tungsten as absorber and silicon detectors as sensitive material. A ``physics prototype'' has been constructed, consisting of thirty sensitive layers. Each layer has an active area of 18x18 cm2 and a pad size of 1x1 cm2. The absorber thickness totals 24 radiation lengths. It has been exposed in 2006 and 2007 to electron and hadron beams at the DESY and CERN beam test facilities, using a wide range of beam energies and incidence angles. In this paper, the prototype and the data acquisition chain are described and a summary of the data taken in the 2006 beam tests is presented. The methods used to subtract the pedestals and calibrate the detector are detailed. The signal-over-noise ratio has been measured at 7.63 +/- 0.01. Some electronics features have been observed; these lead to coherent noise and crosstalk between pads, and also crosstalk between sensitive and passive areas. The performance achieved in terms of uniformity and stability is presented.
△ Less
Submitted 5 August, 2008; v1 submitted 29 May, 2008;
originally announced May 2008.