RT-utils: A Minimal Python Library for RT-struct Manipulation
Authors:
Asim Shrestha,
Adam Watkins,
Fereshteh Yousefirizi,
Arman Rahmim,
Carlos F. Uribe
Abstract:
Towards the need for automated and precise AI-based analysis of medical images, we present RT-utils, a specialized Python library tuned for the manipulation of radiotherapy (RT) structures stored in DICOM format. RT-utils excels in converting the polygon contours into binary masks, ensuring accuracy and efficiency. By converting DICOM RT structures into standardized formats such as NumPy arrays an…
▽ More
Towards the need for automated and precise AI-based analysis of medical images, we present RT-utils, a specialized Python library tuned for the manipulation of radiotherapy (RT) structures stored in DICOM format. RT-utils excels in converting the polygon contours into binary masks, ensuring accuracy and efficiency. By converting DICOM RT structures into standardized formats such as NumPy arrays and SimpleITK Images, RT-utils optimizes inputs for computational solutions such as AI-based automated segmentation techniques or radiomics analysis. Since its inception in 2020, RT-utils has been used extensively with a focus on simplifying complex data processing tasks. RT-utils offers researchers a powerful solution to enhance workflows and drive significant advancements in medical imaging.
△ Less
Submitted 9 May, 2024;
originally announced May 2024.
-
Novel Method to Estimate Kinetic Microparameters from Dynamic Whole-Body Imaging in Regular-Axial Field-of-View PET Scanners
Authors:
Kyung-Nam Lee,
Arman Rahmim,
Carlos Uribe
Abstract:
For whole-body (WB) kinetic modeling based on a typical PET scanner, a multi-pass multi-bed scanning protocol is necessary given the limited axial field-of-view. Such a protocol introduces loss of early-dynamics in time-activity curves (TACs) and sparsity in TAC measurements, inducing uncertainty in parameter estimation when using least-squares estimation (LSE) (i.e., common standard) especially f…
▽ More
For whole-body (WB) kinetic modeling based on a typical PET scanner, a multi-pass multi-bed scanning protocol is necessary given the limited axial field-of-view. Such a protocol introduces loss of early-dynamics in time-activity curves (TACs) and sparsity in TAC measurements, inducing uncertainty in parameter estimation when using least-squares estimation (LSE) (i.e., common standard) especially for kinetic microparameters. We present a method to reliably estimate microparameters, enabling accurate parametric imaging, on regular-axial field-of-view PET scanners. Our method, denoted parameter combination-driven estimation (PCDE), relies on generation of reference truth TAC database, and subsequently selecting, the best parameter combination as the one arriving at TAC with highest total similarity score (TSS), focusing on general image quality, overall visibility, and tumor detectability metrics. Our technique has two distinctive characteristics: 1) improved probability of having one-on-one map** between early and late dynamics in TACs (the former missing from typical protocols), and 2) use of multiple aspects of TACs in selection of best fits. To evaluate our method against conventional LSE, we plotted tradeoff curves for noise and bias. In addition, the overall SNR and spatial noise were calculated and compared. Furthermore, CNR and TBR were also calculated. We also tested our proposed method on patient data (18F-DCFPyL PET scans) to further verify clinical applicability. Significantly improved general image quality performance was verified in microparametric images (e.g. noise-bias performance). The overall visibility and tumor detectability were also improved. Finally, for our patient studies, improved overall visibility and tumor detectability were demonstrated in micoparametric images, compared to use of conventional parameter estimation.
△ Less
Submitted 13 May, 2024; v1 submitted 15 April, 2024;
originally announced April 2024.
-
A slice classification neural network for automated classification of axial PET/CT slices from a multi-centric lymphoma dataset
Authors:
Shadab Ahamed,
Yixi Xu,
Ingrid Bloise,
Joo H. O,
Carlos F. Uribe,
Rahul Dodhia,
Juan L. Ferres,
Arman Rahmim
Abstract:
Automated slice classification is clinically relevant since it can be incorporated into medical image segmentation workflows as a preprocessing step that would flag slices with a higher probability of containing tumors, thereby directing physicians attention to the important slices. In this work, we train a ResNet-18 network to classify axial slices of lymphoma PET/CT images (collected from two in…
▽ More
Automated slice classification is clinically relevant since it can be incorporated into medical image segmentation workflows as a preprocessing step that would flag slices with a higher probability of containing tumors, thereby directing physicians attention to the important slices. In this work, we train a ResNet-18 network to classify axial slices of lymphoma PET/CT images (collected from two institutions) depending on whether the slice intercepted a tumor (positive slice) in the 3D image or if the slice did not (negative slice). Various instances of the network were trained on 2D axial datasets created in different ways: (i) slice-level split and (ii) patient-level split; inputs of different types were used: (i) only PET slices and (ii) concatenated PET and CT slices; and different training strategies were employed: (i) center-aware (CAW) and (ii) center-agnostic (CAG). Model performances were compared using the area under the receiver operating characteristic curve (AUROC) and the area under the precision-recall curve (AUPRC), and various binary classification metrics. We observe and describe a performance overestimation in the case of slice-level split as compared to the patient-level split training. The model trained using patient-level split data with the network input containing only PET slices in the CAG training regime was the best performing/generalizing model on a majority of metrics. Our models were additionally more closely compared using the sensitivity metric on the positive slices from their respective test sets.
△ Less
Submitted 11 March, 2024;
originally announced March 2024.
-
A cascaded deep network for automated tumor detection and segmentation in clinical PET imaging of diffuse large B-cell lymphoma
Authors:
Shadab Ahamed,
Natalia Dubljevic,
Ingrid Bloise,
Claire Gowdy,
Patrick Martineau,
Don Wilson,
Carlos F. Uribe,
Arman Rahmim,
Fereshteh Yousefirizi
Abstract:
Accurate detection and segmentation of diffuse large B-cell lymphoma (DLBCL) from PET images has important implications for estimation of total metabolic tumor volume, radiomics analysis, surgical intervention and radiotherapy. Manual segmentation of tumors in whole-body PET images is time-consuming, labor-intensive and operator-dependent. In this work, we develop and validate a fast and efficient…
▽ More
Accurate detection and segmentation of diffuse large B-cell lymphoma (DLBCL) from PET images has important implications for estimation of total metabolic tumor volume, radiomics analysis, surgical intervention and radiotherapy. Manual segmentation of tumors in whole-body PET images is time-consuming, labor-intensive and operator-dependent. In this work, we develop and validate a fast and efficient three-step cascaded deep learning model for automated detection and segmentation of DLBCL tumors from PET images. As compared to a single end-to-end network for segmentation of tumors in whole-body PET images, our three-step model is more effective (improves 3D Dice score from 58.9% to 78.1%) since each of its specialized modules, namely the slice classifier, the tumor detector and the tumor segmentor, can be trained independently to a high degree of skill to carry out a specific task, rather than a single network with suboptimal performance on overall segmentation.
△ Less
Submitted 11 March, 2024;
originally announced March 2024.
-
Investigating heterogeneous PSMA ligand uptake inside parotid glands
Authors:
Caleb Sample,
Carlos Uribe,
Arman Rahmim,
François Bénard,
Jonn Wu,
Haley Clark
Abstract:
The purpose was to investigate the spatial heterogeneity of prostate-specific membrane antigen (PSMA) positron emission tomography (PET) uptake within parotid glands. We aim to quantify patterns in well-defined regions to facilitate further investigations. Furthermore, we investigate whether uptake is correlated with computed tomography (CT) texture features. Parotid glands from [18F]DCFPyL PSMA P…
▽ More
The purpose was to investigate the spatial heterogeneity of prostate-specific membrane antigen (PSMA) positron emission tomography (PET) uptake within parotid glands. We aim to quantify patterns in well-defined regions to facilitate further investigations. Furthermore, we investigate whether uptake is correlated with computed tomography (CT) texture features. Parotid glands from [18F]DCFPyL PSMA PET/CT images of 30 prostate cancer patients were analyzed. Thresholding was used to define high-uptake regions, and uptake statistics were computed within various divisions. Spearman's rank correlation coefficient was calculated between PSMA PET uptake and the Grey Level Run Length Matrix (GLRLM) using a long and short run length emphasis (GLRLML and GLRLMS) in subregions of parotid glands. PSMA PET uptake was significantly higher (p < 0.001) in lateral/posterior regions of the glands than anterior/medial regions. Maximum uptake was found in the lateral half of parotid glands in 50 out of 60 glands. The difference in SUV between parotid halves is greatest when parotids are divided by a plane separating the anterior/medial and posterior/lateral halves symmetrically. PSMA PET uptake was significantly correlated with CT GLRLML (p < 0.001), and anti-correlated with CT GLRLMS (p < 0.001). Uptake of PSMA PET is heterogeneous within parotid glands, with uptake biased towards lateral and posterior regions. Uptake patterns within parotid glands were found to be strongly correlated with CT texture features, suggesting the possible future use of CT texture features as a proxy for inferring PSMA PET uptake in salivary glands.
△ Less
Submitted 4 January, 2024;
originally announced January 2024.
-
Observer study-based evaluation of TGAN architecture used to generate oncological PET images
Authors:
Roberto Fedrigo,
Fereshteh Yousefirizi,
Zi** Liu,
Abhinav K. Jha,
Robert V. Bergen,
Jean-Francois Rajotte,
Raymond T. Ng,
Ingrid Bloise,
Sara Harsini,
Dan J. Kadrmas,
Carlos Uribe,
Arman Rahmim
Abstract:
The application of computer-vision algorithms in medical imaging has increased rapidly in recent years. However, algorithm training is challenging due to limited sample sizes, lack of labeled samples, as well as privacy concerns regarding data sharing. To address these issues, we previously developed (Bergen et al. 2022) a synthetic PET dataset for Head and Neck (H and N) cancer using the temporal…
▽ More
The application of computer-vision algorithms in medical imaging has increased rapidly in recent years. However, algorithm training is challenging due to limited sample sizes, lack of labeled samples, as well as privacy concerns regarding data sharing. To address these issues, we previously developed (Bergen et al. 2022) a synthetic PET dataset for Head and Neck (H and N) cancer using the temporal generative adversarial network (TGAN) architecture and evaluated its performance segmenting lesions and identifying radiomics features in synthesized images. In this work, a two-alternative forced-choice (2AFC) observer study was performed to quantitatively evaluate the ability of human observers to distinguish between real and synthesized oncological PET images. In the study eight trained readers, including two board-certified nuclear medicine physicians, read 170 real/synthetic image pairs presented as 2D-transaxial using a dedicated web app. For each image pair, the observer was asked to identify the real image and input their confidence level with a 5-point Likert scale. P-values were computed using the binomial test and Wilcoxon signed-rank test. A heat map was used to compare the response accuracy distribution for the signed-rank test. Response accuracy for all observers ranged from 36.2% [27.9-44.4] to 63.1% [54.8-71.3]. Six out of eight observers did not identify the real image with statistical significance, indicating that the synthetic dataset was reasonably representative of oncological PET images. Overall, this study adds validity to the realism of our simulated H&N cancer dataset, which may be implemented in the future to train AI algorithms while favoring patient confidentiality and privacy protection.
△ Less
Submitted 27 November, 2023; v1 submitted 27 November, 2023;
originally announced November 2023.
-
A Discrete-time Networked Competitive Bivirus SIS Model
Authors:
Sebin Gracy,
Ji Liu,
Tamer Basar,
Cesar A. Uribe
Abstract:
The paper deals with the analysis of a discrete-time networked competitive bivirus susceptible-infected-susceptible (SIS) model. More specifically, we suppose that virus 1 and virus 2 are circulating in the population and are in competition with each other. We show that the model is strongly monotone, and that, under certain assumptions, it does not admit any periodic orbit. We identify a sufficie…
▽ More
The paper deals with the analysis of a discrete-time networked competitive bivirus susceptible-infected-susceptible (SIS) model. More specifically, we suppose that virus 1 and virus 2 are circulating in the population and are in competition with each other. We show that the model is strongly monotone, and that, under certain assumptions, it does not admit any periodic orbit. We identify a sufficient condition for exponential convergence to the disease-free equilibrium (DFE). Assuming only virus 1 (resp. virus 2) is alive, we establish a condition for global asymptotic convergence to the single-virus endemic equilibrium of virus 1 (resp. virus 2) -- our proof does not rely on the construction of a Lyapunov function. Assuming both virus 1 and virus 2 are alive, we establish a condition which ensures local exponential convergence to the single-virus equilibrium of virus 1 (resp. virus 2). Finally, we provide a sufficient (resp. necessary) condition for the existence of a coexistence equilibrium.
△ Less
Submitted 20 October, 2023;
originally announced October 2023.
-
PyTomography: A Python Library for Quantitative Medical Image Reconstruction
Authors:
Lucas Polson,
Roberto Fedrigo,
Chenguang Li,
Maziar Sabouri,
Obed Dzikunu,
Shadab Ahamed,
Nikolaos Karakatsanis,
Arman Rahmim,
Carlos Uribe
Abstract:
There is a need for open-source libraries in emission tomography that (i) use modern and popular backend code to encourage community contributions and (ii) offer support for the multitude of reconstruction algorithms available in recent literature, such as those that employ artificial intelligence. The purpose of this research was to create and evaluate a GPU-accelerated, open-source, and user-fri…
▽ More
There is a need for open-source libraries in emission tomography that (i) use modern and popular backend code to encourage community contributions and (ii) offer support for the multitude of reconstruction algorithms available in recent literature, such as those that employ artificial intelligence. The purpose of this research was to create and evaluate a GPU-accelerated, open-source, and user-friendly image reconstruction library, designed to serve as a central platform for the development, validation, and deployment of various tomographic reconstruction algorithms. PyTomography was developed using Python and inherits the GPU-accelerated functionality of PyTorch and parallelproj for fast computations. Its flexible and modular design decouples system matrices, likelihoods, and reconstruction algorithms, simplifying the process of integrating new imaging modalities using various python tools. Example use cases demonstrate the software capabilities in parallel hole SPECT and listmode PET imaging. Overall, we have developed and publicly share PyTomography, a highly optimized and user-friendly software for medical image reconstruction, with a class hierarchy that fosters the development of novel imaging applications.
△ Less
Submitted 7 July, 2024; v1 submitted 5 September, 2023;
originally announced September 2023.
-
Neural blind deconvolution for deblurring and supersampling PSMA PET
Authors:
Caleb Sample,
Arman Rahmim,
Carlos Uribe,
François Bénard,
Jonn Wu,
Roberto Fedrigo,
Haley Clark
Abstract:
Objective: To simultaneously deblur and supersample prostate specific membrane antigen (PSMA) positron emission tomography (PET) images using neural blind deconvolution. Approach: Blind deconvolution is a method of estimating the hypothetical "deblurred" image along with the blur kernel (related to the point spread function) simultaneously. Traditional \textit{maximum a posteriori} blind deconvolu…
▽ More
Objective: To simultaneously deblur and supersample prostate specific membrane antigen (PSMA) positron emission tomography (PET) images using neural blind deconvolution. Approach: Blind deconvolution is a method of estimating the hypothetical "deblurred" image along with the blur kernel (related to the point spread function) simultaneously. Traditional \textit{maximum a posteriori} blind deconvolution methods require stringent assumptions and suffer from convergence to a trivial solution. A method of modelling the deblurred image and kernel with independent neural networks, called "neural blind deconvolution" had demonstrated success for deblurring 2D natural images in 2020. In this work, we adapt neural blind deconvolution for PVE correction of PSMA PET images with simultaneous supersampling. We compare this methodology with several interpolation methods, using blind image quality metrics, and test the model's ability to predict kernels by re-running the model after applying artificial "pseudokernels" to deblurred images. The methodology was tested on a retrospective set of 30 prostate patients as well as phantom images containing spherical lesions of various volumes. Results: Neural blind deconvolution led to improvements in image quality over other interpolation methods in terms of blind image quality metrics, recovery coefficients, and visual assessment. Predicted kernels were similar between patients, and the model accurately predicted several artificially-applied pseudokernels. Localization of activity in phantom spheres was improved after deblurring, allowing small lesions to be more accurately defined. Significance: The intrinsically low spatial resolution of PSMA PET leads to PVEs which negatively impact uptake quantification in small regions. The proposed method can be used to mitigate this issue, and can be straightforwardly adapted for other imaging modalities.
△ Less
Submitted 2 March, 2024; v1 submitted 1 September, 2023;
originally announced September 2023.
-
Multi-Competitive Virus Spread over a Time-Varying Networked SIS Model with an Infrastructure Network
Authors:
Sebin Gracy,
Yuan Wang,
Philip E. Pare,
Cesar A Uribe
Abstract:
We study the spread of multi-competitive viruses over a (possibly) time-varying network of individuals accounting for the presence of shared infrastructure networks that further enables transmission of the virus. We establish a sufficient condition for exponentially fast eradication of a virus for: 1) time-invariant graphs, 2) time-varying graphs with symmetric interactions between individuals and…
▽ More
We study the spread of multi-competitive viruses over a (possibly) time-varying network of individuals accounting for the presence of shared infrastructure networks that further enables transmission of the virus. We establish a sufficient condition for exponentially fast eradication of a virus for: 1) time-invariant graphs, 2) time-varying graphs with symmetric interactions between individuals and homogeneous virus spread across the network (same healing and infection rate for all individuals), and 3) directed and slowly varying graphs with heterogeneous virus spread (not necessarily same healing and infection rates for all individuals) across the network. Numerical examples illustrate our theoretical results and indicate that, for the time-varying case, violation of the aforementioned sufficient conditions could lead to the persistence of a virus.
△ Less
Submitted 15 March, 2023;
originally announced March 2023.
-
$^{177}$Lu SPECT Imaging in the Presence of $^{90}$Y: Does $^{90}$Y Degrade Image Quantification? A Simulation Study
Authors:
Cassandra Miller,
Carlos Uribe,
Xinchi Hou,
Arman Rahmim,
Anna Celler
Abstract:
This work aims to investigate the accuracy of quantitative SPECT imaging of $^{177}$Lu in the presence of $^{90}$Y, which occurs in dual-isotope radiopharmaceutical therapy (RPT) involving both isotopes. We used the GATE Monte Carlo simulation toolkit to conduct a phantom study, simulating spheres filled with $^{177}$Lu and $^{90}$Y placed in a cylindrical water phantom that was also filled with a…
▽ More
This work aims to investigate the accuracy of quantitative SPECT imaging of $^{177}$Lu in the presence of $^{90}$Y, which occurs in dual-isotope radiopharmaceutical therapy (RPT) involving both isotopes. We used the GATE Monte Carlo simulation toolkit to conduct a phantom study, simulating spheres filled with $^{177}$Lu and $^{90}$Y placed in a cylindrical water phantom that was also filled with activity of both radionuclides. We simulated multiple phantom configurations and activity combinations by varying the location of the spheres, the concentrations of $^{177}$Lu and $^{90}$Y in the spheres, and the amount of background activity. We investigated two different scatter window widths to be used with triple energy window (TEW) scatter correction. We also created multiple realizations of each configuration to improve our assessment, leading to a total of 540 simulations. Each configuration was imaged using a simulated Siemens SPECT camera. The projections were reconstructed using the standard 3D OSEM algorithm, and errors associated with $^{177}$Lu activity quantification and contrast-to-noise ratios (CNRs) were determined. In all configurations, the quantification error was within $\pm$6% of the no-$^{90}$Y case, and we found that quantitative accuracy may slightly improve when $^{90}$Y is present because of reduction of errors associated with TEW scatter correction. The CNRs were not significantly impacted by the presence of $^{90}$Y, but they were increased when a wider scatter window width was used for TEW scatter correction. The width of the scatter windows made a small but statistically significant difference of 1-2% on the recovered $^{177}$Lu activity. Based on these results, we can conclude that activity quantification of $^{177}$Lu and lesion detectability is not degraded by the presence of $^{90}$Y.
△ Less
Submitted 25 January, 2023;
originally announced January 2023.
-
Semi-supervised learning towards automated segmentation of PET images with limited annotations: Application to lymphoma patients
Authors:
Fereshteh Yousefirizi,
Isaac Shiri,
Joo Hyun O,
Ingrid Bloise,
Patrick Martineau,
Don Wilson,
François Bénard,
Laurie H. Sehn,
Kerry J. Savage,
Habib Zaidi,
Carlos F. Uribe,
Arman Rahmim
Abstract:
The time-consuming task of manual segmentation challenges routine systematic quantification of disease burden. Convolutional neural networks (CNNs) hold significant promise to reliably identify locations and boundaries of tumors from PET scans. We aimed to leverage the need for annotated data via semi-supervised approaches, with application to PET images of diffuse large B-cell lymphoma (DLBCL) an…
▽ More
The time-consuming task of manual segmentation challenges routine systematic quantification of disease burden. Convolutional neural networks (CNNs) hold significant promise to reliably identify locations and boundaries of tumors from PET scans. We aimed to leverage the need for annotated data via semi-supervised approaches, with application to PET images of diffuse large B-cell lymphoma (DLBCL) and primary mediastinal large B-cell lymphoma (PMBCL). We analyzed 18F-FDG PET images of 292 patients with PMBCL (n=104) and DLBCL (n=188) (n=232 for training and validation, and n=60 for external testing). We employed FCM and MS losses for training a 3D U-Net with different levels of supervision: i) fully supervised methods with labeled FCM (LFCM) as well as Unified focal and Dice loss functions, ii) unsupervised methods with Robust FCM (RFCM) and Mumford-Shah (MS) loss functions, and iii) Semi-supervised methods based on FCM (RFCM+LFCM), as well as MS loss in combination with supervised Dice loss (MS+Dice). Unified loss function yielded higher Dice score (mean +/- standard deviation (SD)) (0.73 +/- 0.03; 95% CI, 0.67-0.8) compared to Dice loss (p-value<0.01). Semi-supervised (RFCM+alpha*LFCM) with alpha=0.3 showed the best performance, with a Dice score of 0.69 +/- 0.03 (95% CI, 0.45-0.77) outperforming (MS+alpha*Dice) for any supervision level (any alpha) (p<0.01). The best performer among (MS+alpha*Dice) semi-supervised approaches with alpha=0.2 showed a Dice score of 0.60 +/- 0.08 (95% CI, 0.44-0.76) compared to another supervision level in this semi-supervised approach (p<0.01). Semi-supervised learning via FCM loss (RFCM+alpha*LFCM) showed improved performance compared to supervised approaches. Considering the time-consuming nature of expert manual delineations and intra-observer variabilities, semi-supervised approaches have significant potential for automated segmentation workflows.
△ Less
Submitted 25 March, 2024; v1 submitted 19 December, 2022;
originally announced December 2022.
-
Convolutional neural network with a hybrid loss function for fully automated segmentation of lymphoma lesions in FDG PET images
Authors:
Fereshteh Yousefirizi,
Natalia Dubljevic,
Shadab Ahamed,
Ingrid Bloise,
Claire Gowdy,
Joo Hyun O,
Youssef Farag,
Rodrigue de Schaetzen,
Patrick Martineau,
Don Wilson,
Carlos F. Uribe,
Arman Rahmim
Abstract:
Segmentation of lymphoma lesions is challenging due to their varied sizes and locations in whole-body PET scans. This work presents a fully-automated segmentation technique using a multi-center dataset of diffuse large B-cell lymphoma (DLBCL) with heterogeneous characteristics. We utilized a dataset of [18F]FDG-PET scans (n=194) from two different imaging centers, including cases with primary medi…
▽ More
Segmentation of lymphoma lesions is challenging due to their varied sizes and locations in whole-body PET scans. This work presents a fully-automated segmentation technique using a multi-center dataset of diffuse large B-cell lymphoma (DLBCL) with heterogeneous characteristics. We utilized a dataset of [18F]FDG-PET scans (n=194) from two different imaging centers, including cases with primary mediastinal large B-cell lymphoma (PMBCL) (n=104). Automated brain and bladder removal approaches were utilized as preprocessing steps to tackle false positives caused by normal hypermetabolic uptake in these organs. Our segmentation model is a convolutional neural network (CNN) based on a 3D U-Net architecture that includes squeeze and excitation (SE) modules. Hybrid distribution, region, and boundary-based losses (Unified Focal and Mumford-Shah (MS)) were utilized that showed the best performance compared to other combinations (p<0.05). Cross-validation between different centers, DLBCL and PMBCL cases, and three random splits were applied on train/validation data. The ensemble of these six models achieved a Dice similarity coefficient (DSC) of 0.77 +- 0.08 and Hausdorff distance (HD) of 16.5 +-12.5. Our 3D U-net model with SE modules for segmentation with hybrid loss performed significantly better (p<0.05) as compared to the 3D U-Net (without SE modules) using the same loss function (Unified Focal and MS loss) (DSC= 0.64 +-0.21 and HD= 26.3 +- 18.7). Our model can facilitate a fully automated quantification pipeline in a multi-center context that opens the possibility for routine reporting of total metabolic tumor volume (TMTV) and other metrics shown useful for the management of lymphoma.
△ Less
Submitted 10 August, 2022; v1 submitted 30 July, 2022;
originally announced August 2022.
-
Tensor Radiomics: Paradigm for Systematic Incorporation of Multi-Flavoured Radiomics Features
Authors:
Arman Rahmim,
Amirhosein Toosi,
Mohammad R. Salmanpour,
Natalia Dubljevic,
Ian Janzen,
Isaac Shiri,
Ren Yuan,
Cheryl Ho,
Habib Zaidi,
Calum MacAulay,
Carlos Uribe,
Fereshteh Yousefirizi
Abstract:
Radiomics features extract quantitative information from medical images, towards the derivation of biomarkers for clinical tasks, such as diagnosis, prognosis, or treatment response assessment. Different image discretization parameters (e.g. bin number or size), convolutional filters, segmentation perturbation, or multi-modality fusion levels can be used to generate radiomics features and ultimate…
▽ More
Radiomics features extract quantitative information from medical images, towards the derivation of biomarkers for clinical tasks, such as diagnosis, prognosis, or treatment response assessment. Different image discretization parameters (e.g. bin number or size), convolutional filters, segmentation perturbation, or multi-modality fusion levels can be used to generate radiomics features and ultimately signatures. Commonly, only one set of parameters is used; resulting in only one value or flavour for a given RF. We propose tensor radiomics (TR) where tensors of features calculated with multiple combinations of parameters (i.e. flavours) are utilized to optimize the construction of radiomics signatures. We present examples of TR as applied to PET/CT, MRI, and CT imaging invoking machine learning or deep learning solutions, and reproducibility analyses: (1) TR via varying bin sizes on CT images of lung cancer and PET-CT images of head & neck cancer (HNC) for overall survival prediction. A hybrid deep neural network, referred to as TR-Net, along with two ML-based flavour fusion methods showed improved accuracy compared to regular rediomics features. (2) TR built from different segmentation perturbations and different bin sizes for classification of late-stage lung cancer response to first-line immunotherapy using CT images. TR improved predicted patient responses. (3) TR via multi-flavour generated radiomics features in MR imaging showed improved reproducibility when compared to many single-flavour features. (4) TR via multiple PET/CT fusions in HNC. Flavours were built from different fusions using methods, such as Laplacian pyramids and wavelet transforms. TR improved overall survival prediction. Our results suggest that the proposed TR paradigm has the potential to improve performance capabilities in different medical imaging tasks.
△ Less
Submitted 24 October, 2022; v1 submitted 11 March, 2022;
originally announced March 2022.
-
Role of AI in Theranostics: Towards Routine Personalized Radiopharmaceutical Therapies
Authors:
Julia Brosch-Lenz,
Fereshteh Yousefirizi,
Katherine Zukotynski,
Jean-Mathieu Beauregard,
Vincent Gaudet,
Babak Saboury,
Arman Rahmim,
Carlos Uribe
Abstract:
We highlight emerging uses of artificial intelligence (AI) in the field of theranostics, focusing on its significant potential to enable routine and reliable personalization of radiopharmaceutical therapies (RPTs). Personalized RPTs require patient-individual dosimetry calculations accompanying therapy. Image-based dosimetry needs: 1) quantitative imaging; 2) co-registration and organ/tumor identi…
▽ More
We highlight emerging uses of artificial intelligence (AI) in the field of theranostics, focusing on its significant potential to enable routine and reliable personalization of radiopharmaceutical therapies (RPTs). Personalized RPTs require patient-individual dosimetry calculations accompanying therapy. Image-based dosimetry needs: 1) quantitative imaging; 2) co-registration and organ/tumor identification on serial and multimodality images; 3) determination of the time-integrated activity; and 4) absorbed dose determination. AI models that facilitate these steps are reviewed. Additionally we discuss the potential to exploit biological information from diagnostic and therapeutic molecular images to derive biomarkers for absorbed dose and outcome prediction, towards personalization of therapies. We try to motivate the nuclear medicine community to expand and align efforts into making routine and reliable personalization of RPTs a reality.
△ Less
Submitted 31 July, 2021; v1 submitted 29 July, 2021;
originally announced July 2021.
-
Development of the Lymphatic System in the 4D XCAT Phantom
Authors:
Roberto Fedrigo,
William P. Segars,
Patrick Martineau,
Claire Gowdy,
Ingrid Bloise,
Carlos F. Uribe,
Arman Rahmim
Abstract:
Purpose: The XCAT phantom allows for highly sophisticated multimodality imaging research. It includes a complete set of organs, muscle, bone, soft tissue, while also accounting for age, sex, and body mass index (BMI), which allows phantom studies to be performed at a population scale. At the same time, the XCAT phantom does not currently include the lymphatic system, critical for evaluating bulky…
▽ More
Purpose: The XCAT phantom allows for highly sophisticated multimodality imaging research. It includes a complete set of organs, muscle, bone, soft tissue, while also accounting for age, sex, and body mass index (BMI), which allows phantom studies to be performed at a population scale. At the same time, the XCAT phantom does not currently include the lymphatic system, critical for evaluating bulky nodal malignancies in lymphoma. We aimed to incorporate a full lymphatic system into the XCAT phantom and to generate realistic simulated images via guidance from lymphoma patient studies.
Methods: A template lymphatic system was extended based on known anatomy was used to define 276 lymph nodes and corresponding vessels using non-uniform rational basis spline (NURBS) surfaces. Lymph node properties were modified using the Rhinoceros 3D viewing software. The XCAT general parameter script was used to input organ concentrations and generate binary files with uptake and attenuation information.
Results: Lymph nodes can be scaled, stretched, and translated within the intuitive Rhinoceros interface, to allow for realistic simulation of different lymph node pathologies. Bulky, heterogeneous PMBCL tumours were generated in the mediastinum using expanded lymph nodes. Our results suggest that optimized thresholding provides better accuracy for determining total metabolic tumour volume (TMTV) of PMBCL tumours, while the gradient method was most accurate for total lesion glycolysis (TLG).
Conclusions: An upgraded XCAT phantom with a fully simulated lymphatic system was created. Distributed to the research community, the XCAT phantom with the new lymphatic system has the potential of enabling studies to optimize image quality and quantitation, towards improved assessment of lymphoma including predictive modeling (e.g. improved TMTV and radiomics research).
△ Less
Submitted 2 August, 2021; v1 submitted 23 July, 2021;
originally announced July 2021.