Skip to main content

Showing 1–5 of 5 results for author: Van Doninck, W

Searching in archive physics. Search in all archives.
.
  1. arXiv:1606.04291  [pdf, other

    physics.ins-det hep-ex

    R&D towards the CMS RPC Phase-2 upgrade

    Authors: A. Fagot, A. Cimmino, S. Crucy, M. Gul, A. A. O. Rios, M. Tytgat, N. Zaganidis, S. Aly, Y. Assran, A. Radi, A. Sayed, G. Singh, M. Abbrescia, G. Iaselli, M. Maggi, G. Pugliese, P. Verwilligen, W. Van Doninck, S. Colafranceschi, A. Sharma, L. Benussi, S. Bianco, D. Piccolo, F. Primavera, V. Bhatnagar , et al. (71 additional authors not shown)

    Abstract: The high pseudo-rapidity region of the CMS muon system is covered by Cathode Strip Chambers (CSC) only and lacks redundant coverage despite the fact that it is a challenging region for muons in terms of backgrounds and momentum resolution. In order to maintain good efficiency for the muon trigger in this region additional RPCs are planned to be installed in the two outermost stations at low angle… ▽ More

    Submitted 14 June, 2016; originally announced June 2016.

    Comments: 13th Workshop on Resistive Plate Chambers and related detectors, 22-26 February 2016, Ghent University, Belgium

  2. arXiv:1606.01398  [pdf, other

    physics.ins-det hep-ex

    High rate, fast timing Glass RPC for the high η CMS muon detectors

    Authors: F. Lagarde, M. Gouzevitch, I. Laktineh, V. Buridon, X. Chen, C. Combaret, A. Eynard, L. Germani, G. Grenier, H. Mathez, L. Mirabito, A. Petrukhin, A. Steen, W. Tromeuraa, Y. Wang, A. Gongab, N. Moreau, C. de la Taille, F. Dulucqac, A. Cimmino, S. Crucy, A. Fagot, M. Gul, A. A. O. Rios, M. Tytgat , et al. (86 additional authors not shown)

    Abstract: The HL-LHC phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. To achieve this goal in a reasonable time scale the instantaneous luminosity would also increase by an order of magnitude up to $6.10^{34} cm^{-2} s^{-1}$ . The region of the forward muon spectrometer ($|η| > 1.6$) is not equipped with RPC stations. The increase of the expec… ▽ More

    Submitted 22 July, 2016; v1 submitted 4 June, 2016; originally announced June 2016.

    Comments: 14 pages, 11 figures, Conference proceeding for the 2016 Resistive Plate Chambers and Related Detectors

  3. arXiv:1605.06798  [pdf

    physics.ins-det hep-ex

    Performance of Resistive Plate Chambers installed during the first long shutdown of the CMS experiment

    Authors: M. Shopova, A. Aleksandrov, R. Hadjiiska, P. Iaydjiev, G. Sultanov, M. Rodozov, S. Stoykova, Y. Assran, A. Sayed, A. Radi, S. Aly, G. Singh, M. Abbrescia, G. Iaselli, M. Maggi, G. Pugliese, P. Verwilligen, W. Van Doninck, S. Colafranceschi, A. Sharma, L. Benussi, S. Bianco, D. Piccolo, F. Primavera, A. Cimmino , et al. (71 additional authors not shown)

    Abstract: The CMS experiment, located at the CERN Large Hadron Collider, has a redundant muon system composed by three different detector technologies: Cathode Strip Chambers (in the forward regions), Drift Tubes (in the central region) and Resistive Plate Chambers (both its central and forward regions). All three are used for muon reconstruction and triggering. During the first long shutdown (LS1) of the L… ▽ More

    Submitted 22 May, 2016; originally announced May 2016.

    Comments: 5 pages, 6 figures, proceeding to The XIII workshop on Resistive Plate Chambers and Related Detectors (RPC2016)

    Report number: CMS CR-2016/090

  4. arXiv:1605.00440  [pdf

    physics.ins-det hep-ex

    Radiation Tests of Real-Sized Prototype RPCs for the Future CMS RPC Upscope

    Authors: K. S. Lee, S. Choi, B. S. Hong, M. Jo, J. W. Kang, M. Kang, H. Kim, K. Lee, S. K. Parka, A. Cimmino, S. Crucy, A. Fagot, M. Gul, A. A. O. Rios, M. Tytgat, N. Zaganidis, S. Ali, Y. Assran, A. Radi, A. Sayed, G. Singh, M. Abbrescia, G. Iaselli, M. Maggi, G. Pugliese , et al. (71 additional authors not shown)

    Abstract: We report on a systematic study of double-gap and four-gap phenolic resistive plate chambers (RPCs) for future high-η RPC triggers in the CMS. In the present study, we constructed real-sized double-gap and four-gap RPCs with gap thicknesses of 1.6 and 0.8 mm, respectively, with 2-mm-thick phenolic high-pressure-laminated (HPL) plates. We examined the prototype RPCs for cosmic rays and 100 GeV muon… ▽ More

    Submitted 4 May, 2016; v1 submitted 2 May, 2016; originally announced May 2016.

    Comments: Conference proceeding for the 2016 Resistive Plate Chambers and Related Detectors 8 pages, 9 figures

  5. Performance of the gas gain monitoring system of the CMS RPC muon detector

    Authors: L. Benussi, S. Bianco, L. Passamonti, D. Piccolo, D. Pierluigi, G. Raffone, A. Russo, G. Saviano, Y. Ban, J. Cai, Q. Li, S. Liu, S. Qian, D. Wang, Z. Xu, F. Zhang, Y. Choi, D. Kim, S. Choi, B. Hong, J. W. Kang, M. Kang, J. H. Kwon, K. S. Lee, S. K. Park , et al. (60 additional authors not shown)

    Abstract: The RPC muon detector of the CMS experiment at the LHC (CERN, Geneva, Switzerland) is equipped with a Gas Gain Monitoring (GGM) system. A report on the stability of the system during the 2011-2012 data taking run is given, as well as the observation of an effect which suggests a novel method for the monitoring of gas mixture composition.

    Submitted 27 December, 2014; originally announced December 2014.

    Comments: Presented at RPC2014, Bei**g, China. Accepted for publication on JINST

    Report number: INFN-14-22/LNF