Skip to main content

Showing 1–35 of 35 results for author: Van Stenis, M

Searching in archive physics. Search in all archives.
.
  1. arXiv:2406.08712  [pdf, other

    physics.ins-det hep-ex

    A Novel Diamond-like Carbon based photocathode for PICOSEC Micromegas detectors

    Authors: X. Wang, R. Aleksan, Y. Angelis, J. Bortfeldt, F. Brunbauer, M. Brunoldi, E. Chatzianagnostou, J. Datta, K. Degmelt, G. Fanourakis, D. Fiorina, K. J. Floethner, M. Gallinaro, F. Garcia, I. Giomataris, K. Gnanvo, F. J. Iguaz, D. Janssens, A. Kallitsopoulou, M. Kovacic, B. Kross, P. Legou, M. Lisowska, J. Liu, I. Maniatis , et al. (26 additional authors not shown)

    Abstract: The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes equipped with cesium iodide (CsI) photocathodes have shown promising time resolutions as precise as 24 picoseconds (ps) for Minimum Ionizing Particles. However, due to the high hygroscopicity and susceptibility to ion bomb… ▽ More

    Submitted 25 June, 2024; v1 submitted 12 June, 2024; originally announced June 2024.

  2. arXiv:2406.05836  [pdf, other

    physics.ins-det

    Spatial resolution improvements with finer-pitch GEMs

    Authors: K. J. Flöthner, L. Scharenberg, A. Brask, F. Brunbauer, F. Garcia, D. Janssens, B. Ketzer, M. Lisowska, H. Muller, E. Oliveri, G. Orlandini, D. Pfeiffer, L. Ropelewski, J. Samarati, M. Van Stenis, R. Veenhof

    Abstract: Gas Electron Multipliers (GEMs) are used in many particle physics experiments, employing their 'standard' configuration with amplification holes of 140 um pitch in a hexagonal pattern. However, the collection of the charge cloud from the primary ionisation electrons from the drift region of the detector into the GEM holes affects the position information from the initial interacting particle. In t… ▽ More

    Submitted 9 June, 2024; originally announced June 2024.

  3. arXiv:2406.05657  [pdf, other

    physics.ins-det

    Single channel PICOSEC Micromegas detector with improved time resolution

    Authors: A. Utrobicic, R. Aleksan, Y. Angelis, J. Bortfeldt, F. Brunbauer, M. Brunoldi, E. Chatzianagnostou, J. Datta, K. Dehmelt, G. Fanourakis, D. Fiorina, K. J. Floethner, M. Gallinaro, F. Garcia, I. Giomataris, K. Gnanvo, F. J. Iguaz, D. Janssens, A. Kallitsopoulou, M. Kovacic, B. Kross, P. Legou, M. Lisowska, J. Liu, M. Lupberger , et al. (25 additional authors not shown)

    Abstract: This paper presents design guidelines and experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and electrical connectivity for high voltage (HV) and signals, focusing on improving stability, reducing noise, and ensuring signal integrity to optimize timing perfo… ▽ More

    Submitted 9 June, 2024; originally announced June 2024.

  4. arXiv:2402.03899  [pdf, other

    physics.ins-det

    Characterisation of resistive MPGDs with 2D readout

    Authors: L. Scharenberg, F. Brunbauer, H. Danielson, Z. Fang, K. J. Flöthner, F. Garcia, D. Janssens, M. Lisowska, J. Liu, Y. Lyu, B. Mehl, H. Muller, R. de Oliveira, E. Oliveri, G. Orlandini, D. Pfeiffer, O. Pizzirusso, L. Ropelewski, J. Samarati, M. Shao, A. Teixeira, M. Van Stenis, R. Veenhof, Z. Zhang, Y. Zhou

    Abstract: Micro-Pattern Gaseous Detectors (MPGDs) with resistive anode planes provide intrinsic discharge robustness while maintaining good spatial and time resolutions. Typically read out with 1D strips or pad structures, here the characterisation results of resistive anode plane MPGDs with 2D strip readout are presented. A uRWELL prototype is investigated in view of its use as a reference tracking detecto… ▽ More

    Submitted 6 February, 2024; originally announced February 2024.

  5. arXiv:2305.10515  [pdf, other

    hep-ex physics.ins-det

    The LHCb upgrade I

    Authors: LHCb collaboration, R. Aaij, A. S. W. Abdelmotteleb, C. Abellan Beteta, F. Abudinén, C. Achard, T. Ackernley, B. Adeva, M. Adinolfi, P. Adlarson, H. Afsharnia, C. Agapopoulou, C. A. Aidala, Z. Ajaltouni, S. Akar, K. Akiba, P. Albicocco, J. Albrecht, F. Alessio, M. Alexander, A. Alfonso Albero, Z. Aliouche, P. Alvarez Cartelle, R. Amalric, S. Amato , et al. (1298 additional authors not shown)

    Abstract: The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their select… ▽ More

    Submitted 17 May, 2023; originally announced May 2023.

    Comments: All figures and tables, along with any supplementary material and additional information, are available at http://lhcbproject.web.cern.ch/lhcbproject/Publications/LHCbProjectPublic/LHCb-DP-2022-002.html (LHCb public pages)

    Report number: LHCb-DP-2022-002

  6. A large area 100 channel Picosec Micromegas detector with sub 20 ps time resolution

    Authors: Antonija Utrobicic, Yannis Angelis, Stephan Aune, Jonathan Bortfeldt, Florian Brunbauer, Evridiki Chatzianagnostou, Klaus Dehmelt, Daniel Desforge, George Fanourakis, Karl Jonathan Floethner, Michele Gallinaro, Francisco Garcia, Prakhar Garg, Ioannis Giomataris, Kondo Gnanvo, Thomas Gustavsson, Francisco Jose Iguaz, Djunes Janssens, Alexandra Kallitsopoulou, Marinko Kovacic, Philippe Legou, Marta Lisowska, Jianbei Liu, Michael Lupberger, Simona Malace , et al. (20 additional authors not shown)

    Abstract: The PICOSEC Micromegas precise timing detector is based on a Cherenkov radiator coupled to a semi-transparent photocathode and a Micromegas amplification structure. The first proof of concept single-channel small area prototype was able to achieve time resolution below 25 ps. One of the crucial aspects in the development of the precise timing gaseous detectors applicable in high-energy physics exp… ▽ More

    Submitted 31 March, 2023; originally announced April 2023.

  7. Towards robust PICOSEC Micromegas precise timing detectors

    Authors: Marta Lisowska, Yannis Angelis, Stephan Aune, Jonathan Bortfeldt, Florian Brunbauer, Evridiki Chatzianagnostou, Klaus Dehmelt, Daniel Desforge, George Fanourakis, Karl Jonathan Floethner, Michele Gallinaro, Francisco Garcia, Prakhar Garg, Ioannis Giomataris, Kondo Gnanvo, Thomas Gustavsson, Francisco Jose Iguaz, Djunes Janssens, Alexandra Kallitsopoulou, Marinko Kovacic, Philippe Legou, Jianbei Liu, Michael Lupberger, Simona Malace, Ioannis Maniatis , et al. (21 additional authors not shown)

    Abstract: The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector consisting of a Cherenkov radiator combined with a photocathode and a MM amplifying structure. A 100-channel non-resistive PICOSEC MM prototype with 10x10 cm^2 active area equipped with a Cesium Iodide (CsI) photocathode demonstrated a time resolution below 18 ps. The objective of this work is to improve the PICOSEC MM detec… ▽ More

    Submitted 31 March, 2023; originally announced March 2023.

  8. The novel XYU-GEM to resolve ambiguities

    Authors: K. J. Flöthner, F. Brunbauer, S. Ferry, F. Garcia, D. Janssens, B. Ketzer, M. Lisowska, H. Muller, R. de Oliveira, E. Oliveri, G. Orlandini, D. Pfeiffer, L. Ropelewski, J. Samarati, F. Sauli, L. Scharenberg, M. van Stenis, A. Utrobicic, R. Veenhof

    Abstract: Removing ambiguities within a single stage becomes crucial when one can not use multiple detectors behind each other to resolve them which naturally is the case for neutral radiation. An example would be RICH detectors. Commonly pixilated readout is choosen for this purpose. However, this causes a remarkable increase in quantity of channels and does not scale up well. Therefore, the XYU-GEM was pr… ▽ More

    Submitted 31 March, 2023; originally announced March 2023.

  9. Performance of the new RD51 VMM3a/SRS beam telescope---studying MPGDs simultaneously in energy, space and time at high rates

    Authors: L. Scharenberg, J. Bortfeldt, F. Brunbauer, K. Desch, K. Flöthner, F. Garcia, D. Janssens, M. Lisowska, H. Muller, E. Oliveri, G. Orlandini, D. Pfeiffer, L. Ropelewski, J. Samarati, D. Sorvisto, M. van Stenis, R. Veenhof

    Abstract: The RD51 collaboration maintains a common infrastructure at CERN for its R & D activities, including two beam telescopes for test beam campaigns. Recently, one of the beam telescopes has been equipped and commissioned with new multi-channel and charge-sensitive front-end electronics based on the ATLAS/BNL VMM3a front-end ASIC and the RD51 Scalable Readout System (SRS). This allows to read out the… ▽ More

    Submitted 16 February, 2023; originally announced February 2023.

  10. Precise timing and recent advancements with segmented anode PICOSEC Micromegas prototypes

    Authors: I. Manthos, S. Aune, J. Bortfeldt, F. Brunbauer, C. David, D. Desforge, G. Fanourakis, M. Gallinaro, F. García, I. Giomataris, T. Gustavsson, F. J. Iguaz, A. Kallitsopoulou, M. Kebbiri, K. Kordas, C. Lampoudis, P. Legou, M. Lisowska, J. Liu, M. Lupberger, O. Maillard, I. Maniatis, H. Müller, E. Oliveri, T. Papaevangelou , et al. (19 additional authors not shown)

    Abstract: Timing information in current and future accelerator facilities is important for resolving objects (particle tracks, showers, etc.) in extreme large particles multiplicities on the detection systems. The PICOSEC Micromegas detector has demonstrated the ability to time 150\,GeV muons with a sub-25\,ps precision. Driven by detailed simulation studies and a phenomenological model which describes stoc… ▽ More

    Submitted 22 November, 2022; originally announced November 2022.

    Comments: 5 pages, 3 figures, 12th International Conference on Position Sensitive Detectors

    Journal ref: JINST 17 C10009 (2022)

  11. Demonstration of Gd-GEM detector design for neutron macromolecular crystallography applications

    Authors: D. Pfeiffer, F. Brunbauer, R. Hall-Wilton, M. Lupberger, M. Marko, H. Muller, E. Oksanen, E. Oliveri, L. Ropelewski, A. Rusu, J. Samarati, L. Scharenberg, M. van Stenis, P. Thuiner, R. Veenhof

    Abstract: The European Spallation Source (ESS) in Lund, Sweden will become the world's most powerful thermal neutron source. The Macromolecular Diffractometer (NMX) at the ESS requires three 51.2 x 51.2~cm$^{2}$ detectors with reasonable detection efficiency, sub-mm spatial resolution, a narrow point spread function (PSF) and good time resolution. This work presents measurements with the improved version of… ▽ More

    Submitted 16 March, 2023; v1 submitted 8 November, 2022; originally announced November 2022.

  12. arXiv:2203.06562  [pdf, other

    physics.ins-det hep-ex nucl-ex

    Snowmass 2021 White Paper Instrumentation Frontier 05 -- White Paper 1: MPGDs: Recent advances and current R&D

    Authors: K. Dehmelt, M. Della Pietra, H. Muller, S. E. Tzamarias, A. White, S. White, Z. Zhang, M. Alviggi, I. Angelis, S. Aune, J. Bortfeldt, M. Bregant, F. Brunbauer, M. T. Camerlingo, V. Canale, V. D'Amico, D. Desforge, C. Di Donato, R. Di Nardo, G. Fanourakis, K. J. Floethner, M. Gallinaro, F. Garcia, I. Giomataris, K. Gnanvo , et al. (45 additional authors not shown)

    Abstract: This paper will review the origins, development, and examples of new versions of Micro-Pattern Gas Detectors. The goal for MPGD development was the creation of detectors that could cost-effectively cover large areas while offering excellent position and timing resolution, and the ability to operate at high incident particle rates. The early MPGD developments culminated in the formation of the RD51… ▽ More

    Submitted 19 March, 2022; v1 submitted 12 March, 2022; originally announced March 2022.

    Comments: Contribution to Snowmass 2021

  13. arXiv:2203.05914  [pdf, other

    physics.ins-det astro-ph.CO hep-ex hep-ph

    Recoil imaging for directional detection of dark matter, neutrinos, and physics beyond the Standard Model

    Authors: C. A. J. O'Hare, D. Loomba, K. Altenmüller, H. Álvarez-Pol, F. D. Amaro, H. M. Araújo, D. Aristizabal Sierra, J. Asaadi, D. Attié, S. Aune, C. Awe, Y. Ayyad, E. Baracchini, P. Barbeau, J. B. R. Battat, N. F. Bell, B. Biasuzzi, L. J. Bignell, C. Boehm, I. Bolognino, F. M. Brunbauer, M. Caamaño, C. Cabo, D. Caratelli, J. M. Carmona , et al. (142 additional authors not shown)

    Abstract: Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detect… ▽ More

    Submitted 17 July, 2022; v1 submitted 11 March, 2022; originally announced March 2022.

    Comments: 77 pages, 20 figures. Submitted to the Proceedings of the US Community Study on the Future of Particle Physics (Snowmass 2021)

  14. arXiv:2112.12763  [pdf, other

    physics.ins-det hep-ex

    Microchannel cooling for the LHCb VELO Upgrade I

    Authors: Oscar Augusto De Aguiar Francisco, Wiktor Byczynski, Kazu Akiba, Claudia Bertella, Alexander Bitadze, Matthew Brock, Bartosz Bulat, Guillaume Button, Jan Buytaert, Stefano De Capua, Riccardo Callegari, Christine Castellana, Andrea Catinaccio, Catherine Charrier, Collette Charvet, Victor Coco, Paula Collins, Jordan Degrange, Raphael Dumps, Diego Alvarez Feito, Julian Freestone, Mariusz Jedrychowski, Vinicius Franco Lima, Abraham Gallas, Wouter Hulsbergen , et al. (35 additional authors not shown)

    Abstract: The LHCb VELO Upgrade I, currently being installed for the 2022 start of LHC Run 3, uses silicon microchannel coolers with internally circulating bi-phase \cotwo for thermal control of hybrid pixel modules operating in vacuum. This is the largest scale application of this technology to date. Production of the microchannel coolers was completed in July 2019 and the assembly into cooling structures… ▽ More

    Submitted 23 December, 2021; originally announced December 2021.

    Comments: 31 pages, 27 figures

    Report number: LHCb-PUB-2021-010

  15. Rate-capability of the VMM3a Front End in the RD51 Scalable Readout System

    Authors: D. Pfeiffer, L. Scharenberg, P. Schwäbig, S. Alcock, F. Brunbauer, M. J. Christensen, K. Desch, K. Flöthner, F. Garcia, R. Hall-Wilton, M. Hracek, G. Iakovidis, D. Janssens, J. Kaminski, M. Lupberger, H. Muller, E. Oliveri, L. Ropelewski, A. Rusu, J. Samarati, M. van Stenis, A. Utrobicic, R. Veenhof

    Abstract: The VMM3a is an Application Specific Integrated Circuit (ASIC), specifically developed for the readout of gaseous detectors. Originally developed within the ATLAS New Small Wheel (NSW) upgrade, it has been successfully integrated into the Scalable Readout System (SRS) of the RD51 collaboration. This allows, to use the VMM3a also in small laboratory set-ups and mid-scale experiments, which make use… ▽ More

    Submitted 2 February, 2022; v1 submitted 21 September, 2021; originally announced September 2021.

  16. arXiv:2012.00545  [pdf, other

    physics.ins-det hep-ex

    Timing performance of a multi-pad PICOSEC-Micromegas detector prototype

    Authors: S. Aune, J. Bortfeldt, F. Brunbauer, C. David, D. Desforge, G. Fanourakis, M. Gallinaro, F. García, I. Giomataris, T. Gustavsson, F. J. Iguaz, M. Kebbiri, K. Kordas, C. Lampoudis, P. Legou, M. Lisowska, J. Liu, M. Lupberger, O. Maillard, I. Manthos, H. Müller, E. Oliveri, T. Papaevangelou, K. Paraschou, M. Pomorski , et al. (17 additional authors not shown)

    Abstract: The multi-pad PICOSEC-Micromegas is an improved detector prototype with a segmented anode, consisting of 19 hexagonal pads. Detailed studies are performed with data collected in a muon beam over four representative pads. We demonstrate that such a device, scalable to a larger area, provides excellent time resolution and detection efficiency. As expected from earlier single-cell device studies, we… ▽ More

    Submitted 28 January, 2021; v1 submitted 1 December, 2020; originally announced December 2020.

    Comments: 29 pages, 20 figures

  17. Optical Readout Studies of the Thick-COBRA Gaseous Detector

    Authors: F. Garcia, F. M. Brunbauer, M. Lisowska, H. Müller, E. Oliveri, D. Pfeiffer, L. Ropelewski, J. Samarati, F. Sauli, L. Scharenberg, A. L. M. Silva, M. van Stenis, R. Veenhof, J. F. C. A. Veloso

    Abstract: The performance of a Thick-COBRA (THCOBRA) gaseous detector is studied using an optical readout technique. The operation principle of this device is described, highlighting its operation in a gas mixture of Ar/CF4 (80/20%) for visible scintillation light emission. The contributions to the total gain from the holes and the anode strips as a function of the applied bias voltage were visualized. The… ▽ More

    Submitted 24 July, 2020; originally announced July 2020.

    Comments: 12 pages, 11 figures

    ACM Class: J.2

  18. Timing Performance of a Micro-Channel-Plate Photomultiplier Tube

    Authors: Jonathan Bortfeldt, Florian Brunbauer, Claude David, Daniel Desforge, Georgios Fanourakis, Michele Gallinaro, Francisco Garcia, Ioannis Giomataris, Thomas Gustavsson, Claude Guyot, Francisco Jose Iguaz, Mariam Kebbiri, Kostas Kordas, Philippe Legou, Jianbei Liu, Michael Lupberger, Ioannis Manthos, Hans Müller, Vasileios Niaouris, Eraldo Oliveri, Thomas Papaevangelou, Konstantinos Paraschou, Michal Pomorski, Filippo Resnati, Leszek Ropelewski , et al. (14 additional authors not shown)

    Abstract: The spatial dependence of the timing performance of the R3809U-50 Micro-Channel-Plate PMT (MCP-PMT) by Hamamatsu was studied in high energy muon beams. Particle position information is provided by a GEM tracker telescope, while timing is measured relative to a second MCP-PMT, identical in construction. In the inner part of the circular active area (radius r$<$5.5\,mm) the time resolution of the tw… ▽ More

    Submitted 14 February, 2020; v1 submitted 27 September, 2019; originally announced September 2019.

    Comments: 6 pages, 6 figures, preprint submitted to Nuclear Instruments and Methods A

  19. arXiv:1901.10779  [pdf, other

    physics.ins-det

    Modeling the Timing Characteristics of the PICOSEC Micromegas Detector

    Authors: J. Bortfeldt, F. Brunbauer, C. David, D. Desforge, G. Fanourakis, M. Gallinaro, F. García, I. Giomataris, T. Gustavsson, F. J. Iguaz, M. Kebbiri, K. Kordas, C. Lampoudis, P. Legou, M. Lisowska, J. Liu, M. Lupberger, O. Maillard, I. Manthos, H. Müller, V. Niaouris, E. Oliveri, T . Papaevangelou, K. Paraschou, M. Pomorski , et al. (16 additional authors not shown)

    Abstract: The PICOSEC Micromegas detector can time the arrival of Minimum Ionizing Particles with a sub-25 ps precision. A very good timing resolution in detecting single photons is also demonstrated in laser beams. The PICOSEC timing resolution is determined mainly by the drift field. The arrival time of the signal and the timing resolution vary with the size of the pulse amplitude. Detailed simulations ba… ▽ More

    Submitted 2 December, 2020; v1 submitted 30 January, 2019; originally announced January 2019.

    Comments: Corresponding author S. E. Tzamarias, 47 pages, 19 figures, 2 appendices, 8 tables

  20. arXiv:1901.03355  [pdf, other

    physics.ins-det

    Precise Charged Particle Timing with the PICOSEC Detector

    Authors: J. Bortfeldt, F. Brunbauer, C. David, D. Desforge, G. Fanourakis, J. Franchi, M. Gallinaro, F. García, I. Giomataris, T. Gustavsson, C. Guyot, F. J. Iguaz, M. Kebbiri, K. Kordas, P. Legou, J. Liu, M. Lupberger, O. Maillard, I. Manthos, H. Müller, V. Niaouris, E. Oliveri, T. Papaevangelou, K. Paraschou, M. Pomorski , et al. (16 additional authors not shown)

    Abstract: The experimental requirements in near future accelerators (e.g. High Luminosity-LHC) has stimulated intense interest in development of detectors with high precision timing capabilities. With this as a goal, a new detection concept called PICOSEC, which is based to a "two-stage" MicroMegas detector coupled to a Cherenkov radiator equipped with a photocathode has been developed. Results obtained wit… ▽ More

    Submitted 10 January, 2019; originally announced January 2019.

    Comments: 7 pages, 7 figures, 10th Jubilee Conference of the Balkan Physical Union

  21. Charged particle timing at sub-25 picosecond precision: the PICOSEC detection concept

    Authors: F. J. Iguaz, J. Bortfeldt, F. Brunbauer, C. David, D. Desforge, G. Fanourakis, J. Franchi, M. Gallinaro, F. García, I. Giomataris, D. González-Díaz, T. Gustavsson, C. Guyot, M. Kebbiri, P. Legou, J. Liu, M. Lupberger, O. Maillard, I. Manthos, H. Müller, V. Niaouris, E. Oliveri, T. Papaevangelou, K. Paraschou, M. Pomorski , et al. (16 additional authors not shown)

    Abstract: The PICOSEC detection concept consists in a "two-stage" Micromegas detector coupled to a Cherenkov radiator and equipped with a photocathode. A proof of concept has already been tested: a single-photoelectron response of 76 ps has been measured with a femtosecond UV laser at CEA/IRAMIS, while a time resolution of 24 ps with a mean yield of 10.4 photoelectrons has been measured for 150 GeV muons at… ▽ More

    Submitted 4 August, 2018; v1 submitted 12 June, 2018; originally announced June 2018.

    Comments: 4 pages, 7 figures, proceedings of the 14th Pisa Meeting on Advanced Detectors (PM2018), submitted to Nucl. Instr. Meth. A; version 2: 2 figures modified, minor changes in the text

  22. PICOSEC: Charged particle timing at sub-25 picosecond precision with a Micromegas based detector

    Authors: J. Bortfeldt, F. Brunbauer, C. David, D. Desforge, G. Fanourakis, J. Franchi, M. Gallinaro, I. Giomataris, D. González-Díaz, T. Gustavsson, C. Guyot, F. J. Iguaz, M. Kebbiri, P. Legou, J. Liu, M. Lupberger, O. Maillard, I. Manthos, H. Müller, V. Niaouris, E. Oliveri, T. Papaevangelou, K. Paraschou, M. Pomorski, B. Qi , et al. (15 additional authors not shown)

    Abstract: The prospect of pileup induced backgrounds at the High Luminosity LHC (HL-LHC) has stimulated intense interest in develo** technologies for charged particle detection with accurate timing at high rates. The required accuracy follows directly from the nominal interaction distribution within a bunch crossing ($σ_z\sim5$ cm, $σ_t\sim170$ ps). A time resolution of the order of 20-30 ps would lead to… ▽ More

    Submitted 14 March, 2018; v1 submitted 14 December, 2017; originally announced December 2017.

    Comments: 27 pages, 15 figures, preprint submitted to Nuclear Instruments and Methods A, v2: typos fixed and an improved discussion, v3: revised version

  23. arXiv:1512.08529  [pdf, ps, other

    physics.ins-det

    A novel application of Fiber Bragg Grating (FBG) sensors in MPGD

    Authors: D. Abbaneo, M. Abbas, M. Abbrescia, A. A. Abdelalim, M. Abi Akl, O. Aboamer, D. Acosta, A. Ahmad, W. Ahmed, W. Ahmed, A. Aleksandrov, R. Aly, P. Altieri, C. Asawatangtrakuldee, P. Aspell, Y. Assran, I. Awan, S. Bally, Y. Ban, S. Banerjee, V. Barashko, P. Barria, G. Bencze, N. Beni, L. Benussi , et al. (133 additional authors not shown)

    Abstract: We present a novel application of Fiber Bragg Grating (FBG) sensors in the construction and characterisation of Micro Pattern Gaseous Detector (MPGD), with particular attention to the realisation of the largest triple (Gas electron Multiplier) GEM chambers so far operated, the GE1/1 chambers of the CMS experiment at LHC. The GE1/1 CMS project consists of 144 GEM chambers of about 0.5 m2 active are… ▽ More

    Submitted 28 December, 2015; originally announced December 2015.

    Comments: 4 pages, 4 figures, presented by Luigi Benussi at MPGD 2015 (Trieste, Italy). arXiv admin note: text overlap with arXiv:1512.08481

    Report number: INFN-15-10/LNF

  24. Fiber Bragg Grating (FBG) sensors as flatness and mechanical stretching sensors

    Authors: D. Abbaneo, M. Abbas, M. Abbrescia, A. A. Abdelalim, M. Abi Akl, O. Aboamer, D. Acosta, A. Ahmad, W. Ahmed, W. Ahmed, A. Aleksandrov, R. Aly, P. Altieri, C. Asawatangtrakuldee, P. Aspell, Y. Assran, I. Awan, S. Bally, Y. Ban, S. Banerjee, V. Barashko, P. Barria, G. Bencze, N. Beni, L. Benussi , et al. (133 additional authors not shown)

    Abstract: A novel approach which uses Fibre Bragg Grating (FBG) sensors has been utilised to assess and monitor the flatness of Gaseous Electron Multipliers (GEM) foils. The setup layout and preliminary results are presented.

    Submitted 28 December, 2015; originally announced December 2015.

    Comments: Two pages, one figure. Presented by Luigi Benussi (corresponding author) to Elba 2015 conference

    Report number: Frascati Preprint INFN-15-09/LNF

  25. arXiv:1512.05409  [pdf, other

    physics.ins-det hep-ex

    Charge Transfer Properties Through Graphene for Applications in Gaseous Detectors

    Authors: S. Franchino, D. Gonzalez-Diaz, R. Hall-Wilton, R. B. Jackman, H. Muller, T. T. Nguyen, R. de Oliveira, E. Oliveri, D. Pfeiffer, F. Resnati, L. Ropelewski, J. Smith, M. van Stenis, C. Streli, P. Thuiner, R. Veenhof

    Abstract: Graphene is a single layer of carbon atoms arranged in a honeycomb lattice with remarkable mechanical and electrical properties. Regarded as the thinnest and narrowest conductive mesh, it has drastically different transmission behaviours when bombarded with electrons and ions in vacuum. This property, if confirmed in gas, may be a definitive solution for the ion back-flow problem in gaseous detect… ▽ More

    Submitted 16 December, 2015; originally announced December 2015.

    Comments: 4pages, 3figures, 13th Pisa Meeting on Advanced Detectors

  26. arXiv:1512.04968  [pdf, ps, other

    physics.ins-det hep-ex

    Effects of High Charge Densities in Multi-GEM Detectors

    Authors: S. Franchino, D. Gonzalez Diaz, R. Hall-Wilton, H. Muller, E. Oliveri, D. Pfeiffer, F. Resnati, L. Ropelewski, M. Van Stenis, C. Streli, P. Thuiner, R. Veenhof

    Abstract: A comprehensive study, supported by systematic measurements and numerical computations, of the intrinsic limits of multi-GEM detectors when exposed to very high particle fluxes or operated at very large gains is presented. The observed variations of the gain, of the ion back-flow, and of the pulse height spectra are explained in terms of the effects of the spatial distribution of positive ions and… ▽ More

    Submitted 15 December, 2015; originally announced December 2015.

    Comments: 5 pages, 6 figures, 2015 IEEE Nuclear Science Symposium

  27. arXiv:1503.06596  [pdf, other

    physics.ins-det hep-ex

    Charge Transfer Properties Through Graphene Layers in Gas Detectors

    Authors: P. Thuiner, R. Hall-Wilton, R. B. Jackman, H. Müller, T. T. Nguyen, E. Oliveri, D. Pfeiffer, F. Resnati, L. Ropelewski, J. A. Smith, M. van Stenis, R. Veenhof

    Abstract: Graphene is a single layer of carbon atoms arranged in a honeycomb lattice with remarkable mechanical, electrical and optical properties. For the first time graphene layers suspended on copper meshes were installed into a gas detector equipped with a gaseous electron multiplier. Measurements of low energy electron and ion transfer through graphene were conducted. In this paper we describe the samp… ▽ More

    Submitted 23 March, 2015; originally announced March 2015.

    Comments: 2014 IEEE Nuclear Science Symposium and Medical Imaging Conference with the 21st Symposium on Room-Temperature Semiconductor X-Ray and Gamma-Ray Detectors, 4 pages, 8 figures

  28. arXiv:1412.0228  [pdf, other

    physics.ins-det

    Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System

    Authors: D. Abbaneo, M. Abbas, M. Abbrescia, A. A. Abdelalim, M. Abi Akl, W. Ahmed, W. Ahmed, P. Altieri, R. Aly, C. Asawatangtrakuldee, A. Ashfaq, P. Aspell, Y. Assran, I. Awan, S. Bally, Y. Ban, S. Banerjee, P. Barria, L. Benussi, V. Bhopatkar, S. Bianco, J. Bos, O. Bouhali, S. Braibant, S. Buontempo , et al. (113 additional authors not shown)

    Abstract: Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the $1.5 < \midη\mid < 2.2$ region of the muon endcap mainly to control muon level-1 trigger rates after the second long LHC shutdown. A GE1/1 triple-GEM detector is read out by 3,072 radial strips wi… ▽ More

    Submitted 8 December, 2014; v1 submitted 30 November, 2014; originally announced December 2014.

    Comments: 8 pages, 32 figures, submitted to Proc. 2014 IEEE Nucl. Sci. Symposium, Seattle, WA, reference added

  29. arXiv:1012.3675  [pdf, ps, other

    physics.ins-det hep-ex

    Characterization of GEM Detectors for Application in the CMS Muon Detection System

    Authors: D. Abbaneo, S. Bally, H. Postema, A. Conde Garcia, J. P. Chatelain, G. Faber, L. Ropelewski, E. David, S. Duarte Pinto, G. Croci, M. Alfonsi, M. van Stenis, A. Sharma, L. Benussi, S. Bianco, S. Colafranceschi, D. Piccolo, G. Saviano, N. Turini, E. Oliveri, G. Magazzu', A. Marinov, M. Tytgat, N. Zaganidis, M. Hohlmann , et al. (4 additional authors not shown)

    Abstract: The muon detection system of the Compact Muon Solenoid experiment at the CERN Large Hadron Collider is based on different technologies for muon tracking and triggering. In particular, the muon system in the endcap disks of the detector consists of Resistive Plate Chambers for triggering and Cathode Strip Chambers for tracking. At present, the endcap muon system is only partially instrumented with… ▽ More

    Submitted 16 December, 2010; originally announced December 2010.

    Comments: 7 pages, 19 figures, submitted for publication in conference record of the 2010 IEEE Nuclear Science Symposium, Knoxville, TN

    Report number: RD51-Note-2010-005

  30. arXiv:1012.1524  [pdf, ps, other

    physics.ins-det hep-ex

    Construction of the first full-size GEM-based prototype for the CMS high-$η$ muon system

    Authors: D. Abbaneo, S. Bally, H. Postema, A. Conde Garcia, J. P. Chatelain, G. Faber, L. Ropelewski, S. Duarte Pinto, G. Croci, M. Alfonsi, M. Van Stenis, A. Sharma, L. Benussi, S. Bianco, S. Colafranceschi, F. Fabbri, L. Passamonti, D. Piccolo, D. Pierluigi, G. Raffone, A. Russo, G. Saviano, A. Marinov, M. Tytgat, N. Zaganidis , et al. (10 additional authors not shown)

    Abstract: In view of a possible extension of the forward CMS muon detector system and future LHC luminosity upgrades, Micro-Pattern Gas Detectors (MPGDs) are an appealing technology. They can simultaneously provide precision tracking and fast trigger information, as well as sufficiently fine segmentation to cope with high particle rates in the high-eta region at LHC and its future upgrades. We report on the… ▽ More

    Submitted 9 December, 2010; v1 submitted 7 December, 2010; originally announced December 2010.

    Comments: 5 pages, 11 figures, presented by S.Colafranceschi at IEEE 2010 (Knoxville, USA)

    Report number: RD51-NOTE-2010-008, Frascati Preprint LNF - 10 / 24(P)

  31. First results of spherical GEMs

    Authors: Serge Duarte Pinto, Matteo Alfonsi, Ian Brock, Gabriele Croci, Eric David, Rui de Oliveira, Leszek Ropelewski, Miranda van Stenis, Hans Taureg, Marco Villa

    Abstract: We developed a method to make GEM foils with a spherical geometry. Tests of this procedure and with the resulting spherical GEMs are presented. Together with a spherical drift electrode, a spherical conversion gap can be formed. This eliminates the parallax error for detection of x-rays, neutrons or UV photons when a gaseous converter is used. This parallax error limits the spatial resolution at w… ▽ More

    Submitted 24 November, 2010; originally announced November 2010.

    Comments: Submitted to the IEEE Nuclear Science Symposium 2010 Conference Record. This paper won the third place Student Paper Award at the Nuclear Science Symposium

    Journal ref: IEEE Nuclear Science Symposium 2010 Conference Record

  32. Progress on large area GEMs (VCI 2010)

    Authors: Marco Villa, Serge Duarte Pinto, Matteo Alfonsi, Ian Brock, Gabriele Croci, Eric David, Rui de Oliveira, Leszek Ropelewski, Hans Taureg, Miranda van Stenis

    Abstract: The Gas Electron Multiplier (GEM) manufacturing technique has recently evolved to allow the production of large area GEMs. A novel approach based on single mask photolithography eliminates the mask alignment issue, which limits the dimensions in the traditional double mask process. Moreover, a splicing technique overcomes the limited width of the raw material. Stretching and handling issues in lar… ▽ More

    Submitted 7 July, 2010; originally announced July 2010.

    Comments: 4 pages, 8 figures, preprint submitted to Nuclear Instruments and Methods A

    Journal ref: Nucl. Instrum. Meth. A628: 182-186,2011; Nucl.Instrum.Meth.A628:182-186,2011

  33. Spherical GEMs for parallax-free detectors

    Authors: Serge Duarte Pinto, Matteo Alfonsi, Ian Brock, Gabriele Croci, Eric David, Rui de Oliveira, Leszek Ropelewski, Miranda van Stenis, Hans Taureg, Marco Villa

    Abstract: We developed a method to make GEM foils with a spherical geometry. Tests of this procedure and with the resulting spherical \textsc{gem}s are presented. Together with a spherical drift electrode, a spherical conversion gap can be formed. This would eliminate the parallax error for detection of x-rays, neutrons or UV photons when a gaseous converter is used. This parallax error limits the spatial… ▽ More

    Submitted 17 November, 2009; originally announced November 2009.

    Comments: Contribution to the 2009 IEEE Nuclear Science Symposium, Orlando, Florida

    Report number: N11-1, pages 225 - 230

    Journal ref: Nuclear Science Symposium Conference Record (NSS/MIC), 2009 IEEE

  34. Progress on large area GEMs

    Authors: Serge Duarte Pinto, Marco Villa, Matteo Alfonsi, Ian Brock, Gabriele Croci, Eric David, Rui de Oliveira, Leszek Ropelewski, Miranda van Stenis

    Abstract: In 2008, a triple GEM detector prototype with an area of ~2000 cm2 has been constructed, based on foils of 66*66 cm. GEMs of such dimensions had not been made before, and innovations to the existing technology were introduced to build this detector. This paper discusses these innovations and presents further work on large area GEM development. A single-mask technique overcomes the cumbersome p… ▽ More

    Submitted 26 November, 2009; v1 submitted 28 September, 2009; originally announced September 2009.

    Comments: Contribution to the MPGD'09 conference, Crete, Greece

    Journal ref: JINST 4:P12009,2009

  35. Making spherical GEMs

    Authors: Serge Duarte Pinto, Marco Villa, Matteo Alfonsi, Ian Brock, Gabriele Croci, Eric David, Rui de Oliveira, Leszek Ropelewski, Miranda van Stenis, Hans Taureg

    Abstract: We developed a method to make GEM foils with a spherical geometry. Tests of this procedure and with the resulting spherical GEMs are presented. Together with a spherical drift electrode, a spherical conversion gap for x-rays can be formed. This would eliminate the parallax error in an x-ray diffraction setup, which limits the spatial resolution at wide diffraction angles. The method is inexpensi… ▽ More

    Submitted 6 November, 2009; v1 submitted 18 September, 2009; originally announced September 2009.

    Comments: Contribution to the proceedings of the MPGD'09 conference, Crete

    Journal ref: JINST 4:P12006,2009