The sPHENIX Micromegas Outer Tracker
Authors:
S. Aune,
B. Azmoun,
A. Bonenfant,
S. Boose,
M. Bregant,
D. Cacace,
R. W. da Silva,
R. Feder,
A. Francisco,
C. Goblin,
A. Grabas,
J. S. Haggerty,
R. A. Hernandez,
H. D. H. Herrera,
J. Huang,
J. Kelsey,
I. Kotov,
J. Kuczewski,
I. Mandjavidze,
T. A. Martins,
J. Mead,
J. Mills,
A. Oskarsson,
H. Pereira Da Costa,
C. Pinkenburg
, et al. (15 additional authors not shown)
Abstract:
The sPHENIX Time Projection Chamber Outer Tracker (TPOT) is a Micromegas based detector. It is a part of the sPHENIX experiment that aims to facilitate the calibration of the Time Projection Chamber, in particular the correction of the time-averaged and beam-induced distortions of the electron drift. This paper describes the detector mission, setup, construction, installation, commissioning and pe…
▽ More
The sPHENIX Time Projection Chamber Outer Tracker (TPOT) is a Micromegas based detector. It is a part of the sPHENIX experiment that aims to facilitate the calibration of the Time Projection Chamber, in particular the correction of the time-averaged and beam-induced distortions of the electron drift. This paper describes the detector mission, setup, construction, installation, commissioning and performance during the first year of sPHENIX data taking.
△ Less
Submitted 21 March, 2024; v1 submitted 20 March, 2024;
originally announced March 2024.
-
Aging effects in the COMPASS hybrid GEM-Micromegas pixelized detectors
Authors:
Damien Neyret,
Philippe Abbon,
Marc Anfreville,
Vincent Andrieux,
Yann Bedfer,
Dominique Durand,
Sébastien Herlant,
Nicole d'Hose,
Fabienne Kunne,
Stephane Platchkov,
Florian Thibaud,
Michel Usseglio,
Maxence Vandenbroucke
Abstract:
Large-size hybrid and pixelized GEM-Micromegas gaseous detectors (40x40 cm$^2$ active area) were developed and installed in 2014 and 2015 for the COMPASS2 physics program which started at the same time. That program involved in particular two full years of Drell-Yan studies using a high-intensity pion beam on a thick polarized target. Although the detectors were placed behind a thick absorber, the…
▽ More
Large-size hybrid and pixelized GEM-Micromegas gaseous detectors (40x40 cm$^2$ active area) were developed and installed in 2014 and 2015 for the COMPASS2 physics program which started at the same time. That program involved in particular two full years of Drell-Yan studies using a high-intensity pion beam on a thick polarized target. Although the detectors were placed behind a thick absorber, they were exposed to an important flux of low energy neutrons and photons. The detectors were designed to drastically reduce the discharge rate, a major issue for non-resistive Micromegas in high hadron flux, by a factor of more than 100 compared to the former ones. A hybrid solution was chosen where a pre-amplifying GEM foil is placed 2 mm above the micromesh electrode. A pixelized readout was also added in the center of the detector, where the beam is going through, in order to track particles scattered at very low angles. The combination of the hybrid structure and the pixelized central readout allowed the detector to be operated in an environment with particle flux above 10 MHz/cm$^2$ with very good detection efficiencies and spatial resolution. The performance has remained stable since 2015 in terms of gain and resolution, showing the interest of hybrid structures associating a GEM foil to a Micromegas board to protect gaseous detectors against discharges and aging effects
△ Less
Submitted 20 June, 2024; v1 submitted 28 February, 2024;
originally announced February 2024.
-
Design, Construction, and Performance of the GEM based Radial Time Projection Chamber for the BONuS12 Experiment with CLAS12
Authors:
I. Albayrak,
S. Aune,
C. Ayerbe Gayoso,
P. Baron,
S. Bültmann,
G. Charles,
M. E. Christy,
G. Dodge,
N. Dzbenski,
R. Dupré,
K. Griffioen,
M. Hattawy,
Y. C. Hung,
N. Kalantarians,
S. Kuhn,
I. Mandjavidze,
A. Nadeeshani,
M. Ouillon,
P. Pandey,
D. Payette,
M. Pokhrel,
J. Poudel,
A. S. Tadepalli,
M. Vandenbroucke
Abstract:
A new radial time projection chamber based on Gas Electron Multiplier amplification layers was developed for the BONuS12 experiment in Hall B at Jefferson Lab. This device represents a significant evolutionary development over similar devices constructed for previous experiments, including cylindrical amplification layers constructed from single continuous GEM foils with less than 1\% dead area. P…
▽ More
A new radial time projection chamber based on Gas Electron Multiplier amplification layers was developed for the BONuS12 experiment in Hall B at Jefferson Lab. This device represents a significant evolutionary development over similar devices constructed for previous experiments, including cylindrical amplification layers constructed from single continuous GEM foils with less than 1\% dead area. Particular attention had been paid to producing excellent geometric uniformity of all electrodes, including the very thin metalized polyester film of the cylindrical cathode. This manuscript describes the design, construction, and performance of this new detector.
△ Less
Submitted 2 February, 2024;
originally announced February 2024.
-
ATHENA Detector Proposal -- A Totally Hermetic Electron Nucleus Apparatus proposed for IP6 at the Electron-Ion Collider
Authors:
ATHENA Collaboration,
J. Adam,
L. Adamczyk,
N. Agrawal,
C. Aidala,
W. Akers,
M. Alekseev,
M. M. Allen,
F. Ameli,
A. Angerami,
P. Antonioli,
N. J. Apadula,
A. Aprahamian,
W. Armstrong,
M. Arratia,
J. R. Arrington,
A. Asaturyan,
E. C. Aschenauer,
K. Augsten,
S. Aune,
K. Bailey,
C. Baldanza,
M. Bansal,
F. Barbosa,
L. Barion
, et al. (415 additional authors not shown)
Abstract:
ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its e…
▽ More
ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its expected performance in the most relevant physics channels. It includes an evaluation of detector technology choices, the technical challenges to realizing the detector and the R&D required to meet those challenges.
△ Less
Submitted 13 October, 2022;
originally announced October 2022.
-
Medica-Plus: a Micromegas-based proof-of-concept detector for sub-becquerel tritium activity assessment at the service of oncological research
Authors:
F. Jambon,
S. Aune,
P. Baron,
T. Benoit,
T. Bey,
D. Desforge,
E. Ferrer-Ribas,
A. Grabas,
M. Kebbiri,
I. Mandjavidze,
T. Papaevangelou,
M. Riallot,
M. Vandenbroucke,
F. Beau,
V. Dive,
C. Malgorn,
F. Malloggi,
A. Rousselot,
F. Carrel,
M. Trocmé
Abstract:
To fulfill needs in oncological research a new Micromegas detector has been developed to follow radiolabelled drugs in living organisms at the single cell level. This article describes the proof-of-concept of such a detector and compares its ability to detect and assess sub-becquerel \tritium~activities with a commercial $β$-imager
To fulfill needs in oncological research a new Micromegas detector has been developed to follow radiolabelled drugs in living organisms at the single cell level. This article describes the proof-of-concept of such a detector and compares its ability to detect and assess sub-becquerel \tritium~activities with a commercial $β$-imager
△ Less
Submitted 20 September, 2021;
originally announced September 2021.
-
The large inner Micromegas modules for the Atlas Muon Spectrometer Upgrade: construction, quality control and characterization
Authors:
J. Allard,
M. Anfreville,
N. Andari,
D. Attié,
S. Aune,
H. Bachacou,
F. Balli,
F. Bauer,
J. Bennet,
T. Benoit,
J. Beltramelli,
H. Bervas,
T. Bey,
S. Bouaziz,
M. Boyer,
T. Challey,
T. Chevalérias,
X. Copollani,
J. Costa,
G. Cara,
G. Decock,
F. Deliot,
D. Denysiuk,
D. Desforge,
G. Disset
, et al. (49 additional authors not shown)
Abstract:
The steadily increasing luminosity of the LHC requires an upgrade with high-rate and high-resolution detector technology for the inner end cap of the ATLAS muon spectrometer: the New Small Wheels (NSW). In order to achieve the goal of precision tracking at a hit rate of about 15 kHz/cm$^2$ at the inner radius of the NSW, large area Micromegas quadruplets with 100\,\microns spatial resolution per p…
▽ More
The steadily increasing luminosity of the LHC requires an upgrade with high-rate and high-resolution detector technology for the inner end cap of the ATLAS muon spectrometer: the New Small Wheels (NSW). In order to achieve the goal of precision tracking at a hit rate of about 15 kHz/cm$^2$ at the inner radius of the NSW, large area Micromegas quadruplets with 100\,\microns spatial resolution per plane have been produced. % IRFU, from the CEA research center of Saclay, is responsible for the production and validation of LM1 Micromegas modules. The construction, production, qualification and validation of the largest Micromegas detectors ever built are reported here. Performance results under cosmic muon characterisation will also be discussed.
△ Less
Submitted 28 May, 2021;
originally announced May 2021.
-
Science Requirements and Detector Concepts for the Electron-Ion Collider: EIC Yellow Report
Authors:
R. Abdul Khalek,
A. Accardi,
J. Adam,
D. Adamiak,
W. Akers,
M. Albaladejo,
A. Al-bataineh,
M. G. Alexeev,
F. Ameli,
P. Antonioli,
N. Armesto,
W. R. Armstrong,
M. Arratia,
J. Arrington,
A. Asaturyan,
M. Asai,
E. C. Aschenauer,
S. Aune,
H. Avagyan,
C. Ayerbe Gayoso,
B. Azmoun,
A. Bacchetta,
M. D. Baker,
F. Barbosa,
L. Barion
, et al. (390 additional authors not shown)
Abstract:
This report describes the physics case, the resulting detector requirements, and the evolving detector concepts for the experimental program at the Electron-Ion Collider (EIC). The EIC will be a powerful new high-luminosity facility in the United States with the capability to collide high-energy electron beams with high-energy proton and ion beams, providing access to those regions in the nucleon…
▽ More
This report describes the physics case, the resulting detector requirements, and the evolving detector concepts for the experimental program at the Electron-Ion Collider (EIC). The EIC will be a powerful new high-luminosity facility in the United States with the capability to collide high-energy electron beams with high-energy proton and ion beams, providing access to those regions in the nucleon and nuclei where their structure is dominated by gluons. Moreover, polarized beams in the EIC will give unprecedented access to the spatial and spin structure of the proton, neutron, and light ions. The studies leading to this document were commissioned and organized by the EIC User Group with the objective of advancing the state and detail of the physics program and develo** detector concepts that meet the emerging requirements in preparation for the realization of the EIC. The effort aims to provide the basis for further development of concepts for experimental equipment best suited for the science needs, including the importance of two complementary detectors and interaction regions.
This report consists of three volumes. Volume I is an executive summary of our findings and developed concepts. In Volume II we describe studies of a wide range of physics measurements and the emerging requirements on detector acceptance and performance. Volume III discusses general-purpose detector concepts and the underlying technologies to meet the physics requirements. These considerations will form the basis for a world-class experimental program that aims to increase our understanding of the fundamental structure of all visible matter
△ Less
Submitted 26 October, 2021; v1 submitted 8 March, 2021;
originally announced March 2021.
-
A Comparative Study of Straight-Strip and Zigzag-Interleaved Anode Patterns for MPGD Readouts
Authors:
C. Perez-Lara,
S. Aune,
B. Azmoun,
K. Dehmelt,
A. Deshpande,
W. Fan,
P. Garg,
T. K. Hemmick,
M. Kebbiri,
A. Kiselev,
I. Mandjavidze,
M. L. Purschke,
M. Revolle,
M. Vandenbroucke,
C. Woody
Abstract:
Due to their simplicity and versatility of design, straight strip or rectangular pad anode structures are frequently employed with micro-pattern gas detectors to reconstruct high precision space points for various tracking applications. The particle impact point is typically determined by interpolating the charge collected by several neighboring pads. However, to effectively extract the inherent p…
▽ More
Due to their simplicity and versatility of design, straight strip or rectangular pad anode structures are frequently employed with micro-pattern gas detectors to reconstruct high precision space points for various tracking applications. The particle impact point is typically determined by interpolating the charge collected by several neighboring pads. However, to effectively extract the inherent positional information, the lateral spacing of the straight pads must be significantly smaller than the extent of the charge cloud. In contrast, highly interleaved anode patterns, such as zigzags, can adequately sample the charge with a pitch comparable to the size of the charge cloud or even larger. This has the considerable advantage of providing the same performance while requiring far fewer instrumented channels. Additionally, the geometric parameters defining such zigzag structures may be tuned to provide a uniform detector response without the need for so-called pad response functions, while simultaneously maintaining excellent position resolution. We have measured the position resolution of a variety of zigzag shaped anode patterns optimized for various MPGDs, including GEM, Micromegas, and micro-RWELL and compared this performance to the same detectors equipped with straight pads of varying pitch. We report on the performance results of each readout structure, evaluated under identical conditions in a test beam.
△ Less
Submitted 28 January, 2021;
originally announced January 2021.
-
DMAPS Monopix developments in large and small electrode designs
Authors:
Christian Bespin,
Marlon Barbero,
Pierre Barrillon,
Ivan Berdalovic,
Siddharth Bhat,
Patrick Breugnon,
Ivan Caicedo,
Roberto Cardella,
Zongde Chen,
Yavuz Degerli,
Jochen Dingfelder,
Leyre Flores Sanz de Acedo,
Stephanie Godiot,
Fabrice Guilloux,
Toko Hirono,
Tomasz Hemperek,
Fabian Hügging,
Hans Krüger,
Thanushan Kugathasan,
Cesar Augusto Marin Tobon,
Konstantinos Moustakas,
Patrick Pangaud,
Heinz Pernegger,
Francesco Piro,
Petra Riedler
, et al. (8 additional authors not shown)
Abstract:
LF-Monopix1 and TJ-Monopix1 are depleted monolithic active pixel sensors (DMAPS) in 150 nm LFoundry and 180 nm TowerJazz CMOS technologies respectively. They are designed for usage in high-rate and high-radiation environments such as the ATLAS Inner Tracker at the High-Luminosity Large Hadron Collider (HL-LHC). Both chips are read out using a column-drain readout architecture. LF-Monopix1 follows…
▽ More
LF-Monopix1 and TJ-Monopix1 are depleted monolithic active pixel sensors (DMAPS) in 150 nm LFoundry and 180 nm TowerJazz CMOS technologies respectively. They are designed for usage in high-rate and high-radiation environments such as the ATLAS Inner Tracker at the High-Luminosity Large Hadron Collider (HL-LHC). Both chips are read out using a column-drain readout architecture. LF-Monopix1 follows a design with large charge collection electrode where readout electronics are placed inside. Generally, this offers a homogeneous electrical field in the sensor and short drift distances. TJ-Monopix1 employs a small charge collection electrode with readout electronics separated from the electrode and an additional n-type implant to achieve full depletion of the sensitive volume. This approach offers a low sensor capacitance and therefore low noise and is typically implemented with small pixel size. Both detectors have been characterized before and after irradiation using lab tests and particle beams.
△ Less
Submitted 9 July, 2020; v1 submitted 3 June, 2020;
originally announced June 2020.
-
Radiation hard DMAPS pixel sensors in 150nm CMOS technology for operation at LHC
Authors:
M. Barbero,
P. Barrillon,
C. Bespin,
S. Bhat,
P. Breugnon,
I. Caicedo,
Z. Chen,
Y. Degerli,
J. Dingfelder,
S. Godiot,
F. Guilloux,
T. Hemperek,
T. Hirono,
F. Hügging,
H. Krüger,
K. Moustakas,
A. Ouraou,
P. Pangaud,
I. Peric,
D-L. Pohl,
P. Rymaszewski,
P. Schwemling,
M. Vandenbroucke,
T. Wang,
N. Wermes
Abstract:
Monolithic Active Pixel Sensors (MAPS) have been developed since the late 1990s employing silicon substrate with a thin epitaxial layer in which deposited charge is collected by disordered diffusion rather than by drift in an electric field. As a consequence the signal is small and slow, and the radiation tolerance is below the requirements for LHC experiments by factors of 100 to 1000. We develop…
▽ More
Monolithic Active Pixel Sensors (MAPS) have been developed since the late 1990s employing silicon substrate with a thin epitaxial layer in which deposited charge is collected by disordered diffusion rather than by drift in an electric field. As a consequence the signal is small and slow, and the radiation tolerance is below the requirements for LHC experiments by factors of 100 to 1000. We developed fully depleted (D)MAPS pixel sensors employing a 150 nm CMOS technology and using a high resistivity substrate as well as a high biasing voltage. The development has been carried out in three subsequent iterations, from prototypes to a large pixel matrix comprising a complete readout architecture suitable for LHC operation. Full CMOS electronics is embedded in large deep n-wells which at the same time serve as collection nodes (large electrode design). The devices have been intensively characterized before and after irradiation employing lab tests as well as particle beams. The devices can cope with particle rates seen by the innermost pixel detectors of the LHC pp-experiments or as seen by the outer pixel layers of the planned HL-LHC upgrade. They are radiation hard to particle fluences of at least $10^{15}~\mathrm{n_{eq}/cm^2}$ and total ionization doses of at least 50 Mrad.
△ Less
Submitted 25 May, 2020; v1 submitted 4 November, 2019;
originally announced November 2019.
-
The Monopix chips: Depleted monolithic active pixel sensors with a column-drain read-out architecture for the ATLAS Inner Tracker upgrade
Authors:
Ivan Caicedo,
Marlon Barbero,
Pierre Barrillon,
Ivan Berdalovic,
Siddharth Bhat,
Christian Bespin,
Patrick Breugnon,
Roberto Cardella,
Zongde Chen,
Yavuz Degerli,
Jochen Dingfelder,
Stephanie Godiot,
Fabrice Guilloux,
Toko Hirono,
Tomasz Hemperek,
Fabian Hügging,
Hans Krüger,
Thanushan Kugathasan,
Konstantinos Moustakas,
Patrick Pangaud,
Heinz Pernegger,
David-Leon Pohl,
Petra Riedler,
Alexandre Rozanov,
Piotr Rymaszewski
, et al. (5 additional authors not shown)
Abstract:
Two different depleted monolithic CMOS active pixel sensor (DMAPS) prototypes with a fully synchronous column-drain read-out architecture were designed and tested: LF-Monopix and TJ-Monopix. These chips are part of a R&D effort towards a suitable implementation of a CMOS DMAPS for the HL-LHC ATLAS Inner Tracker. LF-Monopix was developed using a 150nm CMOS process on a highly resistive substrate (>…
▽ More
Two different depleted monolithic CMOS active pixel sensor (DMAPS) prototypes with a fully synchronous column-drain read-out architecture were designed and tested: LF-Monopix and TJ-Monopix. These chips are part of a R&D effort towards a suitable implementation of a CMOS DMAPS for the HL-LHC ATLAS Inner Tracker. LF-Monopix was developed using a 150nm CMOS process on a highly resistive substrate (>2 k$Ω\,$cm), while TJ-Monopix was fabricated using a modified 180 nm CMOS process with a 1 k$Ω\,$cm epi-layer for depletion. The chips differ in their front-end design, biasing scheme, pixel pitch, dimensions of the collecting electrode relative to the pixel size (large and small electrode design, respectively) and the placement of read-out electronics within such electrode. Both chips were operational after thinning down to 100 $\mathrmμ$m and additional back-side processing in LF-Monopix for total bulk depletion. The results in this work include measurements of their leakage current, noise, threshold dispersion, response to minimum ionizing particles and efficiency in test beam campaigns. In addition, the outcome from measurements after irradiation with neutrons up to a dose of $1\times10^{15}\,\mathrm{n_{eq} / cm}^{2}$ and its implications for future designs are discussed.
△ Less
Submitted 25 April, 2019; v1 submitted 10 February, 2019;
originally announced February 2019.
-
CMOS Monolithic Pixel Sensors based on the Column-Drain Architecture for the HL-LHC Upgrade
Authors:
K. Moustakas,
M. Barbero,
I. Berdalovic,
C. Bespin,
P. Breugnon,
I. Caicedo,
R. Cardella,
Y. Degerli,
N. Egidos Plaja,
S. Godiot,
F. Guilloux,
T. Hemperek,
T. Hirono,
H. Krueger,
T. Kugathasan,
C. A. Marin Tobon,
P. Pangaud,
H. Pernegger,
E. J. Schioppa,
W. Snoeys,
M. Vandenbroucke,
T. Wang,
N. Wermes
Abstract:
Depleted Monolithic Active Pixel Sensors (DMAPS) constitute a promising low cost alternative for the outer layers of the ATLAS experiment Inner Tracker (ITk). Realizations in modern, high resistivity CMOS technologies enhance their radiation tolerance by achieving substantial depletion of the sensing volume. Two DMAPS prototypes that use the same "column-drain" readout architecture and are based o…
▽ More
Depleted Monolithic Active Pixel Sensors (DMAPS) constitute a promising low cost alternative for the outer layers of the ATLAS experiment Inner Tracker (ITk). Realizations in modern, high resistivity CMOS technologies enhance their radiation tolerance by achieving substantial depletion of the sensing volume. Two DMAPS prototypes that use the same "column-drain" readout architecture and are based on different sensor implementation concepts named LF-Monopix and TJ-Monopix have been developed for the High Luminosity upgrade of the Large Hardon Collider (HL-LHC).
LF-Monopix was fabricated in the LFoundry 150 nm technology and features pixel size of $50x250~μm^{2}$ and large collection electrode opted for high radiation tolerance. Detection efficiency up to 99\% has been measured after irradiation to $1\cdot10^{15}~n_{eq}/cm^{2}$. TJ-Monopix is a large scale $(1x2~cm^{2})$ prototype featuring pixels of $36x40~μm^{2}$ size. It was fabricated in a novel TowerJazz 180 nm modified process that enables full depletion of the sensitive layer, while employing a small collection electrode that is less sensitive to crosstalk. The resulting small sensor capacitance ($<=3~fF$) is exploited by a compact, low power front end optimized to meet the 25ns timing requirement. Measurement results demonstrate the sensor performance in terms of Equivalent Noise Charge (ENC) $\approx11e^{-}$, threshold $\approx300~e^-$, threshold dispersion $\approx30~e^-$ and total power consumption lower than $120~mW/cm^2$.
△ Less
Submitted 10 September, 2018;
originally announced September 2018.
-
Characterization of a depleted monolithic pixel sensors in 150 nm CMOS technology for the ATLAS Inner Tracker upgrade
Authors:
F. J. Iguaz,
F. Balli,
M. Barbero,
S. Bhat,
P. Breugnon,
I. Caicedo,
Z. Chen,
Y. Degerli,
S. Godiot,
F. Guilloux,
C. Guyot,
T. Hemperek,
T. Hirono,
H. Krüger,
J. P. Meyer,
A. Ouraou,
P. Pangaud,
P. Rymaszewski,
P. Schwemling,
M. Vandenbroucke,
T. Wang,
N. Wermes
Abstract:
This work presents a depleted monolithic active pixel sensor (DMAPS) prototype manufactured in the LFoundry 150\,nm CMOS process. DMAPS exploit high voltage and/or high resistivity inclusion of modern CMOS technologies to achieve substantial depletion in the sensing volume. The described device, named LF-Monopix, was designed as a proof of concept of a fully monolithic sensor capable of operating…
▽ More
This work presents a depleted monolithic active pixel sensor (DMAPS) prototype manufactured in the LFoundry 150\,nm CMOS process. DMAPS exploit high voltage and/or high resistivity inclusion of modern CMOS technologies to achieve substantial depletion in the sensing volume. The described device, named LF-Monopix, was designed as a proof of concept of a fully monolithic sensor capable of operating in the environment of outer layers of the ATLAS Inner Tracker upgrade in 2025 for the High Luminosity Large Hadron Collider (HL-LHC). This type of devices has a lower production cost and lower material budget compared to presently used hybrid designs. In this work, the chip architecture will be described followed by the characterization of the different pre-amplifier and discriminator flavors with an external injection signal and an iron source (5.9\,keV x-rays).
△ Less
Submitted 12 June, 2018;
originally announced June 2018.
-
Depleted Fully Monolithic Active CMOS Pixel Sensors (DMAPS) in High Resistivity 150~nm Technology for LHC
Authors:
Toko Hirono,
Marlon Barbero,
Pierre Barrillon,
Siddharth Bhat,
Patrick Breugnon,
Ivan Caicedo,
Zongde Chen,
Michael Daas,
Yavuz Degerli,
Fabrice Guilloux,
Tomasz Hemperek,
Fabian Hugging,
Hans Kruger,
Patrick Pangaud,
Piotr Rymaszewski,
Philippe Schwemling,
Maxence Vandenbroucke,
Tianyang Wang,
Norbert Wermes
Abstract:
Depleted monolithic CMOS active pixel sensors (DMAPS) have been developed in order to demonstrate their suitability as pixel detectors in the outer layers of a toroidal LHC apparatus inner tracker (ATLAS ITk) pixel detector in the high-luminosity large hadron collider (HL-LHC). Two prototypes have been fabricated using 150 nm CMOS technology on high resistivity (> 2 k$Ω$ $cm^2$) wafers. The chip s…
▽ More
Depleted monolithic CMOS active pixel sensors (DMAPS) have been developed in order to demonstrate their suitability as pixel detectors in the outer layers of a toroidal LHC apparatus inner tracker (ATLAS ITk) pixel detector in the high-luminosity large hadron collider (HL-LHC). Two prototypes have been fabricated using 150 nm CMOS technology on high resistivity (> 2 k$Ω$ $cm^2$) wafers. The chip size is equivalent to that of the current ATLAS pixel detector readout chip. One of the prototypes is used for detailed characterization of the sensor and the analog readout of the DMAPS. The other is a fully monolithic DMAPS including fast readout digital logic that handles the required hit rate. In order to yield a strong homogeneous electric field within the sensor volume, thinning of the wafer was tested. The prototypes were irradiated with X-ray up to a total ionization dose (TID) of 50 Mrad and with neutrons up to non-ionizing energy loss (NIEL) of $10^{15}$ $n_{eq}/cm^2$. The analog readout circuitry maintained its performance after TID irradiation, and the hit-efficiency at > $10^7$ noise occupancy was as high as 98.9 % after NIEL irradiation.
△ Less
Submitted 25 March, 2018;
originally announced March 2018.
-
Development of depleted monolithic pixel sensors in 150 nm CMOS technology for the ATLAS Inner Tracker upgrade
Authors:
Piotr Rymaszewski,
Marlon Barbero,
Siddharth Bhat,
Patrick Breugnon,
Ivan Caicedo,
Zongde Chen,
Yavuz Degerli,
Stephanie Godiot,
Fabrice Guilloux,
Claude Guyot,
Tomasz Hemperek,
Toko Hirono,
Fabian Hügging,
Hans Krüger,
Mohamed Lachkar,
Patrick Pangaud,
Alexandre Rozanov,
Philippe Schwemling,
Maxence Vandenbroucke,
Tianyang Wang,
Norbert Wermes
Abstract:
This work presents a depleted monolithic active pixel sensor (DMAPS) prototype manufactured in the LFoundry 150 nm CMOS process. The described device, named LF-Monopix, was designed as a proof of concept of a fully monolithic sensor capable of operating in the environment of outer layers of the ATLAS Inner Tracker upgrade for the High Luminosity Large Hadron Collider (HL-LHC). Implementing such a…
▽ More
This work presents a depleted monolithic active pixel sensor (DMAPS) prototype manufactured in the LFoundry 150 nm CMOS process. The described device, named LF-Monopix, was designed as a proof of concept of a fully monolithic sensor capable of operating in the environment of outer layers of the ATLAS Inner Tracker upgrade for the High Luminosity Large Hadron Collider (HL-LHC). Implementing such a device in the detector module will result in a lower production cost and lower material budget compared to the presently used hybrid designs. In this paper the chip architecture will be described followed by the simulation and measurement results.
△ Less
Submitted 15 November, 2017; v1 submitted 3 November, 2017;
originally announced November 2017.
-
A Large Ungated TPC with GEM Amplification
Authors:
M. Berger,
M. Ball,
L. Fabbietti,
B. Ketzer,
R. Arora,
R. Beck,
F. Böhmer,
J. -C. Chen,
F. Cusanno,
S. Dørheim,
J. Hehner,
N. Herrmann,
C. Höppner,
D. Kaiser,
M. Kis,
V. Kleipa,
I. Konorov,
J. Kunkel,
N. Kurz,
Y. Leifels,
P. Müllner,
R. Münzer,
S. Neubert,
J. Rauch,
C. J. Schmidt
, et al. (6 additional authors not shown)
Abstract:
A Time Projection Chamber (TPC) is an ideal device for the detection of charged particle tracks in a large volume covering a solid angle of almost $4π$. The high density of hits on a given particle track facilitates the task of pattern recognition in a high-occupancy environment and in addition provides particle identification by measuring the specific energy loss for each track. For these reasons…
▽ More
A Time Projection Chamber (TPC) is an ideal device for the detection of charged particle tracks in a large volume covering a solid angle of almost $4π$. The high density of hits on a given particle track facilitates the task of pattern recognition in a high-occupancy environment and in addition provides particle identification by measuring the specific energy loss for each track. For these reasons, TPCs with Multiwire Proportional Chamber (MWPC) amplification have been and are widely used in experiments recording heavy-ion collisions. A significant drawback, however, is the large dead time of the order of 1 ms per event generated by the use of a gating grid, which is mandatory to prevent ions created in the amplification region from drifting back into the drift volume, where they would severely distort the drift path of subsequent tracks. For experiments with higher event rates this concept of a conventional TPC operating with a triggered gating grid can therefore not be applied without a significant loss of data. A continuous readout of the signals is the more appropriate way of operation. This, however, constitutes a change of paradigm with considerable challenges to be met concerning the amplification region, the design and bandwidth of the readout electronics, and the data handling. A mandatory prerequisite for such an operation is a sufficiently good suppression of the ion backflow from the avalanche region, which otherwise limits the tracking and particle identification capabilities of such a detector. Gas Electron Multipliers (GEM) are a promising candidate to combine excellent spatial resolution with an intrinsic suppression of ions. In this paper we describe the design, construction and the commissioning of a large TPC with GEM amplification and without gating grid (GEM-TPC).
△ Less
Submitted 16 February, 2017;
originally announced February 2017.
-
Space-Charge Effects in an Ungated GEM-based TPC
Authors:
F. V. Böhmer,
M. Ball,
S. Dørheim,
C. Höppner,
B. Ketzer,
I. Konorov,
S. Neubert,
S. Paul,
J. Rauch,
M. Vandenbroucke
Abstract:
A fundamental limit to the application of Time Projection Chambers (TPCs) in high-rate experiments is the accumulation of slowly drifting ions in the active gas volume, which compromises the homogeneity of the drift field and hence the detector resolution. Conventionally, this problem is overcome by the use of ion-gating structures. This method, however, introduces large dead times and restricts t…
▽ More
A fundamental limit to the application of Time Projection Chambers (TPCs) in high-rate experiments is the accumulation of slowly drifting ions in the active gas volume, which compromises the homogeneity of the drift field and hence the detector resolution. Conventionally, this problem is overcome by the use of ion-gating structures. This method, however, introduces large dead times and restricts trigger rates to a few hundred per second. The ion gate can be eliminated from the setup by the use of Gas Electron Multiplier (GEM) foils for gas amplification, which intrinsically suppress the backflow of ions. This makes the continuous operation of a TPC at high rates feasible.
In this work, Monte Carlo simulations of the buildup of ion space charge in a GEM-based TPC and the correction of the resulting drift distortions are discussed, based on realistic numbers for the ion backflow in a triple-GEM amplification stack. A TPC in the future PANDA experiment at FAIR, in which antiproton-proton interaction rates up to 2 x 10^7 per second will be reached, serves as an example for the experimental environment. The simulations show that space charge densities up to 65 fC per cubic cm are reached, leading to electron drift distortions of up to 10 mm. The application of a laser calibration system to correct these distortions is investigated. Based on full simulations of the detector physics and response, we show that it is possible to correct for the drift distortions and to maintain the good momentum resolution of the GEM-TPC.
△ Less
Submitted 3 September, 2012;
originally announced September 2012.
-
Technical Design Report for the: PANDA Micro Vertex Detector
Authors:
PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
Q. Wang,
H. Xu,
M. Albrecht,
J. Becker,
K. Eickel,
F. Feldbauer,
M. Fink,
P. Friedel,
F. H. Heinsius,
T. Held,
H. Koch,
B. Kopf,
M. Leyhe,
C. Motzko,
M. Pelizäus,
J. Pychy
, et al. (436 additional authors not shown)
Abstract:
This document illustrates the technical layout and the expected performance of the Micro Vertex Detector (MVD) of the PANDA experiment. The MVD will detect charged particles as close as possible to the interaction zone. Design criteria and the optimisation process as well as the technical solutions chosen are discussed and the results of this process are subjected to extensive Monte Carlo physics…
▽ More
This document illustrates the technical layout and the expected performance of the Micro Vertex Detector (MVD) of the PANDA experiment. The MVD will detect charged particles as close as possible to the interaction zone. Design criteria and the optimisation process as well as the technical solutions chosen are discussed and the results of this process are subjected to extensive Monte Carlo physics studies. The route towards realisation of the detector is outlined.
△ Less
Submitted 10 August, 2012; v1 submitted 27 July, 2012;
originally announced July 2012.
-
Technical Design Study for the PANDA Time Projection Chamber
Authors:
M. Ball,
F. V. Böhmer,
S. Dørheim,
C. Höppner,
B. Ketzer,
I. Konorov,
S. Neubert,
S. Paul,
J. Rauch,
S. Uhl,
M. Vandenbroucke,
M. Berger,
J. -C. Berger-Chen,
F. Cusanno,
L. Fabbietti,
R. Münzer,
R. Arora,
J. Frühauf,
M. Kiš,
Y. Leifels,
V. Kleipa,
J. Hehner,
J. Kunkel,
N. Kurz,
K. Peters
, et al. (16 additional authors not shown)
Abstract:
This document illustrates the technical layout and the expected performance of a Time Projection Chamber as the central tracking system of the PANDA experiment. The detector is based on a continuously operating TPC with Gas Electron Multiplier (GEM) amplification.
This document illustrates the technical layout and the expected performance of a Time Projection Chamber as the central tracking system of the PANDA experiment. The detector is based on a continuously operating TPC with Gas Electron Multiplier (GEM) amplification.
△ Less
Submitted 29 June, 2012;
originally announced July 2012.
-
New pixelized Micromegas detector with low discharge rate for the COMPASS experiment
Authors:
Damien Neyret,
Philippe Abbon,
Marc Anfreville,
Yann Bedfer,
Etienne Burtin,
Christophe Coquelet,
Nicole d'Hose,
Daniel Desforge,
Arnaud Giganon,
Didier Jourde,
Fabienne Kunne,
Alain Magnon,
Nour Makke,
Claude Marchand,
Bernard Paul,
Stéphane Platchkov,
Florian Thibaud,
Michel Usseglio,
Maxence Vandenbroucke
Abstract:
New Micromegas (Micro-mesh gaseous detectors) are being developed in view of the future physics projects planned by the COMPASS collaboration at CERN. Several major upgrades compared to present detectors are being studied: detectors standing five times higher luminosity with hadron beams, detection of beam particles (flux up to a few hundred of kHz/mm^{2}, 10 times larger than for the present Micr…
▽ More
New Micromegas (Micro-mesh gaseous detectors) are being developed in view of the future physics projects planned by the COMPASS collaboration at CERN. Several major upgrades compared to present detectors are being studied: detectors standing five times higher luminosity with hadron beams, detection of beam particles (flux up to a few hundred of kHz/mm^{2}, 10 times larger than for the present Micromegas detectors) with pixelized read-out in the central part, light and integrated electronics, and improved robustness. Two solutions of reduction of discharge impact have been studied, with Micromegas detectors using resistive layers and using an additional GEM foil. Performance of such detectors has also been measured. A large size prototypes with nominal active area and pixelized read-out has been produced and installed at COMPASS in 2010. In 2011 prototypes featuring an additional GEM foil, as well as an resistive prototype, are installed at COMPASS and preliminary results from those detectors presented very good performance. We present here the project and report on its status, in particular the performance of large size prototypes with an additional GEM foil.
△ Less
Submitted 25 January, 2012; v1 submitted 14 November, 2011;
originally announced November 2011.
-
Development of a GEM-TPC prototype
Authors:
Heinz Angerer,
Reinhard Beck,
Martin Berger,
Felix Boehmer,
K. -T. Brinkmann,
Paul Buehler,
Michael Carnegie,
Sverre Dorheim,
Laura Fabbietti,
Chr. Funke,
F. Cusanno,
Joerg Hehner,
Andreas Heinz,
Markus Henske,
Christian Hoeppner,
David Kaiser,
Bernhard Ketzer,
Igor Konorov,
Jochen Kunkel,
Michael Lang,
Johann Marton,
Sebastian Neubert,
Stephan Paul,
Alexander Schmah,
Christian Schmidt
, et al. (15 additional authors not shown)
Abstract:
The use of GEM foils for the amplification stage of a TPC instead of a con- ventional MWPC allows one to bypass the necessity of gating, as the backdrift is suppressed thanks to the asymmetric field configuration. This way, a novel continuously running TPC, which represents one option for the PANDA central tracker, can be realized. A medium sized prototype with a diameter of 300 mm and a length…
▽ More
The use of GEM foils for the amplification stage of a TPC instead of a con- ventional MWPC allows one to bypass the necessity of gating, as the backdrift is suppressed thanks to the asymmetric field configuration. This way, a novel continuously running TPC, which represents one option for the PANDA central tracker, can be realized. A medium sized prototype with a diameter of 300 mm and a length of 600 mm will be tested inside the FOPI spectrometer at GSI using a carbon or lithium beam at intermediate energies (E = 1-3AGeV). This detector test under realistic experimental conditions should allow us to verify the spatial resolution for single tracks and the reconstruction capability for displaced vertexes. A series of physics measurement implying pion beams is scheduled with the FOPI spectrometer together with the GEM-TPC as well.
△ Less
Submitted 4 November, 2009;
originally announced November 2009.
-
New pixelized Micromegas detector for the COMPASS experiment
Authors:
Damien Neyret,
Marc Anfreville,
Yann Bedfer,
Etienne Burtin,
Nicole d'Hose,
Arnaud Giganon,
Bernhard Ketzer,
Igor Konorov,
Fabienne Kunne,
Alain Magnon,
Claude Marchand,
Bernard Paul,
Stéphane Platchkov,
Maxence Vandenbroucke
Abstract:
New Micromegas (Micro-mesh gaseous detectors) are being developed in view of the future physics projects planned by the COMPASS collaboration at CERN. Several major upgrades compared to present detectors are being studied: detectors standing five times higher luminosity with hadron beams, detection of beam particles (flux up to a few hundred of kHz/mm^2, 10 times larger than for the present dete…
▽ More
New Micromegas (Micro-mesh gaseous detectors) are being developed in view of the future physics projects planned by the COMPASS collaboration at CERN. Several major upgrades compared to present detectors are being studied: detectors standing five times higher luminosity with hadron beams, detection of beam particles (flux up to a few hundred of kHz/mm^2, 10 times larger than for the present detectors) with pixelized read-out in the central part, light and integrated electronics, and improved robustness. Studies were done with the present detectors moved in the beam, and two first pixelized prototypes are being tested with muon and hadron beams in real conditions at COMPASS. We present here this new project and report on two series of tests, with old detectors moved into the beam and with pixelized prototypes operated in real data taking condition with both muon and hadron beams.
△ Less
Submitted 19 October, 2009; v1 submitted 29 September, 2009;
originally announced September 2009.