-
First demonstration of in-beam performance of bent Monolithic Active Pixel Sensors
Authors:
ALICE ITS project,
:,
G. Aglieri Rinella,
M. Agnello,
B. Alessandro,
F. Agnese,
R. S. Akram,
J. Alme,
E. Anderssen,
D. Andreou,
F. Antinori,
N. Apadula,
P. Atkinson,
R. Baccomi,
A. Badalà,
A. Balbino,
C. Bartels,
R. Barthel,
F. Baruffaldi,
I. Belikov,
S. Beole,
P. Becht,
A. Bhatti,
M. Bhopal,
N. Bianchi
, et al. (230 additional authors not shown)
Abstract:
A novel approach for designing the next generation of vertex detectors foresees to employ wafer-scale sensors that can be bent to truly cylindrical geometries after thinning them to thicknesses of 20-40$μ$m. To solidify this concept, the feasibility of operating bent MAPS was demonstrated using 1.5$\times$3cm ALPIDE chips. Already with their thickness of 50$μ$m, they can be successfully bent to ra…
▽ More
A novel approach for designing the next generation of vertex detectors foresees to employ wafer-scale sensors that can be bent to truly cylindrical geometries after thinning them to thicknesses of 20-40$μ$m. To solidify this concept, the feasibility of operating bent MAPS was demonstrated using 1.5$\times$3cm ALPIDE chips. Already with their thickness of 50$μ$m, they can be successfully bent to radii of about 2cm without any signs of mechanical or electrical damage. During a subsequent characterisation using a 5.4GeV electron beam, it was further confirmed that they preserve their full electrical functionality as well as particle detection performance.
In this article, the bending procedure and the setup used for characterisation are detailed. Furthermore, the analysis of the beam test, including the measurement of the detection efficiency as a function of beam position and local inclination angle, is discussed. The results show that the sensors maintain their excellent performance after bending to radii of 2cm, with detection efficiencies above 99.9% at typical operating conditions, paving the way towards a new class of detectors with unprecedented low material budget and ideal geometrical properties.
△ Less
Submitted 17 August, 2021; v1 submitted 27 May, 2021;
originally announced May 2021.
-
Charge collection properties of TowerJazz 180 nm CMOS Pixel Sensors in dependence of pixel geometries and bias parameters, studied using a dedicated test-vehicle: the Investigator chip
Authors:
G. Aglieri Rinella,
G. Chaosong,
A. di Mauro,
J. Eum,
H. Hillemanns,
A. Junique,
M. Keil,
D. Kim,
H. Kim,
T. Kugathasan,
S. Lee,
M. Mager,
V. Manzari,
C. A. Marin Tobon,
P. Martinengo,
H. Mugnier,
L. Musa,
F. Reidt,
J. Rousset,
K. Sielewicz,
W. Snoeys,
M. Šuljić,
J. W. van Hoorne,
Q. M. Waheed,
P. Yang
, et al. (1 additional authors not shown)
Abstract:
This paper contains a compilation of parameters influencing the charge collection process extracted from a comprehensive study of partially depleted Monolithic Active Pixel Sensors with small (<25 um$^2$) collection electrodes fabricated in the TowerJazz 180 nm CMOS process. These results gave guidance for the optimisation of the diode implemented in ALPIDE, the chip used in the second generation…
▽ More
This paper contains a compilation of parameters influencing the charge collection process extracted from a comprehensive study of partially depleted Monolithic Active Pixel Sensors with small (<25 um$^2$) collection electrodes fabricated in the TowerJazz 180 nm CMOS process. These results gave guidance for the optimisation of the diode implemented in ALPIDE, the chip used in the second generation Inner Tracking System of ALICE, and serve as reference for future simulation studies of similar devices. The studied parameters include: reverse substrate bias, epitaxial layer thickness, charge collection electrode size and the spacing of the electrode to surrounding in-pixel electronics. The results from pixels of 28 um pitch confirm that even in partially depleted circuits, charge collection can be fast (<10 ns), and quantify the influence of the parameters onto the signal sharing and amplitudes, highlighting the importance of a correct spacing between wells and of the impact of the reverse substrate bias.
△ Less
Submitted 23 September, 2020; v1 submitted 22 September, 2020;
originally announced September 2020.
-
The Compact Linear Collider (CLIC) - 2018 Summary Report
Authors:
The CLIC,
CLICdp collaborations,
:,
T. K. Charles,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
M. Volpi,
C. Balazs,
K. Afanaciev,
V. Makarenko,
A. Patapenka,
I. Zhuk,
C. Collette,
M. J. Boland,
A. C. Abusleme Hoffman,
M. A. Diaz,
F. Garay,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu,
X. Wang,
J. Zhang
, et al. (671 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the…
▽ More
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the detector. CLIC is foreseen to be built and operated in stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. CLIC uses a two-beam acceleration scheme, in which 12 GHz accelerating structures are powered via a high-current drive beam. For the first stage, an alternative with X-band klystron powering is also considered. CLIC accelerator optimisation, technical developments and system tests have resulted in an increased energy efficiency (power around 170 MW) for the 380 GeV stage, together with a reduced cost estimate at the level of 6 billion CHF. The detector concept has been refined using improved software tools. Significant progress has been made on detector technology developments for the tracking and calorimetry systems. A wide range of CLIC physics studies has been conducted, both through full detector simulations and parametric studies, together providing a broad overview of the CLIC physics potential. Each of the three energy stages adds cornerstones of the full CLIC physics programme, such as Higgs width and couplings, top-quark properties, Higgs self-coupling, direct searches, and many precision electroweak measurements. The interpretation of the combined results gives crucial and accurate insight into new physics, largely complementary to LHC and HL-LHC. The construction of the first CLIC energy stage could start by 2026. First beams would be available by 2035, marking the beginning of a broad CLIC physics programme spanning 25-30 years.
△ Less
Submitted 6 May, 2019; v1 submitted 14 December, 2018;
originally announced December 2018.
-
R&D results on a CsI-TTGEM based photodetector
Authors:
A. Breskin,
V. Peskov,
A. Di Mauro,
P. Martineng,
D. Mayani Paras,
L. Molnar,
E. Nappi,
G. Paic,
J. van Hoorne
Abstract:
The very high momentum particle identification detector proposed for the ALICE upgrade is a focusing RICH using a C4F10 gaseous radiator. For the detection of Cherenkov photons, one of the options currently under investigation is to use a CsI coated Triple-Thick-GEM (CsI-TTGEM) with metallic or resistive electrodes. We will present results from the laboratory studies as well as preliminary results…
▽ More
The very high momentum particle identification detector proposed for the ALICE upgrade is a focusing RICH using a C4F10 gaseous radiator. For the detection of Cherenkov photons, one of the options currently under investigation is to use a CsI coated Triple-Thick-GEM (CsI-TTGEM) with metallic or resistive electrodes. We will present results from the laboratory studies as well as preliminary results of beam tests of a RICH detector prototype consisting of a CaF2 radiator coupled to a 10x10 cm2 CsI-TTGEM equipped with a pad readout and GASSIPLEX-based front-end electronics. With such a prototype the detection of Cherenkov photons simultaneously with minimum ionizing particles has been achieved for the first time in a stable operation mode.
△ Less
Submitted 13 September, 2010;
originally announced September 2010.