Comparison of readout systems for high-rate silicon photo-multiplier applications
Authors:
M. L. Wong,
M. Kołodziej,
K. Briggl,
R. Hetzel,
G. Korcyl,
R. Lalik,
A. Malige,
A. Magiera,
G. Ostrzołek,
K. Rusiecka,
A. Stahl,
V. Urbanevych,
M. Wiebusch,
A. Wrońska
Abstract:
Recent years have shown an increased use of silicon photo-multipliers (SiPM) in experiments as they are of reasonable cost, have relatively low power consumption and are easily available in a variety of form factors allowing for a large number of readout channels. At the same time, experiments are generating data at increasingly high rates requiring the use of more efficient readout systems. In th…
▽ More
Recent years have shown an increased use of silicon photo-multipliers (SiPM) in experiments as they are of reasonable cost, have relatively low power consumption and are easily available in a variety of form factors allowing for a large number of readout channels. At the same time, experiments are generating data at increasingly high rates requiring the use of more efficient readout systems. In this work, the dead time, efficiency, dynamic range, coincidence time resolution and energy resolution of five different readout systems at various stages of maturity are evaluated to determine the best system for acquiring data from a detector in a high rate experiment. Additional functionalities of the systems are also discussed.
△ Less
Submitted 8 December, 2023;
originally announced December 2023.
Near-field coded-mask technique and its potential for proton therapy monitoring
Authors:
Ronja Hetzel,
Vitalii Urbanevych,
Andreas Bolke,
Jonas Kasper,
Magdalena Kołodziej,
Monika Kercz,
Andrzej Magiera,
Florian Mueller,
Sara Müller,
Magdalena Rafecas,
Katarzyna Rusiecka,
David Schug,
Volkmar Schulz,
Achim Stahl,
Bjoern Weissler,
Ming-Liang Wong,
Aleksandra Wrońska
Abstract:
Objective. Prompt-gamma imaging encompasses several approaches for online monitoring of beam range or deposited dose distribution in proton therapy. We test one of the imaging techniques - a coded mask approach - both experimentally and via simulations. Approach. Two imaging setups have been investigated experimentally. Each of them comprised a structured tungsten collimator in a form of a MURA ma…
▽ More
Objective. Prompt-gamma imaging encompasses several approaches for online monitoring of beam range or deposited dose distribution in proton therapy. We test one of the imaging techniques - a coded mask approach - both experimentally and via simulations. Approach. Two imaging setups have been investigated experimentally. Each of them comprised a structured tungsten collimator in a form of a MURA mask and a LYSO:Ce scintillation detector of fine granularity. The setups differed in the detector dimensions and the operation mode (1D or 2D imaging). A series of measurements with radioactive sources have been conducted, testing the setups' performance of near-field gamma imaging. Additionally, Monte Carlo simulations of a larger setup of the same type were conducted, investigating its performance with a realistic gamma source distribution occurring during proton therapy. Main results. The images of point-like sources reconstructed from two smallscale prototypes' data using the MLEM algorithm constitute the experimental proof of principle for the near-field coded-mask imaging modality, both in the 1D and the 2D mode. Their precision allowed us to calibrate out certain systematic offsets appearing due to the misalignment of setup elements. The simulation of the full-scale setup yielded a mean distal falloff retrieval precision of 0.72 mm in the studies for beam energy range 89.5-107.9 MeV and with 1x10^8 protons (typical number for single distal spots). The implemented algorithm of image reconstruction is relatively fast - a typical procedure needs several seconds. Significance. Coded-mask imaging appears a valid option for proton therapy monitoring. The results of simulations let us conclude that the proposed fullscale setup is competitive to the knife-edge-shaped and the multiparalell slit cameras investigated by other groups.
△ Less
Submitted 22 June, 2023;
originally announced July 2023.